Datasheet.

Similar documents
Model KB 240 Cooling incubators with compressor technology

Model KB 400 Cooling incubators with compressor technology

Model KMF 720 Constant climate chambers with expanded temperature / humidity range

Model KT 53 Cooling incubators with thermoelectric cooling

Model KBW 720 Growth chambers with light

Model VD 23 Vacuum drying chambers for non-flammable solvents

Model KB 400 Cooling incubators with compressor technology

Model VDL 115 Vacuum drying chambers for flammable solvents

Model KB 400 Cooling incubators with compressor technology

Model KT 53 Cooling incubators with thermoelectric cooling

Refrigerated incubators with forced convection

Environmental simulation chambers MK MKF MKT MKFT

BINDER Inc. North America. Scientific Products Pricelist 2010 Issue 2/10

Drying and heating chambers. Series ED FD FED FP M

Cooled incubators (ST), laboratory refrigerators

Heratherm Compact Microbiological Incubators

Laboratory refrigerators / freezers +4 / -20. X-Cold Series

Isotemp. -86 C Freezers

TMJ-9712 Programmable Temperature & Humidity Chamber

SMART is the right way to do something in the Lab as well.

Drying ovens, incubators, cooled incubators

Blue e+ chillers with the principle

Hand-Held Thermometer Model CTH 6200

Keor HPE UPS THREE-PHASE UPS. from 60 to 200 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

VIBRATION TEST CHAMBERS. Temperature- and Climatic Vibration test chambers. Vibration. test chambers

The PCI Series. Precise power control for complex SCR applications. Phase Angle Fired SCR Power Controls AMPS VAC

09LD/GD. Air-Cooled Condensers/Air-Cooled Fluid Coolers. Nominal cooling capacity kw 09LD/GD 09GD

DC POWER SUPPLIES DNX 110/220 V

DATA LOGGERS Reliable solutions for monitoring your processes

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

Ultralow temperature freezers -86 C. Platilab & Irilab Series

Keor HPE UPS. THREE-PHASE UPS from 60 to 300 kw GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Calibration System for Thermo Hygrometers with Climatic Chamber

DBC 150/650 Series. Druck Dry Block Temperature Calibrators. GE Sensing. Features

Series IPP in four sizes: highly accurate and environmentally friendly, exceptional savings in space and energy

DMT345 and DMT346 Dewpoint Transmitters

Room sensors QFA4160 QFA41 D AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Temperature/Humidity, Vibration Chambers

Specification for temperature sensor calibration setup

FrigoPack FU+ New Generation of Intelligent Refrigeration Inverters

PTF 600. Six Drum Tablet Friability Test Instrument

NEW! Thermo Scientific TLE Series Ultra-Low Freezers

DMT PERFORMING UNDER PRESSURE DMT. Applications. Special features. Description 1/9

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A

HMT330 Series Humidity and Temperature Transmitters for Industrial Applications

! Ranges from -45º to 650ºC. ! Rapid heating, cooling and settling. ! Switch test, ramp, step and preset functions

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

SmartOnline V 10kVA 7kW Online, Double-Conversion UPS, 6U Rack/Tower, Extended Run, Pre-installed SNMP port, RS232, 3 Phase in-single Phase out

Line A. Inverse parallel scrs. Load a FUSION. Line B SCR POWER. O delta CONTROLLERS. Line c. inverse parallel scrs. Load C. FUSION Brochure Rev 3.

Temperature/Humidity Agree vibration chambers

Vibration test chambers. TIRAvibro. Temperature- and Climatic. Vibration test chambers TIRAvibro Vibration test chambers

Cooled incubators ICP /IPP Storage chambers IPS

BEETLE /M-II with Embedded Scale Controller and 2 Displays. Technical Information

IT power distribution Power distribution units (PDU) Basic. Versions available:

the Centric 300 An advanced modular UPS up to 1800kVA/kW

PTB 420 Auto. Fully Automated 4 in 1 Tablet Testing Instrument

MPC Air-Cooled Chillers MPC-FC Free-Cooling Chillers

Digital electropneumatic Positioner for the integrated mounting on process control valves

Precision Hand-held Thermometer

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Distributed by. Keor T UPS THREE-PHASE UPS. from 10 to 120 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

MUFFLE FURNACE CABINET MODEL NO. - ACM-82301

Digital electropneumatic Positioner for the integrated mounting on process control valves

CTC Low Temperature Process Chillers

Comprehensive Modular Genset Controller

Temperature dry-well calibrator Models CTD , CTD

ATV12HU22M3 variable speed drive ATV12-2.2kW - 3hp V - 3ph - with heat sink

Precision pressure indicator 1- or 2-channel version Model CPG2500

MI-4 Melt Flow Indexer

PLT. Breaker-based transfer switch open, closed or soft transition amps. Specification sheet

SmartOnline 10kVA On-Line, Double-Conversion UPS, 6U Rack/Tower, 3-Phase input, 1-Phase output

UPGRADE PROGRAM. V250 Series Pumps vs V301 Series Pumps. Technical Memo

Thermo Scientific Precision Incubators A wide range of incubators to fit your laboratory needs

Filter Fan Unit LIGHT

GP SERIES Packaged Chillers

Micro calibration bath Models CTB , CTB

SmartOnline 240/208/120V 8kVA 5.6kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, 4U Rack/Tower, Split-Phase input, Bypass Switch

SO-LOW LAB FREEZERS TO -85 C

NEW! Thermo Scientific Forma Series Ultra-Low Freezers

IT infrastructure Efficiency-boosting solutions. nextlevel. for data centre

Precision hand-held pressure indicator Model CPH6400

FMP VDC RECTIFIER 42 Amps 2000 Watts

CSPS-6K (Shelf Type) POWER you need POWER SHELF

SmartOnline 208/240V 3kVA 2.4kW Double-Conversion UPS, 3U Rack/Tower, Extended Run, SNMPWEBCARD Option, DB9 Serial

MICROFUSION FEATURES OPTIONS CERTIFICATIONS (PENDING) THREE PHASE SCR POWER CONTROLLERS

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions

Multi-functional precision thermometer CTR3000

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

ProLab 1. ProLab 1000: ph for the professional. ph Meter ProLab 1000: Superior technique in a classy metal body. Precise measurements

Compressed air quality meas. according to ISO 8573 Residual oil content - particles - moisture

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

EBI 25 Wireless Data Logger System

Avanti HP Series Centrifuges Preinstallation

REGENERATIVE LOAD ERI SERIES

REGENERATIVE LOAD ERI SERIES

SmartOnline SV Series 40kVA Medium-Frame Modular Scalable 3-Phase On-Line Double- Conversion 208/120V 50/60 Hz UPS System, 2 Battery Modules

Consolidated Sterilizer Systems

DS October MAXIM 1010 Controller

Transcription:

Industrial Test & Mixing Equipment Bringing Test Innovation to you Datasheet This product datasheet has been provided by John Godrich & SJ Electronics in Partnership with BINDER www.johngodrich.co.uk www.sjelectronics.co.uk

Model MK 53 Dynamic climate chambers for rapid temperature changes The BINDER MK series chamber is suitable for all heat and cold tests between -40 C and 180 C. The MK is a clever alternative to complex individual solutions for cyclical temperature tests. BENEFITS Homogeneous climate conditions thanks to APT.line technology Comprehensive programming and data acquisition Large heated viewing window MAIN FEATURES Model 53 Temperature range: -40 C to 180 C APT.line preheating chamber technology Programmable condensation protection for test material Heated viewing window with LED interior lighting BINDER APT-COM 3 Basic Edition communication software Troubleshooting system with visual and audible alarms Controller with time-segment programming Access port with silicone plug, 80 mm, top Computer interface: RS 422 Display via color LCD monitor Adjustable ramp function Integrated chart recorder Real-time clock 1 stainless steel rack BINDER test confirmation Inner chamber made of stainless steel Pt 100 temperature sensor Thermal insulation using PUR foam CFC-free refrigerant R-404A Cooling with compressor cooling unit Fin evaporator ORDERING INFORMATION Interior volume [cu.ft.] Voltage Option model Version Art.-No. Model MK 53 1.9 230 V 1 ph 50 Hz Standard MK053-230V 9020-0006 Page 1 / 6

TECHNICAL DATA Description MK053-230V 1 Article Number 9020-0006 Performance Data Temperature Temperature range [ C] Temperature variation depending on setpoint [± K] Temperature fluctuation depending on setpoint [± K] Average heating-up rate according to factory standard [K/min] 4.6 Cooling down time from 180 C to -40 C [min] 93 Average cooling down time according to factory standard [K/min] 4.1 Max. heat compensation at 25 C [W] 500 Electrical data Rated Voltage [V] 230 Power frequency [Hz] 50 Nominal power [kw] 2.6 Unit fuse [A] 16 Phase (Nominal voltage) [ph] 1 Outer dimensions Width net [mm] 740-40 180 0.4 2 0.1 0.5 Height net [mm] 1225 Depth net [mm] 740 Wall clearance back [mm] 160 Wall clearance sidewise [mm] 100 Viewing window width [mm] 280 Viewing window height [mm] 280 Doors Unit doors 1 Internal Dimensions Width [mm] 402 Height [mm] 402 Depth [mm] 330 Measures Interior volume [L] 53 Net weight of the unit (empty) [kg] 150 permitted load [kg] 40 Load per rack [kg] 15 Environment-specific data Sound-pressure level [db(a)] 59 Fixtures Number of shelves (std./max.) 1/5 1 All technical data is specified for unloaded units with standard equipment at an ambient temperature of +22 C ±3 C and a power supply voltage fluctuation of ±10 %. The temperature data is determined in accordance to BINDER factory standard following DIN 12880, observing the recommended wall clearances of 10 % of the height, width, and depth of the inner chamber. Technical data refers to 100 % fan speed. All indications are average values, typical for units produced in series. We reserve the right to change technical specifications at any time. Page 2 / 6

CHARTS Heating up rate Cooling down rate Heat compensation chart OPTIONS AND ACCESSORIES Designation Description * Art.-No. left 30 mm 01 8012-1322 50 mm 01 8012-1328 80 mm 01 8012-1334 Access port with silicone plug Analog output, 4 20 ma Calibration certificate, expanded Calibration certificate, temperature Data Logger Kit Data Logger Software right top 30 mm 01 8012-1319 50 mm 01 8012-1325 80 mm 01 8012-1331 80 mm 01 8012-1536 for temperature values (output not adjustable) 8012-0517 for temperature; for extending the measurement in center of chamber to include another test temperature 8012-1124 for temperature, measurement in center of chamber at specified temperature 8012-1143 temperature measurement incl. certificate and 27 measuring points at specified temperature 8012-1602 temperature measurement incl. certificate, 15-18 measuring points at specified temperature 8012-1581 temperature measurement incl. certificate, 9 measuring points at specified temperature 8012-1560 T 220: For continuous temperature logging from -90 C to 220 C. The kit includes 1 data logger, Pt 100 sensor with 2 m extension cable and 1 magnetic fixture for mounting to the BINDER unit LOG ANALYZE software kit, configuration and evaluation software for all BINDER Data Logger Kits (incl. USB data cable) 19 8012-0715 19 8012-0821 * Notes See last page Page 3 / 6

Designation Description * Art.-No. Door lock lockable door handle 8012-0321 Dry-air purge uncontrolled, incl. connection; for preventing condensation 8012-0854 Dry-air purge, connection for the connection to an existing pressurized air network 8012-0939 RS 422 cable set and RS 232 / RS 422 interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0557 Interface converter 230 V, 50/60 Hz option model 8012-0556 RS 422 cable set and RS 422 / Ethernet interface converter for connection to 10-way plug distributor or for connection to a unit 120 V, 60 Hz option model 8012-0405 230 V, 50/60 Hz option model 8012-0380 Interface converter, USB / RS422 RS 422 cable set and RS 422 / USB interface converter for connection to 10-way plug distributor or for connection to a unit (USB-powered converter) 8012-0665 Lockable controller keyboard Lockable controller keyboard with key-operated switch 8012-1345 ph-neutral detergent concentrated, for gentle remove of residual contaminants; 1 kg 1002-0016 Pt 100 temperature sensor additional flexible Pt 100, interior, for displaying the temperature on the unit display 8012-1295 Rack stainless steel 6004-0007 Rack accessories Rack accessories fasteners (1 set of 4) for additional security of racks 8012-0531 RS 422 interface modular plug distributor for 10 RS 422 interfaces 8012-0295 RS 422 interface, cable (15 m) RS 422 interface, cable (50 m) RS 422 connection cable (15 m) between plug distributor and RS 422 interface 5023-0036 RS 422 extension cable (50 m) between interface converter and unit or RS 232 / RS 422 plug distributor 5023-0117 Shelf, perforated stainless steel 6004-0029 APT-COM communications software version 2 to 3, GLP edition 19 9053-0016 version 3, BASIC edition 19 9053-0014 Software version 3, GLP edition 19 9053-0015 version 3, STANDARD edition 19 9053-0013 APT-COM communications software, price: for free version 3, GLP DEMO Edition 19 9053-0008 * Notes See last page SERVICES Designation Description * Art.-No. Installation services Data Logger Kit installation service unit function instructions for operation and programming of the controller 18 DL100600 Installation and set up of unit at operating location, connect to existing connections 13, 18 DL100100 Preventive maintenance Preventive maintenance Executive of equipment inspection according to maintenance plan 14, 18 DL200300 Calibration services Data Logger Kit calibration service including certificate, one measuring point in center of chamber at specified temperature 14, 16, 17, 18 DL300101 Temperature measurement 18 measuring points including certificate, 18 measuring points at specified temperature 14, 16, 17, 18 DL300118 Temperature measurement 27 measuring points including certificate, 27 measuring points at specified temperature 14, 16, 17, 18 DL300127 Temperature measurement 9 measuring points including certificate, 9 measuring points at specified temperature 14, 16, 17, 18 DL300109 * Notes See last page Page 4 / 6

Designation Description * Art.-No. Validation services Execution of IQ/OQ in accordance with qualification folder 15, 18, 20 DL410200 Execution of IQ/OQ/PQ in accordance with customer's requirement, price: on request 15, 18 DL440500 Qualification folder IQ/OQ supporting documents for validation performed by customer, consisting of: IQ/OQ checklists, unit schematics, QM certificate in accordance with ISO 9001 15, 18, 20 8012-0863 Qualification folder IQ/OQ/PQ Warranty service supporting documents for validation performed by customer, in accordance with customer's requirement, extension of Qualification folder IQ/OQ by chapter PQ 15, 18 8012-0951 Extension of the warranty from 2 to 3 years Extension of the warranty from 2 to 5 years beginning with the date of delivery, wearing parts are not included DL011041 beginning with the date of delivery, wearing parts are not included DL011042 * Notes See last page Page 5 / 6

NOTES 01 Condensation may occur in the area around the access port. Access ports may be placed in custom locations for an additional charge. 02 UL mark is not granted when this option is used. 03 Heat resistant only to max. 200 C. 04 Only available on units rated for 230 V. 06 Heating-up time may increase as a result of the lower heat conductivity. 07 The additional heat input may affect the temperature behavior. 09 Not in conjunction with the optional access port, door with window and interior lighting. 10 Not available on 23-liter units. 11 Not available on 23- or 53-liter units. 12 Only available on units rated for 230 V or 400 V. 13 Installation and connections take place at unit location; transport within the company only upon consultation. 14 We recommend a BINDER service contract (see the chapter on BINDER Service) to cover unit inspections, calibrations and validations. 15 OQ according to Yellow Paper = completed factory validation documentation of all OQ checklists. 16 Sensor calibration is performed in an accredited calibration laboratory. 17 Calibration is performed according to the BINDER factory standard. 18 Quoted prices do not include travel costs. Please refer to the chapter on BINDER Service for travel costs for your region. Quoted prices for services performed in Switzerland do not include a country-specific added fee (available on request). 19 For additional accessories, refer to the Process documentation chapter. 20 When ordering IQ/OQ qualification folders and associated IQ/OQ execution on one order, we offer a 15 % discount for both items. When ordering IQ/OQ/PQ qualification folders and associated IQ/OQ/PQ execution on one order, we offer a 15 % discount for the item of the IQ/OQ/PQ folder. Page 6 / 6

Industrial Test & Mixing Equipment Bringing Test Innovation to you Datasheet This product datasheet has been provided by John Godrich & SJ Electronics in Partnership with BINDER www.johngodrich.co.uk www.sjelectronics.co.uk