Installation Requirements for Conformance to Standards

Similar documents
Thermocouple Input Module Product Specifications and Installation Data

PanelView Plus/VersaView CE Terminals and Display Modules

MINI-PS AC/10-15DC/8

Installation Instructions

CompactBlock Guard I/O EtherNet/IP Safety Modules

GE Fanuc Automation. Programmable Control Products. Installation Requirements for Conformance to Standards

MC 11 EB-2 Power supply cabinet with external bus, AC version

SmartBlock I/O Module HE579MIX577/977 Isolated 4/8 Analog Inputs 2/4 Analog Outputs

Output Voltage* (nom.)(adjustable)

Test and Measurements Automated Systems Component Device Testing Semiconductor Processing & Burn-in Aerospace & Satellite Testing

F1000 User's Manual. (Version: V1.01)

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Installation Instructions

ATS01N232RT soft starter for asynchronous motor - ATS01-32 A V

PDD-300 pulsed diode driver

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

CertaDrive. LED indoor drivers. May, Design-in guide - Philips CertaDrive Indoor LED drivers

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

DeviceNet Master (Scanner) HE800DNT450 / HE-DNT450* DeviceNet Communications * HE- denotes plastic case.

PACSystems RX7i IC698CHS009/119

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

Enclosed Power Supplies

24VDC Bipolar Digital In 10-28VDC, 0.5A Sourcing Digital Out 4-20mA Analog In/Out HE800MIX902 / HE-MIX902* * HE- denotes plastic case.

Temperature I/O Module HE800MIX963 / HE-MIX963* * HE- denotes plastic case.

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

ATSU01N209LT soft starter for asynchronous motor - ATSU01-9 A V KW

CAN Fiber Optic Modem

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

4-20 ma Analog Input Module HE800ADC020 / HE800ADC120 HE-ADC020* / HE-ADC120* 12-Bit Resolution * HE-denotes plastic case.

Output Voltage* (nom.)(adjustable)

Features. Applications and Benefits TRC ELECTRONICS, INC

Industrial Serial RS-232 to Fiber Converter. KSC-200 Series. Installation Guide

Safety Standards. Model Number:

Allen-Bradley 1786-RPFRXL

TU531, TU532 Terminal Unit

SmartBlock I/O Module HE579MIX102 Isolated 6 Relay, 12 DC Inputs, 4 Analog Inputs

ATS01N206RT soft starter for asynchronous motor - ATS01-6 A V

Thermocouple / Millivolt Input Module HE800THM000 / HE800THM100 HE-THM000 / HE-THM100* * HE- denotes plastic case.

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Installation Instructions

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Appendix D. EMC Installation Guidelines. Safety Considerations. Ferrite Absorbers and P-Clips. General Product Philosophy

ArmorPoint I/O Field Potential Distributor, Series A

TF501, TF521 Terminal Bases

Redundancy Module QUINT-DIODE/40

PHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

EX-RC1 Remote I/O Adapter

USER MANUAL MODEL 570-R8/570-R R8/580-R Base-T (CAT-5) Surge Protectors

Industrial Power Supplies

Gelo LED Driver 100W, Single output, Constant Voltage RGLD100-24

ATS22D88S6U. ATS22D88S6U soft starter-ats22-control110v-power 208V(25hp)/230V(30hp)/460V(60hp)/575V(75hp) Product data sheet Characteristics.

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Installing the Tracer MP503 Input/Output Module Ordering number: ,

Installation Instructions

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

ATS22D75S6 soft starter-ats22-control 220V-power 230V(18.5kW)/ V(37kW)/500V(45kW)

Thermistor / Current / Voltage Analog Input Module HE800ADC920 / HE-ADC920* 12-Bit Resolution * HE- denotes plastic case.

Gelo LED Driver 100W, Single output RGLD100-24

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

RT4B-110V/12A RECTIFIER

Universal Power Supplies

ATV12P037F1 variable speed drive ATV kW hp V - 1ph - on base plate

GE Fanuc Automation. Programmable Control Products. Installation Requirements for Conformance to Standards

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

NI PXI-1042 Series Power Supply Shuttle

Safety Standards. Model Number: Unit Weight:

STEP-PS/1AC/24DC/1.75

ATS22C11S6U soft starter-ats22-control110vpower208v(30hp)/230v(40hp)/460v(75hp)/575v(100hp)

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

RTD Input Module HE800RTD000 / HE800RTD100 HE-RTD000 / HE-RTD100* * HE- denotes plastic case.

MT-8000 series. MT-8056T/ MT-6056T Installation Instruction. 1.0 Installation and Startup Guide. 2.0 Installation Instructions

ATV12H018M2 variable speed drive ATV kW hp V - 1ph

Solar Combiner Enclosure

Model 7705 Control Module

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

Model Number Structure

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

TRIO-DIODE/12-24DC/2X10/1X20

DC562, digital input/output module,

DI561 Digital Input Module

DC561, digital input/output module,

AO523 Analog Input Module

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

4 x 2 x 0.75 Inches Form factor. 180 Watts with Forced Air Cooling. Approved to EN/IEC Efficiencies up to 92% Standby Power < 0.

ATS22D47S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

EMC Installation Guide

PMC. Model Number: Model Number Input Voltage Range Output Voltage Output Current PMC-12V060W1NA Vac ( Vdc) 12Vdc 5.

ATS22D62Q soft starter-ats22-control 220V-power 230V(15kW)/ V(30kW)

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

ATS22C21S6U softstarter-ats22-control110vpower208v(60hp)/230v(75hp)/460v(150hp)/575v(200hp)

Transcription:

User Manual for Industrial Control Products Installation Requirements for Conformance to Standards Fourth Edition 26 September 2000 MAN0005-04

MAN0005-04 26 SEP 2000 PAGE 3 PREFACE This manual explains how to use the Horner APG Installation Requirements for Conformance to Standards. Copyright (C) 2000 Horner APG, LLC., 640 North Sherman Drive Indianapolis, Indiana 46201. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form by any means, electronic, mechanical, magnetic, optical, chemical, manual or otherwise, without the prior agreement and written permission of Horner APG, LLC. All software described in this document or media is also copyrighted material subject to the terms and conditions of the Horner Software License Agreement. Information in this document is subject to change without notice and does not represent a commitment on the part of Horner APG, LLC. Cscape, CsCAN, and SmartStack are trademarks of Horner APG. For user manual updates, contact Horner APG, Technical Support Division, at (317) 916-4274 or visit our website at www.heapg.com.

MAN0005-04 26 SEP 2000 PAGE 4

MAN0005-04 26 SEP 2000 PAGE 5 REVISIONS TO THIS MANUAL This version (MAN0005-04) of the Installation Requirements for Conformance to Standards contains the following revision. Revised Section 1.7, Item b, General Installation Guidelines for the OCS, RCS, Mini OCS, and SmartStack Modules.

PAGE 6 26 SEP 2000 MAN0005-04

MAN0005-04 26 SEP 2000 PAGE 7 PREFACE This manual describes the installation requirements for Industrial Control products used in environments and situations where compliance to standards or directives from the European Union is necessary. CONTENT OF THIS MANUAL Chapter 1. Installation Guidelines: Describes installation requirements for Horner-APG Industrial Control products. Chapter 2. Safety-Related Guidelines: Describes safety guidelines related to the installation of Industrial Control systems in the European Union. Appendix A: Product Approvals, Standards, and General Specifications: This appendix lists product approvals and standards and provides general specifications to which Horner-APG products must conform when installed in industrial environments. TABLE OF CONTENTS CHAPTER 1: INSTALLATION GUIDELINES...9 1.1 Introduction... 9 1.2 European Union Directives... 9 1.3 EMC Directive... 9 1.4 Grounding the Controls Enclosure...10 1.5 Cable Shield Clamping Assembly...11 1.6 I/O Power Sources...11 1.7 General Installation Guidelines...11 1.8 Safety and Reference Earth Ground...13 1.9 Additional Guidelines for Specific Components...15 1.9.1 Series 90-30 Products...15 1.9.2 Stand-Alone Products...16 1.10 Low Voltage Directive...16 1.11 Machinery Directive...17 CHAPTER 2: SAFETY-RELATED GUIDELINES...19 2.1 Introduction...19 APPENDIX A: PRODUCT AGENCY APPROVALS, STANDARDS, & GENERAL SPECIFICATIONS...23

PAGE 8 26 SEP 2000 MAN0005-04

MAN0005-04 26 SEP 2000 PAGE 9 CHAPTER 1: INSTALLATION GUIDELINES 1.1 Introduction The installation manuals shipped with your Industrial Control equipment provide detailed information regarding the equipment's proper installation, startup, and use. This manual describes the standards and procedures that Horner-APG (HE-APG) Industrial Control products must conform to for installation in environments which must meet the more stringent installation requirements of the European Union. 1.2 European Union Directives The European Union (EU) has implemented directives to harmonize product safety standards within the EU. Compliance with the EU directives is required for products installed within the EU. Products installed within the EU must comply with each applicable directive. Two EU directives apply directly to HE-APG Industrial Control products: a. The EMC Directive (89/336/EEC, 92/31/EEC, 93/68/EEC) deals with electromagnetic emissions and immunity. b. The Low Voltage Directive (73/23/EEC, 93/68/EEC) deals with electrical safety. HE-APG Industrial Control products will be CE-marked to indicate compliance with the EMC Directive. In addition, HE-APG will issue Declarations of Conformity that specify the directive(s) and the catalog numbers of the products covered. Programmable Control products must be installed using the instructions in the Installation Manuals and in the applicable sections of this manual. Manufacturers of machines to be installed within the EU must also comply with the following directive: The Machinery Directive (89/392/EEC [Machinery Directive], 91/368/EEC, 93/44/EEC, 93/68/EEC, [Global Directive]) deals with machine safety. 1.3 EMC Directive The EMC Directive is concerned with the immunity of electrical equipment to a variety of interference sources and the emissions from electrical equipment, which can interfere with the operation of other equipment. The EMC Directive applies to complete installations, and since HE-APG products are included in the installation, HE-APG is supporting the EMC Directive by testing and CE marking a subset of our equipment. EMC Directive 89/336/EEC 92/31EEC 93/EEC HE-APG Industrial Products will Comply Technical Construction file Specialized Test Plan for Horner APG products HE-APG Declaration of Conformity Figure 1-1 HE-APG s Path to Comply with the EMC Directive

PAGE 10 26 SEP 2000 MAN0005-04 The following section specifies additional installation and application practices necessary to meet the EMC Directive for wiring that leaves the control cabinet and travels through a factory environment. Wiring that leaves the cabinet may be exposed to interference sources corresponding to the standards and levels specified in Appendix A. The installation practices found in the individual product installation manuals must also be followed. 1.4 Grounding the Controls Enclosure Locally applicable grounding safety regulations and machinery directives shall be followed for providing a protective ground to earth. In addition, the following safety guidelines should be followed: 1. Ground conductors shall be as short and as large in size as possible. The conductors must always be large enough to carry the maximum short circuit current of the path being considered. Braided straps or ground cables (typically green insulation with a yellow tracer - AWG #12 (3.3 mm2) or larger) can be used to minimize resistance. 2. The PLC equipment, other control equipment, and the machine shall be interconnected to maintain a common earth ground reference (sometimes referred to as the machine chassis ground). 3. Ground conductors shall be connected in a tree fashion with branches routed to a central earth ground point. This ensures that no ground conductor carries current from any other branch. This method is shown in the following figure. Programming Device PLC Cabinet Motor Drives and other Electrical Control Equipment Machinery Earth Ground Central Ground Note: Signal Point and Power are not shown. Figure 1-2 Recommended System Grounding

MAN0005-04 26 SEP 2000 PAGE 11 The EMC ground deals with the ability of the system to conduct interference energy transformed into a high frequency and high amplitude current to the machine chassis without causing secondary interference. The EMC ground requires the following: 1. The EMC ground must be a low impedance, low inductance path to the machine chassis ground. 2. The baseplate on which the product is mounted should be connected to the machine chassis ground by a wire with a 10:1 length-to-width ratio to provide a high frequency path. (A typical installation simulated for EMC testing used a 2m 12 AWG wire.) 1.5 Cable Shield Clamping Assembly A cable shield clamping assembly (IC697ACC736) is available from HE-APG to provide higher EMC immunity for shielded cables in severe industrial environments. This assembly provides a high frequency ground for shielded cables. (A set of 12 additional cable clamps can be ordered - IC697ACC737.) Refer to the HE-APG manual for detailed installation and usage information about the assembly. 1.6 I/O Power Sources All power sources needed by the PLC equipment for I/O (discrete and analog) must be appropriately conditioned to not exceed the I/O EMC levels specified in Appendix A for EN61000-4-4:1995 and EN61000-4-5:1995. 1.7 General Installation Guidelines In order to meet CISPR (EN 55011) Group 1, Class A Radiated Emissions levels, all components in the PLC system require the following: a. Series 90-30, Series 90-70, and OIU Products 1. It is recommended that all components be mounted in a metal enclosure (or the equivalent) with wiring external to the enclosure routed in metal conduit or the equivalent. All surfaces of the enclosure must be adequately grounded to adjacent surfaces to provide electrical conductivity. 2. The metal conduit (flexible conduit is acceptable) for all wiring external to the cabinet must be mounted to the enclosure using standard procedures and hardware to ensure electrical conductivity between the enclosure and the conduit. 3. An external EMI filter must be wired to the AC Main for the PLC and our OIU's. Sprague Electric Part Number 259A9098P3 (available from HE-APG) or any other EMI filter, which provides equivalent performance. (Series 90-30 and Series 90-70) 4. An external ground wire (16 AWG (1.32 mm2), 6" (15.24 cm) maximum length) must be wired from the power supply safety ground wire terminal to the metal enclosure. 5. On AC Main Ports connected to PLCs and OIUs, MOVs shall be connected Line to Line and Line to Ground. (Series 90-30 and Series 90-70) 6. All cables, I/O, Analog, and Communications must use shielded cable with a minimum of overall foil. Communications cables for RS-485 based OIU shall have overall foil and braid shield.

PAGE 12 26 SEP 2000 MAN0005-04 b. Operator Control Station (OCS) / Remote Control Station (RCS) / SmartStack Modules / Mini OCS WARNING To provide maximum noise immunity and to ensure minimum EMI radiation, the V- signal (DC power return) shall be connected to Earth Ground at the power supply. The user must ensure that the power supply selected is compatible with this method of grounding. 1. When a single power supply is used to power both the controller and I/O, and the I/O is used to switch electrically noisy devices ( i.e., solenoids, motors, relays), it is highly recommended to use appropriate noise suppression devices. In general, using separate power supplies is recommended (although not always required) for several reasons. a. Provides optimal noise immunity for the controller; b. Provides optimal analog accuracy; c. Reduces grounding issues when using isolated I/O; d. Reduces voltage sags on the controller power. 2. All components must be mounted in a metal enclosure (or the equivalent) with wiring external to the enclosure routed in metal conduit or the equivalent. All surfaces of the enclosure must be adequately grounded to adjacent surfaces to provide electrical conductivity. 3. The metal conduit (flexible conduit is acceptable) for all wiring external to the cabinet must be mounted to the enclosure using standard procedures and hardware to ensure electrical conductivity between the enclosure and the conduit. 4. An external EMI filter must be wired to the AC Main for the PLC and our products. Sprague Electric Part Number 259A9098P3 (available from HE-APG) or any other EMI filter, which provides equivalent performance. 5. On AC Main Ports connected to PLCs and OIUs, MOVs shall be connected Line to Line and Line to Ground. 6. All cables, I/O, Analog, and Communications must use shielded cable with a minimum of overall foil. Communications cables for RS-485 based OIU shall have overall foil and braid shield. 7. The OCS analog input, output and communication signals need to use Belden Wire # 3084A (thin) or #3082A (thick) or equivalent.

MAN0005-04 26 SEP 2000 PAGE 13 1.8 Safety and Reference Earth Ground a. Series 90-30 Products (See Figure 1-3.) Series 90-30 PLC System Power Supply Ground Metal Baseplate Earth Ground Figure 1-3 Series 90-30 Grounding The metal back of the baseplate is ground, when properly installed. Safety and Reference ground connections should be made from one of the mounting tabs to earth ground using a minimum AWG #12 (3.3 mm2) wire and a ring terminal. Use of a nut and star washer for each wire on the ground connection lug is recommended to ensure adequate grounding. WARNING The baseplate must be grounded to minimize electrical shock hazard, which can result in severe personal injury. All baseplates grouped together in a PLC system must have a common ground connection. This is especially important for baseplates that are not mounted in the same control cabinet. The best way to provide proper ground connections is to ensure that the PLC baseplate metal frame is directly connected to the control panel in which the baseplate or baseplates are mounted. This can be accomplished by connecting a ground strap from one of the ground lugs on either side of the baseplate to the control panel or cabinet following applicable electrical safety codes.

PAGE 14 26 SEP 2000 MAN0005-04 b. Operator Control Station (OCS) / Remote Control Station (RCS) / Mini OCS Figures 1-4 through 1-6. depict grounding for the OCS, RCS, and Mini OCS devices. For additional grounding information, refer to installation chapter in the Control Station Hardware User Manual for the OCS, RCS, and SmartStack Modules. Refer to the installation chapter for the Mini OCS in the Mini OCS Control Station Hardware User Manual. WARNING To provide maximum noise immunity and to ensure minimum EMI radiation, the V- signal (DC power return) shall be connected to Earth Ground at the power supply. The user must ensure that the power supply selected is compatible with this method of grounding. OCS Figure 1-4 Grounding OCS100 or OCS200 (Shown with four SmartStack Modules) RCS Figure 1-5 Grounding RCS210 (Shown with four SmartStack Modules)

MAN0005-04 26 SEP 2000 PAGE 15 Note: Consider the length of the Ground Screw extension when determining clearances. Ground strap Figure 1-6 Grounding Mini OCS Modules 1.9 Additional Guidelines for Specific Components The guidelines specified in this section must be followed in addition to the guidelines found in the general installation guidelines for the product line. 1.9.1 Series 90-30 Products a. External clamp-on ferrites need to be added to the cables of the following devices when the installed cable length exceeds 3m: HE693ASC900 HE693THM166 HE693THM66X HE693RTD60X HE693RTD66X b. The following unit can not have cables exceeding 30m: HE693STPXX1 HE693ASC900

PAGE 16 26 SEP 2000 MAN0005-04 1.9.2 Stand-Alone Products These 24VDC HE-APG Products require a dedicated 24VDC supply mounted within the enclosure: HE693OIUXXX-24 HE693OIU177 HE485ISO485 HE693OIU2X7 HE693OIU368 External clamp-on ferrites need to be added to the cables of the following devices when the installed cable length exceeds 30m: IC660ELB92X HE693OIU157-24 HE693OIU177 HE693SNP232 HE693OIU327 HE693OIU357 The following units cannot have cables exceeding 3m and those cables can not exit the enclosure: HE693OIU157 HE693WCIXXX RS-232 ports on all HE-APG OIUs (except OIU368) The following units can not have cables exceeding 30m: HE693OIU368 HE693OIU057-24 HE693OIU057 1.10 Low Voltage Directive The Low Voltage Directive applies to products operating above 50 VAC or 75 VDC. The emphasis of the Low Voltage Directive is on safety. Low Voltage Directive 73/23/EEC 93/68/EEC HE-APG Industrial Products will Comply EN60204-1 Safety of Machinery Electrical Equipment of Machines IEC 1131-2 Programmable Controllers (Safety Requirements) HE-APG Declaration of Conformity Figure 1-7 HE-APG s Path to Comply with Low Voltage Directive

MAN0005-04 26 SEP 2000 PAGE 17 1.11 Machinery Directive The Machinery Directive focuses on the safe operation of the entire machine and is the responsibility of the machine manufacturer. Machinery Directive 89/392/EEC 91/368/EEC 93/68/EEC Machine Manufacturer s Responsibility to Comply EN292-1,-2 Safety of Machinery EN60204-1 Electrical Equipment of Industrial Machine IEC 1131-2 Programmable Controllers (Safety Requirements) HE-APG Complies Figure 1-8 HE-APG s Path for Supporting Machine Manufacturer s Compliance with the Machinery Directive HE-APG PLC products listed comply with the safety requirements of IEC 1131-2 (Programmable Controllers). When applied in accordance with EN60204-1 (Electrical Equipment of Industrial machines) and HE-APG installation instructions, HE-APG s PLC products allow a machine manufacturer to comply with the electrical safety requirements of the Machinery Directive. Other requirements of the Machinery Directive involving items such as displays, languages, instructions, Emergency Stop functions, machine operation, protective guards and interlocks are the responsibility of the machine manufacturer. The specific requirements of EN60204-1, IEC 1131-2, and HE-APG installation instructions are as follows: 1. Compliance with EN292-1 and EN292-2 (Safety of Machinery) as well as EN60204/IEC204 (Electrical Equipment of Industrial Machines) must be observed during the design phase. 2. The PLC products must be packaged within a metal, IP54 or higher degree of protection enclosure. 3. Negative logic input and output modules cannot be used. (Exception: With safety agency approval, these devices may be used in safety system "H" configurations.) 4. The PLC power supply must be supplied through an IEC-rated isolation transformer. 5. Power supply to the PLC must be controlled to ensure that it does not exceed over-voltage category II per EN60204-1 (IEC 240). 6. Cable shielding and grounding are the responsibility of the machine builder. HE-APG s installation instructions and guidelines must be followed. 7. Installation, operation, and maintenance instructions in the language of the user s country are the responsibility of the machine builder.

PAGE 18 26 SEP 2000 MAN0005-04 NOTES

MAN0005-04 26 SEP 2000 PAGE 19 CHAPTER 2: SAFETY-RELATED GUIDELINES Safety Related Guidelines for Users of HE-APG PLC Products to be Installed in the European Union 2.1 Introduction This chapter provides a description of safety-related guidelines for installation of PLC systems. It is assumed that personnel who install, operate, and maintain automation systems, which include HE-APG products are trained and qualified to perform those functions. This chapter specifically provides safetyrelated guidelines for products to be installed in the European Union. a. General HE-APG product manuals provide information required for the intended use of HE-APG products. The product manuals are written for technically qualified personnel such as engineers, programmers or maintenance specialists who have been specifically trained and are experienced in the field of automation control. Such personnel must possess the knowledge to correctly interpret and apply the safety guidelines provided in HE-APG product manuals. Should you require further information or face special problems that have not been dealt with in sufficient detail in the product manuals, please contact your local HE-APG sales or service office or an HE-APG authorized distributor. b. Qualified Personnel Only qualified personnel shall be allowed to specify, apply, install,operate, maintain or perform any other function related to the products described in the product manuals. Examples of such qualified persons are defined as follows: 1. System application and design engineers who are familiar with the safety concepts of automation equipment. 2. Installation, startup, and service personnel who are trained to install and maintain such automation equipment. 3. Operating personnel trained to operate automation equipment and trained on the specific safety issues and requirements of the particular equipment. c. Proper Usage: The equipment/system or the system components can only be used as described in the product manuals. HE-APG PLC products have been developed, manufactured, and tested, and the documentation has been compiled in keeping with the relevant safety standards. Handling instructions and safety guidelines described for planning, installation, proper operation and maintenance must be followed to ensure safe application and use of the products.

PAGE 20 26 SEP 2000 MAN0005-04 d. Guidelines for the Application Planning and Installation of the Product: HE-APG PLC products generally form a part of larger systems or installations. These guidelines are intended to help integrate HE-APG PLC products into systems and installations without constituting a source of danger. The following precautions must be followed: 1. Compliance with EN292-1 and EN292-2 (Safety of Machinery) as well as EN60204/IEC204 (Electrical Equipment of Industrial Machines) must be observed during the design phase. 2. Opening the housing or the protective cover exposes certain parts of this equipment/system, which could have a dangerously high voltage level. 3. Only qualified personnel should be allowed access to this equipment/system. 4. These persons must be knowledgeable of potential sources of danger and maintenance measures as set out in the product manuals. 5. Strictly adhere to applicable safety and accident prevention rules and regulations. 6. A suitable isolating switch or fuses must be provided in the building wiring system. The equipment must be connected to a protective ground (PE) conductor. 7. For equipment or systems with a fixed connecting cable but no isolating switch which disconnects all poles, a power socket with the grounding pin must be installed. 8. Before switching on the equipment, make sure that the voltage range setting on the equipment corresponds to the local power system voltage. 9. Fluctuations or deviations of the new power supply voltage from the rated value must not exceed the tolerances specified in the technical specifications. Otherwise, functional failures or dangerous conditions can occur in the electronic modules/equipment. 10. Emergency tripping devices in accordance with EN60204/IEC204 must be effective in all operating modes of the automation equipment. Resetting the emergency off device must not result in any uncontrolled or undefined restart of the equipment. 11. Automation equipment and its operating elements must be installed in such a manner as to prevent unintentional operation. 12. Suitable measurements must be taken to make sure that operating sequences interrupted by a voltage dip or power supply failure resume proper operation when the power supply is restored. Care must be taken to ensure that dangerous operating conditions do not occur even momentarily. If necessary, the equipment must be forced into the "emergency off" state. 13. Negative logic Input and Output Modules cannot be used. (Exception: With safety agency approval (such as TÜV on GMR Systems), these devices may be used in safety system "H" configurations).

MAN0005-04 26 SEP 2000 PAGE 21 14. Cable shielding and grounding are the responsibility of the machine builder. HE-APG's installation instructions and guidelines must be followed. 15. Install the power supply and signal cables in such a manner as to prevent inductive and capacitive interference voltages from affecting the automation functions. 16. Measures must be taken when interfacing the inputs and outputs of the automation equipment to prevent an undefined state from being assumed in the case of a wire break in the signal lines.

PAGE 22 26 SEP 2000 MAN0005-04 NOTES

MAN0005-04 26 SEP 2000 PAGE 23 APPENDIX A: PRODUCT AGENCY APPROVALS, STANDARDS, & GENERAL SPECIFICATIONS 1 Introduction This information applies to HE-APG products. Table 1 Agency Approvals Overview 1 Standard/Directive Approval/ Symbol Comments Industrial Control Equipment Certification by certified UL508 [Safety] test facility Process Control Equipment Certification by certified C-UL [Safety] test facility Hazardous Locations [Safety] Class I, Div II, A, B, C, D UL1604 with C-UL Certification by certified test facility European EMC Directive CE Mark Self-certification in accordance with applicable CE directives Table 2 Standards Overview 2,4 Parameters Approval/ Symbol Conditions Operating Temperature 3 0 C to 60 C Storage Temperature -40 C to +85 C Humidity 5% to 95%, non-condensing Enclosure Protection IEC529 Steel cabinet per IP54: Protection from dust and splashing water EMC Emissions EN50081-2: 1995 Generic Emissions for Heavy Industrial Environment Radiated, Conducted CISPR11 EN55022 Class A

PAGE 24 26 SEP 2000 MAN0005-04 Table 3 EMC Immunity (Applies to CE Marked Modules) EMC Immunity EN50082-2: 1995 Generic Immunity for Heavy Industrial Environment Test Standard Conditions Electrostatic Discharge EN61000-4-2.1995 8KV Air Discharge, 4KV Contact Discharge Radiated RF ENV50140:1995 10Vrms/m, 80Mhz to 1000Mhz, modulated Fast Transient Burst EN61000-4-4:1995 2KV: power supplies, 1KV: I/O, communications Surge Withstand EN61000-4-5:1995 2KV power, 1KV to shields Conducted RF ENV50141:1995 10V, 150Khz to 80Mhz injection for communication cables >30m Damped Oscillator Wave EN61000-4-12 2.5Kv Comm. mode 2.5Kv Diff. mode Table 4 Power Supply Test Standard Condition Input Dips, Variations EN61000-4-11:1995 During Operation: Dip to 30% and 100%, Variation for AC ±10%, Variation of DC ±20%