BSX (Bell System Exchange) and DAX Digital Isolating Door Entry Systems

Similar documents
Bell System (Telephones) Ltd

9. Settings and Adjustments Switch Setting Chart Speech Levels Trades Clock Parts List 13

Bell System (Telephones) Ltd. Digibell. Digital Audio Door Entry System Vandal Resistant. Installation & Operation Guide.

TECHNICAL MANUAL EDITION 1.4 SENTRY TECHNICAL MANUAL

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Neon Secure Access Functional Door Entry Specification at last door entry as it should be

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

Entryphone. PinNet 4. Product manual. October 2010 R Granville Road, London SW18 5SD

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

8000 series Modular System

Folknoll. System Manual. Disabled Refuge EVC. Disabled Refuge EVC RA System Manual

DESIGN QUALITY TECHNOLOGY

Gladiator Lift Services Ltd OPTIO MRL Controller Specification

AUDIO AND VIDEO KITS SECTION CONTENTS 66

PRO700 EXCHANGELESS INTERCOM CRITICAL COMMUNICATION

TELEPHONES & CABINETS

STENTOFON PRO700 ExchangElEss IntERcOm

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

Catalogue 2013/2014. IP video door intercom system for smartphones and tablets (ios, Android)

Residential Apartment/College Residence Halls Gated Communities Mixed Use Buildings Commercial/Industrial Parking Self Storage Maximum Security

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

TECHNICAL MANUAL. 25H/DDA One button DDA audio intercom kit TECHNICAL MANUAL EDITION 1.1

bellissimo Bell System (Telephones) Ltd. Video Door Entry System 1 Way Installation & Operation Manual This manual applies to the following:

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

Catalog. IP video door intercom system for smartphones and tablets (ios, Android)

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

NEW. Bticino modular entrance panels. Sfera. CHOOSE YOUR FINISH Replace the dots in the Cat. No. with either 1, 2, or 3 to select the desired finish

Prestige Warden Call

DP4 DOOR PHONE. For Technical Assistance Please Phone: (07)

Bell System (Telephones) Ltd. Bellcall. Digital Door Entry System. Installation & Operation Manual. This manual applies to : -

Typical Digibell VR 1 or 2 Gate system with several small blocks and zonal flat isolation (DBA-8Z) and BSSW Gate/Block Isolator

CLA-VAL Control Panel

YOU FOR CHOOSING UNITEC PARTS COMPANY UNITEC PARTS COMPANY

Smartair. Proximity access control. ASSA ABLOY, the global leader in door opening solutions

Model HM-535 Power Supply Installation and Service Instructions

Introducing the Touch Door Entry Range

Bell System (Telephones) Ltd. bellfree. Digital Video Door Entry System With Hands-free Colour Apartment Stations Installation & Operation Manual

Tek-ENTRY Telephone Entry System. Specification Sheets Submittal Package. as of 10/4/2010

INSTALLATION INSTRUCTIONS

January 2018 PRICE SCHEDULE A 2.0 Access Control Devices

CU-8R Installation Instructions

January 2019 PRICE SCHEDULE A 2.0 Access Control Devices

TOUCHLOCK compact. Ins-182 Date code:

Lab 5: Access Control Training Station

Installation Manual & User Instructions

TSL Trust Your Senses to a Proven Partner PUSH BUTTONS, DISPLAY DEVICES AND LIGHTS. Public Transportation COMPONENTS FOR MODERNIZATION

Controller Cardax FT Controller The CardaxFT Controller 5000 is the intelligent field controller in the CardaxFT security system.

S - S T E E L 2 V O I C E K I T S P A R T S - L I S T UK 2015 URMET IS IN YOUR LIFE

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

D O O R S T A T I O N W I T H P R O X I M I T Y R E A D E R

Bell System (Telephones) Ltd. bellagio. Digital Video Door Entry System. Installation & Operation Manual. This manual applies to the following: -

ACCESS CONTROL SYSTEM

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

DIGITAL 2 WIRE SYSTEM

ACTsmart2 Product Range Operating and Installation Instructions

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

CONTROL PANEL WIRING SPECIFICATIONS

Quartz. Digital. Dual switch. Installation guide. Quartz Digital Dual switch installation instructions Page 1

America s gatekeeper.

TOUCHLOCK compact keypad Stainless Steel

Wiring Instructions v4

Models 300, 310, 320, 330 PROTECTIVE AND SUPERVISION STORAGE CABINET FOR AUTOMATED EXTERNAL DEFIBRILLATORS (AED)

CP150B Vandal & Weather Resistant Keypad Security Systems

BT1 / BT1-DDA Door Entry Telephone Interface

PROTECT and SHOWCASE your investments! Water Proof Tamper Proof Dust Proof Weather Proof

TrueCom. Building Communications Systems 5110-Series Controllers. UL Listed. Features. Operation. Description

LEE DAN COMMUNICATIONS, INC.

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

January 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

RE-1 Residential Telephone Entry by Linear

Installation Manual for D244X Series 24-volt Power Supplies

CardaxFT Reader I/O Interface

Speak to and see your visitor from your smart-phone. Easy wireless connection to existing home Wi-Fi. Up to 60 metre range with included directional

DAHUA IP INTERCOM TRADE ONLY

Digital Keypad Introduction

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

Protege Vandal Resistant Touchscreen Intercom Entry Station

EMS10 - EMS50. Cameo specification sheet. Product Description

Emergency Phone Standards

Internal Printer. Features.

Rev 1.00

LEE DAN COMMUNICATIONS, INC.

duplex communication (with handset) hands-free talking simplex communication can be activated standard 4 (up to 2 from front-door stations)

Readers and Keypads PB 1

LEE DAN COMMUNICATIONS, INC.

Colour Monitor 21 VGA and BNC REF Numeric multiplexer 8 channels without hard drive and 8 alarm inputs REF

TELEPHONE TECHNICAL SERVICES DS2 USER GUIDE

VPROX 250 Ver KEYS/TAGS 3 DOORS SYSTEM DESCRIPTION

forté Compatible Compatible Simple, Secu re, Stylish... USER GUIDE AND INSTALLATION MANUAL electronics

MULTIWAY 2-12 WAY DOOR ENTRY SYSTEM

Fire Shutter Electrically Operated. Insert address here OPERATING AND MAINTENANCE MANUAL SAFETY, SERVICE & REPAIR. flexability is our strength

Emergency. Lighting. CATALOGUE Vol. 01. Decentralised and centralised supply

Way kits. Do it your Way. Technology. Fermax presents the WAY kits: a range of video door entry system kits for homes and offices.

ZC Series Zone Monitoring Controllers

Easikey 250. User and Installation Guide v1.0 August 09

KeyWatcher Illuminated Specifications

User Guide ZXT315 MANAGER S DISPLAY PANEL

FIRE RESISTANT ROLLER SHUTTER DOOR

Transcription:

58

BSX (Bell System Exchange) and DAX Digital Isolating Door Entry Systems The BSX and DAX door entry systems are designed to overcome a common problem experienced in local authority and public housing where door entry systems are subject to vandalism from visitors and tenants. These systems operate on the Line Isolation principle which has two advantages over common-wired systems: Any malicious damage sustained to an individual telephone or its associated cable will not affect the operation of the rest of the system. The telephone conversation between the tenant and the caller is totally private. Each system includes Tradesmen/Service entry, a fire-switch input, battery standby facility and timed fail secure and fail safe lock outputs as standard. The central exchange unit with diagnostic LED s simplifies maintenance and any part is easily exchanged with readily available spares. 59

BSX8 Cabinet Model BS-LX Model LCP8 The BSX control unit The BSX control equipment is housed in a secure lockable steel IP55 rated cabinet and can include the following: Isolating fused PCB removable connectors for the telephones. A model TS2000-BST 7 day quartz reserve time clock for trades access. Regulated PSU with isolation switch. A control PCB for each entrance providing timed outputs for door releases (failsafe and fail secure), output tones and inputs for fire switches and trades buttons. A 12V 7A/H battery when battery standby is specified. Optional access control e.g. Proximity controllers. Two BSX Control units are available; 8 station (BSX8) 16 station two door (BSX16) Telephones Any of our DC type telephones may be used with the BSX exchange. Each telephone connected to the BSX control will have privacy of speech due to the line isolation. To achieve full 'line-isolation', the telephones must be individually cabled directly to the control unit. The standard model 801 telephones can be used for economy but the model BS-LX is highly recommended due to its added functions. Front door panels The model VRP and model LCP panels are recommended for use with the BSX system due to their resistance to vandalism. Reassurance tone A reassurance to the visitor that a call has been made and to indicate when the lock release has been operated. 60

Tradesmen facility The facility for a time-restricted entry for tradesmen is included on the BSX control. The operation of the Trades push-button will only trigger the door release when the time clock within the BSX control is set to an ON period. Fire services switch A Fire Service switch can be used to permanently release the lock in the event of an emergency (a continuously rated type release or Maglock should be used). Electric lock release The BSX control provides two alternative outputs for lock releases; FAILSECURE or FAILSAFE (including magnetic locks). 61

Model DPX-LED DAX32 Cabinet Model BS-LX The DAX digital system operates on the Line Isolation principle which has two advantages over common-wired systems; Any malicious damage sustained to an individual telephone or its associated cable will not affect the operation of the rest of the system. The telephone conversation between the tenant and the caller is totally private. System features; up to 256 flats up to 4 entrances large LED dot matrix display 4 digit alpha-numeric flat numbers 4 digit coded access facility trades facility porter facility (optional) standby battery backup outputs for fail safe and fail secure releases Model DAX exchange control All the control equipment is installed in one or more IP55 rated secure lockable steel cabinets. Each control contains one or more of the following components; All necessary control equipment 8 way Relay PCB s for connection of telephones Model TS2000-BST 7 day quartz reserve Time Clock for trades access 12v DC 5A power supply with standby facility optional 12v 7A/H lead-acid battery The control has LED diagnostics and Test modes for commissioning and maintenance purposes 62

Model DPX-LED Front Door Panel The front-plate consists of an overlapping bezel and a removable plate cut by a laser from the same sheet of 2.5 mm 316 marine grade stainless steel. This leaves a gap of just 0.2 mm rejecting implements that could be used to force the panel from its box. The bezel is securely welded to a back-box of 1.5 mm 316 grade stainless steel. This provides an extremely strong fixing to the wall. The removable plate is fixed to the bezel and back box with countersunk A2 stainless steel security bolts requiring the use of a specialist tool for their removal (supplied). The LED dot matrix display module offers excellent visibility with large red characters. A transparent LEXAN window gives maximum protection from vandals. Stainless steel vandal resistant push-buttons are used throughout. Clear operating instructions are engraved on the panel in black. Options can include cutouts for a Video camera and Proximity. Telephones Any of our DC type telephones may be used with the DAX exchange. Each telephone connected to the DAX control will have privacy of speech due to the line isolation. To achieve full isolation, each telephone station must be individually and directly cabled to the DAX control. However, the system is able to operate in partial isolation mode commonly referred as zone isolation for more economic cable installation. The standard model 801 telephones can be used for economy but the model BS-LX is highly recommended due to its added functions. 63