PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Similar documents
PMDX-103. Parallel Port Isolator Board. User s Manual. Document Revision: 1.2 Date: 20 February 2007 PCB Revision: PCB-447B

PMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual

PMDX-170 Slotted Optical Sensor

PMDX-105 Quad Isolator Board

PMDX Axis Breakout/Motherboard for Gecko Stepper Motor Drivers User s Manual

PMDX-120. Parallel Port Accessory Module. User s Manual

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

AN004 Using the PMDX-126 s Error Input and Restart Output with Geckodrive Servo Drivers and Mach3 CNC Software

Using the PMDX-125/126 Mach3 Plug-In Ver

PSA200 User s Manual

Resolver to Digital Expansion Board

OPERATIONS MANUAL PCM-I/O48

MPP1700 User s Manual

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

MULTIPLEXER MX4. Operation and Installation Manual. Pacific Micro Systems

INSTRUCTION MANUAL. Sensoray Model 720RB/DIN. Relay I/O Board (Rev A) October 12, 2001

FNet Repeater Installation & Operator s Instruction Manual

User Guide. Control Box. RoscoLED TM.

MPP200 User s Manual

Tornado F-5. Motor Backspin Detect Relay And Probe For F-5 Motor Controller

CF15118 CompactFlash Carrier utilitymodules User s Manual

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

AC4G-D User s Manual

PMDX-416 SmartBOB-OptoUSB For use with Mach4

OPERATIONS MANUAL PCM-DOC

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

Relay Board. User Manual. 1.0, Oct 2013

TB-100 ControLynx Terminal Block

Sensoray Model 627 CompactPCI to PCI Adapter

SATA II HDD Canister KISS DA 435 Quick Reference Guide

DCM Digital Control Modules

X-12s Users Manual. X-12s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

Integrated Stepper Drive & Motor

CA-A480-A Elevator Controller. Reference & Installation Manual

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual

CM17215HR 100Mb/s Fiber CM17212HR 10/100Mb/s UTP PC/104-Plus Dual Ethernet utilitymodule. User s Manual. BDM Rev. C

Seven Channel Remote Control

Chore-Tronics Mobile Server

iconverter 2-Module Power Chassis

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

User's Guide. Model High Precision Quad Output DC Power Supply

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

Network Computing. RC-PCIEM201A User Manual. Version: 1.0 Date of Release:

APWR106HR Filtered Avionics Power Supply Module User s Manual

Instruction and Operation Manual. CRMS Contact Resistance Measurement System. Model Number Caution!

G540 User Manual. Date Modified: March 5, 2012 Page 1 of 10

ACLD Channel Opto-isolated Digital Input Board

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

X-11s Users Manual. X-11s User Manual Revisions Revision Description Initial release. Xytronix Research & Design, Inc.

CMT6118 IDE Controller and Compact Flash Carrier with Floppy utilitymodule User s Manual

User s Guide. POWERVAR Single Phase Power Conditioners

SP-1009D. 1x9 Dual Link DVI Distribution Amplifier. User Manual. Made in Taiwan

APWR104HR Filtered Avionics Power Supply Module User s Manual

INSTALLATION, OPERATION & MAINTENANCE CRFF Series Wall Control Console. ECM Motors. ACC1-25 (Part # ) Revision:

PV3500. Fuel Site Controller. Service Manual OPW Fuel Management Systems Manual M Rev. 1

G540 MANUAL MULTIAXIS STEP MOTOR DRIVE

PCL451. Manual Preset Indexer. User s Guide E Landon Drive, Anaheim, CA

WARRANTY & LIMITATION OF LIABILITY

OP8/16 Optoisolated Digital Input Board User's Manual

Hybrid AC Driver [GCNC-1110]

User Guide. DMXSM-H18 Splitter. DMXSM-H81 Merger. Document Release Aug Revision B

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

WARRANTY & LIMITATION OF LIABILITY

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

MEC-COM-M114. User s Manual

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY

Grundfos MAGNA, GENI Module

Digital Lighting Systems, Inc. PD216. Two Channel Dimmer and Switch Packs PROTOCOL USER'S MANUAL. PD216-UM Rev. E - 02/03

Wall. No opening (Example: LA-030-W)

C Mb Ethernet Copper Tap

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

Sensoray Model 623 PC/104+ to PCI Adapter. Revised December 19, Sensoray Model 623 Instruction Manual 1

I/O Expansion Box Installation & Operator s Instruction Manual

Install Motor Controller User Manual

8-Channel Relay Output Board Via I 2 C, USB Protocol P/N KA-I2C-8-RL-PWR-TH. I2C-USB-Relay8. User Manual. Page 1 / 17

UNIPORT V2. Uniport V2

700 Series 200 Amp Clamp Meters

INTELLIGENT DOCKING STATION USERS MANUAL

The EB7-4W plugs onto one- or two-channel speaker or headset stations as illustrated in Figure 1. EB7-4W. Option. 4-Wire. Option

SERVICE MANUAL MODEL WPP-531-X-ADA MODEL SSP-511- X-ADA

SMD Series Integrated Stepper Driver and Motor Revision 1.3

User Guide. Single-Link DVI Fiber Optic Extender DVI-7315

MEC-COM-M154. User s Manual

8-Channel Relay Output Board Via I 2 C Protocol. I2C-Relay8

Automated Tuner System Power Distribution Hub

OPERATION MANUAL SMARTLAB USB 8 CHANNELS RELAY OUTPUT 8 CHANNELS PHOTO ISOLATOR INPUT BOARD

INSTALLATION & OPERATING INSTRUCTIONS

ControlKeeper 4. General Information. Connecting Relay Loads. Installation Sheet. Getting Started. Power Supply Wiring. Mounting the Cabinet

BRG17088HR User's Manual PCI to ISA Bridge PC/104-Plus Module

Operating Manual RISH DPM Hz

This revision of the manual is dated June, All modifications from previous versions are listed in the appendix.

MODEL USBP-DIO16RO8. DIGITAL INPUT/OUTPUT BOARD w/8 ELECTROMECHANICAL RELAYS USER MANUAL

Debitek Card Revalue Station Installation Manual

Sonic Ruptor 400. User Manual

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

Transcription:

PMDX-105 I/O Option Riser Board User s Manual Date: 7 September 2004 PMDX Web: http://www.pmdx.com 7432 Alban Station Blvd., A105 Phone: +1 (703) 912-4991 Springfield, VA 22150-2321 USA FAX: +1 (703) 912-5849 PMDX-105_Manual_11.doc 2004, Practical Micro Design, Inc. Page 1 of 9

Table of Contents 1.0 Overview...3 1.1 Configuration Options... 3 1.2 Important Safety Information... 3 1.3 Warranty Summary... 3 1.4 Features... 4 1.5 Updates to this Manual... 4 2.0 Connectors...4 2.1 Motherboard Connector (J1)... 4 2.2 Control Output Connector (J2)... 4 2.3 Status Input Connector (J3)... 5 2.4 Relay Contact Connectors (J7)... 6 3.0 Solid State Relays...6 3.1 10-Amp Relay (optional)... 6 3.2 2-Amp Relay (optional)... 7 3.3 Relay Enable Jumper (JP1)... 7 4.0 Mechanical Specifications...8 5.0 Electrical and Environmental Specifications...8 Appendix A Warranty...9 PMDX-105_Manual_11.doc 2004, Practical Micro Design, Inc. Page 2 of 9

1.0 Overview This document describes the configuration and operation of the PMDX-105 I/O Option Riser Board. The PMDX-105 provides access to the PC parallel port status and control signals when used in conjunction with the PMDX-130 4-Axis Motion Control Motherboard. This document pertains to the following versions of the PMDX-105: Circuit Board Revision: PCB-443A (marked on the bottom of the board) 1.1 Configuration Options The PMDX-105 can be built in several different configurations: PMDX Part Number PMDX-105-00 PMDX-105-01 PMDX-105-02 PMDX-105-03 Configuration Basic I/O board, no solid-state relays Basic I/O board with 2-Amp solid-state relay Basic I/O board with 10-Amp solid-state relay Basic I/O board with both 2-Amp and 10-Amp solid-state relays Table 1 - PMDX-105 Configurations 1.2 Important Safety Information The PMDX-105 is intended for integration by the purchaser into industrial control systems. It is solely the purchaser's responsibility to assure that the system is configured in a manner consistent with applicable safety requirements. Practical Micro Design, Inc. does not control how this board is integrated into the purchaser's system and cannot be responsible for guaranteeing the safety of your system. The PMDX-105 is not guaranteed to be fail-safe. The system into which the PMDX-105 is installed should provide fail-safe protection and emergency stop capability. The PMDX-105 contains circuitry that may be connected to dangerous voltages. Care must be taken that user cannot come in contact with these voltages. An enclosure that allows for modest ventilation, but prevents intrusion by operator s hands and foreign objects, especially conductive byproducts of machining operations, should be utilized with this board. Interlock switches on power circuits should remove power when the enclosure is opened. Automated machine tools, into which the PMDX-105 may be integrated, can cause injury. Precautions should be taken to assure that operators are trained in their proper operation and safety procedures, and that they are protected from moving parts that may be under remote control and may move unexpectedly. This product may not be used in life support or other critical safety applications. 1.3 Warranty Summary The PMDX-105 is warranted against failure due to defective parts or workmanship for 90 days from the date of sale. Refer to Appendix A for complete warranty details. If you have an item requiring service, please see the support page on the PMDX web site (http://www.pmdx.com) for return instructions. The purchaser must pay shipping to return the unit to PMDX. We will ship the repaired unit back to you via ground transportation at our expense. Repairs are normally completed within 10 business days. See Appendix A for our complete warranty details. PMDX-105_Manual_11.doc 2004, Practical Micro Design, Inc. Page 3 of 9

1.4 Features The PMDX-105 has the following features: Status Inputs: 4 each general-purpose digital inputs E-Stop input Wire clamp screw terminals for each input Control Outputs: 4 each general purpose digital outputs Charge Pump OK output Wire clamp screw terminals for all outputs Solid-State Relay Outputs (optional): Optional 10-Amp opto-isolated 240 VAC relay output Optional 2-Amp opto-isolated 240 VAC relay output Wire clamp screw terminals Charge Pump OK override via jumper option 1.5 Updates to this Manual Check the PMDX web site for revisions or updates to this manual (http://www.pmdx.com). The latest revision of this manual is available on the PMDX-105 page (follow the links from the main page). 2.0 Connectors The PMDX-105 contains the following connectors. Refer to the following sections for details on the pinouts for each connector. For all connectors, pin 1 is the pin closest to the reference designator (i.e. J1 pin 1 is the pin closest to the J1 text on the circuit board). In addition, all connectors have square pads on pin 1 (look on the bottom of the circuit board). Connector J1 J2 J3 J7 Description Motherboard Connector (mates with PMDX-130 Motherboard) Control Outputs Status Inputs Solid-State Relay Outputs Table 2 - Summary of PMDX-105 Connectors 2.1 Motherboard Connector (J1) This connector plugs into the P2 connector on the PMDX-130 motherboard (which is labeled I/O Card Slot ). The PMDX-105 should be plugged in so that the screw terminal connectors are towards the edge of the PMDX-130 that has the Centronics (parallel port) connector. WARNING: Use caution when installing this board onto the PMDX-130 motherboard. It is possible to plug the board into the motherboard connector such that the connectors are not properly aligned. 2.2 Control Output Connector (J2) The PMDX-105 brings all four PC parallel port control signals to the J2 connector. These signals connect directly to the corresponding PC parallel port control signals (by way of the PMDX-130 motherboard). They are not buffered, nor are they opto-isolated. The Charge Pump OK signal from the PMDX-130 motherboard is also present on this connector. PMDX-105_Manual_11.doc 2004, Practical Micro Design, Inc. Page 4 of 9

The ~ character before the signal name indicates that the normal PC parallel port function uses that signal as an active low output. The actual polarity for motion control purposes depends on the application software that you are using. Pin Parallel Description Number Port Pin # 1 N/A Ground 2 N/A ~CP_OK (the Charge Pump OK signal from the PMDX-130 motherboard). This signal is intended to be the ground reference for any opto-isolators used with the PMDX-105, so that the opto-isolators can be disabled when the PMDX-130 s charge pump detects a problem. This signal is either ground or open circuit. 3 1 ~Strobe (also controls one of the optional solid-state relays, see section 3.1) 4 14 AutoFeed (also controls one of the optional solid-state relays, see section 3.2) 5 16 ~Init 6 17 ~Select_In Table 3 Control Output Connector Pin-Out (J2) WARNING: Do not use ~Strobe and AutoFeed as general-purpose outputs on this connector when using the corresponding on-board solid-state relays. NOTE Due to logic inside the PC, some control outputs are inverted. This means that that writing a 1 to a bit in the control register may result in a logic low at the 25-pin D connector. Please refer to technical documentation on the PC parallel port, or your control software, for more information. 2.3 Status Input Connector (J3) The PMDX-105 provides screw terminals for four of the five PC parallel port status signals. These signals connect directly to the corresponding PC parallel port signals (by way of the PMDX-130 motherboard). They are not buffered, nor are they opto-isolated. The ~Ack status signal is not brought out on the PMDX-105 board because the PMDX-130 motherboard uses this signal to send it s fault status to the PC. This connector also provides access for an external Emergency Stop ( E-Stop ) input. The E-Stop input should be connected to an external normally closed switch (or group of switches all wired in series). The external switch(es) should be wired between the E-Stop pin and ground, such that the switch contacts open to indicate an emergency stop condition. Refer to the PMDX-130 User s Manual for more information on the emergency stop function. If no E-Stop circuit is provided, a jumper wire must be installed between the E-Stop pin and ground. The ~ character before the signal name indicates that the normal PC parallel port function uses that signal as an active low input. The actual polarity for motion control purposes depends on the application software that you are using. PMDX-105_Manual_11.doc 2004, Practical Micro Design, Inc. Page 5 of 9

Pin Parallel Description Number Port Pin # 1 N/A Ground 2 N/A E-Stop Input 3 11 Busy 4 12 PE (Paper Empty) 5 13 Select Out 6 15 ~Error Table 4 Status Input Connector Pin-Out (J3) NOTE Due to logic inside the PC, some status inputs are inverted. This means that for some status signals, a logic high input from the PMDX-105 to the PC s parallel port is read as a 0 in the status register. Please refer to technical documentation on the PC parallel port, or your control software, for more information. 2.4 Relay Contact Connector (J7) The relay contact connector is populated if the PMDX-105 has one or both of the optional solid-state AC relays. See section 3.0 for more information on these optional relays. Pin Number Description 1 Relay common input (AC voltage source) 2 10-Amp switched load (requires external fuse, see section 3.1) 3 2-Amp switched load (see section 3.2) Table 5 Relay Contact Output Connector Pin-Out (J7) 3.0 Solid State Relays The PMDX-105 has provisions for two optional solid-state AC relays. These relays allow the PC to control AC power to external devices such as spindle motors and coolant pumps. The relays are controlled by two of the PC s parallel port control signals. Jumper JP1 determines if the Charge Pump OK signal can force the relays to the open state (see section 3.3). 3.1 10-Amp Relay (optional) Relay K1 (if installed) is a 10-Amp, 240 VAC solid-state relay. This relay requires the use of an external 10-Amp (maximum) fuse in the Relay Common Input lead (see section 2.4). The relay is controlled by the PC parallel port ~Strobe signal (PC parallel port connector pin 1). The relay is open when the ~Strobe signal is a logic low, and closed when the ~Strobe signal is a logic high. The Charge Pump OK signal may override this control and force the relay to the open state, depending on the setting of JP1 (see section 3.3). WARNING: Do not use the ~Strobe signal on the Control Output Connector (J2) when using this on-board solid-state relay. PMDX-105_Manual_11.doc 2004, Practical Micro Design, Inc. Page 6 of 9

NOTE Due to logic inside the PC, the ~Stobe control output is inverted. This means that writing a 1 to a bit in the control register results in a logic low at the PC s 25-pin D connector. In order to energize ( close ) the relay, a 0 must be written to the parallel port control register. Please refer to technical documentation on the PC parallel port, or your control software, for more information. 3.2 2-Amp Relay (optional) Relay K2 (if installed) is a 2-Amp, 240 VAC solid-state relay. The PMDX-105 provides an on-board 2-Amp fuse for this relay. This fuse is a 5mm x 20mm fuse, and must be no greater than 2 amps. The 2-Amp relay is controlled by the PC parallel port AutoFeed signal (PC parallel port connector pin 14). The relay is open when the AutoFeed signal is a logic low, and closed when the AutoFeed signal is a logic high. The Charge Pump OK signal may override this control and force the relay to the open state, depending on the setting of JP1 (see section 3.3). WARNING: Do not use the AutoFeed signal on the Control Output Connector (J2) when using this on-board solid-state relay. 3.3 Relay Enable Jumper (JP1) Jumper JP1 is labeled RelayEN and selects whether or not the PMDX-130 s charge pump circuit can disable the solid-state relays. Setting Label Description 1 to 2 CP-OK PMDX-130 s Charge Pump OK signal determines relay state as follows: Charge pump is OK: PC parallel port signals determine whether the relays are open or closed Charge pump is NOT OK: relays are forced to the open state, ignoring the PC parallel control signals 2 to 3 always Relays always respond to the PC parallel port control signals Table 6 Relay Enable Jumper Settings (JP1) PMDX-105_Manual_11.doc 2004, Practical Micro Design, Inc. Page 7 of 9

4.0 Mechanical Specifications 2.750" 6 5 4 3 2 J3 1 Inputs 3.400" 6 5 4 3 J1 J2 2 1 Outputs Figure 1 - PMDX-105 Dimensions and Mounting Holes WARNING: The PMDX-105 should be protected from liquids, dirt, or chips (especially metal chips which can cause shorts) coming in contact with the board. 5.0 Electrical and Environmental Specifications Status Inputs: Refer to the PMDX-130 User s Manual for status input signal levels Control Outputs: Solid-State Relays: Relay K1 Relay K2 Refer to the PMDX-130 User s Manual for control output signal levels 240 VAC maximum, 10 amps maximum, from relay common terminal (requires an external fuse) 240 VAC maximum, 2 amps maximum, from relay common terminal (has on-board fuse) Environmental: Temperature: 0 to +55 C Relative Humidity: 20% to 80% relative humidity, non-condensing PMDX-105_Manual_11.doc 2004, Practical Micro Design, Inc. Page 8 of 9

Appendix A Warranty Statement Practical Micro Design, Inc. (PMD) warrants that this hardware product is in good working condition, according to its specifications at the time of shipment, for a period of 90 days from the date it was shipped from PMD. Should the product, in PMD's opinion, malfunction within the warranty period, PMD will repair or replace the product without charge. Any replaced parts become the property of PMD. This warranty does not apply to the software component of a product or to a product which has been damaged due to accident, misuse, abuse, improper installation, usage not in accordance with product specifications and instructions, natural or personal disaster or unauthorized alterations, repairs or modifications. Limitations All warranties for this product, expressed or implied, are limited to 90 days from the date of purchase and no warranties, expressed or implied, will apply after that period. All warranties for this product, expressed or implied, shall extend only to the original purchaser. The liability of Practical Micro Design, Inc. in respect of any defective product will be limited to the repair or replacement of such product. Practical Micro Design, Inc. may use new or equivalent to new replacement parts. Practical Micro Design, Inc. makes no other representations or warranties as to fitness for purpose, merchantability or otherwise in respect of the product. No other representations, warranties or conditions, shall be implied by statute or otherwise. In no event shall Practical Micro Design, Inc. be responsible or liable for any damages arising (a) from the use of the product; (b) from the loss of use of the product; (c) from the loss of revenue or profit resulting from the use of the product; or (d) as a result of any event, circumstance, action or abuse beyond the control of Practical Micro Design, Inc. whether such damages be direct, indirect, consequential, special or otherwise and whether such damages are incurred by the person to whom this warranty extends or a third party. PMDX-105_Manual_11.doc 2004, Practical Micro Design, Inc. Page 9 of 9