FROG-4000TM Quick Start Guide

Similar documents
Operation of the Toxic Organic Chemical Air Monitor (TOCAM ) with the Ellvin Chromatography Software

PerkinElmer Series 200 HPLC: Operating Procedure

Aqueous GPC Instructions - Detailed

Equipment Overview: Safety:

Using the SASS 2300 Wetted-Wall Air Sampler

Appendix 1: DataStudio with ScienceWorkshop Sensors Tech Tips

Manual HPLC-4 Alliance-UV

The Olis Titrator Series

impact INSTRUCTIONS LiteTrek 4.0 Monolight lighting equipment and accessories

Removal and Installation8

Oven Loggermaster BEVS User Manual

MINISCAN INSTRUCTIONS

Turntable player with USB/SD/PC recording function. Model no: TT620 User s Manual

Quick Start Guide. January EAZ0081L02A Rev. A

USER GUIDE. Salinity Meter Pen Style Water Quality Meter. Model EC170

Quick Start Guide Notion Ink Design Labs Pvt. Ltd. 1

minipcr Mobile App operation (Android devices) Appendix: maintenance and operating conditions

Detailed procedures, operation instructions, maintenance, and emergency contact information list is attached.

-bio. Densitometer DEN-1B Operating instructions

Operating Manual. High Performance Liquid Chromatograph. Scientific Equipment Center, Prince Of Songkla University

- 1 - TITRAMAX OPERATING MANUAL

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Appendix C. Vernier Tutorial

STANDARD OPERATING PROCEDURE AA SERIES AA-160 PRECISION BALANCE

ARTiPRO. User Manual. (Model 910 & 920)

User Guide. Model Temperature Datalogger Kit Model Temperature and Humidity Datalogger Kit Model SW276 Datalogging Software SW276

iq DIGITAL PICTURE FRAME iq Digital Picture Frame DPF701SB USER GUIDE

AEROTRAK PORTABLE AIRBORNE PARTICLE COUNTER MODEL 9310/9350/9510/9550/9500 QUICK START GUIDE

Chromeleon software orientation

Installation Manual. 65 Interactive LED/LCD. Model: HILF65101 (64.56 )

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

Chapter 2: Disassembly

HP UPS R/T3000 ERM. Overview. Precautions. Installation Instructions

Model ST-FT1 DIGITAL FORCE / TORQUE INDICATOR. User s Guide

Student Quick Reference Guide

Quantichem 9065C Portable Luminescent Dissolved Oxygen Analyzer Quick Reference Manual

ph, ORP, and TDS ORP Continuous Monitor OPERATING INSTRUCTIONS 8. Warranty 9. Return of Goods

User Guide. Version 2.

F U E L C E L L S U P E R V I S O R H 2

User Guide. Video Borescope. Models BR200 and BR250

User Guide on installation of TPCAST Wireless Adaptor for VIVE

User s Manual BeamPod User Manual

Central Controller Operation & Installation Manual

Section. Service & Maintenance. - Core & Hard Disk Drive (HDD) - Amplifier - Monitor - UPS - Dollar Bill Acceptor - Fan Filter G - 1

To connect the AC adapter:

User Manual. 1U LCD Keyboard Drawer. KwikDraw - A Series. Manual. IT and Instrumentation for industry. - With KVM options - 15", 17, 19 screen size

User Manual Revised 1-July-2015

4-20 ma Current Data Logger

VALCON EasyWriter Ver1.0E Manual

FT-20 Fire Training Fog Machine User Manual English

CH142: Instructions for the Vernier LabPro

Eltek TU GenII AQ110A comprehensive portable air quality monitor transmitter

6 x 6 Peltier-Thermostatted Multicell Holder Series II Accessory

FUTEK USB Software Version User s Manual

smartentry Wireless Video Doorphone User Manual

montana 600 series quick start manual for use with models 600, 650, 650t Montana 600 Series Quick Start Manual 1

Moving your printer 1. Remove cables. Printing Moving the printer. Using color. Paper handling. 1 Turn the printer off. Maintenance.

USER MANUAL Video Particle Counter with built in Camera Model VPC300

User Manual Digi-Sense 12-Channel Benchtop Data Logging Thermocouple Thermometer

Premium Continuous Ink Supply Systems.

FOCIS Flex - No Wireless Fiber Optic Connector Inspection System User Guide

HP Notebook PCs - Keyboard and TouchPad or ClickPad Guided Troubleshooter

Table of Contents. Chapter 1. Safety Precautions Notice Chapter 2. Components and accessories Chapter 3. Camera components...

STANDARD OPERATING PROCEDURES SOP : 1736 PAGE: 1 of 35 REV: 0.0 DATE: 09/25/06 MEASUREMENT OF AIR CHANGES USING THE WOLFSENSE IAQ PROBE

QUICK START GUIDE FOR YOUR CLEAR TOUCH INTERACTIVE DIGITAL DISPLAY

FlowAccess TM GETTING STARTED. Windows software for Skalar SAN plus systems. Version and up

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

EPS 06 in rear housing type A1

Montgomery County Community College Document Number: DP DeKalb Pike Revision Number: 2. Page 1 of 9 SOP: BioLogic LP Chromatography System

DOWNLOAD PDF DELL VENUE 8 PRO 5830 MANUAL

Innovative K5 Palm Size LED Projector.

User Guide. ExStik FL700. Fluoride Meter

QL5-EX Quick Start-up Guide

User's Guide. Video Borescope. Models BR200 and BR250

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

NEBULA X USER MANUAL. Redefining Tradition. Read carefully before using the device and save these instructions.

FT-20 Fire Training Fog Machine User Manual English

MDVR-14 SOLID STATE MINI DVR User Guide

Instruction Manual. RS 3D Printer

*520886* IntelliTouch Pool & Spa Control System MobileTouch Wireless Controller. User s and Installation Guide. P/N Rev A

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Vertiv Local Rack Access 18.5" LED LCD Console

Formaldehyde Thermo-Hygrometer

TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT. Pool Professional s Meter

Keyser Manufacturing Travel Indicator

Anatomage, Inc. 111 N. Market St. Suite 500 San Jose, CA USA Page 1 of 16 - TS001 Rev A. 9. Apr.

Ultra High Brightness Professional Monitor User Manual

User Manual RecoMedia Presentation made easy

* IMPORTANT * REGISTERING YOUR MACHINE

Installing the Dye Sublimation Printing System

NEC VersaBay IV 6-Cell Secondary Battery

Inspection Camera. User Manual

SPECIFICATIONS SYRINGE SAMPLER KZ-31W Higashimotomachi, Kokubunji, Tokyo , Japan. No E Printed in Japan

User Manual for the Antari M-1 Mobile Fog Machine

67 Series Spectrophotometer PC Software

CH142 Spring Spectrophotometers with Vernier Data Acquisition Software

DNG-200 LOW FOG GENERATOR USER MANUAL DNG-200 低煙機使用說明書

USER GUIDE. Differential Thermometer Datalogger. Model HD200

MW-145BT Mobile Printer

1690-Series Logic Analyzers

Transcription:

FROG-4000TM Quick Start Guide 1 Precautions DO NOT invert the instrument with the sparge bottle attached. DO NOT transport or store the instrument with liquid in the sparge bottle. DO NOT handle or carry system when sample is being analyzed. NOTE: The battery is disconnected for shipping. To reconnect: remove the two thumbscrews on bottom near rear, slide off back cover, plug in battery, and replace back cover. Charging the Battery 1. Plug the battery charger (supplied with the FROG) into battery charge port (S) and an outlet source. The current switch can be on 0.9A or 1.8A. 2. While the battery is charging, the light on the charger switch is red. 3. When the battery is completely charged, the light on the charger switch is green. ON Battery Access Connecting to Ellvin Recommended Computer Specifications: Pentium dual core or faster, Windows 7 or more current, and 2 GB memory. 1. Install Ellvin onto laptop or PC. (Select setup on the Elvin software CD or USB drive) 2. Connect serial data cable (supplied) to serial data port (Q) and to USB port on computer. The computer will search and find the driver for the cable in Ellvin. 3. Connect power cable (supplied) to the instrument s power port (R) 9V POWER, or use battery power. 4. Turn the instrument power switch to the ON position (fully up). The instrument display screen will be visible. 4. Open Ellvin by double clicking on the Ellvin icon. 5. Ellvin opens in the default Live Data Window. 6. Click on PORT and select the appropriate COM number to connect the instrument to the computer. Q R S Serial Data Cable to Q Power Cable to R Battery Charger to S NOTE: Refer to User s Manual to adjust instrument settings or recalibrate the instrument, if necessary. NOTE: If you cannot connect to the FROG, verify that you have the driver for the communication cable. If not, the driver is located on the software disk (or USB drive) in a folder labeled USBtoSerialDrivers. Preparing the Instrument A. Rinse the Instrument LOAD 1. Place the load/analyze valve in the LOAD position. 2. Attach sparge bottle in the DOWN position. 3. Attach syringe with 5mL deionized water. 4. Transfer the 5mL water into the sparge bottle. 5. Remove and empty the sparge bottle. 1 6. Repeat steps 3-5 for at least two rinses. 7. Create a clean baseline in Ellvin by running a blank sample. Þ Follow the instruction for Loading a Sample and Running a Sample using 5mL deionized water. The FROG must be connected to Ellvin to verify a clean baseline. 2 NOTE: It is best to have a clean baseline before attempting sample analysis. 3 Clean Baseline in Ellvin 4 5

2 Quick Start Guide Loading a Sample 1. Sample Preparation: Þ Liquid Sample: Pull 5mL of the desired liquid into 5mL syringe. Þ Soil Sample: Place 1g soil in sparge bottle. (An application note for Methanol Extraction can be found on our website.) 2. Place the load/analyze valve in the LOAD position. 3. Slip bottle over green tube (sparge needle). 4. Attach syringe to the instrument and transfer the sample to the sparge bottle. Þ For Soil Sample: Fill the syringe with 5mL deionized water, then attach it and transfer the water to sparge bottle containing the soil sample. 5. Attach sparge bottle in the UP position and gently tighten the sparge bottle nut counter clockwise. 6. Place load/analyze valve in the ANALYZE position. LOAD ANALYZE 1 2 3a 3b 4 5 Running a Sample 1. Instrument screen reads READY 2. Record Log # and other relevant sample data for future reference. 3. Press the start button in Ellvin or on the instrument to begin an analysis cycle. 4. As the analysis cycle proceeds, the instrument screen displays the analysis steps. 5. If connected to Ellvin, a chromatogram of results is displayed on the computer screen. 6. If not connected to Ellvin, the instrument screen displays a chromatogram when the cycle is finished. 7. If not connected to Ellvin, press the instrument start button to scroll through analyte concentration estimates. 8. Before loading/running another sample, a. Empty the Sparge bottle. b. Wait for the instrument screen to read READY. NOTE: Samples must be run from low to high concentrations. Rinse the instrument and create a clean baseline between runs if concentrations are unknown. VOC ANALYZER GC TEMP: 40C READY LOG_016 BTEX V. 965 2012 5 or CLEANING 4 4 1, 2 3 6 BENZE 33PPB 48.33S 7 For more detailed instruction, refer to the FROG-4000 TM User s Manual

3 Working with Ellvin/Instrument Files Files The instrument stores a data file for every sample analysis on an internal SD card. If analyses are performed while the instrument is connected to Ellvin, the files are also stored on the user s computer. Files stored on the SD card are labeled with a LOG# that the instrument automatically assigns to each run. The LOG# is displayed on the instrument screen at the start of each run. The user should record the LOG# and other relevant sample information for future reference. Files saved by Ellvin on the user s computer are in XML format and are labeled with the LOG# and the time they were created by Ellvin. A separate data file is created for each analysis. The user should record the time, date and other relevant sample information. The Ellvin notes window may be used for this purpose. VOC ANALYZER GC TEMP: 40C READY LOG_016 BTEX V. 965 2012 Importing LOG files from the instrument into Ellvin N Method A, Best Practice: 1. Connect Port N on the instrument to a computer using the USB- Cable (supplied). Turn the instrument on. 2. The computer screen will display an option to Open folder and view files. Open the folder and the screen displays a list of sequential files named LOG_XXX. 3. Select the LOG file of interest and drag/copy it to the computer. 4. Open Ellvin. 5. Open Live Data Window 6. Click the Open Button. 7. Browse to the location where the LOG file of interest was dragged/copied. 8. At the bottom of the Select Data File window, change Files of Type to LOG Files. ON USB Cable to N 9. Select the LOG file of interest and open it. 10. The computer now displays a chromatogram of the file data as it is imported into Ellvin. At this time, Ellvin also converts the data to an XML format, labels it with the time it was converted (not the time it was recorded on the instrument) and stores it. Ellvin stores the XML file in a folder labeled with the date that the data was converted. The location path of the stored data is displayed at the top of the chromatogram in the Live Data Window. Data Location Path Method B: 1. Connect Port N on the instrument to a computer using the USB-Cable. Turn the instrument on. 2. Open Ellvin, open Live Data Window, click on the Open Button. 3. Select the instrument from the Look In drop-down menu at the top of Live Data Window. 4. Change Files of Type to LOG Files. 5. Select the LOG file of interest and open it.

4 Working with Ellvin/Instrument Files Opening Files in Analyze Window 1. Click on the Analyze Tab. 2. Click on the Open Button and a file selection appears. 3. Use the drop down list labeled Look In to select the FOLDER labeled with the DATE that Ellvin created/converted the file of interest. 4. Click on the file of interest and a preview chromatogram appears on the right side of the screen. The XML FILES are labeled with the TIME that Ellvin created/converted them and the LOG number. 5. Click Select to open the file for analysis. Folder name is the Date File name is the Time followed by the LOG #

5 Ellvin Windows Ellvin, Chromatogram Software, has four windows that are accessed with tabs when the software is open. Window Tabs in Ellvin Live Data Window This is the default window for Ellvin. In Live Data Window, Ellvin creates a chromatogram from sample analysis data. The data source may be: a. From the instrument, while it is running a sample, and connected to Ellvin. b. From sample data previously recorded on the instrument s SD card, then imported to Ellvin. Features in Live Data Window Port The user designates a COM# in the Port drop down list to connect the instrument to a computer. Connection Port When the correct COM# is designated in Port, the Connection Port indicates that the instrument is CONNECTED, and whether or not parameters have been updated. GC Column Temperature Indicator Displays the GC temperature. The icon is GREEN when instrument is ready for loading. The icon is RED when the GC is cooling. Start/Stop Button Click on this button to start an analysis cycle. Once the analysis has begun, clicking the button will stop the analysis. Notes Record notes about samples for future reference. The notes are saved when the sample analysis is completed. Move Use this tool to move the chromatogram up and down the Y-axis. Magnifying Glass Use this tool to zoom into a chromatogram. To Magnify: 1. Left click and drag the mouse over the area to be magnified. 2. Release the mouse button. 3. The area being magnified is highlighted light blue and the display readjust to show the magnified area. To revert to normal view double click the left mouse button on the magnifying glass.

6 Ellvin Windows Features in Live Data Window Continued Open Use this button to open saved files. 1. Click on the Open button. 2. Browse to the LOG file or XML file of interest s location on the computer. 3. In the Select Data File window, select the appropriate Files of Type. 4. Select the file of interest and open it to view a chromatogram of the sample. Chromatogram Display Screen The software display screen shows sample analysis data. The X-axis is time in seconds. The Y-axis shows the instrument s PID response and GC temperature ( o C). The peaks correspond to separated analytes. The Key explains colored lines that are shown on display screen. Analyze Window Ellvin displays a chromatogram from sample analysis data. In Analyze Window, Ellvin retrieves analysis data stored on the user s computer. In addition to all of the features in Live Data Window, the following features are available in Analyze Window: Integrator 1 The user creates a baseline and integrates peaks, then calculates the peak height and area to determine analyte concentrations. Beginning and ending points of the integration are based on the cursor position. Integrator 2 With Integrator 2, Ellvin snaps to the vertical point on the data line closest to the cursor position. Integrator 2 is recommended for ease of use. 1. Based on retention times, determine which peak(s) to integrate. 2. Click and hold the mouse at the valley before the first peak to integrate (In figure below: Valley 1). 3. Drag the mouse to the valley after the peak to integrate (In figure below: Valley 2). Do not drag the line through the peaks. A highlighted area displays the integrated peaks. 4. When the integration is complete, a black line appears and the data grid reports the results. Auto Analyze The Auto Analyze tool integrates all the peaks present. Valley 1 Valley 2 1,2 3 4 5 6 7 8

7 Ellvin Windows Calibration Window In this window, Ellvin uses analysis data from chemical standards to calibrate the instrument. Features of Calibration Window: List of Analytes Create a list of analytes that will be used to calibrate the instrument. 1. Enter the name of the calibration analyte in the Analyte Name window. 2. Create and enter an abbreviated name for the analyte in the Analyte Alias window (maximum of 5 Characters). 3. Click the ADD button. Correlation Chart and Equations This feature in the Calibration Window displays the degree of correlation between analyte standards of varying concentrations and the instrument s response to them. The correlation is calculated as both a linear equation and a 2nd order quadratic equation. The user may view the equations and chart for either Peak Area correlation or for Peak Height correlation. Ellvin uses these parameters to calculate concentrations for future samples.

8 Ellvin Windows Side D Settings Window In this window, Ellvin manages the settings for the instrument. The settings define temperature and duration parameters for various phases of the instrument s analysis cycle. The settings for optimal instrument performance depend on the target analyte and should be set accordingly. The table below describes the various instrument settings. Settings T a T b Description Hold time at lower GC temperature (seconds) Ramp time from GC cold to GC hot temperature (seconds) Type in a non-zero integer then click SET to apply the settings to the instrument. Changes to the settings are stored on the instrument and DO NOT revert to the default settings when power is removed or computer is disconnected. T c Hold time at hot GC temperature (seconds) C t Initial cold GC temperature ( o C) H t Final hot GC temperature ( o C) CLEAN PRESETTLE COLLECT SETTLE FIRE Time cleaning PC by heating (seconds) Time PC cools after cleaning (seconds) Collection time of analytes onto PC (seconds) Time allowed for pressure to stabilize before PC FIRE (seconds) Time PC is heated to release analytes (seconds) 30 40

9 FROG-4000 TM Air Sampling Kit The air sample kit includes an air sampler, a couple line, a transfer line, an adaptor and one air sample wand. 1. Connect body of air sampler to FROG sparge needle. (Figure 2). Be sure the valve is pointing to the right as shown in figure 3. Valve Control Sparge Needle Port Coupler Line Transfer Line ANALYZE Position Air Sampler Figure 3: Sample Introduction Valve Adapter Figure 1: Air Sampler Kit Air Sampler Wand Figure 2: FROG sparge needle 2. Attach the air sampler unit air sampler power port as shown in Figure 4. This connection supplies power 3. Attach exhaust connector to FROG exhaust port with a twisting motion (Figure 5). to the air sampler Figure 4: Power air sampler by connecting to this port. Figure 5: Connect exhaust connector to exhaust port.

10 Air Sampling 4. The air sampler can now be connected to a Tedlar bag to calibrate the instrument or to the wand to collect air samples. Tedlar Bag Calibrate the instrument. Wand 5. Press the yellow start button on the instrument or in Ellvin to begin an air sample analysis. Collect air samples. or

11 FROG-4000 TM Soil Sampling Soil sampling requires a scale, scapula, disposable weigh boats. (Figure below) 1. Measure 1g of soil to be tested in a clean, disposable weigh boat or in a soil syringe. (Figure 2) 2. Add soil directly to sparge bottle (Figure 3) 3. Place sparge bottle in down position on Frog-4000 4. Add 5mL of DI water using a glass or disposable syringe (Figure 4). Be sure the valve position is facing toward you 5. Turn valve position counterclockwise to the right, place sparge bottle in up position on Frog-4000, and tighten the nut around sparge bottle 6. Run Frog-4000 as normal by either using Play button in Ellvin software, or pressing the yellow button on the side of Frog-4000 NOTE: A separate application note on Methanol Extraction can be found on our website /downloads.php Figure 2: 1g of soil to be tested Figure 3: Soil put directly into sparge bottle Figure 4: Adding 5mL of DI water to soil Note: For Methanol Extraction, please visit for application note. or

12 Battery Charger Information for FROG-4000 TM FROG-4000 TM Battery and Battery Charger Specifications Battery Pack Type Battery Charger Input NiMH 100 240V AC Battery Pack Voltage 9.6V Battery Pack Capacity 5000mAh Battery Charger Current Selection (switch) 1.8A Charging Time Approximately 210 Minutes LED Indications Green LED Red LED On, Not Flashing Battery is fully charged. Battery is charging. The green light and the red light will flash twice alternately when the charger is powered on. Off The charger is off. Causes: Short circuit, reversed polarity, battery temperature above 60 o C, or 4 hours safety timer exceeded. Precautions and Safety Features: Do not use the charger for battery packs with capacity less than 900mAh or greater than 5000mAh. Do not use the charger for battery packs under 9.6V or over 18V. The charger will shut off if voltage is below 6V. Use charger only for NiMH or NiCd battery packs. Highly recommend using Tenergy brand, high drain rate battery packs. Neither Defiant Technologies nor Tenergy Corporation are responsible for damage caused by charging other battery pack brands with this charger. Use 1.8A current for battery packs with capacities between 1800mAh and 5000mAh. Limit the duration of charging when using 1.8A current. The charger automatically shuts off after 4 hours charging. The charger is designed for indoor use. Use the charger in a well-ventilated, dry area away from flammable, explosive goods. The charger is designed to be used on a horizontal surface. Instructions for Charging the Battery: 1. Remove the sparge bottle from the instrument before charging the battery. 2. The Instrument should be powered off and disconnected from the power cable. 3. Plug battery charger into Battery charge port (S) and outlet source. 4. Place battery charger switch to 1.8A. 5. While the battery is charging, the light on the charger switch will appear red. 6. When the battery is completely charged, the light on the charger switch will appear green. 7. It is recommended that the battery be fully charged before the instrument is used in an outdoor setting. S, Battery To S, Battery Charge To Outlet

13 Frog-4000 Packing Instructions: Item List 1. Syringe 2. Sparge Bottle 3. Frog (With Sparge Tube Protector) 4. Serial Data Cable 5. USB Cable to N 6. Battery 7. Air Sampler a. Transfer Line b. Air Sample Couple Line c. 1/16-3/16 Adapter 8. Power Cable 9. Battery Charger 10. Power Cord 11. 60 ml Rinsing Syringe 6 3 c 1 2 4 5 c 7 a b 7d 8 9 10 11

14 1. 2. 3. 4. 5. 6. 7. Frog-4000 Packing Instructions: Item Locations 1 Syringe Sparge Bottle Frog (With Sparge Tube Protector) Serial Data Cable USB Cable to N Battery Air Sampler a. Transfer Line b. Air Sample Couple Line c. 1/16-3/16 Adapter d. Air Sample Wand 8. Power Cable 9. Battery Charger 10. Power Cord 11. 60 ml Rinsing Syringe 3 4 3 8 9 10 6 11 7d 5 7 abc 2