IMIO100 IMIO105. DDC controllers. Summary

Similar documents
mark150s mark150/485s DDC controllers Summary

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

Touch screen operator unit

HT101. User terminal. Function

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

Communicative controller for VAV systems

UC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display

Evo2. Free programmable room controller. Summary

Small distributed I/O module

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Modbus TCP/RTU MP-Bus converter

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

AIAS. Technical description

EXOcompact. Third generation freely programmable controllers

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

TM221CE40R controller M IO relay Ethernet

Communicative heating controller, Ethernet

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

General information Engineering with Programming package. Display with display

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

POL635.XX/XXX POL636.XX/XXX POL638.XX/XXX POL638.70/XXX

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Climatix TM Climatix Controller. For controlling, switching and monitoring functions

1. CP430, CP470, CP474, CP770 and CP774

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

Operating instructions. Switching amplifier DN0210 DN / / 2015

Features and Benefits. Certifications

Climatix programmable controller

Intech Micro 2300-RTD6 analogue input station MODBUS RTU slave application supplementary manual.

Operator units CDPX Key features

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

General information. Display. Supply voltage. Input current. Encoder supply. Output current. Power loss. Memory

General information. Display. Supply voltage. Input current

Features and Benefits. Certifications

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Voltage Transducer UMT516 / MT516

Universal Controller

TM221CE24R controller M IO relay Ethernet

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

EC-PU4. Processor unit with 4 communication ports

TM221ME16T controller M IO transistor PNP Ethernet

INSTALLATION MANUAL Z-UMTS

TM221CE40R controller M IO relay Ethernet

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

RXTP ROOM TEMPERATURE

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

Expansion Module HZS 541-1S

TM241CE24T controller M IO transistor PNP Ethernet

TM241C40U controller M IO transistor NPN

General information. Display. Supply voltage. Input current. Encoder supply. Output current

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

RAD-DAIO6-IFS. I/O extension module, 1 analog input/output, 2 digital wide-range inputs/outputs. INTERFACE Data sheet.

MCX06C Programmable controller

Non-communicating room controllers

TM241C24T controller M IO transistor PNP

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

TM221M16R controller M IO relay

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

TM221C40R controller M IO relay

TM241CE40R controller M IO relay Ethernet

OP10. Pre-programmed, configurable controller for simple applications

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

TM241C40R controller M IO relay

USER MANUAL. Longo programmable controller LPC-3.IOR.001 Input Output Relay PLC. Version 2

TM221M16TG controller M IO transistor PNP spring

General information. Display. Supply voltage. Input current. Encoder supply. Output current

BMKC Controller for Parabolic Trough application without encoder, 8 In 8 Out 4 AI

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Extruder Controls ExtruVision S

RXTH DUAL ROOM SENSOR / SWITCH

TM241CE24U controller M IO transistor NPN Ethernet

APP 700 Technical Specification

Modular controllers CECX

TM221CE40T controller M IO transistor PNP Ethernet

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TM221CE24T controller M IO transistor PNP Ethernet

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

TM241CE40R controller M IO relay Ethernet

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

TM3TI4 module TM3-4 inputs temperature

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

iopac 8500 Series Rugged modular RTU controllers Overview Programmable Controllers High Sampling Rate Analog Input Prerecord Feature

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

EY-EM : Remote I/O module, ecolink

Transcription:

IMIO100 IMIO105 DDC controllers Summary DDC (Direct digital control) controller IMIO100 and IMIO105 are free programmable process stations with ARM Cortex M4 processor and OS FreeRTOS. They contain one Ethernet port, 4 AI, 4 DI, 2 AO and 6 DO. IMIO105 contains also a RS485 interface and 8 MB more RAM. IMIO100 is suitable for control of small installations (up to about 30 physical data points) compared to IMIO105 which is suitable for control of larger installation (approximately 150 physical data points). Application Free programmable control units for HVAC systems and other applications with web access Data acquisition, processing, and presentation systems with advanced networking features Protocol converters with web data presentation (must be programmed by user) Function The controller hosts an embedded FreeRTOS operating system which boots up the Merbon runtime with the application. The board contains real time clock with battery backup, flash memory containing OS, runtime, application, and other data (time programs, setpoints etc.), and a watchdog. It is also possible to use NVRAM to backup parameters in case of unexpected system shutdown. The application is created and uploaded in the Merbon IDE development environment. The maximum application program size depends on number of physical and software data points, amount of function blocks which require more memory (e.g. time schedulers), degree of code optimisation, and number of connections the PLC has to handle. domat IMIO100, IMIO105 11/2017 Subject to technical changes. 1

For communication with other devices, IMIO100 contains an Ethernet port. I/Os integrated on the board are 4 AI, 2 AO, 4 DI and 6 DO. The IMIO105 contains one Ethernet port and one RS485 interface for I/O module extension, with the same onboard I/O mix as the IMIO100. Consider that IMIO100 is originally intended to control its own inputs and outputs. IMIO105 has sufficient computing power to control larger installation with external I/O modules and communication channels (for example Modbus TCP server, SSCP client, ). The process station contains a web server for remote connection and user intervention. The web pages are created in Merbon HMI editor, which is included in the package of development programs. The exported web definition is uploaded to the process station through Merbon IDE (see Web definition in PLC properties). The module is 105 mm wide and mounts on a standard DIN rail. Technical data Power 24 V AC/DC ± 20 %; max 5 VA Communication - IMIO100 Ethernet 1x Ethernet 10/100BaseT RJ45, 2 LED (link, data) integrated in the connector Communication - IMIO105 Ethernet RS485 1x Ethernet 10/100BaseT RJ45, 2 LED (link, data) integrated in the connector COM1 RS485 (K+, K-) galvanically insulated, insulating voltage 1 kv 300... 115 200 bit/s, parity and bits are set in software maximal bus length 1200 m maximum number of modules depends on requested response time up to 255 addresses, for common HVAC applications with IMIO105 use about 150 physical data points on the bus 3x LED RUN, TxD, PWR Analogue inputs Number 4 Resistance measuring range 0...1600 Ohm, 0...5000 Ohm, Pt100, Pt500, Pt1000, Ni1000-5000, Ni1000-6180... sensors (transformation is done in the runtime application), settings see in Terminals -> Jumpers Measuring current in the passive mode (0...1600 Ohm): 200 µa at 100 % of the time. 2 11/2017 Subject to technical changes. domat IMIO100, IMIO105

Voltage measuring range Only AI3, AI4: 0...10 V DC (settings see in Terminals -> Jumpers) Current measuring range Resolution Galvanic insulation Only AI3, AI4: with an external resistor of 125 Ohm as 0..20 ma 16 bit Optically insulated up to 1 kv. Analogue outputs Number 2 Voltage range 0 10 V DC Analogue outputs load Resolution Galvanic insulation min. 10 k outputs are protected against permanent short-circuit 20 ma limitation 8 bit Optically insulated up to 1 kv. Digital inputs Number 4 Voltage Input current Maximal voltage Galvanic insulation 24 V AC/DC voltage must be applied (no dry contacts), e.g. from G and G0 4 ma 60 V DC, 40 V AC Optically insulated up to 1 kv. Digital outputs Number Relay load Solid state relay load Galvanic insulation 4 relays, normally open 2 solid state relays 5 A at 250 V AC, 1250 VA 5 A at 30 V DC, 150 W For AC and DC load, 24 V DC/AC, maximum current 0,4 A Recommended thermic actuators are STA71 (Siemens), TWA (the 24 V types, Danfoss). Optically insulated up to 1 kv. HW IMIO100 ARM Cortex M4 168 MHz, 10 MB FLASH, 256 KB SRAM, 4 KB NVRAM HW IMIO105 ARM Cortex M4 168 MHz, 10 MB FLASH, 256 KB + 8 MB SRAM, 4 KB + 64 KB NVRAM domat IMIO100, IMIO105 11/2017 Subject to technical changes. 3

SW Merbon IDE (supported from version ER2 2.2.0.0) Merbon HMI Housing Dimensions Polycarbonate box (certification UL94V0) See the schema below. Protection degree IP21 (EN 60529) Terminals Ambient conditions Standards regarding conformity EU legislation Power, RS485, DO: screw terminals M3, maximum wire cross-section 2,5 mm 2 AO/AI/DI: screw terminals M2, maximum wire crosssection 1,5 mm 2 5 40 C; 5 85 % relative humidity; non-condensing gases and chemically non-aggressive conditions (according to EN 60721-3-3 climatic class 3K3) EMC EN 61000-6-2 ed.3:2005, EN 55022 ed.3:2010 EN 60950-1 ed.2:2006 + A11:2009 + A12:2011 + A1:2010 + A2:2014 EN 50581:2012 Council Directive 2006/95/EC, health and low voltage equipment safety Council Directive 2004/108/EC, electromagnetic compatibility Council Directive 2011/65/EC, certain hazardous substances in electrical and electronic equipment Terminals 4 11/2017 Subject to technical changes. domat IMIO100, IMIO105

Terminals and connectors: DO1 DO4 relay output 1 4, normally open against C1 C4 C1 C4 relay output 1 4, ground DO5, DO6 SSR outputs 5 and 6, normally open against C56 C5, C6 SSR output 5 a 6, ground (common) DI1 4 digital inputs 1 4 G power G0 power TE optional connection for shielding AI1 4 analogue input 1 AIC analogue input ground (common) Notice: All analogue inputs AI1 to AI4 have common ground AIC. The inputs are optically separated from the other parts of the I/O module. For three-wire connection (active sensors, e.g. pressure, humidity), the analogue input ground AIC must be connected with the peripheral 24 V AC power ground. As all I/O types are mutually separated in the module, it is possible to use one common transformer to power both the active peripherals and the IMIO module AO1, AO2 analogue outputs 1 and 2 AOC analogue outputs ground (common) Notice: The ground is optically separated from the other parts of the I/O module. For three-wire connection (active periphery, e.g. valves actuators, frequency changer), the analogue output ground AOC must be connected with the peripheral 24 V AC power ground. As all I/O types are mutually separated in the module, it is possible to use one common transformer to power both the active peripherals and the IMIO module RS485 port COM1 serial line RS485, terminals K+, K- (IMIO105 only) Ethernet network interface LED indication: RUN yellow LED system cycle (OK: LED flashes periodically 1 s ON, 1 s OFF; ERROR: LED flashes in other pattern, LED is permanently ON or OFF) TxD red LED transmitting data at COM1 (flashing: receiving data; still ON: shortcircuited or overload bus) PWR green LED power (ON: power OK; OFF: no power applied, weak or damaged power supply, ) DIP switches: STOP INIT if ON runtime is running, program execution is stopped if ON at power-up, configuration parameters are brought to defaults (see Configuration parameters in Merbon IDE; domat IMIO100, IMIO105 11/2017 Subject to technical changes. 5

BUS END Jumpers: e.g. IP address, user and password, database settings, proxy, ) DIP3 and DIP4 both ON = bus end RS485; the first and last devices on bus should have bus end ON (IMIO105 only) The jumpers are available after the AI terminals are removed. Default setting is resistance (passive temperature) measuring. Change the settings for voltage range (see table below). Take out the jumper and plug in an external resistor of 125 Ohm between terminals AI3- AIC or AI4-AIC for 0...20 ma range. The settings is valid only for AI3 and AI4, other analogue inputs are for resistance only! (Jumpers numbered from the left.) Resistance (temperature) Voltage AI3 J1=OFF, J2=ON J1=ON, J2=OFF AI4 J3=OFF, J4=ON J3=ON, J4=OFF Connection 6 11/2017 Subject to technical changes. domat IMIO100, IMIO105

Dimensions Dimensions are in mm. Programming Merbon IDE The main programming tool is the Merbon package which contains I/O editor, graphical editor of the function plan (FBD), structure text editor and compiler (Merbon IDE). The Merbon package contains also LCD menu editor as well as web editor (Merbon HMI). The application program consists of function blocks which are stored in libraries. Those contain analogue and digital functions, mathematical blocks including goniometric functions, time schedulers, alarm blocks, and HVAC specific blocks (heat recovery, dewpoint calculation, enthalpy, pump switch etc.). The program can be set up also as structure text (ST) or with combination of both types of programming languages. Communication Default network settings are: IP address 192.168.1.10 subnet mask 255.255.255.0 default gateway 192.168.1.1 SSCP user: admin Password: rw Notice: Do not forget to record the new network settings after change! After these values have been changed, it is possible to bring the process station into default settings by the INIT DIP switch: set INIT to ON and restart the station. domat IMIO100, IMIO105 11/2017 Subject to technical changes. 7

All values in the PLC configuration are set to defaults. The PLC will respond at the default IP address and it is possible to change the old address through Merbon IDE. The controllers can share variables over the Ethernet network (outside temperature, heat demands etc.) together with other PLC platforms. The runtime provides drivers for communication with subsystems. Merbon runtime contains e.g. Modbus TCP / RTU (server/client), M-Bus, IEC62056-21, SSCP, and SoftPLC link. The complete list of drivers can be found in the Channel configuration dialogue in the most recent Merbon release. Please check the required protocol features and functions with the list of implemented features in the Merbon IDE help. It is also possible to program own communication drivers using the I/O library functions in structure text language. Number of communication channels (on the serial lines and Ethernet) to I/O modules and subsystems is not directly restricted. It depends on available RAM PLC memory. Number of connections from SSCP clients is max. 5. This includes connections from RcWare Vision, Merbon IDE, HT102/200, mobile application Merbon Menu Reader, connection from other PLCs over SSCP etc. Number of connections from Modbus TCP clients on Modbus TCP server is max. 5. Other clients channels (web etc.) are not directly restricted. RoHS notice Safety note The device contains a non-rechargeable battery which backups the real-time clock and part of the memory. After the device is not operable, please return it to the manufacturer or dispose of it in compliance with local regulations. The device is designed for monitoring and control of heating, ventilation, and air conditioning systems. It must not be used for protection of persons against health risks or death, as a safety element, or in applications where its failure could lead to physical or property damage or environmental damage. All risks related to device operation must be considered together with design, installation, and operation of the entire control system which the device is part of. 8 11/2017 Subject to technical changes. domat IMIO100, IMIO105

Changes in versions 05/2016 First version. 07/2016 Added information about new communication drivers and communication limits. Corrected information about function of STOP DIP switch. 08/2016 Corrected information about DO5 and DO6. These outputs do not switch at zero. 01/2017 Jumpers: 0..20 ma range description enhanced. 07/2017 Added terminals connection scheme. 11/2017 Added safety note, passive sensor connection information and power tolerance. domat IMIO100, IMIO105 11/2017 Subject to technical changes. 9