Anybus X-gateway. PROFIBUS Master Interface NETWORK GUIDE SCM EN 1.0 ENGLISH

Similar documents
Anybus Communicator PROFINET

Anybus X-gateway EtherNet/IP

Anybus X-gateway. PROFINET IRT (2.32) Interface NETWORK GUIDE

Anybus.NET. using TIA Portal with PROFIBUS APPLICATION NOTE

FIP IO Slave. X-gateway Interface Addendum. Doc: HMSI Rev: Connecting DevicesTM

PROFIBUS Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

REFERENCE GUIDE HMSI ENGLISH

Anybus CompactCom Starter Kit REFERENCE GUIDE

Anybus Communicator STARTUP GUIDE. IIoT. SP en-us ENGLISH

STARTUP GUIDE. SP en-us ENGLISH

X-gateway Interface Addendum CC-Link Slave Interface

Enabling and Using OPC UA on Anybus CompactCom 40

Anybus.NET Bridge PROFIBUS

CANopen Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

USB RS232 Cable Converter

How to Configure DeviceNet with Anybus Configuration Manager (ACM) for DeviceNet APPLICATION NOTE DRAFT

EtherCAT Slave. X-gateway Interface Addendum. Doc: HMSI , Rev: Connecting Devices TM

Netbiter EC300 Series

Anybus X-gateway USER MANUAL

NT 200/420. Communication in Gateway Setup SOFTWARE DESIGN GUIDE ENGLISH

USB-to-CAN V2. Compact Embedded Automotive Professional USER MANUAL ENGLISH

INSTALLATION GUIDE en-us ENGLISH

FR-IB100/PCIe. FlexRay PCI Express Interface Card USER MANUAL ENGLISH

ControlNet Adapter. X-gateway Interface Addendum. Doc: HMSI Rev: Connecting Devices TM

USER MANUAL en-us ENGLISH

NTP Client Server Relay

KPI Configuration APPLICATION NOTE KB EN 1.0

CANbridge NT. 200 and 420 USER MANUAL EN 1.3

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO USER MANUAL ENGLISH

SOLUTION SHEET. KB en-us

Anybus Wireless Bolt RJ45 PoE

APPLICATION NOTE SCM ENGLISH

Anybus CompactCom 40 Diagnostic Events for PROFIBUS APPLICATION NOTE

Anybus Wireless Bridge II

Anybus Communicator CAN

USB-to-CAN FD. Compact Embedded Automotive USER MANUAL ENGLISH

Anybus CompactCom 40 Diagnostic Events for Modbus-TCP APPLICATION NOTE

AnyBus -X Modbus Plus Slave

Anybus CompactCom 40 Diagnostic Events for EtherNet/IP

STARTUP GUIDE SCM /SP ENGLISH

Anybus CompactCom 40 Diagnostic Events for EtherCAT SCM ENGLISH

X-gateway Interface Addendum DeviceNet Scanner

Anybus CompactCom Option Board Freescale

Network Certification Policies and Instructions HMSI ENGLISH

INpact Slave PCIe. Profibus/PROFINET IRT Fiber Optic/CC-Link/DeviceNet USER MANUAL EN 1.5

NT. 200 and 420 USER MANUAL EN 1.4

Anybus Wireless Bridge

ControlNet Adapter Interface

Network Interface Appendix Anybus -CompactCom Passive RS-485/422

Anybus WLAN Access Point IP67 USER MANUAL

WAN Connection Fallback

X-gateway Interface Addendum DeviceNet Scanner Interface

The Cosy 131 User Guide USER MANUAL

Anybus CompactCom 40 PROFIBUS DP-V0/DP-V1 NETWORK GUIDE

SOFTWARE DESIGN GUIDE AUG ENGLISH

User Manual Anybus Serial Server

Overview. 08/06/2012 Page 2/47

Anybus CompactCom. Host Application Implementation Guide HMSI ENGLISH

FLB G (Verizon) Extension Card INSTALLATION GUIDE

Anybus Wireless Bolt RJ45 PoE USER MANUAL

Fieldbus Appendix AnyBus-S FIPIO

User Manual Anybus Communicator CAN Modbus RTU

SBPC-21-PB FifeNet to Profibus Gateway

User Manual Anybus Modbus TCP/RTU Gateway

Netbiter EasyConnect

Anybus X-gateway Modbus-TCP PROFINET

Anybus-S CC-Link. Fieldbus Appendix. Rev HMS Industrial Networks AB. Germany Japan Sweden U.S.A UK

Anybus X-gateway Modbus-TCP PROFINET

User Manual Anybus Communicator for CC-Link IE Field

Fieldbus Appendix Anybus-S Interbus 2Mbit/s Fibre Optic

CAN-Gateway Configurator

Anybus X-gateway Modbus-TCP Modbus-TCP

EL731 PROFIBUS INTERFACE

INpact Slave PCIe. Industrial Ethernet PCIexpress Interface USER MANUAL ENGLISH

Easy Commissioning via SD Card & USB Drive

Network Interface Appendix Anybus -S CC-Link IE Field Network

User Guide AnyBus NetTool for DeviceNet

AnyBus-PCI Profibus DPV1 Master

Anybus Wireless Bridge II USER MANUAL

FRC-EP170. Automotive Platform USER MANUAL en-us ENGLISH

Anybus X-gateway LonWorks Interface

Anybus X-gateway Modbus-TCP Modbus-TCP

Anybus X-gateway Modbus-TCP EtherNet/IP

FieldServer FS PROFIBUS DP Master

RMx621. Appendix to the operating manual

RMx621 /FML621. Appendix to the operating manual

Network Certification

Anybus Wireless Bolt USER MANUAL

Anybus CompactCom 30 SOFTWARE DESIGN GUIDE

SG Gateway USER MANUAL ENGLISH

PROFIBUS Adapter. 20-COMM-P FRN 1.xxx. User Manual

PROFIBUS DP/CAN Gateway PCA-100. User Manual

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

BridgeWay. PROFIBUS to DeviceNet Gateway User Manual. Part No. AB7605. Publication PUB-AB

Network Interface Appendix Anybus CompactCom PROFIBUS DP-V0

FC8x. Profibus Communication

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

Anybus X-gateway Modbus-TCP Modbus RTU

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

Gateway 1400 Reference Manual

Transcription:

Anybus X-gateway PROFIBUS Master Interface NETWORK GUIDE SCM-1202-104 EN 1.0 ENGLISH

Important User Information Liability Every care has been taken in the preparation of this document. Please inform HMS Industrial Networks AB of any inaccuracies or omissions. The data and illustrations found in this document are not binding. We, HMS Industrial Networks AB, reserve the right to modify our products in line with our policy of continuous product development. The information in this document is subject to change without notice and should not be considered as a commitment by HMS Industrial Networks AB. HMS Industrial Networks AB assumes no responsibility for any errors that may appear in this document. There are many applications of this product. Those responsible for the use of this device must ensure that all the necessary steps have been taken to verify that the applications meet all performance and safety requirements including any applicable laws, regulations, codes, and standards. HMS Industrial Networks AB will under no circumstances assume liability or responsibility for any problems that may arise as a result from the use of undocumented features, timing, or functional side effects found outside the documented scope of this product. The effects caused by any direct or indirect use of such aspects of the product are undefined, and may include e.g. compatibility issues and stability issues. The examples and illustrations in this document are included solely for illustrative purposes. Because of the many variables and requirements associated with any particular implementation, HMS Industrial Networks AB cannot assume responsibility for actual use based on these examples and illustrations. Intellectual Property Rights HMS Industrial Networks AB has intellectual property rights relating to technology embodied in the product described in this document. These intellectual property rights may include patents and pending patent applications in the USA and other countries. Anybus is a registered trademark of HMS Industrial Networks AB. All other trademarks mentioned in this document are the property of their respective holders.

Table of Contents Page 1 Preface... 3 1.1 About This Document...3 1.2 Document history...3 1.3 Document Conventions...4 1.4 Document-specific Conventions...4 2 Description... 5 2.1 Overview...5 3 Installation... 6 3.1 Connectors and Switches...6 3.2 LED Indicators...7 3.3 Installation Overview...8 4 Configuration... 9 4.1 Anybus Configuration Manager...9 4.2 Network Configuration Example...10 5 Technical Data... 12 5.1 Technical Specifications...12

This page intentionally left blank

Preface 3 (14) 1 Preface 1.1 About This Document This document describes how to configure and use the Anybus X-gateway PROFIBUS Master Interface. For additional documentation and software downloads, FAQs, troubleshooting guides and technical support, please visit www.anybus.com/support. 1.2 Document history Version Date Description 1.0 2018-08-17 New document replacing HMSI-27-250

Preface 4 (14) 1.3 Document Conventions Ordered lists are used for instructions that must be carried out in sequence: 1. First do this 2. Then do this Unordered (bulleted) lists are used for: Itemized information Instructions that can be carried out in any order...and for action-result type instructions: This action... leads to this result Bold typeface indicates interactive parts such as connectors and switches on the hardware, or menus and buttons in a graphical user interface. Monospaced text is used to indicate program code and other kinds of data input/output such as configuration scripts. This is a cross-reference within this document: Document Conventions, p. 4 This is an external link (URL): www.hms-networks.com This is additional information which may facilitate installation and/or operation. This instruction must be followed to avoid a risk of reduced functionality and/or damage to the equipment, or to avoid a network security risk. Caution This instruction must be followed to avoid a risk of personal injury. WARNING This instruction must be followed to avoid a risk of death or serious injury. 1.4 Document-specific Conventions The following conventions are used specifically in this document: Hexadecimal values are written as NNNNh (the suffix h indicates hexadecimal notation). 16 and 32 bit values are stored in Motorola (big endian) format unless otherwise stated.

Description 5 (14) 2 Description 2.1 Overview The Anybus X-gateway PROFIBUS Master Interface has complete PROFIBUS DP Master functionality according to IEC 61158. The PROFIBUS master interface allows up to 125 PROFIBUS slaves to exchange data with another network. The interface exchanges data via two memory buffers: Input Buffer Output Buffer Contains data coming from the PROFIBUS slaves. Contains data going to the PROFIBUS slaves. Fig. 1 Data flow The PROFIBUS master interface can exchange up to 512 bytes of I/O data in each direction. The actual byte sizes of input and output data are set in the network configuration created with a PROFIBUS network configuration tool such as Anybus NetTool for PROFIBUS. The output data area can optionally include general status information from the PROFIBUS network. See the Anybus X-gateway User Manual for more information.

Installation 6 (14) 3 Installation 3.1 Connectors and Switches This product contains parts that can be damaged by electrostatic discharge (ESD). Use ESD prevention measures to avoid damage. Fig. 2 PROFIBUS master adapter interface PROFIBUS Connector X1.1 (female 9-pin D-sub) If the node is the last on a bus segment, use a PROFIBUS connector with built-in terminating resistors. Pin Signal Description 1 - (reserved) 2 - (reserved) 3 Line B Positive RS-485 RxD/TxD 4 RTS Request To Send 5 GND BUS Isolated signal ground (RS-485) 6 +5V BUS +5 V (RS-485) 7 - (reserved) 8 Line A Negative RS-485 RxD/TxD 9 - (reserved) Housing Shield Connected to PE PROFIBUS Configuration Connector X1.2 (male 9-pin D-sub) The PROFIBUS configuration connector is used to connect a computer to the master interface for configuration. A null modem cable with female 9-pin D-sub connectors is required. Pin Signal Description 1 - (reserved) 2 RS-232 Rx RS-232 receive data 3 RS-232 Tx RS-232 transmit data 4 - (reserved) 5 GND Signal Ground 6 DSR (reserved) 7 - (reserved) 8 - (reserved) 9 - (reserved) Housing Shield Connected to PE

Installation 7 (14) 3.2 LED Indicators Fig. 3 PROFIBUS master interface LED indicators The GW Status LED indicates the status of the X-gateway. The other LEDs indicate network communication and interface status. LED Indication Meaning Off No power GW Status Green Gateway running Red Communication error Red, flashing Network interface error Off Offline Green Operating mode MS Green, flashing Clear mode Red Stop mode Off No database downloaded DB Green Database OK Green, flashing Database download in process Red Database invalid Off No data exchange COM Green Data exchange with all configured slaves Green, flashing Data exchange with at least one slave Red Bus control error TOK Off Master does not hold the token Green Master holds the token

Installation 8 (14) 3.3 Installation Overview Prerequisites The following items are required for installation: USB cable PROFIBUS cable Null modem cable PROFIBUS network configuration tool GSD files for the slaves on the PROFIBUS network The free Windows-based PROFIBUS network configuration tool Anybus NetTool for PROFIBUS can be downloaded from www.anybus.com/support. Basic installation steps Some steps are optional depending on your actual installation and method of configuration. 1. Connect the PROFIBUS master interface to the network. 2. Connect a computer to the USB connector. 3. Connect a computer to the PROFIBUS configuration connector using a null modem cable. 4. Power on the gateway. 5. Install the GSD file in the PROFIBUS network configuration tool and configure the PROFIBUS network. 6. Configure the data exchange options for the PROFIBUS master interface and the other network interface in Anybus Configuration Manager.

Configuration 9 (14) 4 Configuration 4.1 Anybus Configuration Manager The data exchange between the interfaces in the Anybus X-gateway is configured using the Windows-based configuration tool Anybus Configuration Manager, which can be downloaded from www.anybus.com/support. Fig. 4 Anybus Configuration Manager General Settings Offline option Control word/status word The action to perform if the network goes offline. The gateway can either freeze (keep the current value) or clear (set to zero) the data from the offline network. Enables/disables representation of the Control/Status word. Fieldbus Specific Settings Live list Network Configurator Enables/disables the Live List. If Anybus NetTool for PROFIBUS is installed it can be launched by clicking here.

Configuration 10 (14) 4.2 Network Configuration Example In this example a simple PROFIBUS network has been created using the free Windows-based network configuration tool Anybus NetTool for PROFIBUS. The network consists of 3 slaves and an Anybus X-gateway PROFIBUS Master Interface acting as master. Fig. 5 Example network in Anybus NetTool for PROFIBUS Node Slot Input data size Output data size 0 (master) 1 128 bytes 128 bytes 3 2 32 bytes 4 1 32 bytes 1 32 bytes 5 2 64 bytes The slave I/O addresses overview window in NetTool shows the resulting slave I/O map: Fig. 6 Slave address overview in Anybus NetTool Node Input address range Output address range 3 0... 127 0... 127 128... 159 4-160... 191 5 128... 159 192... 255 Note that the actual input/output addresses defined in the I/O map are the ones that will be used on the other end.

Configuration 11 (14) The slave I/O map is also reflected in the input and output data exchange buffers of the PROFIBUS master interface: Slave Input Data Slave Output Data Anybus NetTool for PROFIBUS can be downloaded from www.anybus.com/support, where you will also find additional documentation and configuration examples.

Technical Data 12 (14) 5 Technical Data 5.1 Technical Specifications PROFIBUS functionality Complete Profibus DP Master functionality according to IEC 61158 Optional Live List of the active status of the connected slaves Maximum number of slaves 125 Maximum I/O data 512 bytes in each direction Supported baud rates Automatic baudrate detection up to 12 Mbit/s Configuration method Anybus Configuration Manager via serial port (RS-232) PROFIBUS connector 1 x D-sub 9-pin female Configuration port 1 x D-sub 9-pin male

This page intentionally left blank

last page 2018 HMS Industrial Networks Box 4126 300 04 Halmstad, Sweden info@hms.se SCM-1202-104 EN 1.0 / 2018-08-17 / 9122