Important Information, Please Read Before Use!

Similar documents
Important Information, Please Read Before Use!

Important Information, Please Read Before Use!

MA100 full-range speaker. user manual

Achat 115M full-range speaker. user manual

Pyrit 212 Sub A active subwoofer. user manual

AMP20. User Manual.

PA18 ECO MKII passive subwoofer. user manual

SB 115A active subwoofer. user manual

TA12 full-rangespeaker. user manual

Achat 110 MA active full-range speaker. user manual

HP4 headphone amplifier. user manual

Achat 112 MA Achat 112 MA WH full-range speaker. user manual

DMX Splitter 4 MKIII 19" DMX splitter. user manual

Achat 110 M passive full-range speaker. user manual

ImportantInformation, PleaseReadBeforeUse!

MA5 active monitor. user manual

VERA36 Operating Manual

VERA S30 Operating Manual

Introduction. Operating Manual M6 WARNING WARNING CAUTION NOTE TIP. Instructions in the operating manual

DPX-620III 6-Ch. dimmer pack. user manual

D610H, D610H MKII, D610S, D610T dimmer pack. user manual

PROFESSIONAL AUDIO SYSTEM SP220 OPERATING MANUAL. Ver. SP220-EN-1.1

CS2 DMX Distribution Splitter

D1210H dimmer pack. user manual

APC100. User Manual.

TPC25 active crossover. user manual

AV-1600 DIGITAL AMPLIFIER OWNERS MANUAL

TA18 active subwoofer. user manual

BGS 20T 100V/8Ω Background Music Loudspeakers

Pyrit 112 Sub A active subwoofer. user manual

PRE116/126. User Manual.

Crossfire. User Manual. Order code: EQLED061

PA12 DSP active speaker. user manual

DDC-6, DDC-12 LCD DMX controller. user manual

HP4 headphone amplifier. user manual

R Band Parametric Equalizer (6 Center Frequencies)

XENO 8. User & Installation Manual.

Achat 206 passive full-range speaker. user manual

R-503 Parametric Equalizer + 2 Shelf Baxandall (BAX) bands

SP-1800 OWNERS MANUAL

UV Power Flood. User Manual. Order code: EQLED029

CPD SERIES OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier.

Blitzer Strobe. User Manual. Order code: EQLED366

Mon P10, Mon P12, Mon P15 passive monitor. user manual

PowerPlant Tuner tuner pedal with power distribution. user manual

J-INFRA Manual (1.1 EN)

MP SERIES PROFESSIONAL POWER AMPLIFIER

PUBLIC ADDRESS SYSTEM

PAR56 10MM UV LED PAR. user manual

Gobo Projector XP 80W

LED Pixel Rail Drive 640 controller. user manual

Configurable Network Paging Console. Product Instructions. Model: X-NPMI

SP-1400P POWERED SPEAKERS OWNERS MANUAL

APT20. User Manual.

PF LED Profile. User Manual

CDP 405 Digital Dimmer Pack

HEX Par 9 MKII. Exterior Fixture User Manual. Order code: LEDJ226

D-SEED effects pedal. user manual

DS-2 RF DMX dimmer. user manual

User s Manual Model PBL100 Logic Probe IM E. 4th Edition

ZF LED Zoom Fresnel. User Manual

Harley Benton Power-Attenuator power attenuator. user manual

USER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH

UP-1-1 Channel Dimmer. User manual. dimmer pack

Installing and Configuring Rialto Analytic Appliances

HBAC-30. Owner s Manual. Battery powered Guitar Amp

B2-SUB Manual (3.1 EN)

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

VeniceF16/VeniceF16R/ VeniceF24/VeniceF32

VeniceU16/VeniceU24/VeniceU32

UP-1-1 Channel Dimmer dimmer pack. user manual

SP-1200P POWERED SPEAKERS OWNERS MANUAL

RGB Power Batten. User Manual. Order code: EQLED032

Microbar COB System. User Manual. Order code: EQLED137

Blitzer RGB Strobe. User Manual. Order code: EQLED365

Q-SUB Manual (2.3 EN)

MODEL 805 USER MANUAL

PROFESSIONAL AUDIO SYSTEM

FTP1 Single Channel LED DMX Driver

C4-SUB Manual (3.0E)

Flexoled FTP3HP RGB LED DMX Driver

DDS-405 LC DMX 4 Ch. Dimmer dimmer pack. user manual

DMX LED Starcloth Systems

User Instructions. American DJ

PA 4080 KB keyboard combo. user manual

OWNER S MANUAL. Additional Camera Unit AC-CAM-210 Compatible with AC210 Baby Video Monitor TABLE OF CONTENTS

WARNING! CAUTION! IMPORTANT! References in the manual. This refers to a p otentially dangerous situation which may lead to personal injury.

Installation manual plugs and connectors with screw connection (16/32 A)

DDS 405 digital dimmer and switcher. user manual

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Performer 18 HEX. 18 x 12W 6-in-1 colour LEDs (RGBWAUV) User Manual. Order code: LEDJ252B

Performer 18 RGBWA MKII

CPA 40 Two Channel Amplifier

Classic Flanger effects pedal. user manual

UA-2X2 audio interface. user manual

LED Commander 16/2 DMX controller. user manual

THANK YOU FOR CHOOSING ORANGE

MA V 30W Mixer Amplifier Order code: CRAM02 MA V 60W Mixer Amplifier Order code: CRAM03 USER MANUAL

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

HP-101 HEADPHONE AMPLIFIER

Transcription:

Translation of the original instructions Important Information, Please Read Before Use! KLING & FREITAG GmbH Junkersstraße 14 D-30179 Hannover TEL +49 (0) 511 96 99 70 FAX +49 (0) 511 67 37 94 www.kling-freitag.de Released: 07.02.2017

Table of contents 1 Introduction 4 1.1 Icons Used 4 1.2 About this Manual 4 2 Product Description 5 3 General Safety Instructions 5 4 Connectors and Functions 6 4.1 4.1.1 4.2 Front 6 Speaker port 6 Rear 6 5 AES/EBU Link 8 6 Wiring 8 6.1 Notes 8 6.2 Connection 9 6.2.1 Example 1 9 6.2.2 Example 2 9 6.2.3 Example 3 10 6.2.4 Example 4 11 6.2.5 Example 5 12 7 First-time Use 14 8 Technical Specifications CP+ 15 9 EC Declaration of Conformity 16 10 Disposal 17 10.1 Germany 17 10.2 EU, Norway, Iceland, and Liechtenstein 17 10.3 All Other Countries 17 Page 3 of 19

1. Introduction Thank you for purchasing a KLING & FREITAG product. To guarantee trouble-free operation and enable the device to achieve its full potential, please read these user's manual carefully before use. This connector panel is a high-quality device. As the owner of this system, you now have a versatile and highly professional tool which, when operated properly, is a true pleasure to use. 1.1 Icons Used This icon indicates a risk of injury or death. Not following these instructions may result in serious health problems including potentially fatal injuries. Warning This icon indicates a possibly dangerous situation. Not following these instructions may cause minor injuries or damage. Caution This icon marks instructions for proper use of the described products. Not following these instructions may cause malfunctions or damage. This icon marks information provided for simplified use of the described products. Tip 1.2 About this Manual KLING & FREITAG GmbH. All rights reserved. All specifications regarding the features of the described products and applicable safety guidelines provided in this manual are based on information available at the time of publishing. We assume no responsibility for technical specifications, dimensions, weights, and properties. All information in this manual is subject to change without notice. All persons who use the speaker system must have this guide and all further information for safe operations available to them during assembly, disassembly, and use. The speaker system may neither be set up nor used until these user's manual has been read, understood and kept readily available on site. All KLING & FREITAG manuals are originally authored in German. KLING & FREITAG spare manuals are separately available for order or can be downloaded from our website: www.kling-freitag.de. Contact Us: info@kling-freitag.de KLING & FREITAG GMBH, Junkersstr. 14, D-30179 Hannover Phone +49 511 96 99 70, fax +49 511 67 37 94 (other countries) Page 4 of 19

2. Product Description The CP+ connector panel is a pro-grade audio panel used for making speaker lines and other signal links connected to it available on its front panel. The device is specifically designed for use with the K&F PLM12K44 and PLM20K44 amplifiers. Output ports include 5 SpeakOn ports, 4 analog inputs, and 4 analog link ports. In addition, the system offers 2 AES/EBU inputs (1/2 and 3/4) and 2 AES/EBU link ports (1/2 and 3/4). DANTE streams are supported through 1 primary and 1 secondary RJ45 port. The length of the patch cables at the rear panel is 50 cm (19.7"). In addition to 4 analog inputs (ANALOG IN 1 to 4), there are 2 AES/EBU IN ports (1+2 and 3+4) and 2 2-channel input ports (CH1/CH2 and CH3/CH4). The patchfield is for commercial use as specified in this document only! Any other use not described in this document is not an intended use 3. General Safety Instructions Never place your devices Warning where they are permanently exposed to direct sunlight, near heat sources or open fire, where the airflow for cooling is blocked, where they are exposed to high moisture, where they are exposed to strong vibrations or dust. Transportation When transporting the device, make sure that it is protected from vibrations. Intrusion of liquids It should always be ensured that no liquids get into the device. Maintenance and Technical Service The user should not perform any maintenance or repair work on the unit which goes beyond the work described in these user's manual. This must be carried out by qualified specialist staff. The device may only be repaired by qualified specialist staff when, for example: objects or liquids have got inside the device, the device has been exposed to rain. the device doesn't appear to be functioning properly, it has fallen down or the housing is damaged. Noise RF interference at power cords or line cables may result in unwanted noise. Page 5 of 19

4. Connectors and Functions 4.1 Front 1 2 3 5 6 4 7 8 9 1) Amplified Output (SpeakOn NL8) 6) AES/EBU INPUT 3 and 4 (XLR) 2) Amplified Outputs (SpeakOn NL4) 7) AES/EBU LINK 1 and 2 (XLR) 3) Analog INPUT 1 to 4 (XLR) 8) AES/EBU LINK 3 and 4 (XLR) 4) Analog Link 1 to 4 (XLR) 9) Dante/Remote Primary (RJ45) 5) AES/EBU INPUT 1 and 2 (XLR) 10) Dante/Remote Secondary (RJ45) 4.1.1 10 Speaker port Each of the four SpeakOn output ports (2) delivers 2-channel signals. This allows for implementing system cabling with 4-wire speaker cables. When using K&F 2-channel speaker systems (NOMOS XLC, SEQUENZA 10, ACCESS T5/T9, etc.), ensure correct channel assignment as well as appropriate connection to the amplifier modules. Tip Output 1: Pin 1+/1- = Channel 1 Pin 2+/2- = Channel 2 Output 2: Pin 1+/1- = Channel 2 Pin 2+/2- = Channel 1 Output 3: Pin 1+/1- = Channel 3 Pin 2+/2- = Channel 4 Output 4: Pin 1+/1- = Channel 4 Pin 2+/2- = Channel 3 Page 6 of 19

4.2 1 Rear 2 3 4 1. Dante/Remote Primary (RJ45) 2. Dante/Remote Secondary (RJ45) 3. AES/EBU IN 3+4 (XLR) 4. AES/EBU IN 1+2 (XLR) 5. ANALOG IN 4 (XLR) 6. ANALOG IN 3 (XLR) 7. ANALOG IN 2 (XLR) 8. ANALOG IN 1 (XLR) 9. CH3/CH4 (SpeakOn) 5 6 7 8 9 10 10. CH1/CH2 (SpeakOn) The assignment of the ports 3 to 8: 1: GND/Shield 2: + 3: - Page 7 of 19

5. AES/EBU Link The AES/EBU Link ports are passively wired in parallel to the input ports. We recommend using these for a low number of member units and with short leads only for example, for a direct interconnection of 2 3 racks stacked. Remember to enable AES/EBU termination on the last amplifier in the chain while leaving it disabled on all other amplifiers! For information on this feature, also refer to the Lake Controller user instructions. 6. 6.1 Wiring Notes Only use high-quality speaker cables, (i.e. from KLING & FREITAG). Adapters for connections between the Speakon connecting panel of the CP+ and EP-5 / XLR-connectors, as well as for special uses must be professionally constructed. For routing analog signals from the mixing console to the CP+ and from the CP+ to the input ports of your amplifier, use 2-pole shielded microphone cables. For transmitting AES/EBU digital audio, use 2-pole shielded cables (110-ohm wave impedance). Please pay attention to the respective pin diagrams in these user's manual! Avoid creating ground loops. Make sure that the +/- polarity of the speakers at the amplifier is correct. When simultaneously using power amplifiers from different manufacturers, be sure to use the correct specific pin configuration. It may be necessary to modify the pin configuration on the power amplifiers or on the connectors leading to them. Ensure that the connected speaker channels are working in phase (phase checker). A phase error can also be recognized when the connected channels are used simultaneously. During simultaneous use the bass frequencies become notably quieter or the mid-frequencies such as voices cannot be located. The cables should have a sufficient wire gauge. A minimum wire gauge can be easily calculated with the following formula: 2 Wire Gauge [mm ] = Required Cable Length [m] / 2 x Impedance [Ohm] Please make sure that the total impedance of the loudspeakers is not lower than the minimal load impedance indicated on the power amplifier. Make sure that all units are switched off and all controls are turned down before connecting your system. Page 8 of 19

6.2 Connection To wire the CP+ connector panel inside a rack, connect the amplifier to the rear-panel ports. Doing so will make all ports (speakers, analog and AES/EBU inputs, and network ports) available at the front panel of the rack. This allows for connecting mixing consoles, speakers, players, and other devices right at the front panel. Sample configurations: 6.2.1 Example 1 GRAVIS 8 GRAVIS 8 NOMOS LT NOMOS LT Amp CP+ SpeakOn CAT 5 AES/EBU Remote Lake Controller Page 9 of 19

6.2.2 Example 2 GRAVIS 8 GRAVIS 8 (Delay) (Delay) GRAVIS 12+ GRAVIS 12+ Amp CP+ SpeakOn CAT 5 AES/EBU Remote Lake Controller Page 10 of 19

6.2.3 Example 3 SEQUENZA 5 W SEQUENZA 5 W NOMOS LT NOMOS LT Amp CP+ SpeakOn Dante CAT 5 DJ/Stage Page 11 of 19

6.2.4 Example 4 SEQUENZA 5 W SEQUENZA 5 W NOMOS LT NOMOS LT Amp CP+ SpeakOn AES/EBU LIR CAT 5 Sub Remote Lake Controller Page 12 of 19

6.2.5 Example 5 Page 13 of 19

7. First-time Use Operating the Controller Switch off all equipment and turn down all level controls of the mixing console and the power amplifiers. Wire the speaker systems according to the instructions in these user's manual. Now switch on the mixing console first and at last, the power amplifiers. Always use the before mentioned switching order. Otherwise switching noises may damage the system. If there is interference, turn off all appliances in the reverse order and check all cable connections. Successively turn up the individual power amplifier channels and send a signal with low volume to the system. Check to see if the desired signals are applied to the intended speakers and make sure there is no interference. Make sure everything works properly, i.e. if the signals come from the correct speaker paths (high signals from the tweeters, bass signals from the bass speaker). Turning down the input level controls may not always prevent distortions in the input section of the power amplifier, especially if this section has a relatively low headroom. A clipping signal may not be displayed by the clipping indicator then! To prevent signal interruptions caused by protection circuits or damages to the speakers, turn the level controls of the power amplifier to the maximum position, if possible. Only turn up the signal level at the mixing console or on the controller far enough so that the power amplifiers are not overloaded; or reduce the limiter threshold. When turning off the system, the input controls for the power amplifiers should be turned down first followed by the power switches of the amplifiers. After that, the other appliances can be turned off. Page 14 of 19

8. Technical Specifications CP+ I/O Analog ports 4x Analog INPUT 1 to 4, 4x Analog LINK 1 to 4 AES/EBU Inputs 2 INPUT ports (1/2, 3/4), 2 LINK ports (1/2, 3/4), direct wiring DANTE/REMOTE (network) 2 RJ-45 EtherCon ports (primary and secondary ports), 100/1000BaseT compliant (for Ethernet / IP connection) Dimensions and Weight Dimensions (W x H x D*) 2 RU rack mount, 483 x 88 x 168 mm Weight 2.7 kg Page 15 of 19

9. EC Declaration of Conformity Page 16 of 19

10. Disposal Please recycle the packaging material of the device. 10.1 Germany Don t dispose of waste electrical equipment through household waste. Don t deliver it to official recycling points either. All KLING & FREITAG products are plain business-to-business (B2B) products. Therefore, KLING & FREITAG GmbH is exclusively responsible for disposing of all KLING & FREITAG waste equipment marked with a garbage-can icon. Please call the below phone number when you have a KLING & FREITAG product (marked with the garbage-can icon) for disposal. We will offer you a straightforward and professional disposal at no cost. KLING & FREITAG equipment with no such icon was sold before 24 March 2006; in that case, the owner is legally responsible for disposal. We will, however, gladly assist you by naming appropriate ways of disposal. For further disposal information of KLING & FREITAG waste products, call +49 (0)511-96 99 7-0 Background information: The Electrical and Electronic Equipment and Appliances Act (ElektroG) is the German implementation of the European (EU) Waste Electrical and Electronic Equipment Directive (WEEE, 2002/96/EC). Therefore, starting on 24 March 2006, KLING & FREITAG GmbH has marked all products subject to the WEEE that are distributed in Germany with an icon showing a crossed-out garbage can with a white bar below it. The icon indicates that the equipment was distributed on or after 24 March 2006 and must not be disposed of through household waste. KLING & FREITAG GmbH is legally registered as a manufacturer with the German wasteequipment registration authority (EAR). The WEEE registration number is: DE64110372. We substantiated towards the EAR that our products are for B2B trade only. 10.2 EU, Norway, Iceland, and Liechtenstein Don t dispose of waste electrical equipment through household waste. Starting on 13 August 2005, KLING & FREITAG GMBH has marked all products subject to the WEEE directive that are distributed in any member state of the European Union (except Germany), Norway, Iceland, or Liechtenstein with an icon showing a crossed-out garbage can with a white bar below it. The icon indicates that the equipment was distributed on or after 13 August 2005 and must not be disposed of through household waste. Unfortunately, the European WEEE directive was implemented in different national legislation in the EU member states, making it impossible to offer a consistent disposal solution throughout Europe. The local distributor (sales partner) in the respective country is responsible for complying with the applicable legislation. Contact your retailer or the local authorities for information on the regulations applicable in any EU member state (except Germany). Page 17 of 19

10.3 All Other Countries Contact your retailer or the local authorities for information on the regulations applicable in any country not listed above. Page 18 of 19

INDEX AES/EBU...8 Connection...9 Disposal... 17 EC Declaration of Conformity... 16 First-time Use...14 Functions... 6 I/O... 6 Safety Instructions... 5 Technical Specifications...15 Wiring...8 Page 19 of 19