order code: EQLED40 user manual

Similar documents
w w w. p r o l i g h t. c o. u k TRI PAR 64 Order code: LEDJ48 - Black Order code: LEDJ49 - Polished USER MANUAL

w w w. p r o l i g h t. c o. u k Quad Par 64 (Order code: LEDJ46 - Black) (Order code: LEDJ47 - Polished) USER MANUAL

w w w. p r o l i g h t. c o. u k STAGE PAR 64

LEDJ Tri LED DJ Skirt Matrix Cloth - STAR17 USER MANUAL

Order code: EQLED60 USER MANUAL

Order code: EQLED53 User manual

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

Colour Burst Order code: LEDJ01 USER MANUAL

Professional DMX Stage Backdrop

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

LIGHT BRICK - 12 X 3W TRI-COLOUR

Fusion Saber. User Manual. Order code: EQLED070

Blitzer Strobe. User Manual. Order code: EQLED366

IMPACT Order code: EQLED79

Fusion Razor Beam. 3 x 12W Moving Head User Manual. Order code: EQLED006

UV Power Flood. User Manual. Order code: EQLED029

UV Spectra Batten 12 x 5W UV LEDs

Microbar COB System. User Manual. Order code: EQLED137

CDP 405 Digital Dimmer Pack

Crossfire. User Manual. Order code: EQLED061

CS2 DMX Distribution Splitter

RGB Power Batten. User Manual. Order code: EQLED032

MICRON DJ Booth Tri-colour Starcloth

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Gobo Projector XP 80W

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Performer 18 RGBWA MKII

Slimline CW & WW Series

Vector Beam White. User Manual. Order code: LEDJ265

DMX LED Starcloth Systems

PF LED Profile. User Manual

MICRON DJ Booth System with Overhead Kit & CW Starcloth

EasiLED 4 DMX Controller

Microbar Multi System

ZF LED Zoom Fresnel. User Manual

Hypnos. User Manual. Order code: EQLED372

Alu HEX Par 64. (12 x 12W six-colour LEDs RGBWAUV) User Manual. Order code: ELUM114

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

Saturn Spot. User Manual. Order code: EQLED023

Vortex. User Manual. Order code: EQLED073

Endura 1Q120 RGBW COB Exterior Fixture

Intense 9P10 RGBWA LED Slim Par

FTP1 Single Channel LED DMX Driver

Flexoled FTP3HP RGB LED DMX Driver

Intense 9HEX10 LED Slim Par

TRANSCENSION Show Control

Slimline 12Q5 Series

order code: EQLA04 user manual

Fresco 24 RGBW. Exterior Fixture User Manual. Order code: LEDJ267

Party Dimmer IEC ORDERCODE 50324

CPA 40 Two Channel Amplifier

User Instructions. American DJ

Multidim ORDERCODE 50391

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

Octostrip ORDERCODE 42220

4. How to Connect the Fixture 3-Pin and 5-Pin XLR DMX Connectors:

Light Brick ORDERCODE 50370

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

SP-1500 DMX MK II Strobe

50W/100W LED Alu. User Manual. Code: ELUM041-50W - (5600K) Code: ELUM041A - 100W (5600K) Code: ELUM041C - 50W - (3200K) Code: ELUM041D - 100W (3200K)

D-Pack 6 Classic ORDERCODE 50315

Heavy Duty DMX Mirror Ball Rotator with Safety Eye

Antenna Distributor ORDERCODE D1444

Starlit Dance Floor. User Manual

FUSION SPOT MKII EQUINOX. Contents. User Manual. Order codes: Black housing - EQLED Safety Instructions. 2. Features & Specifications

1 Channel Strobe Controller ORDERCODE 40226

LED PAR56 Order Code: P56-151

LED Dancefloor ORDERCODE 42300

Showdesigner 512 ORDERCODE 50721

1 Channel Sliding Profile Dimmer ORDERCODE 50425

LED W RGBA User Manual

MATRIX LED LED User Manual Please read the instructions carefully before use

LED MOVING HEAD FLEX BEAM K8 RGBW. User Manual. Please read the instruction carefully before use

FLEX BEAM V8. User Manual Please read the instruction carefully before use

LED Par 64 Short DMX ORDERCODE 42431

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

LED BEAM MOVING HEAD FL x3W User Manual

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

LED PANEL. User Manual Please read the instructions carefully before use LED-212RGB TABLE OF CONTENTS. 1. Safety Instructions

DM-X Channel DMX Controller. Item ref: UK User Manual. Version 2.0

LED Giga Bar 4. User Manual

Colour Star Sky I DMX ORDERCODE 40341

Flat Par 9 LEDs. battery power, Wirelss, Remote Control, RGBWA-UV 6-in-1 USER MANUAL. Please read over this manual before operating the light

Cobra Dimmer Master DMX Controller User Manual

Robot Light V2. User Manual

Warning... Safety-instructions Operating Determinations Rigging... Description... Features and Overview...

Professional Entertainment Technology. imove 50SR. Innovation, Quality, Performance 21-

LED BEAM MOVING HEAD 12x12W Cree, 4in1, beam 8 degree

SAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-

COLOR PAR 56 COLOR PAR 64. User Manual Please read the instructions carefully before use. Широкий ассортимент оборудования ACME на

LED DANCING FLOOR User Manual

IR Controller. Warning! To prevent or reduce the risk of electrical shock or fire, do not expose this unit to rain or moisture.

Titan Strobe ORDERCODE 40222

10W LED PIN SPOT. User Manual LED-PS10D W. Innovation, Quality, Performance. Professional Entertainment Technology 11-

DDS-405 LC DMX 4 Ch. Dimmer dimmer pack. user manual

Kameleon series RGB 3 in one USER MANUAL

LED Accu Penta 9x12W RGBWAU

CP 64 BD15 CP 64 PD15

LED SUPER PAR USER MANUAL

LED Powerbar 24 ORDERCODE 41331

Transcription:

HYPE order code: EQLED40 user manual www.prolight.co.uk

Safety WARNING FOR YOUR OWN SAFETY, PLEASE READ THIS USER MANUAL CAREFULLY BEFORE YOUR INITIAL START-UP! CAUTION! Keep this equipment away from rain, moisture and liquids. SAFETY INSTRUCTIONS Every person involved with the installation, operation & maintenance of this equipment should: - Be competent - Follow the instructions of this manual CAUTION! TAKE CARE USING THIS EQUIPMENT! HIGH VOLTAGE-RISK OF ELECTRIC SHOCK!! Before your initial start-up, please make sure that there is no damage caused during transportation. Should there be any, consult your dealer and do not use the equipment. To maintain the equipment in good working condition and to ensure safe operation, it is necessary for the user to follow the safety instructions and warning notes written in this manual. Please note that damages caused by user modifications to this equipment are not subject to warranty.

Safety IMPORTANT: The manufacturer will not accept liability for any resulting damages caused by the non-observance of this manual or any unauthorised modification to the equipment. Never let the power-cable come into contact with other cables. Handle the power-cable and all mains voltage connections with particular caution! Never remove warning or informative labels from the equipment. Do not open the equipment and do not modify the equipment. Do not connect this equipment to a dimmer-pack. Do not switch the equipment on and off in short intervals, as this will reduce the system s life. Only use the equipment indoors. Do not expose to flammable sources, liquids or gases. Always disconnect the power from the mains when equipment is not in use or before cleaning! Only handle the power-cable by the plug. Never pull out the plug by pulling the power-cable. Make sure that the available voltage is between 220v/240v. Make sure that the power-cable is never crimped or damaged. Check the equipment and the power-cable periodically. If the equipment is dropped or damaged, disconnect the mains power supply immediately. Have a qualified engineer inspect the equipment before operating again. If the equipment has been exposed to drastic temperature fluctuation (e.g. after transportation), do not switch it on immediately. The arising condensation might damage the equipment. Leave the equipment switched off until it has reached room temperature. If your product fails to function correctly, discontinue use immediately. Pack the unit securely (preferably in the original packing material), and return it to your Prolight dealer for service. Only use fuses of same type and rating. Repairs, servicing and power connection must only be carried out by a qualified technician. THIS UNIT CONTAINS NO USER SERVICEABLE PARTS. WARRANTY; One year from date of purchase. OPERATING DETERMINATIONS If this equipment is operated in any other way, than those described in this manual, the product may suffer damage and the warranty becomes void. Incorrect operation may lead to danger e.g.: short-circuit, burns, electric shocks, lamp failure etc. Do not endanger your own safety and the safety of others! Incorrect installation or use can cause serious damage to people and property.

Technical specifications You should find inside the Equinox carton the following items: 1, Equinox Hype 2, Power cable 3, Instruction manual Technical Specifications: DMX channels: 4 Voltage: AC 110-240V ~ 50Hz/60Hz 156 Ultra bright LED s (R: 36, G: 36, B:30, W:30, Y: 24) Fuse: 1 Amp Power Consumption: 15W Dimensions: 370 x 220 x 170mm Weight: 3.1Kg Operations: There are 3 operating modes to choose from: DMX Mode 1, DMX Mode 2, Auto Run 3, Sound Active mode When the unit is connected with a universal DMX controller, press the MODE button to show Addr in the LED display window, you can now set the DMX address from 001-512 using the UP and DOWN buttons, once you have set your desired DMX address press the SET UP button to confirm the setting. Auto Run Function Mode When the unit is not being used via a DMX controller, press the MODE button to show Func in the LED display window. Now press the SET UP button and select one of the three following operation modes using the UP and DOWN buttons: 1) Soun = Sound Active mode 2) Slav = Slave mode 3) Auto = Auto Run mode Once you have selected your desired operation mode press the SET UP button to confirm the setting. Sound Active Mode To activate the Sound Active mode, first please make sure that you selected Soun in the LED Display window from the above Auto Run Function Mode. Now press the SET UP button and select one of the 15 different flower effects using the UP and DOWN buttons. P-00 = Runs all 15 flower effects one after another P-01 >> P-15 = Runs selected individual flower effects Once you have set your desired flower effect press the SET UP button to confirm the setting. To adjust the sound sensitivity in Sound Active mode press the MODE button to show Sens in the LED display window, then press the SET UP button and adjust the sensitivity using the UP and DOWN buttons. Once you have selected your desired sensitivity level, press the SET UP button to confirm your setting. ( S-00 = Low, S-15 = High)

Functions Other functions Slave Mode To set the unit in the Slave mode, press the MODE button to show Func in the LED display window. Now press the SET UP button and use the UP and DOWN buttons to show Slav in the LED display window and press the SET UP buton to confirm the setting. The unit will now run in conjunction with the Master unit when linked together with multiple units. LED Display On/Off Press the MODE button to show LED in the LED display window and press the SET UP button to choose one of the two following options using the UP and DOWN buttons. 1) ON = The LED display will stay ON all of the time 2) OFF = The LED dispaly will turn OFF after the setting has been confirmed Once you have selected your desired option, press the SET UP button to confirm your setting Blackout Mode Press the MODE button to show Blnd in the LED display window and press the SET UP button to choose one of the two following options using the UP and DOWN buttons. 1) NO = Auto run mode when the unit is not in Sound Active 2) YES = Blackout mode when the unit is not in Sound Active Once you have selected your desired option, press the SET UP button to confirm your setting DMX Function Chart Channel 1 Channel 2 Channel 3 Channel 4 Function 000-009 000-009 N/A N/A Blackout Mode 000-009 010-255 Strobe Speed Master Dimmer Static colour mode (Use CH2 to select any of the 24 static patterns/colours) 010-255 000-255 Strobe Speed Master Dimmer Sound Active Mode (Use CH2 to select any of the 30 built-in dynamic patterns triggered via the internal microphone)

DMX Set up DMX-512: DMX (Digital Multiplex) is a universal protocol used as a form of communication between intelligent fixtures and controllers. A DMX controller sends DMX data instructions form the controller to the fixture. DMX data is sent as serial data that travels from fixture to fixture via the DATA IN and DATA OUT XLR terminals located on all DMX fixtures (most controllers only have a data out terminal). DATA Cable (DMX cable) requirements (for DMX operation): The Equinox Hype can be controlled via DMX-512 protocol. The DMX address is set on the back of the unit. Your unit and your DMX controller require a standard 3-pin XLR connector for data input/output (figure 1). Figure 1 Further DMX cables can be purchased from all good sound and lighting suppliers or Prolight dealers. Please quote: CABL10 2M CABL11 5M CABL12 10M Also remember that DMX cable must be daisy chained and cannot be split.

DMX Set up Notice: Be sure to follow figures 2 & 3 when making your own cables. Do not connect the cable s shield conductor to the ground lug or allow the shield conductor to come in contact with the XLR s outer casing. Grounding the shield could cause a short circuit and erratic behaviour. Special Note: Line termination: When longer runs of cable are used, you may need to use a terminator on the last unit to avoid erratic behaviour. Termination reduces signal transmission problems and interferance. it is always advisable to connect a DMX terminal, (resistance 120 Ohm 1/4 W) between pin 2 (DMX-) and pin 3 (DMX+) of the last fixture. Using a cable terminator (part number CABL90) will decrease the possibilities of erratic behaviour. 5-Pin XLR DMX Connectors: Some manufactures use 5-pin XLR connectors for data transmission in place of 3-pin. 5-Pin XLR fixtures may be implemented in a 3-pin XLR DMX line. When inserting standard 5-pin XLR connectors in to a 3-pin line a cable adaptor must be used. The Chart below details the correct cable conversion.

w w w. p r o l i g h t. c o. u k