Table of Contents. Introduction Installation Pin Assignments Method of Programming Setup Commands... 9

Similar documents
CCD-BARCODE SCANNER. Programming Manual. To program the device, scan the following codes: FIRST: start configuration %$ + / 0

1.1 Notice Introduction Codes Read Installation Pin Assignment Specification... 8

GS100. CCD Barcode Scanner. User Manual

BAR CODE. SYMBOLOGY PROGRAMMING for POCKET SCANNERS

Programming Menu V4.2

Programming Menu V3.91

Area Imager Bar Code Scanner 2 D C O N F I G U R A T I O N G U I D E

COPYRIGHT 2009,SCSC. Manual P/No: SCCM - 80S-01A Released Date: Oct 31, 2009

BARCODE SCANNER. Configuration Guide - 1 -

NC-1200 BARCODE SCANNER. Configuration Guide - 1 -

Table of Contents Sleep Settings How to Configure the Scanner. 7 Chapter 2 System Setup

Setup Procedures 2 Batch Setup 3. Bar Code Setup Menu 5. 1 Device Selection and Default. 2 Beep and Delay Keyboard Wedge..

PureScan - ML1. Configuration Guide. Wireless Linear Imager Wireless Laser scanner - 1 -

Xi2000-BT Series Configuration Guide

Manuel de programmation du lecteur LDT75C ver 2.1

User s Manual. Xi3000 Scanner. Table of Contents

CCD - 75 USB. Programming Manual. GOMARO s.a. - Z.I. La Rosaire 5 - CH Aclens

Introduction FCC Statement

Getting Started Setup Procedures

SPEECHMIKE TM PHI BARCODE READER PROGRAMMING MANUAL PRO READER

Laser Barcode Scanner ARP Nr User s Manual

Configuration Manual PULSAR C CCD SCANNER. Table of Contents

marson MT8200S 2D Handheld Scanner User Manual V / 6 / 25 - I -

Barcode reader setup manual

ZBX P/N : MUL LASER LIGHT CAUTION DO NOT STARE INTO BEAM

Specification or version may be subject to change without notice. The actual specification and version are based on the product delivered.

Start Configuration. Chap.1 System Information. Set All default

2D Barcode Reader User Guide V 1.2.1

FD-011WU. 2D Barcode Reader User Guide V1.6CC

NT-1200 CCD Wired Barcode Scanner Overview

Manual de Programación

Installation- Keyboard Wedge

If you want to do other configurations please refer to below programming barcodes.

MK D Imager Barcode Scanner Configuration Guide

User s Guide. Linear Imager

2D BARCODE SCANNER CA-SC-20200B

User s Manual 131 Tiny III Decoder

Wired Laser Barcode Scanner User Manual V:1509

广州虹源电子有限公司. Guangzhou Hong yuan Electronic co.,ltd. Configuration Manual

Hand Held Linear Imager

C O N F I G U R A T I O N G U I D E

DLL2020. Software Configuration Manual

ZB-8150/ZB-8110/ZB-8210 CCD BARCODE SCANNER. User s Manual. ZBA Inc 249 Homestead Rd Unit 12 Hillsborough NJ 08844

MD5 Series Barcode Scanner

C O N F I G U R A T I O N G U I D E

User's Manual CIPHER 1022 SERIES

MD22xx Barcode Scanner

1. Factory Default Se ng (include below three steps)

SPECIFICATION. Customer : Customer s Model No. : Model No. : SG600 Gun-type Linear Imager Bar Code Scanner Series. Date: Sample Serial No.

MD22xx Barcode Scanner

Table of contents. Change scanner settings Factory default settings Default message format Programming flow chart

XB-8200 Hand Free Area Image Scanner Configuration Guide

BARCODE READER MDS-160

Introduction. Installation- Keyboard Wedge

MP80xx Image Platform

Omni-Directional Barcode Scanner Model No. OM7120

Wireless 2D Pocket barcode scanner

IPDA014-2D. Embedded 2D Barcode Scan Engine. User Guide

Flow chart of bar code reader setting

Nuscan 3200 Optical Laser Barcode Scanner

ValueScan II TM Barcode Scanner. User s Manual rev.a

BARCODE SCANNER. FUZZYSCAN FAMILY Quick Start Guide

Advanced Handheld High-Speed Laser Scanner

BD-6500BT Bluetooth 2D Barcode Scanner Configuration Guide

Preliminary draft_1. Prefix Scanned Data Suffix. Intercharacter Delay. Intercharacter Delay

Programming with barcodes

Menu & commands booklet FOR BAR CODE SCANNERS * *

WLR 8900/8905 Programming Guide

User s Manual. Addendum to. Ranger Wedge Interface. Part No. 25-WEDGE-06A Ver. April 1999

000A1 Display inward character string(custom) USB-HID Single not triggered Not:CCD inapplicability Continuous Scan Mode

User s Manual. MS140-3 or MS140I-3 Keyboard Wedge Slot Reader. PC Keyboard Wedge Setup Label

Programming. User s Manual. Ver:3.2. Contents - 1 -

NOTICE: respective owner. Note: Specification is subject to changes without. notice.

Product Engineering Specification Scan Utility

Area Imager Bar Code Scanner 2 D C O N F I G U R A T I O N G U I D E

MD65xx Image Barcode Scanner

Advanced Miniature CCD Scan Module 1

AS-8050 CCD Scanner User Guide

Configuration Commands

Datalogic Scanning, Inc. 959 Terry Street Eugene, Oregon Telephone: (541) Fax: (541)

MP720 Presentation Imager

C O N F I G U R A T I O N G U I D E

Programming User s Manual

SD380 Linear Imager Bar Code Scanner SPECIFICATION. Model No. : SD380 Linear Imager Bar Code Scanner. Spec. Version & Revision Date: V

2D barcode scanner User Manual

SPECIFICATION. Customer : Customer s Model No. : Model No. : MCR14 CCD Bar Code Scanning Module. Date: Sample Serial No. :

El5220. Image Platform. User Manual

Hand Held Scanner. User s Manual

Wireless 2D Pocket barcode scanner

Manual POSline SC2120/SC2130/SC2140 1D & 2D Barcode Reader User's

Delivery content * Pocket Barcode scanner x 1 * Mini USB cable x 1 (for charging only) * Quick instructions x 1 * Strap x 1

MP168 Screen Barcode Image Platform

Wearable 2D Pocket barcode scanner

MD60xx Image Barcode Scanner

User s Manual WARNING CIPHER 1000 CCD SERIES

DelfiScan C70. Programming Manual

ADDMASTER. Addmaster Corporation. IJ-3080 Journal/Validation Printer. Specification. IJ-3080 Specification

FM100 Laser Barcode Scan Engine

Barcode Scanning Made Easy. Programming Guide

Delivery content * Pocket Barcode scanner x 1 * Mini USB cable x 1 (for charging only) * Quick instructions x 1 * Strap x 1

Transcription:

Table of Contents Introduction... 3 Installation... 4 Pin Assignments... 5 Method of Programming... 7 Setup Commands... 9 Interface selection... 10 Reading Mode... 11 RS 232 Communication Parameters... 12 Keyboard Wedge Parameters... 14 Output Characters Parameters... 16 Wand Emulation... 18 Bar Code Type Selection... 19 UPC/EAN/JAN... 23 Code 39... 26 Code 128... 28 Interleave 25... 30 Industrial 25... 32 Code 2 of 6... 34 Matrix 25... 36 CODABAR/NW7... 38 Code 93... 40 Code 11... 42 MSI/PLESSEY... 44 LCD 25... 46 Telepen... 48 GS1 Databar (RSS Code )...50 1

Table of Contents Language Selection... 52 Bar Code ID... 54 Accuracy... 57 Sensitivity of Continuous Reading Mode... 57 Same Code Delay Reading Interval... 57 Buzzer Beep Tone... 58 PnP/Notebooks... 58 Reverse Output Characters... 58 LED Control... 58 Setup Deletion... 59 Setup Insertion... 63 Setup IR Sensor... 67 Appendix A - Decimal Value... 68 Appendix B - ASCII Table... 69 Appendix C - Function Key Table... 73 2

Introduction Thank you for selecting Birch barcode input product. The reader is equipped with up to date optical technology. It auto-discriminates the different kinds of barcode symbologies. Birch also provides other barcode related products to meet your application. The easily plug and play design of the keyboard wedge interface, provides a flexible solution to your application to explore the magic of the barcode system. This manual provides an easily method to modify the decoding options and interface protocols by scanning the barcode in the manual. Before starting, please make sure that the barcode reader is properly powered. For PC keyboard emulation type interface, power is directly come from the system. For RS-232 or other non-pc keyboard emulation type interface, an external power is always needed. Codes Read ALL UPC/EAN/JAN, Code 39, Code 39 Full ASCII, Code 128, Interleave 25, Industrial 25, Matrix 25, Code 26, CODABAR/NW7, Code 11,MSI/PLESSEY, Code 93, China Postage, LCD25,Telepen, GS1 Databar( RSS-14,RSS Limited, RSS Expanded). LEGISLATION AND WEEE SYMBOL This marking shown on the product or its literature, indicates that it should not be disposed with other households wastes at the end of its working life. To prevent possible harm to the environment or human health from uncontrolled waste disposal, please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources. Household users should contact either the retailer where they purchased this product, or their local goverment office, for details of where and how they can take this item for environmentally safe recycling. Business users should contact their supplier and check the terms and conditions of the purchase. 3

Installation Installing the Keyboard Wedge Reader To install a keyboard wedge reader, follow the steps below: 1. Turn off the power of the PC or Terminal. 2. Unplug keyboard from the PC or Terminal. 3. Make sure you have the Y Cable with appropriate connector type for your PC or Terminal. 4. Connect Scanner to your PC or Terminal 5. Connect the keyboard connector to the female connector of the Y cable 6. Turn on the power of PC or Terminal. If the installation is successful, the Green LED light on the top of the reader should light up, and you should hear three beeps from reader. Installing the RS232 Reader To install a RS232 reader, follow the steps below : 1. Turn off the power of the PC or Terminal. 2. Make sure the connector type from RS232 to the PC or Terminal is correct. 3. Plug AC Adaptor connector into connector of the reader. 4. Turn on the power of PC or Terminal. 5. Setup the Interface of the reader to RS232 mode by scanning the barcode in the Interface Selection section. If the installation is successful, the Green LED light on the top of the reader should light up, and you should hear three beeps from reader. 4

1. Keyboard Output Pin Assignments DIN 5 MALE DIN 5 FEMALE Pin No. Function Pin No. Function 1 HOST CLK 1 KB CLK 2 HOST DATA 2 KB DATA 4 GND 4 GND 5 Vcc(+5V) 5 Vcc(+5V) 1 3 4 5 2 DIN 5 Male Pin Assignment 3 1 5 4 2 DIN 5 Female Pin Assignment MiniDIN 6 MALE MiniDIN 6 FEMALE Pin No. Function Pin No. Function 1 HOST DATA 1 KB DATA 3 GND 3 GND 4 Vcc 4 Vcc 5 HOST CLK 5 KB CLK 5 3 6 4 6 4 5 3 1 2 2 1 MiniDIN 6 Male Pin Assignment MiniDIN 6 Female Pin Assignment 5

Pin Assignments 2. RS-232 Output DB 9 Female Pin No. Function 2 TXD 3 RXD 5 GND 7 CTS 8 RTS Power Lead Vcc +5V 5 1 9 6 +5V GND DB 9 Female Pin Assignment Male DC Jack 3. WAND Emulation Output DB 9 Female Pin No. Function 2 DATA 7 GND 9 Vcc (+5V) 5 1 9 6 DB 9 Female Pin Assignment 6

Setup Flow Chart Method of Programming Start Configuration Recall Parameters Set All Defaults Interface Selection Input Port Selection Communication Parameters Bar Codes Parameters MSR Parameters Misc. Parameters etc. Abort Configuration End Configuration Save Parameters Loop of Programming The philosophy of programming parameters has been shown on the flow chart. Basically user should 1. Scan Start of Configuration. 2. Scan all necessary labels for parameters that meet applications. 3. Scan End of Configuration to end the programming. 4. To permanently save the settings you programmed, just scan label for Save Parameters. 5. To go back to the Default Settings, just scan label for Set All Defaults. 7

Method of Programming Factory Default Settings The factory default settings are shown with < > and bold in the following sections. You can make your own settings by following the procedures in this manual. If you want to save the settings permanently, you should scan the label of "Save Parameters" on page 9, otherwise the settings will not be saved after the decoder power is off, and all settings will go back to previous settings. By scanning "Set All Default" label, the settings will go back to the factory default settings. 8

Setup Commands Save Parameters Save the parameter settings permanently. %$ + / 0 Recall Stored Parameters Replace the current parameters by which you had saved last time. %$ + / 1 Set All Defaults Set all the parameters to the factory default settings. %$ + / 2 Start Configuration %$ + / 3 End Configuration %$ + / 4 Abort Configuration Terminate current programming status. %$ + / 6 Version Information Display the decoder version information and date code. %$ + / 5 9

Start Configuration Interface Selection Interface %0 0 U0 <Keyboard> %0 0 U8 RS232 Mode %0 0 M2 WAND Emulation %0 X O8 USB Mode 10

Reading Mode End Configuration Reading Mode <Good Read OFF> %0271 Trigger ON/OFF %0270 Continuous/Trigger OFF %0272 Continuous/Auto Power ON %0273 Flash %0274 Flash/Auto Power ON %0276 Testing %0275 Reserved1 %0277 11 Save Configuration

RS-232 Communication Start Configuration RS-232 Communication Parameters Set Up BAUD Rate 1200 %0 Y 7 1 %0 Y 7 2 2400 %0 Y 7 3 4800 <9600> %0 Y 7 7 %0 Y 7 4 19200 Set Up Data Bits %0 Y 8 0 7 Data Bits <8 Data Bits> %0 Y 8 8 Set Up Stop Bits %0 Y O8 <1 Bit> %0 Y O0 2 Bits 12

RS-232 Communication End Configuration RS-232 Communication Parameters Set Up Parity <None> Even Odd Mark Space %0 Y N7 %0 Y N2 %0 Y N3 %0 Y N1 %0 Y N0 Handshaking RTS/CTS Enable <RTS/CTS Disable> ACK/NAK Enable <ACK/NAK Disable> XON/XOFF Enable <XON/XOFF Disable> %0188 %0180 %0144 %0140 %0 3 K 4 %0 3 K 0 13 Save Configuration

Keyboard Wedge Start Configuration Keyboard Wedge Parameters Terminal Type <IBM PC/AT, PS/2> %0ZF0 %0ZF1 %0ZF2 %0ZF3 %0ZF4 %0ZF5 %0ZF6 %0ZF7 %0ZF8 %0ZF9 %0ZFA %0ZFB %0ZFC %0ZFD IBM PC/XT IBM PS/2 25, 30 NEC 9800 ADB IBM 5550 IBM 122 Key (1) IBM 102 Key IBM 122 Key (2) Reserved 1 Reserved 2 Reserved 3 Reserved 4 Reserved 5 14

Keyboard Wedge End Configuration Keyboard Wedge Parameters Upper/Lower Case <No Change> %0330 Upper Case %0331 Lower Case %0332 Send Character by ALT Method Enable %0 3 O8 <Disable> Select Numerical Pad ON %0 3 O0 %0 1 K 4 <OFF> %0 1 K 0 Capslock Detection Enable %0 X8 8 <Disable> %0 X8 0 Save Configuration 15

Output Parameters Start Configuration Output Characters Parameters Select Terminator %7 S 2 + <CR+LF> %7 S 7 + None %7 S 0 + CR %7 S 1 + LF %7 S 4 + Space HT(TAB) %7 S 3 + %7 S 5 + STX-ETX 16

Output Parameters End Configuration Output Characters Parameters Time-out Between Characters <0 ms> %0070 5 ms %0071 10 ms %0072 25 ms %0073 50 ms %0074 100 ms %0075 200 ms %0076 300 ms %0077 Save Configuration 17

Wand Emulation Start Configuration Wand Emulation TTL Level Representation <Bar Equals High> %0 2 K 4 %0 2 K 0 Bar Equals Low Scan Speed Selection %0288 <Fast> %0280 Slow Output Format Selection %0 2 O8 <Output as Code 39> %0 2 O0 Output as Code 39 Full ASCII %0XK4 Output as Original Code Format 18

Symbology Bar Code Type Selection End Configuration UPC-A <ON> %0 A 4 4 OFF %0 A 4 0 UPC-E <ON> %0 B O8 OFF %0 B O0 EAN-13/JAN-13/ ISBN 13 <ON> %0 A 2 2 OFF %0 A 2 0 EAN-8/JAN-8 <ON> %0 A 1 1 OFF %0 A 1 0 CODE 39 <ON> %0 E O8 OFF %0 E O0 Save Configuration 19

Symbology Start Configuration Bar Code Type Selection CODE 128 %0 F O8 <ON> OFF %0 F O0 CODABAR/NW7 %0 J O8 <ON> OFF %0 J O0 Interleave 25 %0 GO8 <ON> OFF %0 GO0 Industrial 25 %0 HO8 ON <OFF> %0 HO0 Code 2 of 6 %0 PO8 ON <OFF> %0 PO0 20

Symbology End Configuration Bar Code Type Selection Matrix 25 ON %0 I O8 <OFF> %0 I O0 CODE 93 ON %0 K O8 <OFF> %0 K O0 CODE 11 ON %0 L O8 <OFF> %0 L O0 China Postage ON %0 MO8 <OFF> %0 MO0 MSI/PLESSEY ON %0 NO8 <OFF> %0 NO0 Save Configuration 21

Symbology Start Configuration Bar Code Type Selection Telepen %0 T O8 ON <OFF> LCD25 %0 T O0 %0 QO8 ON <OFF> RSS-14 %0 QO0 %0 UO8 %0 UO0 ON <OFF> RSS Limited %0 VO8 %0 VO0 ON <OFF> RSS Expanded %0 WO8 ON <OFF> %0 WO0 %1 A / + Select All Bar Codes 22

Symbology End Configuration UPC/EAN/JAN Reading Type UPCA=EAN13 ON %0AK4 UPCA=EAN13<OFF> %0AK0 ISBN-10 Enable %0 B 8 8 ISBN-13 <Enable> %0 B 8 0 ISSN Enable %0 B 4 4 ISSN <Disable> %0 B 4 0 Decode with Supplementals %0 1 O0 <Autodiscriminate Supplementals> %0 1 O8 Save Configuration 23

Symbology Start Configuration UPC/EAN/JAN Supplementals Set Up <Not Transmit> %0 B 3 3 %0 B 3 1 Transmit 2 Code %0 B 3 2 Transmit 5 Code %0 B 3 0 Transmit 2&5 Code Expand UPC-E Enable %0 BH1 %0 BH0 <Disable> EAN8 = EAN13 Enable %0 AO8 %0 AO0 <Disable> GTIN Format Enable %0 X4 4 %0 X4 0 <Disable> 24

Symbology End Configuration UPC/EAN/JAN Check Digit Transmission UPC-A Check Digit Transmission <ON> %0 A I 2 OFF %0 A I 0 UPC-E Check Digit Transmission <ON> %0 B I 2 OFF %0 B I 0 EAN-8 Check Digit Transmission <ON> %0 A 8 8 OFF %0 A 8 0 EAN-13 Check Digit Transmission <ON> %0 A H1 OFF %0 A H0 ISSN Check Digit Transmission <ON> %0BK4 OFF %0BK0 Save Configuration 25

Start Configuration Code 39 Symbology Type of Code <Standard> %0 E H1 Full ASCII %0 E H0 %0 E 8 0 %0 E 8 8 Italian Pharmacy/Code 32<OFF> Italian Pharmacy/ Code 32 ON Check Digit Transmission %0 E M2 %0 E M6 %0 E M4 <Do Not Calculate Check Digit> Calculate Check Digit &Transmit Calculate Check Digit & Not Transmit Output Start/Stop Character Enable %0 E 4 4 %0 E 4 0 <Disable> Decode Asterisk Enable %0 E2 2 <Disable> %0 E2 0 26

Symbology Code 39 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 E 1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 E 0 0 1st Set Complete %4 E 0 1 2nd Set Begin (Then scan value in Appendix A) %4 E 0 0 2nd Set Complete %4 E 0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C0 + Save Configuration 27

Start Configuration Code 128 Symbology Check Digit Transmission %0 F N1 Do Not Calculate Check Digit %0 F N7 Calculate Check Digit & Transmit %0 F N5 <Calculate Check Digit & Not Transmit> Append FNC2 %0 F 8 8 ON <OFF> %0 F 8 0 UCC/EAN-128 Enable %0 F 4 4 <Disable> %0 F 4 0 28

Symbology Code 128 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label (s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 F 1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 F 0 0 1st Set Complete %4 F 0 1 2nd Set Begin (Then scan value in Appendix A) %4 F 0 0 2nd Set Complete %4 F 0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C1 + Save Configuration 29

Symbology Start Configuration Interleave 25 Check Digit Transmission %0 GN3 <Do Not Calculate Check Digit> %0 GN7 Calculate Check Digit & Transmit %0 GN5 Calculate Check Digit & Not Transmit Set Up Number of Character %0 G8 8 <Even> %0 G8 0 Odd Febraban Code %0 G4 4 Enable %0 G4 0 <Disable> 30

Symbology Interleave 25 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label (s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 G1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) 1st Set Complete %4 G0 0 %4 G0 1 2nd Set Begin (Then scan value in Appendix A) %4 G0 0 2nd Set Complete %4 G0 2 Minimum Length Begin(Then scan value in Appendix A) Complete %2 + - / %2 C2 + Save Configuration 31

Symbology Start Configuration Industrial 25 Check Digit Transmission %0 HN3 <Do Not Calculate Check Digit> %0 HN7 Calculate Check Digit & Transmit %0 HN5 Calculate Check Digit & Not Transmit IATA25 %0 H4 4 Enable <Disable> %0 H4 0 32

Symbology Industrial 25 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label (s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 H1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 H0 0 1st Set Complete %4 H0 1 2nd Set Begin (Then scan value in Appendix A) %4 H0 0 2nd Set Complete %4 H0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C3 + Save Configuration 33

Start Configuration Code 2 of 6 Check Digit Transmission %0 PN3 <Do Not Calculate Check Digit> %0 PN7 Calculate Check Digit & Transmit %0 PN5 Calculate Check Digit & Not Transmit 34

Code 2 of 6 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 P1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 P0 0 1st Set Complete %4 P0 1 2nd Set Begin (Then scan value in Appendix A) %4 P0 0 2nd Set Complete %4 P0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 CB+ Save Configuration 35

Start Configuration Matrix 25 Symbology Check Digit Transmission %0 I N3 <Do Not Calculate Check Digit> %0 I N7 Calculate Check Digit & Transmit %0 I N5 Calculate Check Digit & Not Transmit 36

Symbology Matrix 25 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label (s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 I 1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 I 0 0 1st Set Complete %4 I 0 1 2nd Set Begin (Then scan value in Appendix A) %4 I 0 0 2nd Set Complete %4 I 0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C4 + Save Configuration 37

Symbology Start Configuration CODABAR/NW7 Set Up Start/Stop Characters Upon Transmission ON %0 J H1 %0 J H0 <OFF> Transmission Type of Start/Stop %0 4 V F <A/B/C/D> <Start> %0 4 F F %0 4 V 1 %0 4 F 1 %0 4 V 2 %0 4 F 2 %0 4 V 4 %0 4 F 4 %0 4 V 8 %0 4 F 8 <A/B/C/D> <Stop> A Start A Stop B Start B Stop C Start C Stop D Start D Stop 38

Symbology CODABAR/NW7 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label (s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 J 1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 J 0 0 1st Set Complete %4 J 0 1 2nd Set Begin (Then scan value in Appendix A) %4 J 0 0 2nd Set Complete %4 J 0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C5 + Save Configuration 39

Symbology Start Configuration Code 93 Check Digit Transmission %0 K N4 <Calculate Check 2 Digits & Not Transmit> %0 K N3 Do Not Calculate Check Digit 40

Symbology Code 93 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 K 1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 K 0 0 1st Set Complete %4 K 0 1 2nd Set Begin (Then scan value in Appendix A) %4 K 0 0 2nd Set Complete %4 K 0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C6 + Save Configuration 41

Start Configuration Code 11 Symbology Check Digit Transmission %0 L N3 <Do Not Calculate Check Digit> %0 L N7 Calculate Check 1 Digit & Transmit %0 L N5 Calculate Check 1 Digit & Not Transmit %0 L N6 Calculate Check 2 Digits & Transmit %0 L N4 Calculate Check 2 Digits & Not Transmit 42

Symbology Code 11 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label (s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4L1+ Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4L00 1st Set Complete %4L01 2nd Set Begin (Then scan value in Appendix A) %4L00 2nd Set Complete %4L02 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C7 + Save Configuration 43

Symbology Start Configuration MSI/PLESSEY Check Digit Transmission %0 NN3 Do Not Calculate Check Digit %0 NN7 Calculate Check Digit & Transmit %0 NN5 <Calculate Check Digit & Not Transmit> 44

Symbology MSI/PLESSEY End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label (s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 N1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 N0 0 1st Set Complete %4 N0 1 2nd Set Begin (Then scan value in Appendix A) %4 N0 0 2nd Set Complete %4 N0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 C9 + Save Configuration 45

Start Configuration LCD 25 Symbology Check Digit Transmission %0 QN3 <Do Not Calculate Check Digit> %0 QN7 Calculate Check Digit & Transmit %0 QN5 Calculate Check Digit & Not Transmit 46

Symbology LCD 25 End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label (s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> %4 Q1 + Fix Length (2 Sets Available) 1st Set Begin (Then scan value in Appendix A) %4 Q0 0 1st Set Complete %4 Q0 1 2nd Set Begin (Then scan value in Appendix A) %4 Q0 0 2nd Set Complete %4 Q0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 CC+ Save Configuration 47

Symbology Start Configuration Telepen Type of Code <Full ASCII Mode> %0 T 8 0 %0 T 8 8 Compressed Numeric Mode Check Digit Transmission %0 T N3 Do Not Calculate Check Digit %0 T N5 <Calculate Check Digit & Not Transmit> %0 T N7 Calculate Check Digit & Transmit 48

Symbology Telepen End Configuration Set Up Code Length To set the fixed length: 1. Scan the "Begin" label of the desired set. 2. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the length to be read. 3. Scan the "Complete" label of the desired set. Repeat the steps 1-3 to set additional lengths. <Variable> Fix Length (2 Sets Available) %4 T 1 + 1st Set Begin (Then scan value in Appendix A) %4 T 0 0 1st Set Complete %4 T 0 1 2nd Set Begin (Then scan value in Appendix A) %4 T 0 0 2nd Set Complete %4 T 0 2 Minimum Length Begin(Then scan value in Appendix A) %2 + - / Complete %2 CF + Save Configuration 49

Symbology Start Configuration GS1 Databar (RSS Code) RSS-14 Parameters %0 UN7 <Transmit Check Digit> %0 UN5 Do Not Transmit Check Digit %0 U8 8 <Transmit Application ID> %0 U8 0 Do Not Transmit Application ID %0 U4 4 Transmit Symbology ID %0 U4 0 <Do Not Transmit Symbology ID> RSS Expanded Parameters %0 W44 Transmit Symbology ID %0 W40 <Do Not Transmit Symbology ID> 50

Symbology End Configuration GS1 Databar (RSS Code) RSS Limited Parameters <Transmit Check Digit> %0 VN7 Do Not Transmit Check Digit %0 VN5 <Transmit Application ID> %0 V8 8 Do Not Transmit Application ID %0 V8 0 Transmit Symbology ID %0 V4 4 <Do Not Transmit Symbology ID> %0 V4 0 Save Configuration 51

Operation Start Configuration Language Selection %0 Z V 0 <US English> %0 Z V 1 UK English %0 Z V 2 Italian %0 Z V 3 Spanish %0 Z V 4 French %0 Z V 5 German %0 Z V 6 Swedish %0 Z V 7 Switzerland %0 Z V 8 Hungarian Japanese %0 Z V 9 52

Operation End Configuration Language Selection Belgium %0 Z V A Portuguese %0 Z V B Denmark %0 Z V C Netherlands %0 Z V D Turkey %0 Z V E Reserved2 %0 Z V F 53 Save Configuration

Start Configuration Bar Code ID Operation %0 0 H1 ON %0 0 H0 <OFF> Default %913+ With this function ON, a leading character will be added to the output string while scanning code, user may refer to the following table to know what kind of bar code is being scanned. Please refer to the table below for matching code ID of codes read in. Code Type ID Code Type ID UPC-A A UPC-E B EAN-8 C EAN-13 D CODE 39 E CODE 128 F Interleave 25 G Industrial 25 H Matrix 25 I Codabar/NW7 J CODE 93 K CODE 11 L China Postage M MSI/PLESSEY N Code 2 of 6 P LCD25 Q Telepen T RSS-14 U RSS Limited V RSS Expanded W User Define Code ID To set the code ID: 1. Scan the symboligies label. 2. Go to the ASCII Tables in Appendix B, scan label that represents the desired code ID. Note: User define code ID will override default value. Program will not check the conflict. It is possible to have more than two symboligies which have same code ID. 54

Operation End Configuration Bar Code ID UPC-A %9 1 A + UPC-E %9 1 B + EAN-13/JAN-13 %9 1 Y + EAN-8/JAN-8 %9 1 Z + CODE 39 %9 1 E + CODE 128 %9 1 F + CODABAR/NW7 %9 1 J + Interleave 25 %9 1 G+ Industrial 25 %9 1 H+ Code 2 of 6 %91P+ Matrix 25 %9 1 I + Save Configuration 55

Start Configuration Bar Code ID Operation %9 1 K + CODE 93 %91L+ CODE 11 %9 1 M+ China Postage %9 1 N+ MSI/PLESSEY %91Q+ LCD25 %91T+ Telepen %91U+ RSS-14 %91V+ RSS Limited %91W+ RSS Expanded 56

Operation End Configuration Misc. Parameters Accuracy <1 Time> %0130 2 Times %0131 3 Times %0132 4 Times %0133 Sensitivity of Continuous Reading Mode <Fast> %0388 Slow %0380 Same Code Delay Reading Interval Begin (Then scan value in Appendix A) %30000 Complete %30001 Save Configuration 57

Operation Start Configuration Misc. Parameters Buzzer Beep Tone <High> %0 1 J 3 %0 1 J 2 %0 1 J 1 %0 1 J 0 Medium Low OFF PnP/Notebooks %0340 <Disable> %0344 Reverse Output Characters %0 3 H0 Enable <Disable> %0 3 H1 Enable LED Control %09O8 <ON> %09O0 OFF 58

Operation Setup Deletion End Configuration Setup Deletion To setup the deletion of output characters: 1. Scan the label of the desired set below. 2. Scan the label of the desired symboligy. 3. Go to the Decimal Value Tables in Appendix A, scan label(s) that represents the desired position to be deleted. 4. Scan the "Complete" label of "Character Position to be Deleted". 5. Go to the Decimal Value Tables in Appendix A, scan label (s) that represents the number of characters to be deleted. 6. Scan the "Complete" label of "Number of Characters to be Deleted". Repeat the steps 1-6 to set additional deletion. Select Deletion Set Number 1. 1st Set %800+ 2. 2nd Set %801+ 3. 3rd Set %802+ 4. 4th Set 5. 5th Set 6. 6th Set %803+ %804+ %805+ 59 Save Configuration

Operation Start Configuration Setup Deletion Symboligies Selection %8 1 A + UPC-A %8 1 B + %8 1 Y + UPC-E EAN-13/JAN-13 %8 1 Z + EAN-8/JAN-8 %8 1 E + CODE 39 %8 1 F + CODE 128 %8 1 J + CODABAR/NW7 %8 1 G+ %8 1 H+ Interleave 25 Industrial 25 %8 1 I + Matrix 25 %8 1 K + %81L+ CODE 93 CODE 11 60

Operation End Configuration Setup Deletion China Postage %8 1 M+ MSI/PLESSEY %8 1 N+ Code 2 of 6 %8 1 P + Telepen %81T+ LCD25 %81Q+ RSS-14 %81U+ RSS Limited %81V+ RSS Expanded %81W+ All Codes %8 1 S + None %814+ 61 Save Configuration

Start Configuration Setup Deletion Character Position to be Deleted Operation 1. Scan Decimal Value in Appendix A first. %820+ 2. Complete Number of Characters to be Deleted 1. Scan Decimal Value in Appendix A first. %830+ 2. Complete 62

Operation Setup Insertion End Configuration Setup Insertion To setup the insertion of output characters: 1. Scan the label of the desired set. 2. Scan the label of the desired symboligy. 3. Go to the Decimal Value Tables in Appendix A, scan label (s) that represents the desired position to be inserted. 4. Scan the "Complete" label of "Character Position to be Inserted". 5. Go to the ASCII Tables in Appendix B or Function Key Tables in Apendix C, scan label(s) that represents the desired characters to be inserted. 6. Scan the "Complete" label of "Characters to be Inserted". Repeat the steps 1-6 to set additional insertion. Select Insertion Set Number 1st Set %500+ 2nd Set %501+ 3rd Set %502+ 4th Set %503+ 5th Set %504+ 6th Set %505+ 63 Save Configuration

Operation Start Configuration Setup Insertion Symboligies Selection %5 1 A + UPC-A %5 1 B + UPC-E %5 1 Y + EAN-13/JAN-13 EAN-8/JAN-8 %5 1 Z + %5 1 E + %5 1 F + %5 1 J + CODE 39 CODE 128 CODABAR/NW7 Interleave 25 %5 1 G+ Industrial 25 %5 1 H+ Matrix 25 %5 1 I + CODE 93 %5 1 K + CODE 11 %51L+ 64

Operation End Configuration Setup Insertion China Postage %5 1 M+ MSI/PLESSEY %5 1 N+ Code 2 0f 6 %5 1 P + Telepen %51T+ LCD25 %51Q+ RSS-14 %51U+ RSS Limited %51V+ RSS Expanded %51W+ All Codes %5 1 S + None %514+ Save Configuration 65

Start Configuration Setup Insertion Character Position to be Inserted Operation 1. Scan Decimal Value in Appendix A first. %520+ 2. Complete Characters to be Inserted 1. Scan ASCII Table in Appendix B first. %530+ 2. Complete 66

End Configuration Setup IR Sensor Setup IR Sensor (BS-9705 Only) <Disable> %0 XH0 Enable %0 XH1 67 Save Configuration

Appendix A Decimal Value 0 1 2 3 4 5 6 7 8 9 68

Appendix B ASCll Tables NULL 00 ETX 03 ACK STX 02 ENQ 05 SOH 01 EOT 04 BEL BS 06 07 HT 08 LF VT 09 0A FF 0C SI 0B SO 0E CR 0D DLE DC2 DC1 0F 10 DC4 DC3 12 13 11 NAK 14 SYN ETB 15 16 CAN 17 EM SUB 18 19 ESC 1B RS 1A GS 1D FS 1C US 1E 1F 69

ASCll Tables Appendix B SPACE! 20 " 21 # $ 23 24 22 % & 25 ' 26 27 ) * 29 2A, - ( 28 + 2B 2C. 2D / 0 2F 30 2 31 3 32 33 5 34 6 35 36 8 37 9 38 39 ; 3A < 3B > 3D? 2E 1 4 7 : = 3C 3E 3F 70

Appendix B ASCll Tables @ A 40 41 C B 42 43 44 E D F 45 G 46 47 H I 48 J 49 4A K L 4C O 4B N 4E M 4D P 4F 50 Q R 51 S 52 53 T U 54 V W 55 56 X 57 Y 58 59 [ \ Z 5A 5B ^ 5E ] 5D 5C _ 5F 71

ASCll Tables Appendix B ` a 60 61 b c 62 d 63 64 e f 65 g 66 67 h i 68 j 69 6A k l 6C o 6B n 6E m 6D p 6F 70 q r 71 s 72 73 t u 74 v 75 76 w x 77 y 78 79 { z 7A 7B } 7C ~ DEL 7D 7E 7F 72

Appendix C Function Key Tables F1 F2 C0 C1 F4 F3 C2 F5 C3 F7 F6 C5 C4 F8 C6 F9 C7 F10 C8 F11 C9 Insert F12 CB CA Delete CC Page Up Home CE CD Page Down CF Left End D1 D0 Right D2 Up D3 Down D4 D5 73

V3.8 0145-85E00K1