Features Regulated Converter Description Household, medically and ITE certified Class II installations (without FG) IP68 waterproof encapsulation Long life components, rugged module Energy Efficiency Level VI Cable and connector modifications on request The RACM3-ER/W series comprises reliable and highly efficient power conversion modules in a potted IP68 certified, waterproof encapsulation to fit into flush mount wall installations. All versions are covered by multiple certifications for household, medical and ITE safety standards as well. With a certified operation up to 5m altitude and an ambient temperature range from -2 C up to +7 C, the compact modules are designed to power sanitary, healthcare, smart building, automation, and household applications. Since these modules do not require any external components, they are ready to connect and forget. AC/DC Converter RACM3-ER/W 3 Watt Wired Round Shape Single Output Selection Guide Part Input Output Output Efficiency Number Voltage Range Voltage (1) Current typ. (3) [VAC] [VDC] [A] [%] RACM3-12SER (2) 9-264 12 2.5 88 RACM3-24SER (2) 9-264 24 1.25 89.5 Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/23VAC) and full load at +25 C ambient IP68 R C US TEBA XEBA Model Numbering Output Power Output Voltage RACM3- SER/W Note3: Other connection types on reqeuest Connection (3) Single 2MOPP 25VAC IEC/EN695-1 certified UL695-1 certified ANSI/AAMI ES661-1 certified IEC/EN661-1 certified IEC/EN6335-1 certified IEC/EN61558-1 certified IEC/EN61558-2-16 certified IEC/EN661-1-2 certified EN5524/32 certified EN5514-1 (-2) certified IEC6529 certified www.recom-power.com REV.: 2/218 MED-1
Specifications (measured @ Ta= 25 C, nom. Vin (115/23VAC), full load after warm-up unless otherwise stated) BASIC CHARACTERISTICS RACM3-ER/W Parameter Condition Min. Typ. Max. Internal Input Filter Input Voltage Range 9VAC 23VAC 264VAC Input Current Inrush Current No load Power Consumption 23VAC 23VAC Input Frequency Range 47Hz 63Hz Minimum Load % Power Factor.55 Start-up Time 23VAC 6A 95A 75ms 15ms Rise Time / 23VAC 1ms Hold-up Time 23VAC 15ms 55ms Internal Operating Frequency 1% load at nominal Vin 1kHz Output Ripple and Noise Efficiency vs. Load Efficiency [%] 1 9 8 7 6 5 4 3 2 1 25 RACM3-12SER/W 5 75 85VAC 23VAC 264VAC 1 Efficiency [%] 1 9 8 7 6 5 4 3 2 1 RACM3-24SER/W 25 5 75 85VAC 23VAC 264VAC 1mA 29mA 75mW 75mVp-p 1 Pi type REGULATIONS Parameter Condition Value Output Accuracy ±3.% max. Line Regulation low line to high line ±1.% max. Load Regulation % to 1% load ±1.% max. Transient Response 1% load step change ±3.% max. www.recom-power.com REV.: 2/218 MED-2
Specifications (measured @ Ta= 25 C, nom. Vin (115/23VAC), full load after warm-up unless otherwise stated) RACM3-ER/W Accuracy vs. Load (@ min Vin to max. Vin) +3. RACM3-12SER/W +3. RACM3-24SER/W +2. +2. Deviation [%] +1. -1. -2. Deviation [%] +1. -1. -2. -3. 25 5 75 1-3. 25 5 75 1 PROTECTIONS Parameter Type Value Input Fuse internal (line & neutral) T2A, slow blow Short Circuit Protection (SCP) Over Voltage Protection (OVP) Over Voltage Category (OVC) Over Current Protection (OCP) < 1 minute 12Vout 24Vout 9VAC 264VAC 14% of nominal output current, auto recovery 17% of nominal output current, auto recovery continuous, auto recovery 17VDC, Latch OFF 35VDC, Latch OFF OVCII Hiccup Mode Over Temperature Protection (OTP) 95 C ambient thermal shutdown, auto recovery Class of Equipment Isolation Voltage (3) I/P to O/P tested for 1 minute 4.4kVAC Insulation Grade Leakage Current Class II reinforced 1µA max. Means of Protection 26VAC working voltage 2MOPP Medical Device Classification Note3: For repeat Hi-Pot testing, reduce the time and/or the test voltage Type BF ENVIRONMENTAL Parameter Condition Value Operating Temperature Range Maximum Case Temperature Operating Altitude natural convection.1m/s without derating with derating -2 C to +5 C -2 C to +7 C Operating Humidity non-condensing 95% RH max. IP Rating Pollution Degree MTBF according to MIL-HDBK- 217F, G.B. +25 C +5 C www.recom-power.com REV.: 2/218 MED-3 +85 C 5m IP68 PD2 538 x 1 3 hours 17 x 1 3 hours Design Lifetime E-Cap limitation 13 x 1 3 hours
Specifications (measured @ Ta= 25 C, nom. Vin (115/23VAC), full load after warm-up unless otherwise stated) RACM3-ER/W Derating Graph (@ Chamber and natural convection.1m/s) 1 Output Power [%] 8 6 5 4 2-2 -1 1 2 3 4 5 6 7 Ambient Temperature [ C] 8 9 SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety (CB Scheme) Information Technology Equipment, General Requirements for Safety Medical Electric Equipment, General Requirements for Safety and Essential Performance (CB Scheme) Medical Electric Equipment, General Requirements for Safety and Essential Performance Household and similar electrical appliances - Safety Part 1: General requirements (CB Scheme) Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 11V Safety of transformers, reactors, power supply units and similar products for supply voltages up to 11 V - Part 2-16: Particular requirements and tests for switch mode power supply units T223-255/17 T223-255/17 T223-254/17 T223-254/17 T211-759/17 T211-76/17 IEC695-1:25, 2nd Edition + Am2:213 EN695-1:26 + A2:213 UL695-1, 2nd Edition:214 CAN/CSA C22.2 No. 695-1, 2nd Edition:214 IEC661-1:25, AM1:212 EN661-1:26 + A12:214 CAN/CSA-C22.2 No. 661-1:14, 3rd Edition 214 ANSI/AAMI ES661-1:25 IEC6335-1:21, 5th Edition + A1:213 EN6335-1:212 + A11:214 IEC61558-1:25, 2nd Edition + A1:29 EN61558-1:25 + A1:29 IEC61558-2-16:29, 1st Edition + A1:213 EN61558-2-16:29 + A1:213 Degrees of protection provided by enclosures (IP Code) T211-584/17 IEC6529-1989,2nd-Edition+A1:1999+A2:213 EAC RU-AT.49.9571 TP TC 4/211 TP TC 4/211 RoHs 2 (2+) RoHs 1/1, AM215 EMC Compliance (Medical) Condition Standard / Criterion Medical electrical equipment Part 1-2: Electromagnetic disturbances Requirements and tests EN661-1-2:215 ESD Electrostatic discharge immunity test Air ±2, 4, 8, 15kV; Contact ±8kV IEC61-4-2:28 Radiated, radio-frequency, electromagnetic field immunity test 1V/m (8-27MHz) IEC61-4-3:26 + A2:21 Radiated, radio-frequency, electromagnetic field immunity test (table 9) Fast Transient and Burst Immunity 27V/m (385MHz), 28V/m (45MHz), 9V/m (71, 745, 78MHz), 28V/m 172, 1845, 197, 245MHz), 9V/m (524, 55, 5785MHz) IEC61-4-3:26 + A2:21, Criteria A 28V/m (8-96MHz) IEC61-4-3:26 + A2:21, Criteria B (4) AC Power Port ±2.kV DC Output Port ±1.kV IEC61-4-4:212 Surge Immunity AC Power Port: L-N ±.5, 1.kV IEC61-4-5:25 Note4: Output voltage doesn t meet specified output accuracy www.recom-power.com REV.: 2/218 MED-4
Specifications (measured @ Ta= 25 C, nom. Vin (115/23VAC), full load after warm-up unless otherwise stated) RACM3-ER/W EMC Compliance (Medical) Condition Standard / Criterion Immunity to conducted disturbances, induced by radio-frequency fields AC Power Port 6V IEC61-4-6:213 DC Output Port 6V Power Magnetic Field Immunity 5Hz, 6Hz, 3A/m IEC61-4-8:29 Voltage Dips and Interruptions IEC61-4-11:24 EMC Compliance (Household) Condition Standard / Criterion Electromagnetic compatibility of multimedia equipment Emission Requirements Information technology equipment - Immunity characteristics - Limits and methods of measurement EN5514-1:26 + A1:29 + A2:211 EN5514-2:1997 + A1:21 + A2:28 ESD Electrostatic discharge immunity test Air ±8kV; Contact ±4kV EN61-4-2:1995 + A2:21, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 3V/m (8-1MHz) EN61-4-3:26 + A1:28, Criteria A Fast Transient and Burst Immunity AC Power Port: ±1.kV DC Power Port ±.5kV EN61-4-4:24, Criteria A Surge Immunity AC Power Port: L-N ±.5, 1.kV EN61-4-5:26, Criteria A Immunity to conducted disturbances, induced by radio-frequency fields Voltage Dips and Interruptions AC Power Port 3V DC Power Port 3V EN61-4-6:27, Criteria A EN61-4-11:24 EMC Compliance (Multimedia) Condition Standard / Criterion Information technology equipment - Immunity characteristics - Limits and methods of measurement EN5524:21 ESD Electrostatic discharge immunity test Air ±2, 4, 8kV; Contact ±4kV EN61-4-2:29, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 3V/m (8-1MHz) EN61-4-3:26 + A2:21, Criteria A Fast Transient and Burst Immunity AC Power Port: ±1.kV DC Power Port ±.5kV EN61-4-4:24, Criteria A Surge Immunity AC Power Port: L-N ±.5, 1.kV EN61-4-5:26, Criteria A Immunity to conducted disturbances, induced by radio-frequency fields AC Power Port 3V DC Power Port 3V EN61-4-6:29, Criteria A Power Magnetic Field Immunity 5Hz, 6Hz, 1A/m EN61-4-8:21, Criteria A Voltage Dips and Interruptions Limits of Voltage Fluctuations & Flicker EN61-4-11:24, Criteria A EN61-3-3:213 EMC Compliance (Generic Standards) Condition Standard / Criterion Generic standards Immunity standard for residential, commercial and light-industrial environments EN61-6-1:27 Generic standards Immunity standard for industrial environments Generic standards Emission standard for residential, commercial and light-industrial environments EN61-6-2:25 EN61-6-3:27 + A1:211 DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material Package Dimension (LxWxH) Package Weight Case Potting PCB non-conductive black plastic, (UL94V-) polyurethane, (UL94V-) FR4, (UL94V-) 53. x 378. x 33.5mm 132g max. www.recom-power.com REV.: 2/218 MED-5
Specifications (measured @ Ta= 25 C, nom. Vin (115/23VAC), full load after warm-up unless otherwise stated) RACM3-ER/W Dimension Drawing (mm) FC 2.5 57.1 14. 3.5 N L (blue) (brown Ø 3.2 FC 12.5 V+ (red) FC 12.5 V- (black) embossed logo 18. tc 53. FC 2.5 51. 2. FC 41. 33.5 Wired Connection # Function Wire Color Type 1 VAC in (N) white UL-17, AWG2 2 VAC in (L) white UL-17, AWG2 3 V+ red UL-17, AWG22 4 V- black UL-17, AWG22 tc= case temperature measuring point FC = fixing centers Tolerance: xx.x= ±.5mm xx.xx= ±.25mm Max. tightening torque fixing screws:.3nm 3.5 6. FC 25. Bottom View PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) carton 31. x 22. x 1.mm Packaging Quantity 1pcs Storage Temperature Range -3 C to +8 C Storage Humidtiy non-condensing 95% RH max. The product information and specifications may be subject to changes even without prior written notice.the product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 2/218 MED-6