DATA SHEET IOM 200 analogue interface for AGC 200

Similar documents
Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Engine Control Unit, ECU 100 Engine control Engine monitoring and protection Easy-to-read graphical display Integrated emulation software solution

Generator Protection Unit, GPU-3 Gas Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

Generator Paralleling Controller, GPC-3 Gas Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

AGC 200 Advanced Gen-set Controller DATA SHEET

Generator Protection Unit, GPU-3 DATA SHEET

Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

Generator Protection Unit, GPU-3 DATA SHEET

Generator Paralleling Controller, GPC-3 Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

DATA SHEET Paralleling and Protection Unit, PPU-3

Generator Paralleling Controller, GPC-3 DATA SHEET

DATA SHEET. AGC PM Automatic Genset Controller, Plant Management

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

DATA SHEET DEPRECATED - PCM5 1. Document no.: N/A

DATA SHEET Compact Genset Controller, CGC 200

DATA SHEET Genset Controller, GC-1F

DATA SHEET Selectable AC transducer, TAS-331DG

INSTALLATION INSTRUCTIONS

PPU Power Management (PPM)

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

Automatic Sustainable Controller, ASC Mounting Board slot positions Terminal strip overview I/O lists Wiring

DATA SHEET Selectable AC transducer, TAS-321 DG

AGC 200 Automatic Advanced Gen-set Controller DATA SHEET

Engine Controller EC-1

Automatic Gen-set Controller Multi-line D

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Generator Controller GC-1F

Generator Controller GC-1

MIC-2 Multi-instrument DATA SHEET

No longer for sale. Generator Controller GC-1. Data sheet. Standard functions

Basic Gen-set Controller multi-line F SW version 2.31.X or later

DATA SHEET Automatic Genset Controller, AGC-3

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

SPARE PART ONLY. Basic Gen-set Controller Multi-line H SW version 2.31.X or later. Data sheet. Standard functions

INSTALLATION INSTRUCTIONS

DATA SHEET Rudder/azimuth angle Transmitter CAN, RTC 300/RTC 600

MIC-2 MKII, Multi-instrument DATA SHEET

DEIF A/S. Generator Paralleling Controller multi-line L. Type GPC / GS. Compact system in one unit

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

PPM Protection and Power Management DATA SHEET

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Electronic timer CT-ERD.12

DATA SHEET Advanced Graphical Interface, AGI 100 series

Option X4 Additional Operator Panel AOP-2 Description of option Functional description

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Installation Manual. Multi Power Controller MPC-1 multi-line D

VEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

VEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

Electronic timer CT-ARS.11

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Delomatic 4, DM-4 Marine & Offshore DATA SHEET

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

Electronic timer CT-ERS.21

Electronic timer CT-AHD.22

PHOENIX CONTACT Features

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

AI561 Analog Input Module

EM2020 Selectable AC transducer A (UK)

MINI-PS AC/10-15DC/8

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

DI572 Digital Input Module

Power supply CP-E 48/1.25 Primary switch mode power supply

AO561 Analog Output Module

Delomatic 4, DM-4 Land DATA SHEET

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

Zelio Control-modular measurement and control relays 1

DATA SHEET Automatic Genset Controller, AGC-4

Power supply CP-E 24/0.75 Primary switch mode power supply

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

DATA SHEET Advanced Graphical Interface, AGI 100 series

DATA SHEET Applicable for offshore or nearshore

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Switched-Mode Power Supplies. 5, 12, 18, 48 VDC Output

DC561, digital input/output module,

Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Faults on the system Proximity switch connection technology:

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

DI561 Digital Input Module

PGR-3200 MANUAL INSULATION MONITOR

Power supply CP-E 24/10.0 Primary switch mode power supply

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

BACnet/IP Web Interface

DC562, digital input/output module,

RM35TF V AC

DATASHEET. Ultra Capacitor Charger, UCC-4

Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

Transcription:

DATA SHEET IOM 200 analogue interface for AGC 200 CAN interface to AGC 200 series TTL interface to PC LED indicators for unit and CANbus status GOV/AVR outputs selectable for DC current or DC voltage DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615 info@deif.com www.deif.com Document no.: 4921240366B SW version: 3.5x.x or later

1. General Information 1.1. Application and overview...3 1.1.1. Application...3 1.1.2. Overview...3 1.1.3. Status LEDs...3 1.1.4. DIP switches...4 1.1.5. PC interface...4 1.1.6. CANbus interface...4 1.1.7. Terminals...5 2. Technical Information 2.1. Connections...6 2.1.1. CANbus connections...6 2.2. Technical specifications...7 2.2.1. Available variants...7 2.2.2. Specifications...8 2.2.3. Unit dimensions in mm (inches)...9 3. Ordering Information 3.1. Order specifications and disclaimer...10 3.1.1. Order specifications...10 3.1.2. Disclaimer...10 DEIF A/S Page 2 of 10

General Information 1. General Information 1.1 Application and overview 1.1.1 Application The IOM 200 series is intended to be used as an interface between the AGC 200 product family and governors with an analogue interface. It can be used as an interface to other controllers if analogue load sharing lines are required, e.g. when adding generators to an existing system. 1.1.2 Overview IOM 220 CANbus interface TTL interface to PC Analogue governor interface 0-20 ma governor signal +/- 25 ma governor signal 0-10V DC governor signal +/- 12V DC governor signal Analogue AVR interface 0-20 ma AVR signal +/- 25 ma AVR signal 0-10V DC AVR signal +/- 12V DC AVR signal Unit status GOV sel. GOV adj. AVR adj. AVR sel. 4 1 4 1 1 2 3 4 5 6 7 8 9 10 11 12 13 14 IOM 230 Same as IOM 220 with additional: Analogue load sharing and VAr load sharing Interface ( -5... 0... +5V DC) CAN status Not used PC port 1.1.3 Status LEDs The status LEDs are 2-coloured Green Red System OK Fail DEIF A/S Page 3 of 10

General Information 1.1.4 DIP switches Output selections for governor/avr PCB ON OFF Output SW 1 SW 2 SW 3 SW 4 +/-25 ma ON OFF OFF 0-20 ma OFF ON OFF NOT USED +/-12V DC ON OFF ON 0-10V DC OFF ON ON The V DC signal levels can adjusted via the potentiometers SW 1 and SW 2 cannot have the same position Output resolution is 1024 steps, regardless of selected range 1.1.5 PC interface The TTL PC interface is intended for connection via option J5 (RS232 to TTL converter cable) and can be used for downloading new firmware updates only. 1.1.6 CANbus interface The CANbus interface to the AGC 200 has automatic address selection and can be connected to the AGC 200 CAN line A, B or C. DEIF A/S Page 4 of 10

General Information 1.1.7 Terminals IOM 200 1 2 3 4 5 6 7 8 9 10 11 12 13 14 + 12/24 V DC Power supply - Not used Out Interface to governor Com Out Interface to AVR Com Not used var load sharing line Com IOM 230 only Power load sharing line Terminal Description Comment 1 +12/24V DC Power supply 2 0V DC 3 Not used 4 5 CAN- CANbus interface to AGC 200 6 7 GOV out Governor analogue interface 8 GOV com 9 AVR out AVR analogue interface (IOM 220 and 230) 10 AVR com 11 Not used 12 VAr share out 13 Common Load sharing lines (IOM 230) 14 P share out DEIF A/S Page 5 of 10

Technical Information 2. Technical Information 2.1 Connections 2.1.1 CANbus connections The CANbus connection can be "point-to-point" between an IOM 200 module and an AGC 200, or "multidrop" between an AGC 200, IOM 200 and an engine controller. Please refer to the application notes "IOM 200 analogue interface for AGC 200", document no. 4189340614. Point-to-point IOM 2xx 4 5 6 R CANbus end terminal resistor R = 120 Ω R AGC 200 7 8 9 10 11 12 13 14 15 CAN A CAN B CAN C Multidrop ENGINE CONTROLLER IOM 2xx AGC 200 R 4 5 6 13 14 15 CAN C R CANbus end terminal resistor R = 120 Ω In both cases, the cable shield must NOT be connected to ground, only to the terminal of the DEIF units. In multidrop, the cable shield must NOT be connected to the engine controller unless it is absolutely certain that the engine controller CANbus connection is galvanically isolated from the rest of the controller. DEIF A/S Page 6 of 10

Technical Information 2.2 Technical specifications 2.2.1 Available variants Type Variant Description Item no. Note IOM 200 01 IOM 220 2912890200-01 AVR and GOV output IOM 200 02 IOM 230 2912890200-02 AVR and GOV output loadshare lines DEIF A/S Page 7 of 10

Technical Information 2.2.2 Specifications Operating temperature Storage temperature -40...70 C (-40...158 F) UL/cUL Listed: Max. surrounding air temperature: 55 C (131 F) -40...70 C (-40...158 F) Climate 97% RH to IEC 60068-2-30 Aux. supply Mounting Safety 8.5-36V DC continuously (UL/cUL: 8.5...32.7V DC) Max. 4 W consumption The aux. supply input is to be protected by a 2 A slow-blow fuse (UL/cUL listed: AWG 24) DIN rail To EN 61010-1, installation category (overvoltage category) III, 300V, pollution degree 2 Protection IP20/NEMA type 1 to IEC/EN 60529 EMC/CE To EN 61000-6-1/2/3/4 IEC 60255-26 IEC 60533 power distr. zone IACS UR E10 power distr. zone Vibration 3...13.2 Hz: 2mm pp 13.2...100 Hz: 0.7 g To IEC 60068-2-6 To IACS UR E10 10...60 Hz: 0.15mm pp 60...150 Hz: 1 g To IEC 60255-21-1 Response (class 2) Shock 10..150 Hz: 2 g To IEC 60255-21-1 Endurance (class 2) 10 g, 11 msec, half sine To IEC 60255-21-2 Response (class 2) Bump Material 30 g, 11 msec, half sine To IEC 60255-21-2 Endurance (class 2) 50 g, 11 msec, half sine To IEC 60068-2-27 20 g, 16 msec, half sine to IEC 60255-21-2 (class 2) All plastic materials are self-extinguishing according to UL 96 (V1) Connections 3.5 mm 2 (13 AWG) multi-stranded service port: TTL, RJ 12 DEIF A/S Page 8 of 10

Technical Information Tightening torque (min) Approvals UL markings Mounting Weight 0.5 Nm (5-7 lb-in) UL/cUL Listed to UL508 UL/cUL Recognized to UL2200 Wiring: Use 60/75 C copper conductors only For DIN rail mounting inside a cabinet Main disconnect must be provided by installer Installation: To be installed in accordance with the NEC (US) or the CEC (Canada) 0.3 kg (0.7 lbs) 2.2.3 Unit dimensions in mm (inches) 73 (2.87) 59 (2.32) 42 (1.65) 34 (1.34) 125 (4.92) 155 (6.10) DEIF A/S Page 9 of 10

Ordering Information 3. Ordering Information 3.1 Order specifications and disclaimer 3.1.1 Order specifications Variants: Mandatory information Item no. Type Variant no. Example: Mandatory information Item no. Type Variant no. 2912890200-01 IOM 220 01 3.1.2 Disclaimer DEIF A/S reserves the right to change any of the contents of this document without prior notice. DEIF A/S Page 10 of 10