Control Box CO61. Data sheet LINAK.COM/MEDLINE-CARELINE

Similar documents
Control Box CB16 OpenBus TM. Data sheet LINAK.COM/MEDLINE-CARELINE

Hand Control HL80. Data sheet LINAK.COM/MEDLINE-CARELINE

Actuator LA27. Data sheet LINAK.COM/MEDLINE-CARELINE

DESKLIFT TM DL5. Data sheet LINAK.COM/DESKLINE

DC Connector. Data sheet LINAK.COM/HOMELINE

DL2. Data sheet LINAK.COM/DESKLINE

Built-in DB6. Data sheet LINAK.COM/DESKLINE

Desk Panel DPF. Data sheet LINAK.COM/DESKLINE

DL8. Data sheet LINAK.COM/DESKLINE

Desklift DL10. Data sheet LINAK.COM/DESKLINE

DESKLIFT DL5 PRODUCT DATA SHEET

Actuator LA31. Data sheet LINAK.COM/DESKLINE

HOMELINE. Product overview LINAK.COM/HOMELINE

HOMELINE. Product overview LINAK.COM/HOMELINE

REDUNDANCY MODULE TSP-REM360 AND TSP-REM600

TECHLINE SYSTEM SOLUTIONS

iswitch imotor Compact QR

Compact single actuator systems for box spring beds

TECH-system Type 322 BASIC

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

EC centrifugal module - RadiPac

Industrial Power Supplies

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

TECHLINE iflex integrated Flexibility

INTRODUCTION The Monitor, interchangeable modules and storage batteries are described below. Refer to the table below for specifications.

EC axial fan - HyBlade

ASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Ă„nderungen vorbehalten /02

LSFC Power Factor Correction Systems

EC centrifugal module - RadiPac

OV1001 Part No OV1001 HEIGHT ADJUSTABLE TABLE USER GUIDE

Product and functional description

PHOENIX CONTACT - 01/2007

Power supply CP-D 12/2.1 Primary switch mode power supply

DESKLINE. Product overview LINAK.COM/DESKLINE

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

Description of parts Panel mounting Insert mounting without/with Carrier element Plastic housings

UPS Emergency Bed Power Unit

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

Switched-mode and uninterruptible power supplies, and electronic fuses. Let s connect. Power supply. Catalogue 2014/2015

Version E. Actuators. WMX 526 / 526 UL / 826 / 826 UL Chain actuator

63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.

TSP-BCM48, TSP-BCM48A. Operating Instruction Manual. Page 1 of 13

Switches and Indicators 84

EC centrifugal module - RadiPac

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

OV1000 Part No OV1000 HEIGHT ADJUSTABLE TABLE USER GUIDE

Focus on Pergolas LINAK.COM/TECHLINE

Gas Controller System DGC-06

AC5160 SiPass integrated controller kit

CONFIGURABLE SAFETY RELAYS

Technical Data Sheets Uninterruptible Power Supply LP11 Series UPS kva

Time Counters mini "h", DC Version

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Focus on Electric adjustment of Display and Monitor Stands

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals

SITOP in the SIMATIC Design

TECH system Type 288-SAF

J3C-H20DPS 25Nm Smart Electric Actuator Type: J3C Model: H20DPS

EC centrifugal module - RadiPac

Vandal-proof latching action switch MSM LA

SIPLUS S7-200 PS 203. Overview

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

ACTUATOR LA25 PRODUCT DATA SHEET

Product Discontinuation Notices. Discontinuation Notice of Safety Laser Scanner Type OS3101 series

SIRCO Load break switches for power distribution from 125 to 5000 A

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Power Supply HARTING pcon

Communication module to connect M-bus devices to POL6xx.xxx controllers.

V-3000 Series Miniature Basic Switches

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

NKQB24-1, NKQX24-1 On/Off, Fail-Safe, Operation, Direct Coupled, 24V

X-Beam Waterproof Action Camera Light USER GUIDE

Analog display for resistance current

SSR - Supplies - Relays

Overview of types. Technical data

Installation and commissioning guide SmartLink PSD Power Supply Module (DC)

Signal Doublers. VariTrans A 20300

100% electricity. Automatic transfer switch controllers ATL series

NKQB24-1, NKQX24-1 On/Off, Electronic Fail-Safe, Direct Coupled, 24V

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

Power Supply HARTING pcon

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Kuhnke Technical Data. Contact Details

Rotary version, three-position control

Hinged safety switches, Palladio line

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Industrial Power Supplies

M C. Ex d M-0... control, monitoring and signalling devices

PCS88-90 (Black) PCS88-94 (Silver)

PHOENIX CONTACT - 07/2006

* * Agilent Power Distribution Unit (PDU) Installation Guide

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

SRT2-ROC08, SRT2-ROC16

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

Transcription:

Control Box CO61 Data sheet LINAK.COM/MEDLINE-CARELINE

C061 The LINAK control box CO61 offers a consolidated range of unprecedented features all utilising standardised technology, interfaces and compatibility. The CO61 for LINAK actuators is intended for the control of, for example, hospital bed movement. Equipped with 200W SMPS, excellent and well thoughtout cable management as well as multiple easy mounting options, this control box opens up a wide range of application possibilities for the provident hospital and care products manufacturer. With the CO61, FET, IPX6 Washable DURA TM protection and a battery port, are all standard options. The entire product platform supports the LINAK principle One World One box worldwide operable and applicable. Features: Power supply: Universal, SMPS 200 W effect output (Switch Mode Power Supply) 100-240 VAC, 50/60 Hz -15% / +10% Mains indicator: Yes - Green LED (mains connected) Actuator interface: 4 channel, 6 pin Mini-Fit CO-Link: Link of primary and secondary CO61 - up to 8 channels and 2x200 W Hand control interface: 1 port, 10 pin modular plug Battery interface: 1 port, 4 pin Mini-Fit (output 300 ma when no actuators are running) Standby power: Approx. 0.5 W (120/230 V) Colour: Light grey (RAL 7035) Output short-circuit protected: Yes Control concept: FET (no relay noise) Power Supply Circuit Method: Half bridge Duty cycle: 10 % - 2/18 min. on/off continuous use. Maximum power is 200 W for 80 seconds and 100 W for 40 seconds at 25 C. Weight: Low weight 0.7 kg Actuator compatibility: Actuators with signal, feedback by hall and potentiometer Battery charger: Battery input available, No charger, but supports battery with internal charger Charging indicator: Supported by using BA21 Acoustic warning signal: Buzzer dongle add-on Battery alarm: Supported by using BA21 EOP: Yes IP-Rating: IPX6 Washable DURA TM Operation: True parallel (hall feedback) Max. current: 10 A/CH Accessories: OpenBus TM standard Power management: High speed at low loads and/or high loads at a lower speed Overload protection: The CO61 can reduce the output voltages to prevent overload Safety system: Thermally protected, Short-circuit protected, Hot-plugging protected Start/stop: Soft start/ direct stop Protection class: Class 2, Class 1 is possible with pigtail on mains cable Cable lock: Integrated in lid External power support (hand control output): 40 V/200 ma (polyfuse protection) Mounting: Compatible with a wide range of mounting brackets LINAK.COM/MEDLINE-CARELINE

continue Usage: Operation temperature: +5 C to +40 C Storage temperature: -10 C to +50 C Relative humidity: 20% - 90% at 30 C - not condensing Atmospheric pressure: 700 to 1060 hpa Meters above sea level: Max. 2000 meters Approvals: IEC60601-1 edition 3.1 ANSI/AAMI ES60601-1:2005/(R) 2012 CSA CAN/CSA-C22.2 NO. 60601-1:14 PSE Japan CO61 Ordering example: C O 6 + 0 9 4 2 1 S 0 9 0 0 0 Reserved for future use Reserved for future use Reserved for future use Class 9 = 2 Pole (without earth, class II) without cable Reserved for future use Software T = Without software X = Special customer software Voltages 1 = 100-240VAC -15%/+10% Effect Channels IP degree H-bridge Colour 2 = 200W 4 = 4 Channels 9 = IPX6 Washable DURA 0 = Half bridge + = RAL7035 light grey Model 6 Functionality Family O = Intelligent - OpenBus input C = Control Box

CO61 - System Overview HB20 HB30 HB70 HB80 HD80 HL70 FS3 ACO ACC ACK ACOM FPP IRO MJB DJB One signal output CO-Link BA21 BA19 CO61 CO41 CO61 CO71 Power outputs (1-4 channels) LA23 LA27 LA29 LA31 LA34 LA40 LA43 LA44 CO61 is meant for use with: LA23 std. motor LA27 std. motor (cable type A or B) LA29 std. / fast motor LA31 std. / fast motor LA34 std. / fast motor LA40 std. motor LA43 std. motor LA44 std. / fast motor (fast motor not max load) HB20, HB30, HB/HL7X, HB/HD8X, FS3, ACO/ACC/ACK/ACOM/FPP/IRO BA21 BA19

LED indicator CO61 is equipped with a green LED for indication of mains power connected. When the CO61 is connected to mains, the LED is green. Connected only to battery, the LED is off. Acoustic signal functionality: The buzzer will make a warning, when a button on the hand control is pressed, and the battery capacity is low. The buzzer can also be activated by the control box to signal other conditions. This must be specified in the control box software. Dimension drawing:

Mounting of CO61: Mounted with LA40 Drawing No.: 1015W4018

Mounting of CO61: Mounted with LA31 Drawing No.: 1015W4017

Mounting of CO61: Mounted with LA27 Drawing No.: 1015W4016

CO-Link TM Up to 8 channels and 2 x 200 W (or combinations of all CO-control boxes) A CO-Link software makes it possible to link two CO61 control boxes (or combinations of all CO-control boxes) into a system with a primary and secondary control box allowing you to run up to 8 channels with 2 x 200 W. All CO61 benefits and USPs including: 1 control 2 x CO61s 8 channels 2 x 200 W Standard items 2 x 2.2 Ah battery backup 2 x BA21 Mounting brackets: For mounting with LA40 (Article No.: 1015W1002) Drawing No.: 1015W4002 For mounting with LA31 (Article No.: 1015W1004) Drawing No.: 1015W1004

Mounting brackets: For mounting with LA27 (Article No.: 1015W9003) Drawing No: 1015W4003 The adapter 1015W9003 includes a screw that is halfway mounted, thus everything as one part. Screw head torx size: T15 Screw torque: 1.2 ± 0.2 Nm

Mounting bracket (frame flat) - article No. 1015W1001: Mounting bracket (frame flat) w/m4 nuts - article No. 1015W9009: Drawing No.: 1015W4001 Drawing No.: 1015W4009 CO61 - mounted on frame: Release hook Very small built-in dimension: Height: min. 80 mm (lid can be removed) Length: + 20 mm (locking system) Service lid Integrated hinge Removable if needed Easy-mount bracket 3-way cable exit

It is recommended that the CO61 is mounted in a position that allows water to escape. Recommended torque: 0.6 Nm +/-0.1 The bracket can be mounted to the bed frame or any other application by following one of the following mounting procedures: 1) M6 nut to be placed in bracket and fixed with M6 bolt from the rear side. 2) M5 machine screw with flat washer to be fixed through bracket with nut on the rear side. 3) Self-tapping screw to be placed through bracket and onto the frame. Mounting of cables and cable lock: CO61 has a uniquely designed cable lid. The lid also works as an integrated cable lock when closed. 1) Mount cable plugs in control box 2) Close lid until lock snaps into place (see arrows) To allow free access to the cables, the lid has a rest position when completely opened. It is possible to remove the lid by lifting it a few degrees and pulling it away from the housing under tight mounting conditions. See illustrations: 1 Cable management: 2

Copyright LINAK 2018.12. MA M9-02-634-L. Chapter 6.20 Terms of use The user is responsible for determining the suitability of LINAK products for specific application. LINAK takes great care in providing accurate and up-to-date information on its products. However, due to continuous development in order to improve its products, LINAK products are subject to frequent modifications and changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products. While LINAK uses its best efforts to fulfil orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK. All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof, please contact LINAK. FOR MOUNTING INSTRUCTIONS AND GUIDANCE IN USAGE, PLEASE SEE THE RELEVANT USER MANUAL