We reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.

Similar documents
ACExC 01.2 Modbus TCP/IP

AC 01.2 Foundation Fieldbus

AC 01.2 Foundation Fieldbus

Actuator controls. AUMATIC AC 01.1 ACExC 01.1 DeviceNet. Operation instructions. Zertifikat-Registrier-Nr /

SRQ24A. Technical data. Safety notes. Rotary actuator for ball valves Torque 16Nm Nominal voltage AC/DC 24V Control: Open-close Running time 9s

ELECTRIC ACTUATORS Compact devices for the automation of globe valves, ball valves and butterfl y valves

9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)

Functional data Factory settings Variable Setting Torque Inhibiting torque

Accessories / 7XV5662

Actuator controls AC 01.2/ACExC 01.2

Actuator controls. AUMA MATIC AM 01.1/ AM 02.1 AMExB 01.1/ AMExC 01.1 Profibus DP. Operation instructions

Overview of types. Technical data

LME620-AI/-AN (Contrac) Electrical Linear Actuator

Actuator controls AUMATIC AC 01.2

PRODUCT INFORMATION. AUMA Actuators, Inc. Pittsburgh PA USA. Triple Play Digital Communications Board DeviceNet / Modbus CDN455

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

SIMOCODE 3UF Motor Management and Control Devices

Technical Information Fieldgate SFG500

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

PRODUCT INFORMATION. DeviceNet Triple Play Digital Communications Board. SA Actuator with AUMA Matic Motor Controls

Power consumption In operation At rest For wire sizing

Zelio Control-modular measurement and control relays 1

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

B. AVM321S/AVM322S: 1000N Actuator with analog SUT positioner

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

ATV32HU11M2437 variable speed drive ATV32-1.1kW 200V - 1P - Bluetooth built-in - w heat sink

Contact protection relay

ELECTRIC ACTUATORS Innovations for SGC part-turn actuators and SVC valve actuators

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

See «Overview of types» 90 s / 60 mm 150 s / 100 mm Manuelle Auslösung der Adaption durch Drücken der Taste «Adaption» oder mit dem PC-Tool

Actuator controls AUMATIC ACExC 01.2 Modbus RTU

Operating instructions. Switching amplifier DN0210 DN / / 2015

ATV320U04N4C variable speed drive ATV kW V - 3 phase - compact

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

All data in this brochure are given for information only and are subject to change without notice. INTELLI+ Intelligent control

Part-turn actuators SQ 05.2 SQ 14.2/SQR 05.2 SQR 14.2 Control unit: electronic (MWG) with actuator controls AUMATIC AC 01.

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

AS-i Safety Relay Output Module with Diagnostic Slave

Flow Measurement SITRANS F C

ATV320U07M2C variable speed drive ATV kW V - 1 phase - compact

Operating instructions. Speed monitor D / / 2014

Electric Actuators Type 5824 (without fail-safe action) Type 5825 (with fail-safe action)

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

SIRIUS Motor Management and Control Devices

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

Series 3730 Type Electropneumatic Positioner

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

Electric Actuated Ball Valves 2-way Stainless Steel, Full Port 1/4 to 2 NPT

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency. Draft

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Actuator controls. AUMATIC AC 01.1/ACExC Operation and setting. Control: Profibus DP. Parallel

MIC-2 Multi-instrument DATA SHEET

Signal Doublers. VariTrans A 20300

Compact universal controllers

JUMO Quantum PID100/PID200/PID300

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D15N4B variable speed drive ATV320-15kW V - 3 phase - book

ATV320D11N4B variable speed drive ATV320-11kW V - 3 phase - book

Motors Automation Energy Transmission & Distribution Coatings. Profibus DP SRW 01. User s Manual

Industrial Electric Actuators AC and DC Voltages Nm/ inch lbs

PROFIBUS-PA Positioner Type 3785

Power consumption In operation At rest For wire sizing. Torque Inhibiting torque. 150 s / C Sound power level Motor

SK CU4-PBR-C Part number:

ATV32HD11N4 variable speed drive ATV32-11 kw V - 3 phase - with heat sink

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink

Part-turn actuators SQ 05.2 SQ 14.2/SQR 05.2 SQR 14.2 Control unit: electromechanic with actuator controls AUMATIC AC 01.

Digital electropneumatic positioner

Magnetic and Hydraulic-Magnetic Circuit Breaker

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

Multi-turn actuators SA(R) SA(R) 16.1 with AUMATIC AC 01.1

Digital electropneumatic positioner

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

ATV32HU75N4 variable speed drive ATV kw V - 3 phase - with heat sink

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

ATV930D22M3 variable speed drive - ATV930-22kW - 200/240V- with braking unit - IP21

Available with actuator function: POWER OPEN - POWER CLOSE FAILSAFE MODULATING FAILSAFE MODULATING. Overview

ATV32H055N4 variable speed drive ATV kw V - 3 phase - with heat sink

Communications & Networking

CSI 6300 SIS Overview

Technical data. Dimensions: see page 116. ): 4 kv Rated insulation voltage (U i Over-voltage category: Power supply. Rated operating voltage (Un):

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

SMART RELAY SRW 01 V4.0X

ATV32HU40N4 variable speed drive ATV32-4 kw V - 3 phase - with heat sink

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

ATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

ATV320U30N4B variable speed drive ATV320-3kW V - 3 phase - book

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

Products no longer available

General information. Display. Supply voltage. Input current. Encoder supply. Output current

T EN TROVIS Electropneumatic Positioner

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

E.CK Centronik Control and Indication Specification CENTRONIK FUNCTION AND PROTECTION DETAILS. Local Control. Local Indication.

Transcription:

General information AC 01.2 actuator controls for controlling multi-turn actuators of the SA/SAR.2 type range and part-turn actuators of the SQ/SQR type range with interface. Features and functions Power supply Standard voltages AC: 3-phase AC current 1-phase AC current Volt 208 220 230 240 440 460 480 575 600 Volt 110, 115, 120 220, 230, 240 Hz 60 60 60 60 60 60 60 60 60 Hz 60 50/60 External supply of the electronics (option) Current consumption Special voltages AC: 3-phase AC current 1-phase AC current Volt 220 230 240 380 400 415 500 525 575 600 660 690 Volt 208 Hz 50 50 50 50 50 50 50 50 50 60 50 50 Hz 60 Permissible variation of mains voltage: ±10 % Permissible variation of mains voltage: ±30 % (option) Permissible variation of mains frequency: ±5 % Special voltages DC: (on request) DC current Voltages Volt 24 48 60 110 125 220 250 Permissible voltage deviation: (on request) 24 V DC: + 20 %/ 15 %, or 115 V AC: + 20 %/ 15 %, Current consumption: Basic version approx. 250 ma, with options up to 500 ma Current consumption for 115 V AC version: Approx. 160 ma External power supply must have reinforced insulation against mains voltage in accordance with IEC 61010-1 and may only be supplied by a circuit limited to 150 VA in accordance with IEC 61010-1. Current consumption of controls depending on mains voltage: For permissible variation of mains voltage of ±10 %: 100 to 120 V AC = max. 740 ma 208 to 240 V AC = max. 400 ma 380 to 500 V AC = max. 250 ma 515 to 690 V AC = max. 200 ma For permissible variation of mains voltage of ±30 %: 100 to 120 V AC = max. 1,200 ma 208 to 240 V AC = max. 750 ma 380 to 500 V AC = max. 400 ma 515 to 690 V AC = max. 400 ma Overvoltage category Category III according to IEC 60364-4-443 Rated power Actuator controls are designed for rated motor power (refer to Electrical data Multi-turn/Part-turn actuators) Switchgear Standard: Reversing contactors (mechanically and electrically interlocked) for AUMA power classes A1/A2 Options: Reversing contactors (mechanically and electrically interlocked) for AUMA power class A3 Thyristor unit for mains voltage up to 600 V AC for AUMA power classes B1, B2 or up to 500 V AC for AUMA power class B3 (recommended for modulating actuators) The reversing contactors are designed for a lifetime of 2 million starts. For applications requiring a high number of starts, we recommend the use of thyristor units. For the assignment of AUMA power classes, please refer to Electrical data Multi-turn /Part-turn actuators. Control and feedback signals Via interface Y004.679/065/us Issue 1.15 Page 1/6

Fieldbus interface with additional input signals (options) Control voltage and current consumption of optional, digital additional inputs Status signals Fieldbus interface with additional output signals (options) 2 free analog inputs (0/4 20 ma), 4 free digital inputs - Signal transmission is made via fieldbus interface Inputs OPEN, STOP, CLOSE, EMERGENCY, I/O interface, MODE (via opto-isolator thereof OPEN, STOP, CLOSE, MODE with one common and EMERGENCY, I/O interface respectively without common) - Control inputs: OPEN, STOP, CLOSE, EMERGENCY - I/O interface: Selection of control type (fieldbus or additional input signals) - MODE: Selection between open-close duty (OPEN, STOP, CLOSE) or modulating duty (0/4 20 ma position setpoint) - Additionally 1 analog input (0/4 20 ma for position setpoint) Inputs OPEN, STOP, CLOSE, EMERGENCY, I/O interface, MODE (via opto-isolator thereof OPEN, STOP, CLOSE, MODE with one common and EMERGENCY, I/O interface respectively without common) - Control inputs: OPEN, STOP, CLOSE, EMERGENCY - I/O interface: Selection of control type (fieldbus or additional input signals) - MODE: Selection between open-close duty (OPEN, STOP, CLOSE) or modulating duty (0/4 20 ma position setpoint) - Additionally 1 analog input (0/4 20 ma) for setpoint position and 1 analog input (0/4 20 ma) for actual process value Standard: 24 V DC, current consumption: approx. 10 ma per input Options: 48 V DC, current consumption: approx. 7 ma per input 60 V DC, current consumption: approx. 9 ma per input 115 V DC, current consumption: approx. 15 ma per input 100 120 V AC, current consumption : approx. 15 ma per input All input signals must be supplied with the same potential. Via interface Additional, binary output signals (only available in combination with additional input signals (option)) - 5 potential-free NO contacts with one common, max. 250 V AC, 1 A (resistive load) Default configuration: End position CLOSED, end position OPEN, selector switch REMOTE, torque fault CLOSE, torque fault OPEN - 1 potential-free change-over contact, max. 250 V AC, 5 A (resistive load) Default configuration: Collective fault signal (torque fault, phase failure, motor protection tripped) - 5 potential-free change-over contacts with one common, max. 250 V AC, 1 A (resistive load) - 1 potential-free change-over contact, max. 250 V AC, 5 A (resistive load) - 6 potential-free change-over contacts without one common, max. 250 V AC, 5 A (resistive load) - 4 self-latching potential-free NO contacts with one common, max. 250 V AC, 1 A (resistive load), 1 potential-free NO contact, max. 250 V AC, 1 A (resistive load), 1 potential-free change-over contact, max. 250 V AC, 5 A (resistive load) - 4 self-latching potential-free NO contacts, max. 250 V AC, 1 A (resistive load), 2 potential-free NO contacts, max. 250 V AC, 1 A (resistive load), All binary output signals must be supplied with the same potential. Analog output signal for position feedback - Galvanically isolated position feedback 0/4 20 ma (load max. 500 Ω) Voltage output Standard: Auxiliary voltage 24 V DC: max. 100 ma for supply of control inputs, galvanically isolated from internal voltage supply. Option: Auxiliary voltage 115 V AC: max. 30 ma for supply of control inputs, galvanically isolated from internal voltage supply Auxiliary voltage 115 V AC: max. 150 ma for supply of control inputs, galvanically isolated from internal voltage supply. Auxiliary voltage 115 V AC: max. 100 VA for supply of control inputs, galvanically isolated from internal voltage supply. -V1 (option) Access to parameters, the electronic name plate and the operating and diagnostic data with acyclic write/read services Y004.679/065/us Issue 1.15 Page 2/6

-V2 (option) Redundancy (option) FO cable connection (option) Redundancy behavior according to -V2 specification no. 2.212 (Primary and Backup with RedCom) Synchronization of time between AC 01.2 and Profibus master with subsequent time stamp of the most important events such as faults, end position and torque signals from the AC 01.2 Requires -V2 (option) Redundant line topology with universal redundancy behavior according to AUMA redundancy I or II Redundant line topology and redundancy behavior according to -V2 specification no. 2.212 (Primary and Backup with RedCom) Connector types: ST or SC connector FO cables - Multi-mode: 62.5(50)/125 μm, range approx. 2.5 km (max. 2.0 db/km) - Single-mode: 9/125 μm, range approx. 15 km (max. 0.4 db/km) Topologies: Line, star and redundant loop (with single-channel Profibus interface) Baud rate: up to 1.5 Mbit/s Optical budget: - Multi-mode: 13 db - Single-mode: 17 db Wave length: 1,310 nm FO coupler by EKS required at DCS, reference addresses: AUMA or www.eks-engel.com Local controls Standard: Selector switch: LOCAL - OFF - REMOTE (lockable in all three positions) Bluetooth communication interface Option: Application functions Standard: Push buttons: OPEN, STOP, CLOSE, RESET - Local STOP The actuator can be stopped via push button STOP of local controls if the selector switch is in position REMOTE (not activated when leaving the factory). 6 indication lights: - End position and running indication CLOSED (green), torque fault CLOSE (blue), motor protection tripped (yellow), torque fault OPEN (violet), end position and running indication OPEN (red), Bluetooth (blue) Large graphic LD display, with 200 x 100 pixels: illuminated Display language: English (can be programmed to display other languages upon request) 6 indication lights: - End position and running indication CLOSED (yellow), torque fault CLOSE (red), motor protection tripped (red), torque fault OPEN (red), end position and running indication OPEN (green), Bluetooth (blue) Bluetooth class II chip, version 2.1: with a range up to 10 m in industrial environments, supports the SPP Bluetooth profile (Serial Port Profile). Required accessories: AUMA CDT (Commissioning and Diagnostic Tool for Windows-based PC) Options: Selectable type of seating, limit or torque seating for end position OPEN and end position CLOSED Torque by-pass: Adjustable duration (with adjustable peak torque during start-up time) Start and end of stepping mode as well as ON and OFF times: can be set individually for directions OPEN and CLOSE, 1 to 1,800 seconds Any 8 intermediate positions between 0 and 100 %, reaction and signal behavior programmable Running indication blinking: can be set Positioner: - Position setpoint via fieldbus interface - Automatic adaptation of dead band (adaptive behavior selectable) - Change-over between OPEN-CLOSE control and setpoint control via fieldbus PID process controller: with adaptive positioner, via 0/4 20 ma analog inputs and Profibus for process setpoint and actual process value Multiport valve: up to 12 positions, signals (pulse or edge) Automatic deblocking: up to 5 operation trials, travel time in opposite direction can be set Static and dynamic torque recording for both rotation directions with torque measurement flange as additional accessory Y004.679/065/us Issue 1.15 Page 3/6

Safety functions Monitoring function Diagnostic function EMERGENCY operation (programmable behavior) - Via additional input (option, low active) or via fieldbus interface - Reaction can be selected: Stop, run to end position CLOSED, run to end position OPEN, run to intermediate position - Torque monitoring can be by-passed during EMERGENCY operation - Thermal protection can be by-passed during EMERGENCY operation (only in combination with thermoswitch within actuator, not with PTC thermistor). Release of local controls via fieldbus interface: Thus, actuator operation can be enabled or disabled via push buttons on the local controls. Local STOP: - The actuator can be stopped via push button STOP of local controls if the selector switch is in position REMOTE (Not activated when leaving the factory). Interlock for main/by-pass valve: Enabling the operation commands OPEN or CLOSE via two digital inputs EMERGENCY Stop push button (latching): interrupts electrical operation, irrespective of the selector switch position. PVST (Partial Valve Stroke Test): programmable to check the function of both actuator and actuator controls: Direction, stroke, operation time, reversing time Lockable cover for local controls with/without viewing glass, for protection against vandalism. Valve overload protection: adjustable, results in switching off and generates fault signal Motor temperature monitoring (thermal monitoring): results in switching off and generates fault indication Monitoring the heater within actuator: generates warning signal Monitoring of permissible on-time and number of starts: adjustable, generates warning signal Operation time monitoring: adjustable, generates warning signal Phase failure monitoring: results in switching off and generates fault signal Automatic correction of rotation direction upon wrong phase sequence (3-ph AC current) Electronic device ID with order and product data Logging of operating data: A resettable counter and a lifetime counter each for: - Motor running time, number of starts, torque switch trippings in end position CLOSED, limit switch trippings in end position CLOSED, torque switch trippings in end position OPEN, limit switch trippings in end position OPEN, torque faults CLOSE, torque faults OPEN, motor protection trippings Time-stamped event report with history for setting, operation and faults: - Status signals according to NAMUR recommendation NE 107: "Failure", "Function check", "Out of specification", "Maintenance required" Torque characteristics (for version with MWG in actuator): - 3 torque characteristics (torque-travel characteristic) for opening and closing directions can be saved separately. - Torque characteristics stored can be shown on the display. Motor protection evaluation Standard: Monitoring the motor temperature in combination with thermal switches within actuator motor Options: Thermal overload relay in controls combined with thermal switches within actuator PTC tripping device in combination with PTC thermistors within actuator motor Overvoltage protection (option) Protection of the actuator and control electronics against overvoltages on the fieldbus cables of up to 4 kv Electrical connection Standard: AUMA plug & socket connector with screw-type connection Options: Terminals or crimp connection Gold-plated control plug (sockets and plugs) Threads for cable entries Standard: NPT threads Options: PG-threads, G-threads, metric threads Wiring diagram (basic version) TPCAA000-1A1-A000 TPA00R1AA-0A1-000 Further options for version with MWG in actuator Setting of limit and torque switching via local controls Torque feedback signal Via fieldbus interface Galvanically isolated analog output 0/4 20 ma (load max. 500 Ω). Option, only possible in combination with output contacts. Y004.679/065/us Issue 1.15 Page 4/6

Setting/programming the interface Baud rate setting Automatic baud rate recognition Setting the fieldbus address The address is set via the AC 01.2 display. Configurable process representation via GSD file For optimum adaptation to the process control system, the process representation input (feedback) can be freely configured. General interface data Communication protocol according to IEC 61158 and IEC 61784 Network topology Line (bus) structure. When using repeaters, tree structures can also be implemented. Coupling and uncoupling of devices during operation without affecting other devices is possible. Transmission medium Twisted, screened copper cable according to IEC 61158 interface EIA-485 (RS-485) Transmission rate/cable length Baud rate (kbit/s) Max. cable length (segment length) without repeater Possible cable length with repeater (total network cable length): 9.6 93.75 187.5 500 1,500 3,937 ft [1,200 m] 3,281 ft [1,000 m] 1,312 ft [400 m] 656 ft [200 m] approx. 6.2 miles [10 km] approx. 6.2 miles [10 km] approx. 2.5 miles [4 km] approx. 1.2 miles [2 km] Device types DP master class 1, e.g. central controllers such as PLC, PC,... DP master class 2, e.g. programming/configuration tools DP slave, e.g. devices with digital and/or analog inputs/outputs such as actuators, sensors Number of devices 32 devices without repeater, with repeater expandable to 126 Fieldbus access Token-passing between masters and polling for slaves. Mono-master or multi-master systems are possible. Supported functions Cyclic data exchange, sync mode, freeze mode, fail safe mode ident no. 0x0C4F: Standard applications with -V0 and DP-V1 0x0CBD: Applications with -V2 Commands and signals of the interface Process representation output (command signals) Process representation input (feedback signals) Process representation input (fault signals) Behavior on loss of communication OPEN, STOP, CLOSE, position setpoint, RESET, EMERGENCY operation command, enable LOCAL, Interlock OPEN/CLOSE End positions OPEN, CLOSED Actual position value Actual torque value, requires MWG in actuator Selector switch in position LOCAL/REMOTE Running indication (directional) Torque switches OPEN, CLOSED Limit switches OPEN, CLOSED Manual operation by handwheel or via local controls Analog (2) and digital (4) customer inputs Motor protection tripped Torque switch tripped in mid-travel One phase missing Failure of analog customer inputs The behavior of the actuator is programmable: Stop in current position Travel to end position OPEN or CLOSED Travel to any intermediate position Execute last received operation command Y004.679/065/us Issue 1.15 Page 5/6

Service conditions Use Indoor and outdoor use permissible (not permissible for use in potentially hazardous locations) Mounting position Any position Installation altitude 2,000 m above sea level > 2,000 m above sea level on request Ambient temperature Standard: 22 F to 158 F ( 30 C to +70 C) Options: 76 F to 140 F ( 60 C to +60 C), extreme low temperature version Low temperature versions incl. heating system for connection to external power supply 230 V AC or 115 V AC. Humidity Up to 100 % relative humidity across the entire permissible temperature range Enclosure protection according to EN 60529 Standard: IP68 (NEMA 4X/ 6P) with AUMA 3-phase AC motor/1-phase AC motor For special motors, differing enclosure protection is possible Option: DS Terminal compartment additionally sealed against interior (double sealed) According to AUMA definition, enclosure protection IP68 meets the following requirements: Pollution degree according to IEC 60664-1 Vibration resistance according to IEC 60068-2-6 Depth of water: maximum 26 ft (8 m) head of water Duration of continuous immersion in water: Max. 96 hours Up to 10 operations during continuous immersion Modulating duty is not possible during continuous immersion. Pollution degree 4 (when closed), pollution degree 2 (internal) 1 g, from 10 Hz to 200 Hz Resistant to vibration during start-up or for failures of the plant. However, a fatigue strength may not be derived from this. (Not valid in combination with gearboxes.) Corrosion protection Standard: KS Suitable for use in areas with high salinity, almost permanent condensation, and high pollution. Option: KX Suitable for use in areas with extremely high salinity, permanent condensation, and high pollution. Coating Double layer powder coating Two-component iron-mica combination Color Standard: AUMA silver-gray (similar to RAL 7037) Option: Available colors on request Accessories Wall bracket For AC 01.2 mounting separately from the actuator, including plug & socket connector, connecting cable on request Recommended for high ambient temperatures, difficult access, or heavy vibration during service. Cable length between actuator and AC 01.2 max. 100 m. (Not suitable for version with potentiometer in the actuator.) Instead of the potentiometer, the actuator has to be equipped with an electronic position transmitter. (Cable length for non-intrusive version with MWG in the actuator max. 328 ft (100 m) requires separate data cable for MWG.) Programming software AUMA CDT (Commissioning and Diagnostic Tool for Windows-based PC) Torque measurement flange DMF Accessory for torque measurement for SA/SAR 07.2 to SA/SAR 16.2 Further information Weight Directives and compliances Reference documents Approx. 15 lbs [7 kg] (with AUMA plug & socket connector) Canadian Standards Association (CSA): (C22.2) Electromagnetic Compatibility (EMC): (2004/108/EC) Low Voltage Directive: (2006/95/EC) Machinery Directive: (2006/42/EC) Brochure Electric actuators for industrial valve automation Dimensions Multi-turn actuators with AUMATIC integral controls Dimensions Part-turn actuators with AUMATIC integral controls Y004.679/065/us Issue 1.15 Page 6/6