Level instruments. Point level measurement - Capacitance switches. Pointek CLS200 5/15. Overview. Configuration

Similar documents
Level instruments. Point level measurement - Capacitance switches. Pointek CLS300 5/31

Selection and Ordering data. Selection and Ordering data

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Continuous level measurement Radar transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters

Capacitance level switches LS 210 LS 220

Configuration. Installation

Siemens AG Level Measurement

Siemens AG Continuous level measurement Radar transmitters. Configuration. Installation

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transducers

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Continuous level measurement Radar transmitters

Continuous level measurement Ultrasonic transducers

Flow Measurement SITRANS F M

Continuous level measurement Ultrasonic transducers

Level limit switch Series RF 3000 Selection list. Overview 2

Level instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.

SITRANS L Level instruments

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Continuous level measurement Ultrasonic transducers

Flow Measurement SITRANS F M

NIVOSWITCH VIBRATING FORK LEVEL SWITCHES

FOR LIQUIDS AND SOLIDS

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

Flow Measurement SITRANS F US Inline

Assembly. Function 41

Level Measurement. Continuous level measurement - Ultrasonic controllers. SITRANS LU01 and LU02. 5/156 Siemens FI Overview.

Level Measurement Continuous level measurement Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers

Flow Measurement SITRANS F M. Transmitter MAG 5000/ /34 Siemens FI Overview

PROFIBUS-PA Positioner Type 3785

Flow Measurement SITRANS F C

Flow Measurement SITRANS F US Inline

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

Siemens AG Continuous level measurement Ultrasonic controllers

LS 5000 series Vibration Level Switch for liquids

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

Float Switches with Permanent Magnet For Vertical Installation Model RSM

CAPACITIVE: CONTROL CLS2 CLS4 CLS5. Applications liquids / solids liquids / solids solids / granules

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

Level Measurement Continuous level measurement - Ultrasonic controllers

Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

5 Fieldbus Technology

Level instruments. Continuous level measurement - Ultrasonic controllers SITRANS LUC500. 5/146 Siemens FI

Liquipoint T FTW31, FTW32

Series 3730 Electropneumatic Positioner Type

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

Continuous level measuring system NB 3000 Selection list

Series 3730 Type Electropneumatic Positioner

Safety Instructions Levelflex FMP50/51/52/53/54/55/56/57

SITRANS F flowmeters SITRANS F US

PI-EX-ME-2NAM/COC-24VDC

Spare Parts for RM71 SmartLine Guided Radar Level Meter

Level measurement. Applications. Special features. Description

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

Continuous level measurement Ultrasonic controllers

Quick Start Manual April English Dansk Deutsch. Español Français Italiano Nederlands Português Suomi Svenska. sitrans LG200

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Level Measurement Continuous level measurement Ultrasonic controllers

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Temperature Measurement SITRANS TS300

KINAX WT720 absolute, programmable angular postion transmitter

PI-EX-ME-2NAM/COC-120VAC

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2

3/2 Directional control valves Direct solenoid operated poppet valves Internal thread G 1/2, 1/2 NPT or flanged with NAMUR interface

LS 6600 Technical Datasheet

OPTISWITCH 6600 C Technical Datasheet

Technical Data. General specifications. Rated operating distance s n 3 mm

Capacitive. Overview 116 VEGACAP series VEGACAP 27, 35, Capacitive VEGACAP

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Flow Measurement SITRANS F US Clamp-on

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Level measurement CleverLevel LBFI Point level detection

PHOENIX CONTACT - 12/2007

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

General Specifications

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Flow Measurement SITRANS F C

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Technical Information Promonitor NRF560

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Magnetic float switch For vertical installation Model FLS

HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters

Signet 2552 Metal Magmeter Flow Sensors

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

26360, Inline. Technical data. Ordering information See page 2. For connector plugs see page 2 and data sheets N/en /2 5/2.

T EN TROVIS Electropneumatic Positioner

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Transcription:

Level instruments Overview Configuration is a versatile inverse frequency shift capacitance level slurries, foam and interfaces. The digital version (with PROFIBUS PA) includes a display and provides additional diagnostic features. Benefits Potted construction protects signal circuit from shock, vibration, humidity and/or condensation High chemical resistance Level detection independent of tank or pipe earth reference Insensitive to product buildup due to high frequency oscillation High sensitivity allows installation in a wide range of liquids, solids or slurry applications Integral LCD display allows for easy setup of CLS200 when you can configure switching threshold, even under the most demanding process conditions (digital version only) Extended rod, cable and sanitary versions available Standard version: 3 LED indicators for sensor status, output status and power SIL/IEC6108 compliant for use in safety integrated level applications for overfill protection (SIL-2) Digital version: integral LCD display, and PROFIBUS PA communication Application The is offered in standard and digital versions. The standard version has 3 LED indicators with basic relay and solid-state switch alarms. The digital version provides an integral LCD display for standalone use, and also provides PROFIBUS PA communication (Profile version 3.0 (P caps)) for connection to a network. The power supply is galvanically isolated and accepts a wide range of voltages (12 to 20 V AC/DC for standard version and 12 to 30 V DC for digital version). The stainless steel and PPS (PVDF optional) materials used in the probe construction provide a temperature rating up to +12 C (+27 F) on the process wetted portion of the probe. The switch responds to any material with a dielectric constant of 1. or more by detecting a change in oscillating frequency, and it can be set to detect before contact or on contact with the probe.the CLS200 operates independently of the tank wall or pipe so it does not require an external reference electrode for level detection in a non-conductive vessel such as concrete or plastic. Key Applications: liquids, slurries, powders, granules, pressurized applications, hazardous areas installation Siemens FI 01 2009 /1

Level instruments Technical specifications (Note: all specifications listed below apply to Standard and Digital versions unless otherwise noted) Mode of operation Measuring principle Inverse frequency shift capacitive level detection Input Measured variable Change in picofarad (pf) Output Output signal (CLS200 Standard) Relay output 1 SPDT Form C relay - Max. contact voltage 30 V DC 20 V AC - Max. contact current A (DC) 8 A (AC) - Max. switching capacity 10 W (DC) 2000 VA (AC) - Time delay (ON and/or OFF) 1 to 60 s Solid-state output - Output Galvanically isolated - Protection Against reversed polarity (bipolar) - Max. switching voltage 30 V (DC) 30 V peak (AC) - Max. load current 82 ma - Voltage drop < 1 V, typical at 0 ma - Time delay (pre or post switching) 1 to 60 s Output signal (CLS200 Digital) Solid-state output (CLS200 Digital) - Output Galvanically isolated - Protection Against reversed polarity (bipolar) - Max. switching voltage 30 V (DC) 30 V peak (AC) - Max. load current 82 ma - Voltage drop < 1 V, typical at 0 ma - Time delay (ON and/or OFF) Programmable by user (0 to 100 s) Fail-safe mode Min. or max. Connection Removable terminal block Rated operating conditions 1) Installation conditions Location Indoor/outdoor Ambient conditions Ambient temperature -40 to +8 C (-40 to +18 F) Installation category II Pollution degree 4 Medium conditions Liquids, bulk solids, slurries and interfaces Relative dielectric constant ε r Min. 1. Temperature at process connection - Standard -40 to +8 C (-40 to +18 F) - Standard with thermal isolator -40 to +12 C (-40 to +27 F) Pressure (standard version and -1 to +2 bar g/ versions with extension) 2) -14.6 to +36 psi g (nominal) Pressure (cable version) -1 to +10 bar g/ -14.6 to +10 psi g (nominal) Pressure (optional sliding coupling version) Design Material -1 to +10 bar g/ -14.6 to +10 psi g (nominal) - Enclosure Epoxy-coated aluminum with gasket - Optional thermal isolator 316L stainless steel Connection Removable terminal block, max. 2. mm² Degree of protection IP6/Type 4/NEMA 4 (optional IP68) Cable inlet 2 x M20x1. thread (option: 2 x ½" NPT conduit entry including 1 plugged entry), digital version has optional PROFIBUS PA connector Power supply (CLS200 Standard) 12 to 20 V AC/DC, 0 to 60 Hz max. 2 W Power supply (CLS200 Digital) Bus voltage Standard: 12 to 30 V DC Intrinsically Safe: 12 to 24 V DC Current consumption 12. ma Certificates and approvals (CLS200 Standard) General Purpose CE, CSA, FM Dust Ignition Proof (Intrinsically Safe probe circuit) Dust Ignition Proof (Cable version Intrinsically Safe probe) Explosion Proof (Intrinsically Safe probe circuit) Marine Overfill Protection Others CSA/FM Class II and III, Div. 1, Groups E, F, G T4 ATEX II 1/2 D T100 C CSA/FM Class I, Div. 1, Groups A, B, C, D T4 ATEX II 1/2 G EEx d[ia] IIC T6 to T4 Lloyds Register of Shipping, Categories ENV1, ENV2 and ENV WHG (Germany) SIL/IEC6108 Declaration of Conformity [SIL-2 (overspill)] Pattern Approval (China) C-TICK (Australia) Certificates and approvals (CLS200 Digital) General Purpose CE, CSA, FM Intrinsically Safe CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, E, F, G T4 or T6 3) ATEX II 1G 1/2D EEx ia IIC T6 to T4 T100 C 3) Explosion Proof/Dust Ignition Proof (Intrinsically Safe probe circuit) Non-incendive/Non-sparking Marine Others CSA/FM Class I, II, and III, Div. 1, Groups A, B, C, D, E, F, G T4 ATEX II 1/2G EEx d[ia] IIC T6 to T4 ATEX II 1/2D T100 C CSA/FM Class I, Div. 2, Groups A, B, C, D T4 or T6 CSA/FM Class II and III, Div. 2, Groups F, G ATEX II 3G 2D EEx na II T6 to T4 T100 C Lloyds Register of Shipping, Categories ENV1, ENV2 and ENV Pattern Approval (China) C-TICK (Australia) /16 Siemens FI 01 2009

Communication (CLS200 Digital) 1) 2) 3) PROFIBUS PA (IEC 6118 CPF3 CP3/2) Bus physical layer: IEC 6118-2 MBP (IS) Device profile: PROFIBUS PA profile for Process Control Devices Version 3.0, Class B FISCO field device When operation is in areas classified as hazardous, observe restrictions according to relevant certificate. See also Pressure/Temperature curves on page /24. Pressure rating of process seal is temperature dependent. See Pressure/Temperature curves on page /24. Barrier required for Intrinsically Safe protection Level instruments Standard version Sanitary version Cable version Max. length. m (18 ft). m (18 ft) 30 m (98 ft) liquids and slurries m (16 ft) solids (under loads) Process connection R ¾", 1", 1¼", 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¾", 1", 1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] G ¾", 1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 316L stainless steel ASME/EN flange 1) PFA coating (7ML0) has 120 micron thickness 2) FFKM available as special option. Contact nacc.smpi@siemens.com for details. 3) Thermal isolator is used if process connection temperature exceeds +30 C (+8 F). 1½", 2" sanitary fitting clamp 316L stainless steel R ¾", 1", 1¼", 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] ¾", 1", 1¼", 1½" NPT [(Taper), ANSI/ASME B1.20.1] G ¾", 1", 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] 316L stainless steel ASME/EN flange Extension material 316L stainless steel optional PFA coated 1) 316L stainless steel Fluoroethylene propylene (FEP) cable with stainless steel core Sensor wetted parts PPS (optional PVDF) PPS (optional PVDF) PPS (optional PVDF) O-ring seal material 2) FKM FKM FKM Thermal isolator 3) Optional Optional Optional Extension User selected length User selected length Cable extension Siemens FI 01 2009 /17

Level instruments, threaded/sanitary version C) 7 M L 0 2 - Versatile inverse frequency shift capacitance level 7 7777-0 7 7 7 slurries, foam and interfaces Note: To select Standard or Digital CLS200 (with PROFIBUS PA), see final place holder under Electronics/output. Probe version (Threaded lengths include process thread) 1) 2) Compact,120 mm (4.72") 0 X 1) 2) Extended rod, 20 mm (9.84") 1 A Extended rod, 30 mm (13.78") 1) 3) 1 B Extended rod, 00 mm (19.69") 1) 3) 1 C 1) 3) Extended rod, 70 mm (29.3") 1 D 1) 3) Extended rod, 1000 mm (39.37") 1 E Add order code Y01 and plain text: Insertion length... mm" - Extended rod, 200 to 999 mm (7.87 to 39.33") 4) 1 F - Extended rod, 1001 to 2000 mm 1 G (39.41 to 78.74") 3) - Extended rod, 2001 to 3000 mm 1 H (78.78 to 118.11") 3) ) - Extended rod, 3001 to 4000 mm 1 J (118.1 to 17.48") 3) ) - Extended rod, 4001 to 000 mm 1 K (17.2 to 196.8") 3) ) - Extended rod, 001 to 00 mm 1 L (196.89 to 216.3") 3) ) Extended cable, 3000 mm (118.11"), length adjustable by customer 2 A 1) 2) Extended cable, 6000 mm (236.22"), length adjustable by customer1) 2) 2 B Add order code Y01 and plain text: Insertion length... mm" - Extended cable, 00 to 4999 mm 2 C (19.69 to 196.81") 2) - Extended cable, 000 to 9999 mm 2 D (196.8 to 393.66") 2) - Extended cable, 10000 to 14999 mm 2 E (393.7 to 90.") 2) - Extended cable, 1000 to 19999 mm 2 F (90.6 to 787.4") 2) - Extended cable, 20000 to 24999 mm 2 G (787.4 to 894.3") 2) - Extended cable, 2000 to 29999 mm 2 H (984.3 to 1181.1") 2) 1) 2) 6) Sanitary compact, 98 mm (3.8") 3 A Add order code Y01 and plain text: Insertion length... mm" - Sanitary extended, 110 to 1000 mm 3 B (4.3 to 39.3") 2) 7) - Sanitary extended, 1001 to 2000 mm 3 C (39.4 to 78.7") 2) 7) - Sanitary extended, 2001 to 3000 mm 3 D (78.8 to 118.1") 2) ) 7) - Sanitary extended, 3001 to 4000 mm 3 E (118.1 to 17.") 2) ) 7) - Sanitary extended, 4001 to 000 mm 3 F (17. to 196.9") 2) ) 7) - Sanitary extended, 001 to 00 mm 3 G (196.9 to 216.") 2) ) 7), threaded/sanitary version Versatile inverse frequency shift capacitance level C) 7 M L 0 2-7 7777-0 7 7 7 slurries, foam and interfaces Process connection ¾" NPT [(Taper), ANSI/ASME B1.20.1] A 1" NPT [(Taper), ANSI/ASME B1.20.1] B 1½" NPT [(Taper), ANSI/ASME B1.20.1] C R ¾" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] D R 1" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] E R 1½" [(BSPT), EN 10226/PT (JIS-T), JIS B 0203] F 1¼" NPT [(Taper), ANSI/ASME B1.20.1] K G ¾" [(BSPP), EN ISO 228-1/PF (JIS-P), L JIS B 0202] G 1" [(BSPP), EN ISO 228-1/PF (JIS-P), JIS B 0202] M G 1½" [(BSPP), EN ISO 228-1/PF (JIS-P), N JIS B 0202] 1" sanitary fitting clamp 8) 9) R 1½" sanitary fitting clamp 8) 9) S 2" sanitary fitting clamp 8) 9) T 2½" sanitary fitting clamp 8) 9) V 3" sanitary fitting clamp 8) 9) W Approvals General Purpose 1 CSA/FM Class II and III Div. 1, Groups E, F, G T4 10) 2 FM Class I Div. 1, Groups A, B, C, D T4 10) 3 CSA Class I, Div. 1, Groups A, B, C, D T4 10) 4 ATEX II 1/2 D T 100 C 10) ATEX II 1/2 G EEx d [ia] IIC T6 to T4 10) 6 CSA/FM Class I, Div 2, Groups A, B, C, D T4 or T6; 7 CSA/FM Class II and III, Div. 2, Groups F, G T4 or T6; ATEX II 3G 2D EEx na II T6 to T4 T100 C 6) CSA/FM Class I, II and III, Div 1, Groups A, B, C, D, 8 E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4 6) 11) T100 C CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0 E, F, G T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4 T100 C 6) Enclosure (see also option A01) Aluminum epoxy coated 2 x ½" NPT via adapter, cable inlet, IP6 0 2 x M20x1. cable inlet, IP6 1 2 x ½" NPT via adapter, cable inlet, IP68 2 2 x M20x1. cable inlet, IP68 3 Additional options Standard version (PPS probe body) A With thermal isolator (PPS probe body) B With PVDF probe body C With thermal isolator and PVDF probe body D With sliding coupling (PPS probe body) E With thermal isolator and sliding coupling F With sliding coupling and PVDF probe body G With thermal isolator, sliding coupling and PVDF H probe body WHG approval, German overfill protection Not required A Required 10) B Electronics/output Standard version without display, 12 to 20 V AC/DC, solid-state and relay output 12) 0 Digital version with display, 24 V DC, solid-state output or PROFIBUS PA 12) 13) 1 /18 Siemens FI 01 2009

Level instruments, threaded/sanitary version C) 7 M L 0 2 - Versatile inverse frequency shift capacitance level 7 7777-0 7 7 7 slurries, foam and interfaces Further designs Please add -Z" to and specify Order code(s). Order code Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 38 mm (2.7 x 1.")]: Measuring-point number/identification (max. 20 charac- Y1 ters); specify in plain text Electrical connection/cable inlet: PROFIBUS PA A01 6) 14) 1) connector M12 Optional enclosure lid: Lid with glass window A04 instead of closed lid without window10) 12) Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 10204 C12 SIL/IEC6108 Declaration of Conformity [SIL-2 C20 (overspill)] 10) Remote Electronics Remote mounted electronics with 2 m (79") cable A0 Remote mounted electronics with m (197") cable A06 Mounting bracket (including mounting kit) for remote electronics A09 Instruction manual See page /23 Note: The instruction manual should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. Accessories See page /23 1) No Y01 needed in order code 2) Available with additional options A to D only 3) Available with additional options A to H 4) Lengths <30 mm (13.78") available with additional options A to D only ) Custom shipping methods required. Contact factory for more details. 6) Available with electronics option 1 only 7) Available with process connection R to W only 8) Available with version 3A to 3G only 9) Sanitary connection dimensionally corresponds to the applicable ISO 282 standard 10) Available with electronics option 0 only 11) Barrier required for Intrinsically Safe protection 12) Version with electronics option 0 has a closed lid without window as default; version with electronics option 1 has a lid with glass window as default. 13) An M12 PROFIBUS PA connector can be selected separately with wildcard option (A01). 14) Available with enclosure option 1 only 1) Available with approval option 1, 7, and 8 only C) Subject to export regulations AL: N, ECCN: EAR99 Siemens FI 01 2009 /19

Level instruments, welded flange C) 7 M L 0 4 - Versatile inverse frequency shift capacitance level 7 7 7 77-77 7 7 slurries, foam and interfaces. Note: To select Standard or Digital CLS200 (with PROFIBUS PA), see final place holder under Electronics/output Probe version (length from flange face) Compact, 98 mm (3.86") 2) 0 X Extended rod, 20 mm (9.84") 2) 1 A Extended rod, 30 mm (13.78") 2) 1 B Extended rod, 00 mm (19.69") 2) 1 C Extended rod, 70 mm (29.3") 2) 1 D Extended rod, 1000 mm (39.37") 2) 1 E Add order code Y01 and plain text: Insertion length... mm" - Extended rod, 200 to 999 mm (7.87 to 39.33") 1 F - Extended rod, 1001 to 2000 mm 1 G (39.41 to 78.74") - Extended rod, 2001 to 3000 mm 1 H (78.78 to 118.11") 1) - Extended rod, 3001 to 4000 mm 1 J (118.1 to 17.48") 1) - Extended rod, 4001 to 000 mm 1 K (17.2 to 196.8") 1) - Extended rod, 001 to 00 mm 1 L (196.89 to 216.3") 1) Extended cable, 3000 mm (118.1"), length adjustable by customer 2) 2 A Extended cable, 6000 mm (236.2"), length adjustable by customer 2) 2 B Add order code Y01 and plain text: Insertion length... mm" - Extended cable, 00 to 4999 mm 2 C (19.69 to 196.81") - Extended cable, 000 to 9999 mm 2 D (196.8 to 393.66") - Extended cable, 10000 to 14999 mm 2 E (393.7 to 90.") - Extended cable, 1000 to 19999 mm 2 F (90.6 to 787.4") - Extended cable, 20000 to 24999 mm 2 G (787.4 to 894.3") - Extended cable, 2000 to 29999 mm 2 H (984.3 to 1181.1") Process connection Welded flange, 316L stainless steel, raised face 1" ASME, 10 lb A 1 1" ASME, 300 lb A 2 1" ASME, 600 lb A 3 1½" ASME, 10 lb B 1 1½" ASME, 300 lb B 2 1½" ASME, 600 lb B 3 2" ASME, 10 lb C 1 2" ASME, 300 lb C 2 2" ASME, 600 lb C 3 3" ASME, 10 lb D 1 3" ASME, 300 lb 1) D 2 3" ASME, 600 lb 1) D 3 4" ASME, 10 lb 1) E 1 4" ASME, 300 lb 1) E 2 4" ASME, 600 lb 1) E 3, welded flange C) 7 M L 0 4 - Versatile inverse frequency shift capacitance level 7 7 7 77-77 7 7 slurries, foam and interfaces. Welded flange, 316L stainless steel, Type A flat faced DN 2, PN 16 J 4 DN 2, PN 40 J 6 DN 40, PN 16 K 4 DN 40, PN 40 K 6 DN 0, PN 16 L 4 DN 0, PN 40 L 6 DN 80, PN 16 M 4 DN 80, PN 40 1) M 6 DN 100, PN 16 1) N 4 DN 100, PN 40 1) N 6 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16., or EN 1092-1 standard.) Approvals General Purpose 1 CSA/FM Class II and III Div. 1, Groups E, F, G T4 3) 2 FM Class I Div. 1, Groups A, B, C, D T4 3) 3 CSA Class I, Div. 1, Groups A, B, C, D T4 3) 4 ATEX II 1/2 D T100 C 3) ATEX II 1/2 G EEx d [ia] IIC T6 to T4 3) 6 CSA/FM Class I, Div 2, Groups A, B, C, D T4 or T6; 7 CSA/FM Class II and III, Div 2, Groups F, G T4 or T6; ATEX II 3G 2D EEx na II T6 to T4 T100 C 4) CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 8 E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4 4) ) T100 C CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0 E, F, G, T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4 T100 C 4) Enclosure (see also option A01) Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP6 0 2 x M20x1. cable inlet, IP6 1 2 x ½" NPT via adapter - cable inlet, IP68 2 2 x M20x1. cable inlet, IP68 3 Additional options Standard version (PPS probe body) A With thermal isolator (PPS probe body) B With PVDF probe body C With thermal isolator and PVDF probe body D WHG approval, German overfill protection Not required A Required 3) B Electronics/output Standard version without display, 0 12 to 20 V AC/DC, solid-state and relay output 6) Digital version with display, 24 V DC, solid-state 1 output or PROFIBUS PA 6) 7) /20 Siemens FI 01 2009

Level instruments, welded flange C) 7 M L 0 4 - Versatile inverse frequency shift capacitance level 7 7 7 77-77 7 7 slurries, foam and interfaces. Further designs Order code Please add -Z" to and specify Order code(s). Total insertion length: enter the total Y01 insertion length in plain text description Stainless steel tag [69 x 38 mm (2.7 x 1.")]: Measuring-point number/identification (max. 20 charac- Y1 ters); specify in plain text Electrical connection/cable inlet: PROFIBUS PA A01 4) 8) 9) connector M12 Optional enclosure lid: Lid with glass window A04 instead of closed lid without window 6) Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 10204 C12 SIL/IEC6108 Declaration of Conformity [SIL-2 C20 (overspill)] 3) Remote Electronics Remote mounted electronics with 2 m (79") cable A0 Remote mounted electronics with m (197") cable A06 Mounting bracket (including mounting kit) for remote electronics A09 Instruction manual See page /23 Note: The instruction manual should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. Accessories See page /23 1) Custom shipping methods required. Contact factory for more details. 2) No Y01 needed in order code 3) Available with electronics option 0 only 4) Available with electronics option 1 only ) Barrier required for Intrinsically Safe protection 6) Version with electronics option 0 has a standard closed lid without window as default; version with electronics option 1 has a standard lid with glass window as default. 7) An M12 PROFIBUS PA connector can be selected separately with wildcard option (A01). 8) Available with enclosure option 1 only 9) Available with approval option 1, 7, and 8 only C) Subject to export regulations AL: N, ECCN: EAR99 Siemens FI 01 2009 /21

Level instruments, welded flange, PFA coated Versatile inverse frequency shift capacitance level C) 7 M L 0-7 7 7 77-77 7 7 slurries, foam and interfaces. Note: To select Standard or Digital CLS200 (with PROFIBUS PA), see final place holder under Electronics/output Probe version (length from flange face) Compact, 98 mm (3.86") 1) 0 X Extended rod, 20 mm (9.84") 1) 1 A Extended rod, 30 mm (13.78") 1) 1 B Extended rod, 00 mm (19.69") 1) 1 C Extended rod, 70 mm (29.3") 1) 1 D Extended rod, 1000 mm (39.37") 1) 1 E Add order code Y01 and plain text: Insertion length... mm" - Extended rod, 200 to 999 mm (7.87 to 39.33") 1 F - Extended rod, 1001 to 2000 mm 1 G (39.41 to 78.74") - Extended rod, 2001 to 3000 mm (78.78 to 118.11") 2) 1 H - Extended rod, 3001 to 4000 mm (118.1 to 17.48") 2) 1 J - Extended rod, 4001 to 000 mm (17.2 to 196.8") 2) 1 K - Extended rod, 001 to 00 mm (196.89 to 216.3") 2) 1 L Process connection Welded flange, 316L stainless steel, raised face, PFA coated 1" ASME, 10 lb A 1 1" ASME, 300 lb A 2 1" ASME, 600 lb A 3 1½" ASME, 10 lb B 1 1½" ASME, 300 lb B 2 1½" ASME, 600 lb B 3 2" ASME, 10 lb C 1 2" ASME, 300 lb C 2 2" ASME, 600 lb C 3 3" ASME, 10 lb D 1 3" ASME, 300 lb 2) D 2 3" ASME, 600 lb 2) D 3 4" ASME, 10 lb 2) E1 4" ASME, 300 lb 2) E2 4" ASME, 600 lb 2) E3 Welded flange, 316L stainless steel, Type A flat faced, PFA coated DN 2, PN 16 J4 DN 2, PN 40 J6 DN 40, PN 16 K4 DN 40, PN 40 K6 DN 0, PN 16 L4 DN 0, PN 40 L6 DN 80, PN 16 M4 DN 80, PN 40 2) M6 DN 100, PN 16 2) N4 DN 100, PN 40 2) N6 (Note: Flange bolting patterns and facings dimensionally correspond to the applicable ASME B16. or EN 1092-1 standard.), welded flange, PFA coated C) 7 M L 0 - Versatile inverse frequency shift capacitance level 7 7 7 77-77 7 7 slurries, foam and interfaces. Approvals General Purpose 1 CSA/FM Class II and III Div. 1, Groups E, F, G T4 3) 2 FM Class I Div. 1, Groups A, B, C, D T4 3) 3 CSA Class I, Div. 1, Groups A, B, C, D T4 3) 4 ATEX II 1/2 D T100 C 3) ATEX II 1/2 G EEx d [ia] IIC T6 to T4 3) 6 CSA/FM Class I, Div 2, Groups A, B, C, D T4 or T6; 7 CSA/FM Class II and III, Div 2, Groups F, G; ATEX II 3G 2D EEx na II T6 to T4 T100 C 4) CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 8 E, F, G T4 or T6; ATEX II 1G 1/2D EEx ia IIC T6 to T4 T100 C4) ) CSA/FM Class I, II and III, Div. 1, Groups A, B, C, D, 0 E, F, G, T4; ATEX II 1/2 GD EEx d [ia] IIC T6 to T4 T100 C 4) Enclosure (see also option A01) Aluminum epoxy coated 2 x ½" NPT via adapter - cable inlet, IP6 0 2 x M20x1. cable inlet, IP6 1 2 x ½" NPT via adapter - cable inlet, IP68 2 2 x M20x1. cable inlet, IP68 3 Additional options Standard version (PPS Probe body) A With thermal isolator (PPS Probe body) B With PVDF probe body C With thermal isolator and PVDF probe body D WHG approval, German overfill protection Not required A Required 3) B Electronics/output Standard version without display, 12 to 0 20 V AC/DC, solid-state and relay output 6) Digital version with display, 24 V DC, solid-state 1 output or PROFIBUS PA 6) 7) Further designs Order code Total insertion length: enter the total insertion length Y01 in plain text description Stainless steel tag [69 x 38 mm (2.7 x 1.")]: Measuring-point number/identification (max. 20 charac- Y1 ters); specify in plain text Electrical connection/cable inlet: PROFIBUS PA A01 4) 8) 9) connector M12 Optional enclosure lid: Lid with glass window A04 instead of closed lid without window 6) Acceptance test certificate: Manufacturer's test C11 certificate M to DIN 30, Part 18 and ISO 9000 Inspection Certificate Type 3.1 per EN 10204 C12 SIL/IEC6108 Declaration of Conformity [SIL-2 C20 (overspill)] 3) Remote Electronics Remote mounted electronics with 2 m (79") cable A0 Remote mounted electronics with m (197") cable Mounting bracket (including mounting kit) for remote electronics A06 A09 /22 Siemens FI 01 2009

Level instruments, welded flange, PFA coated C) 7 M L 0 - Versatile inverse frequency shift capacitance level 7 7 7 77-77 7 7 slurries, foam and interfaces. Instruction manual See page /23 Note: The instruction manual should be ordered as a separate line on the order. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. Accessories See page /23 1) No Y01 needed in order code 2) Custom shipping methods required. Contact factory for more details. 3) Available with electronics option 0 only 4) Available with electronics option 1 only ) Barrier required for Intrinsically Safe protection 6) Version with electronics option 0 has a standard closed lid without window as default; version with electronics option 1 has a standard lid with glass window as default. 7) An M12 PROFIBUS PA connector can be selected separately with wildcard option (A01). 8) Available only with enclosure option 1 9) Available with approval option 1, 7, and 8 only C) Subject to export regulations AL: N, ECCN: EAR99 Instruction manual English 7ML1998-AR02 French 7ML1998-AR12 German 7ML1998-AR32 Note: The instruction manual should be ordered as a separate line on the order. Additional instruction manual Quick Start manual, multi-language 7ML1998-QE81 Note: Due to ATEX regulations, one Quick Start manual is included with every product. This device is shipped with the Siemens Milltronics manual CD containing the complete ATEX Quick Start and instruction manual library. Accessories Sensguard, ¾" NPT (PPS) 7ML1830-1DL Only available for CLS200 with ¾" NPT thread Sensguard, R 1" (BSPT) (PPS) 7ML1830-1DM Only available for CLS200 with ¾" NPT thread ½" NPT cable gland, nickel plated brass, fits cable 7ML1830-1JA diameter 6 to 12 mm (0.24 to 0.47") -40 to +100 C (-40 to +212 F), IP68 (General Purpose) ½" NPT cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JB and EEx e II, fits cable diameter 6. to 14 mm (0.26 to 0."), -60 to +130 C (-76 to +266 F), IP68 (Explosion Proof) M20x1. cable gland, PA polyamide, ATEX II 2G 7ML1830-1JC EEx e II, fits cable diameter 7 to 12 mm (0.28 to 0.47"), -20 to +70 C (-4 to +18 F), IP68 (General Purpose) M20x1. cable gland, brass, ATEX II 2GD EEx d IIC F) 7ML1830-1JD and EEx e II, fits cable diameter 10. to 1.9 mm (0.41 to 0.63"), under armour cable diameter 6.1 to 11. mm (0.24 to 0.4"), -60 to +130 C (-76 to +266 F), IP68 (Explosion Proof) One metallic cable gland M20x1., -40 to +80 C 7ML1930-1AP (-40 to +176 F) One metallic cable gland M20x1., -40 to +80 C 7ML1930-1AQ (-40 to +176 F) with integrated shield connection (available for PROFIBUS PA) Blind threaded flanges are available. Please contact nacc.smpi@siemens.com with a completed application data sheet on page /8 Spare parts Test magnet (digital version) 7ML1830-1JE Amplifier/power supply, standard version C) 7ML1830-1DJ Amplifier/power supply, digital version 7ML1830-1JF LCD display (digital version) 7ML1830-1JK C) Subject to export regulations AL: N, ECCN: EAR99 F) Subject to export regulations AL: 9I999, ECCN: N Options Optional Sensguard dimensions Siemens FI 01 2009 /23

Level instruments Characteristic curves P Example: Permitted operating pressure = 10 bar (14 psi) at 7 C T Pressure/Temperature Curve CLS200 Sliding Coupling Threaded Process Connections (7ML02) P = Permitted Operating Pressures T = Permitted Operating Temperature Process Pressure/Temperature derating curves (7ML02) Process Pressure/Temperature derating curves (7ML02) /24 Siemens FI 01 2009

Level instruments Process Pressure/Temperature derating curves (7ML02) Process Pressure/Temperature derating curves (7ML02) Siemens FI 01 2009 /2

Level instruments Process Pressure/Temperature derating curves (7ML04) Process Pressure/Temperature derating curves (7ML04 and 7ML0) /26 Siemens FI 01 2009

Level instruments Process Pressure/Temperature derating curves (7ML04) Process Pressure/Temperature derating curves (7ML04 and 7ML0) Siemens FI 01 2009 /27

Level instruments Dimensional drawings dimensions - Threaded/Sanitary Process Connections /28 Siemens FI 01 2009

Level instruments dimensions - Flanged Process Connections Siemens FI 01 2009 /29

Level instruments Schematics connections /30 Siemens FI 01 2009