um260 Backup Battery Kit

Similar documents
1. Carefully unpack the um260 s shipping carton and check the contents for damage.

289H LSS Installation & Operations Manual Overview

2. Site Planning lists the prerequisites and physical requirements for installing the 289H M LSS monitor.

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

VS Series 120V 600VA 300W Line-Interactive Desktop UPS, Tower, 6 Outlets

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Click Desktop Kit. Click Desktop Kit

Models HP Tablet Charging Module HP Charging Module LAN Kit

Installation Job Aid for Ethernet Routing Switch 3600 Series

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

IST ULTRASTAB Power Supply for high precision transducers

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Selectable test current and resistance ranges

Quick Start Installation Guide

XUK8TAKSMM12 photo-electric sensor - XUK - diffuse - Sn 5m 1Q auto PNP/NPN

CLEVELAND CONTROLS MODEL 6650 DIGITAL MANOMETER INSTRUCTION MANUAL DM

iconverter 2-Module Power Chassis

IST ULTRASTAB Power Supply for IT/ITN ULTRASTAB transducers

Avanti HP Series Centrifuges Preinstallation

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Energy Meter and. Current Transducer. Assembly Manual

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Installation Job Aid for VSP 4450GTX-HT- PWR+

DIMENSION/WEIGHT kpa. 0 to 20 m / 0 to 60 ft 0 to 2 bar / 0 to 29 psi. 0 to 50 m / 0 to 160 ft 0 to 5 bar / 0 to 72.5 psi

OmniSmart 230V 350VA 225W CE/IEC Medical Grade Line-Interactive UPS with Built-In Isolation Transformer

Phone: Fax: For calls outside the US please call:

Technical Specifications

Junos WebApp Secure 5.0 Hardware Guide

Dell MD1280 Storage Enclosure Getting Started Guide

User Manual. Heavy Duty Hot Wire CFM Thermo-Anemometer. Model

PowerShield 8. Installation Manual

System Specifications

IRM-5000P. insulation resistance meter. Vanguard Instruments Company, Inc.

2U Congestion Alert Rack Insert for UK

DVI ELR Extender over one CAT5

Installation Job Aid for VSP 4850GTS

PHOENIX CONTACT - 05/2007

Dual Link DVI Extender

M A C 3 Wind Speed Alarm & Controller

SmartPro 120V 700VA 450W Line-Interactive Sine Wave UPS, Tower, 120 or 230V input, Network Card Options, USB, DB9

Draper Low Voltage, Remote Control, Serial and Network Wiring Guide

MP7. Uninterruptible Power Supply

Power Supply and Fan Module Installation

DisplayMaker UV Curable Inkjet Printers

Bulletin 871D Cylinder Position Inductive Style

PHASE ONE Series 700: Uninterruptible Power Supply (UPS) Systems

Power Enclosure Components

MONITORING INTELLIRACK USER MANUAL

Section 11. Electrical System. 42--CF200--MA--09 (formerly 42-65) Issued 5/96 P/N B. E 1996 Nordson Corporation All rights reserved

Audio. one CAT-5 EXT-DVI-1CAT5-SR. User Manual. Release A2

1875 Smart Calibrator. Instruction Manual

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure

This data sheet is only valid in association with the IL SYS INST UM E user manual.

Cisco Redundant Power System 2300

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

Dual 4K 60Hz Monitor Thunderbolt 3 Dock with 6x USB 3.0 Ports

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

OmniVS 230V 800VA 475W Line-Interactive UPS, USB port, C13 Outlets

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

Displays Transducers. Displays and transducers

Sorensen SG Series - Water Cooled kw V A. Programmable Precision High Power DC Power Supply

Photoelectric Sensors Enhanced 50 Series

General information. Display. Supply voltage

OmniSmart 120V 330VA 225W UL Medical Grade Line-Interactive UPS, Tower, DB9 Serial

10A Micro-Ohmmeter Model 6240

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

F-1000 DIGITAL PADDLEWHEEL FLOWMETER

IB ST 24 AO 4/EF. INTERBUS-ST analog output module, 4 outputs, 0-10 V, ±10 V, 0-20 ma, 4-20 ma. Data sheet. 1 Description

Andover Continuum. Power Supplies with or without UPS

IB IL 24 DI 16 IB IL 24 DI 16-PAC

NETRONICS HS3500 CONTROLLER

BC Personal 120V 450VA 280W Standby UPS, Tower, USB port, 3 Outlets

86 mm sq. (3.39 inch sq.)

Note: the wiring of the dead-man buttons has been changed since October 2001.

MAC3 Wind Speed Alarm & Controller. Installation Instructions

DisplayPort Booster. EXT-DP-141B User Manual.

DVI ELR Extender over one CAT5

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Intelligent DC UPS Module 12V/9~36V DC Input, 12V DC Output Uninterruptible Power Supply Module with Diagnostics

Power Supply Installation

General Purpose Chassis for PXI and CompactPCI

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

1:4 Splitter for DisplayPort

GRASSO SYSTEM CONTROL

Micro-Ohmmeters. Digital 10A. Models 6240 & Measure low resistance with high accuracy. Technical Hotline: (800)

Cisco Prisma II Platform

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

General information. Display. Supply voltage

2G Engine Installation

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

GT-A81051-XXYY SERIES 5W

829MA 6 and 829MB 6 Data Mountings

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

Prisma II Platform. Optoelectronics

Pressure switch KP. Data sheet

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Transcription:

um260 Backup Battery Kit Overview The System Studies um260 Micro Monitor (Part No. 9800-6260M) is a -48V DC-powered small-office monitor designed for a variety of monitoring applications. To make it possible to install the um260 at remote air dryer and CEV hut locations where 115V AC is used to power equipment, System Studies provides a um260 Backup Battery Kit (Part No. 9800-4848BBU). The primary components included in the kit are a 115V AC to -48V DC Power Supply, a backup Battery Unit, and a 6-pair um260 Termination Adapter. These components not only make it possible to place the monitor in operation, they also offer emergency backup power and the abil - ity to detect AC power failures. Note: Customers who wish to purchase the above components, plus a um260 Micro Monitor (modem version) and a flow measurement assembly installed in a rugged plastic cabinet can order a Remote Dryer Monitoring Kit (Part No. 9800-4849). Four flow ranges are available: 0-9.5, 0-19, 0-47.5 and 0-95 Standard Cubic Feet per Hour (SCFH). The information in this document describes the functions of the individual compo - nents supplied in the um260 Backup Battery Kit and suggests how to wire and as - sign device numbers for the monitored pressure, flow and contact alarm devices. Kit Components -48V DC Power Supply Battery Unit As shown in Figure 1 the -48V DC Power Supply includes a 3-conductor cord with a UL certified 3-prong plug for making a connection to the AC power source.* It also includes a DC-out adapter cord that plugs directly into the Battery Unit. The Battery Unit is supplied with a blue, blue/white -48V DC power pair (to connect outgoing DC power to the um260) and an orange, orange/white AC power alarm pair. These pairs, as well as both power supply cords, are six feet in length. * In applications where a hard-wire connection is required to the 115V AC power source, System Studies recommends contracting a licensed electrician to perform the work. Battery Life Depending upon the ambient temperature at the installation, the Battery Unit can provide approximately two to three hours of uninterrupted power to the um260 if there is a disruption of AC power. The Battery Unit is supplied with an enable/disable switch which prevents battery discharge during shipment and storage. System Studies Incorporated (3691209.GHD) 1

Figure 1 um260 Backup Battery Kit Components Termination Adapter The kit s Termination Adapter makes it possible to connect up to three resistive or current loop transducer pairs, an air dryer contact alarm pair, the AC alarm pair, and one additional contact alarm to the um260 monitor. In the past it was necessary to use a larger wire-wrap block and 25-pair Amphenol cable to make monitoring device pair connections to the um260. With the um260 Termination Adapter, monitored pairs can be connected quickly and easily using the connector s locking terminal jaws. Once the pairs are securely in place, the adapter can be inserted into the um260 s Amphenol cable receptacle. Note: A small, reversible standard/phillipshead screwdriver is also provided to help secure the monitoring pairs to the Termination Adapter. 2

Pressure and Flow Monitoring Monitored Flow Finder Assembly For a new um260 installation at a remote dryer cabinet or hut location, a System Studies Flow Measurement Assembly (Part Nos. 9800-3063, -3066) will need to be installed to monitor remote dryer delivery pressure and air flow rates. The Flow Measurement Assembly is equipped with a High Resolution Dual (pressure and flow) Transducer, which pneumatically connects to an on-board Flow Finder. Termination Adapter Configuration As shown in Figure 2, there are two groups of six locking jaw connectors on the Termination Adapter. The left side is designated for binary contact devices, and the right side is used for transducers. Suggested Wiring It is recommended that you insert the orange, orange/white AC power alarm pair into the two jaws labeled 1-1; the incoming dryer alarm pair should be inserted into jaws 1-2. Unless another binary device is being monitored at the remote air dryer site, the outside left pair of jaws will not be used. As stated above, the six terminal jaws on the right side of the adapter are used for the transducers. The far right pair in this group (2-1) is recommended for connecting the blue, blue/white flow transducer pair, followed by the orange, orange/white pressure tranducer pair (2-2). Once again, unless a third tranducer is monitored, jaws 2-3 will not beused. Figure 2 6-Pair Termination Adapter System Studies Incorporated (3691209.GHD) 3

Device Programming Information Data Entry Recommendations For the type of installation described above, the um260 will need to be programmed using the following Device Numbers, Device Types and Transducer Types shown in the table on the next page. If PressureMAP is being used to monitor the um260, data entry can be performed directly into the PressureMAP data entry editor. Sensor Device Number Device Type Transducer Type Flow Transducer 2-1 RF * CF/9.5, CF/19, CF/47, or CF/95 PressureTransducer 2-2 RP CPA30 AC Alarm 1-1 CA or RA CPAMS_TD Contact Alarm 1-2 CA or RA CPAMS_TD * Flow range designation depends on range of Flow Measurement Assembly s Flow Finder. Specifications Ordering Part No.: 9800-4848-BBU Power Supply Length: 3-3/4 in (9.53 cm) Width: 2-1/2 in (6.35 cm) Height: 1-1/2 in (3.81 cm) Input: 100-240V AC, 50/60 Hz, 0.5 A, 6 ft (1.83 m) cord, 3-prong AC plug connector Output: 42-50V DC, 0.42-0.36 A 6 ft (1.83 m) cord, plug-in connector specific to battery unit Labels: UL, CE amd TUV listed Battery Unit Length: 6-3/4 in (4.25 cm) Width: 3-1/2 in (8.89 cm) Height: 1-1/2 in (3.81 cm) Output: -48V DC power to um260 twisted pair, 26 gauge, orange, orange/white insulation, 6 ft (1.83 cm supplied) AC Alarm twisted pair, 26 gauge, blue, blue/white insulation, 6 ft (1.83 cm) Temperature Range: 32 F (0 C) 135 F (57.2 C) Battery Life: 2 3 hours at 70 F (21.1 C); 45 min. at 32 F (0 C) 4

Termination Length: 3-1/4 in (8.26 cm) Adapter Width: 2-1/2 in (6.35 cm) Height: 1 in (2.54 cm) Connector: male plug-in Amphenol (to um260 monitor) Wiring: 6 pairs 3 transducers (resistive or ma) 3 binary devices Kit Shipping Weight 3 lbs (1.36 kg) System Studies Incorporated (3691209.GHD) 5