Condition Report. Sale /10/ :00:00 - Medical Equipment Auction - PART :00. Sale Date

Similar documents
Condition Report. Olympus CYF-4A Fiber Cystoscope SN

Endoscopes Inspection Report Sale: 1406 Date: 13 / 05 / 2014 (Condition Reports for other items at the end of the Scopes Report)

Professional Health Solutions

Condition Report /09/ :00 - Endoscopy and General Medical Equipment - PART :00

Original Manufacturer

Rigel Medical. Leaders in biomedical test solutions. Performance Analyzers. Vital Signs Simulators. Electrical Safety Analyzers

SpO 2 Upgrade Instructions

5.6" Multi-function Monitor

Delta 1600 User Manual

Condition Report /09/ :00 - Medical Equipment Auction :00

Hardware and Components: Philips Monitors in Critical Care

Rigel SIM Range Accessory List. Innovating Together

Professional Health Solutions

Warning Before Installation. Package Contents EN - 1. Refer to your user's manual for the operating temperature.

An energy metering system that gives flexibility, security and control. Century House, Roman Road, Blackburn, BB1 2LD

TESA UPD Gauge Block Comparator with a 25 mm Measuring Span

FHD Driving Recorder E272S/S272W. Quick Start Guide

PRODUCT RANGE MEDICAL TEST EQUIPMENT FROM

MacBook Pro 13" Function Keys Late 2016 Trackpad Replacement

is your system The System Unique features to meet the individual needs of surgical specialties. The System Approach to Electrosurgical Excellence

Slide. The functional enclosure fits naturally into your hand, allowing for hours of stress-free use.

Brighten The World With

Resusci Anne Simulator

HLL Infra Tech Services Ltd. Amendment No. 3

Written By: Sam Lionheart

ipad SP2 Automatic External Defibrillator

Resusci Anne Advanced SkillTrainer

Written By: Sam Lionheart

COMTRONICS PRICE LIST

Amendment No. 02. Ref: (i) Tender No: HITES/PCD/AIIMS-BBSR/04/18-19 dated Section I Notice Inviting Tenders(NIT)

Auto-leveling Rotating Laser (RL430G)

Warning Before Installation

Welch Allyn Connex Vital Signs Monitor 6000 Power Supply Replacement

MacBook Pro 13" Touch Bar Late 2016 Display Assembly Replacement

Written By: Andrew Optimus Goldberg

COMTRONICS PRICE LIST

Vendor: Apple. Exam Code: 9L Exam Name: Apple Hardware Recertification exam. Version: Demo

Written By: Sam Lionheart

COMTRONICS PRICE LIST

LET OUR IMAGE ENHANCE YOUR IMAGE. Operating Instructions MedRx JVC Portable Video OtoScope System

Quick Installation Guide

imac Intel 27" EMC 2639 Hard Drive

URGENT Field Safety Notice Philips HeartStart MRx Monitor/Defibrillator

EO-MN910. User Manual. English (USA). 12/2014. Rev.1.0.

Impulse Series Camera User Guide

ipad Mini Wi-Fi Front Facing Camera Replacement

Motorola Moto Z2 Play Audio Jack Replacement

Unpack Your Scanner. Scanner. ArcSoft Suite CD-ROM. LaserSoft SilverFast Ai 6 CD-ROM with IT8 targets (1640XL Graphic Arts Edition only)

RAD system. C- arm. Price 337,500 SDG. Mobile C-arm: Model OPESCOPE Activo. 2 monitors. Easy to use. Quick c-arm positioning. Simple operation.

Operating manual PNU Porsche Navigation Upgrade

ipad Mini 2 Wi-Fi Front Panel Assembly Replacement

Table of Content. Part I Introduction

Fast Start Guide Sony Cukor Camera. Cukor Camera-- Fast Start Guide

Aegis Padlock SSD. User Guide. Remember to save your PIN in a safe place. If lost or forgotten, there is no way to access the drive.

Electrosurgery. DYONICS RF-S WHIRLWIND 90 Probe. DYONICS EFLEX Radiofrequency Probes. Powerful high-flow suction aids in rapid tissue removal

Amendment No: 2 Date: 13/09/2013

PhotoScanner. User Guide

DVR101 HD DASH CAM & 12MP CAMERA

MCD The Football Users Manual. MCD-4800 USERS MANUAL Ground Control V.1.9

Instructions. Remote Controlled Rotator RCR

Manual Iphone 5 Charger Cable Not Working Ios 7 Update

Unit Test Calibration Training. (QL420+ & RW420) Mobile Printers

Warning Before Installation. Package Contents EN-1. Power off the Network Camera as soon as smoke or unusual odors are detected.

RF-Link 2.4GHz Digital Wireless Color Security/Baby Monitor. Model: ABM-4161 User's Manual

User Manual Version 1.0

Iphone 5 Manual Charging Cable Not Working Ios

Model XL-2 - Fluid Leak Detector

Using the NEC MobilePro

TAB 10 USER GUIDE. Please read this guide before first use

midi LOGGER 900 SERVICE MANUAL GL900-UM-251 GL900-UM

STEP 2: VITALSBRIDGE TO PATIENT MONITOR CONNECTION GUIDE VITALSBRIDGE AND 100

Living. Keyfree Connected Smart Lock Manual. smart. The smarter way to protect your home

Iphone 5 Manual Charge Cable Not Working Ios 7

FDS3NAV2. For Ford Vehicles Equipped With SYNC3. Installation Instructions. Calibration and Setup Guide. Page 1 of 14

If you get stuck at any point, please let us know! We love talking to our customers! You can reach us at the number below:

DOOR INTERCOM SYSTEM WITH 2.4 COLOUR LCD

Headstrap magnifier with multiple lenses

Installation Manual on Continuous ink supply system (CISS) For printer Canon IP 4000

BBDB-FF02E User Manual

ipod Touch 5th Generation Rear-Facing Camera Replacement

Mini Recessed PIR. Model: PDFM360MINI. Installation & Operating Instructions

Propaq LT Monitors. Propaq LT Base Model. Propaq LT with Wireless Option/ Legendary quality and durability Heart rate, 3-or 5-lead ECG, SpO 2

CRESCENDO /PB G3. Processor Upgrade Card for Macintosh PowerBook 1400 Series Computers. Quick Start Guide for Crescendo/PB G3

Exam Questions 9L0-314

Iphone 5 Manual Charger Cable Not Working Ios 7 Update

A Guide on How to use the Canon Power Shot A 95 Digital Camera

Contents WHAT IS BCA ASSURED KEY INFORMATION FAQS THE ASSURED REPORT - ENGINE BAY THE ASSURED REPORT - ENGINE RUNNING THE ASSURED REPORT - TYRE TREAD

Independence and Safety Wherever You Go

THE OPERATOR INTRODUCTION 2 ACCESSING YOUR SYSTEM 2 FUNCTIONS OF THE "OPERATOR" 3 PROGRAMMING/CHANGING ACCESS CODES 12 ACTIVATING EMERGENCY ALARMS 13

Redigido por: Sam Lionheart

Warranty 3 Auditory feedback and headphones 11. General care 3 Access options Grid Pad Go 4-7 Shoulder strap 14

TG607x_QG(e).fm Page 1 Tuesday, December 5, :55 PM. Click. To single-line telephone jack (RJ11C)

CU-SP1 INTELLIGENT PUBLIC ACCESS DEFIBRILLATOR. Medical and Surgical Requisites Pty Ltd

xponent Version 4.2 RELEASE NOTES

ipad mini 4 LTE Screen and Digitizer Replacement

B R E A T H A L Y S E R

Printer Driver. User Guide. Macintosh

HDAF800 HD 1080p Digital Microscope USB drive for Image Capture

M Series AHA/ERC Guidelines 2005 Software Configuration Overview

CF3000 Dealer Diagnostic Tool Instruction Manual

Transcription:

Condition Report Sale Sale Date Location: Viewing: Removal: 1820-09/10/2018 10:00:00 - Medical Equipment Auction - PART 2 09-10-2018 10:00 Malmesbury, Wiltshire, UK Friday 5th October 12pm - 5pm, Monday 8th October 10am - 6pm and the morning of the sale from 8:30am By 4pm on Tuesday 16th October 2018 - Late collection charges will be incurred after this date These reports are compiled by our Medical Engineering Team and are for guidance only - all lots are sold as seen, as per our Conditions of Sale. We recommend that wherever possible you inspect lots prior to purchase. Lot 806 Lot 807 Valleylab Force EZ Diathermy with Foot Switches The electrosurgical unit powers up and displays error "160". No further checks carried out. Trolley and footswitches are included. The front panel has some marks. Overall the unit is in satisfactory physical condition with minor signs of wear. Litechnica Selector Deux Yag Laser The unit is in satisfactory physical condition but has not been tested (one of the cables going to the control unit/table has been cut). The chin rest platform is missing and the unit is not secured to the table. Eyepieces are included. The motorised table is functional. ON/OFF key is not included. Lot 809 Lot 852 Erbe ICC 200 Diathermy (No Footswitch) Display panel and controls are in good working order. The patient plate alarm and indicator are functional, both bipolar and monopolar modes are working. Tested with electrosurgical analyser and the output power from all modes (cut, coagulation and bipolar) were within the limits at the time of test. The footswitch is not included. Overall the unit is in satisfactory physical condition with minor signs of wear. 2 x Dyonics 300XL Lightsource One unit appears to be faulty. No light output and a clicking sound. The other is working fine with good power light output and brightness adjustments. Overall physical condition of both units is good. Page 1 Updated 09 October 2018

Lot 885 Agilent Heartstream XL Defibrillator with Philips Test Load / Leads CF1627 The defibrillator powers on and passes its self checks OK. Patient monitoring through ECG and PAD are functional. One chock has been performed in AED mode and the results are satisfactory. Battery was operational during tests but has not been fully tested. Printer is working fine. Voice prompts were loud and clear. Good overall condition of the unit has been observed. Lot 887 Lot 929 2 x Datex Ohmeda Patient Monitors CF3383, 2665 Both patient monitors power up and complete the initial system self test successfully. Display panel, function keys and rotary control knob are in good working order. One of the monitor includes a E-PSM module. Available parameters for the module are ECG, SpO2, NIBP and Temperature. When tested with a patient simulator good ECG, NIBP and SpO2 readings were obtained. Backup batteries were working at the time of the test. One of the monitors front panel is slightly detached, the plastic cover for the alarm is missing. Overall the units are in reasonable physical condition with minor signs of wear. YOM: 2005-2008 Philips Heartstart XL Defibrillator The defibrillator powers on and passes its self checks OK. Patient monitoring through PADs is functional. One chock has been performed in AED mode and the results are satisfactory. There is no ECG leads and therefore ECG function was not tested. Also there is no battery available. Printer was not tested. Voice prompts were loud and clear. Good overall condition of the unit has been observed. Lot 972 Lot 1035 4 x Alaris PK Syringe Pumps All four syringe pumps power up ok. Display panels and controls are in good working order but no further checks have been carried out. One of the units displays "Require service". The batteries were found to be low at the time of the test. Overall the units are in satisfactory physical condition with minor signs of wear. Canon RK-F1 Full Auto Ref Keratometer The unit powers up and completes the initial system self test successfully. Display screen, control panel and trackball are in good working order. The camera is also Page 2 Updated 09 October 2018

functional and produces clear images but the system has not been fully tested. Chin rest adjustment and motorised table are in good working order. Overall the unit is in reasonable physical condition with minor signs of wear. Lot 1067 Lot 1077 Erbe ICC 300 Display panel and controls are in good working order. The patient plate alarm and indicator are functional, both bipolar and monopolar modes are working. Tested with electrosurgical analyser and the output power from all modes (cut, coagulation and bipolar) were within the limits at the time of test. The footswitch is not included. Trolley is included. Overall the unit is in reasonable physical condition with some scratches and signs of wear. Welch Allyn Schiller AT-2 Plus ECG Pagewriter with Leads 2218 The unit powers on OK and passes its self checks ok. Main softkeys panel is loose (when pressing one key it goes down returning when release). Also, when tested with a patient simulator, only ECG lead number 3 is reading ECG signal (could be ECG leads or unit itself). Battery mode was working at the time of tests (short time of tests therefore battery mode was not fully tested). Overall condition of the pagewriter ia average. Lot 1081 Manufactured: Medrad Mark V Pro VIS Injector 06 2002 The contrast injector is physically intact and in reasonable condition. The unit could not be tested as the system requires connection to the main control unit. Hand control push button is included. Last calibration date: January 2018. Lot 1088 MAC 1200 ST ECG with Leads 134269 All ECG signals are present but with presence of some noise in the signal. Printer is functional. The ECG cable is in good condition (almost new). Battery mode was working at the time of tests. Overall this unit is in reasonably good condition. Page 3 Updated 09 October 2018

Lot 1098 GE MAC 1200 ST ECG Recorder/Leads All ECG signals are present. Printer is functional. The ECG cable is in good condition (almost new). Battery mode was working at the time of tests. Overall this unit is in good condition. Lot 1099 GE MAC 1200 ST ECG Recorder/Leads All ECG signals are present. Printer is functional. The ECG cable is in good condition (almos new). Battery mode was working at the time of tests. Overall this unit is in reasonably good condition. Lot 1100 GE MAC 1200 ST ECG Recorder/Leads All ECG signals are present. Printer is functional. The ECG cable is in good condition (almos new). Battery mode was working at the time of tests. Overall this unit is in reasonably good condition. Lot 1110 Agilent Heartstream XL Defibrillator with Battery, ECG Lead and Test Loader SN The defibrillator powers on and passes its self checks ok. ECG signal through pads are working fine. The unit was tested with a patient simulator and one chock was delivered in AED mode. The results are satisfactory. The available ECG leads are not compatible with this defibrillator. Battery mode was working during the tests. Battery itself is having difficulties staying in place (constantly being ejected). Printer is working fine plus voice prompts are loud and clear. The unit is in good physical condition. Lot 1127 Valleylab Ligasure Vessel Sealing System and Foot Switch The Ligasure vessel sealing system powers up and completes the initial system self test successfully. Display panel and soft keys are in good working order. No further checks carried out. Overall the unit is in satisfactory physical condition. YOM: 2005. Page 4 Updated 09 October 2018

Lot 1174 Lot 1208 Lot 1209 Hill Rom Air Shields Resuscitataire The System powers up and display test is completed. The numerical displays, push buttons and soft keys are working fine. Pre-warm and manual mode are working and the radiant warmer heater can be adjusted. The Baby mode was not fully tested; skin temperature probe is not included. Overhead light is working fine. Pneumatic system was not tested. Mechanical cot tilt adjustment are working. Some of the soft keys are slightly worn. The grill of the radiant warmer heater is missing. One of the lateral plastic cover has a crack. The corners of the mattress cover are damaged. The unit is in fair physical condition. Valleylab Force EZ Diathermy with Footswitch, Optimum Smoke Evacutor Display panel and controls are in good working order. The patient plate alarm and indicator are functional, both bipolar and monopolar modes are working. Tested with electrosurgical analyser and the output power from all modes (cut, coagulation and bipolar) were within the limits at the time of test. The footswitches are in good working order. Trolley is included. The bipolar footswitch cable is slightly damaged close to the connector end. The smoke evacuator powers up and appears to be working but was not fully tested. The filter needs to be replaced. Overall the units are in satisfactory physical condition with some marks on the bipolar section and other minor signs of wear. Schaerer Axis Operating Table Model: Axis 600. YOM: 2002 All motorised positioning adjustments, base lock and hand control are in good working order. The battery found to be low at the time of test. Cushions are included and overall the operating table is in reasonable physical condition with minor signs of wear. Some of the cushions have sustained cuts. Lot 1247 2 x Philips Heartstart Defibrillators (CHO-10105, E16117) Both AEDs power up and complete the initial system self tests successfully. Display screens, buttons and voice prompts are in good working order. No further checks carried out. Battery is included with both defibrillators and the batteries are working (install by: 09/2016 and 01/2017). Overall the units are in reasonable physical condition. Lot 1332 GE Mac 1600 ECG Pagewriter with Leads The ECG recorder powers up and passes its self checks ok. Page 5 Updated 09 October 2018

LCD screen, panel softkeys and printer are all in good working order. The unit was tested with a patient simulator and all ECG signals were present but with some little noise in the signal. Battery mode was working at the time of tests. ECG leads, cart and castors are all in good condition. Good overall condition has been observed. Lot 1350 2 x Philips Intellivue MP70 Monitors Both monitors power on and passes theit initial self checks OK. LCD touch screen is functional with menus and sub-benus accessible. No further tests been performed. One monitor has a plastic facia crack on lower right corner. The other has plastic cracks at the power on key. Average overall condition has been observed. Lot 1361 Lot 1469 Valleylab Force EZ Diathermy with Footswitch, Optimum Smoke Evacutor Display panel, rotary knobs and controls are in good working order. The patient plate alarm and indicator are functional, both bipolar and monopolar modes are working. Tested with electrosurgical analyser and the output power from all modes (cut, coagulation and bipolar) were within the limits at the time of test. The footswitch is in good working order. Trolley is included. The front panel has some cuts on the coagulation and the bipolar sections. The smoke evacuator powers up and appears to be working but was not fully tested. The filter needs to be replaced. Overall the units are in satisfactory physical condition with minor signs of wear. Warm Touch Patient Warmer 32573 The unit powers on and the 4 temperature settings seems working accordingly but their actual temperature values have not been confirmed. The unit is in satisfactory overall condition. Lot 1477 Anetic Aid Electronic Tourniquet The unit powers on OK. Touch screen is responsive. The unit apears to be faulty. When valueas are to be set screen goes dark and unit is making "soft noises" (like air pump is trying to work). Good overall condition has been observed. Page 6 Updated 09 October 2018

Lot 1539 Lot 1540 Lot 1620 Hill Rom Air Shields Resuscitaire The System powers up and display test is completed. The numerical displays, push buttons and soft keys are working fine. Pre-warm and manual mode are working and the radiant warmer heater can be adjusted. The Baby mode was not fully tested; skin temperature probe is not included. Overhead light is working fine. Pneumatic system was not tested. Mechanical cot tilt adjustment are working. The cover for the suction unit is loose. One of the lateral plastic cover is missing. The unit is in fair physical condition. Hill Rom Air Shields Resuscitaire The System powers up and display test is completed. The numerical displays, push buttons and soft keys are working fine. Pre-warm and manual mode are working and the radiant warmer heater can be adjusted. The Baby mode was not fully tested; skin temperature probe is not included. Overhead light is working fine. Pneumatic system was not tested. Mechanical cot tilt adjustment are working. The grill of the radiant warmer heater is missing. One of the lateral plastic cover is missing. The unit is in fair physical condition. Smith & Nephew Leg Stretcher The unit powers on OK, is responsive and seems working accordingly but no further tests been performed. Average overall condition has been observed. Lot 1668 De Soutter Plaster Saw This unit powers on and is in good working condition. Stisfactory overall condition has been observed. Lot 1739 Lot 1753 Pair of Leg Supports for Operating Table Schmitz limb support attachments, model No./Ref: 101.227. One of the support has a damaged sponge. Operating Table with Accessories Medi-Matic This unit is partially dismantled on top of a pallet and with some cables disconnected. Unable to test. Good overall physical condition has been observed. The cushion looks new and no damage seen. Page 7 Updated 09 October 2018