Configuring Platform Event Filters

Similar documents
Configuring Platform Event Filters

Configuring Platform Event Filters

Viewing Faults and Logs

GIGABYTE Remote Management Console User s Guide. Version: 1.0

Configuring Communication Services

Integrate APC Smart UPS

BMC v User Manual

Security Management System SNMP Trap Interface

The operator has activated this LED to identify this chassis. This chassis is not being identified. Fabric modules are all operational.

Troubleshooting the Cisco RPS

Proprietary MIB Reference

Dell EMC OpenManage Message Reference Guide. Version 9.1

TFC-1600MM Media Conversion System. Management Configuring Guide

DMC SNMP Module for Chassis-Based Media Converter Manual. Rev. 01 (JUN. 2002) 1907MCB RECYCLABLE

Server Administrator Version 8.5 Messages Reference Guide

Call Home and Smart Call Home Configuration

Notice for Express Report Service (MG)

Server Administrator Version 7.4 Messages Reference Guide

DGS-1510 Series Gigabit Ethernet SmartPro Switch Web UI Reference Guide. Figure 10-1 Cable Diagnostics window

Quick Guide. Extra Communication Card

Hardware Events Alerting on Dell Servers IPMI PET Applied

Configuring the Embedded Event Manager

Configuration Import/Export

UCS-E160DP Double-wide E-Series Server, 6 core CPU, with PCIe

SNMP Notifications. SNMP Notifications. Description of the SNMP notifications sent by the UBIqube SOC 1 / 7

Cyclone Microsystems PCIe Chassis Monitor User s Manual P/N CM026

Rack Management Controller. User Manual

Checking System Status General Steps

Configuring GX7 to deliver SNMP traps

Intel Simple Network Management Protocol (SNMP) Subagent v8.0

Advanced Monitoring of Dell Devices in Nagios Core Using Dell OpenManage Plug-in

This document describes troubleshooting techniques for the Nexus 7000 (N7K) hardware.

Administrator s Guide

Extra Communication Card Quick Start Guide

Environmental monitoring of any facilities, control of security breaches, temperatures, smoke, water leakages, voltages and more.

Managing the Server. You must log in with user or admin privileges to perform this task. Command or Action

Troubleshooting. Diagnosing Problems

User s Manual. Management Converter Chassis. Model No.: SP1386 / SP1387. World Wide Web: ;

Nexio IconStation SNMP Support

Command Manual MAC Address Table Management H3C S5500-EI Series Ethernet Switches. Table of Contents

Modbus Map: Automatic Generator Start (AGS) Device

Dell EMC Server Management Pack Suite Version 7.0 for Microsoft System Center Operations Manager. User's Guide

Chassis-based Media Converters

Configuring sflow. Information About sflow. sflow Agent. This chapter contains the following sections:

PDU Utility. User Manual

Configure Notifications

Dell Server Management Pack Suite Version 6.1 for Microsoft System Center Operations Manager User's Guide

Cisco Remote PHY Fault Management

Monitoring the System

Managing Events and Alarms

Management Console User s Guide (AST 2500 Chipset)

Cisco RF Switch Firmware Command Reference Guide

L2+ 24-Port Gigabit Managed Switch with. Hardware Layer3 IPv4/IPv6 Static Routing GS S8C GS S8CR. Quick Installation Guide

Index. B Boot software 5-2 Bridging architecture 7-6 Broadcast filter 8-55 limiting 8-22 Buffer port 7-9 Syslog 8-17, 8-20

Optidrive Applications Support Library

CONFIGURING SYSTEM EVENT ALERT NOTIFICATIONS FOR EMC KAZEON RUNNING ON INTEL PLATFORM

One of the following problems exist: At least one power supply LED is red. At least one power supply is down. Fan trays are all operational.

Table of Contents SMARTZONE G5 USER MANUAL

NEC ESMPRO AlertManager User's Guide

Lab 6-3 Configuring a Wireless Client

SEI DC-UPS Power Management Package Users Manual

Power Supply SNMP Interface User manual

Cordex Controller Software v2.15

Embedded Event Manager System Events and Configuration Examples

Power Supply SNMP Interface User Manual

Server-Related Faults

Configuring System Message Logs

Ethernet Port Configuration Mode Commands

Network Management Card. User Manual

Smart PDU Utility. User Manual

Getting Started with Notifications

Dell PowerEdge C410x. Technical Guide

CP30/G30/MC31 Firmware Service Update Version 2993 (19 Aug 2013) Release Notes

Device Management Basics

Mobility Services CAS. wips CHAPTER

Table of Contents SMARTZONE G5 USER MANUAL

ERX System Overview. The ERX System. This chapter provides information about the system.

NEC ESMPRO AlertManager User's Guide (Windows)

RS-232 Port Configuration Mode Commands

Monitoring Notifications

Cisco UCS C-Series Servers Integrated Management Controller CLI Configuration Guide, Release 1.0(1)

Using the Baseboard Management Controller

Configuring System Message Logs

Network Management Card 2 (NMC 2) Firmware v6.5.6 for Smart-UPS and Single-Phase Symmetra Release Notes

Monitoring Juniper EX Switch

ThinkSystem SR650 Messages and Codes Reference

Management Software. SmartView TM EMS (Element Management System) 1-1. Management Software. Polled Network Elements

Management Software. SmartView TM EMS (Element Management System) Management Software. Management Software. Polled Network Elements

IPMI View User Guide

Application Notes for TONE Software ReliaTel Fault and Performance Management 4.6 with Avaya Aura Communication Manager 7.0 using SNMP Issue 1.

Configuring System Message Logs

PDU Utility User Manual Version 3.1

HP StorageWorks P2000 G3 MSA System Event Descriptions Reference Guide

Network Management Card. User Manual

BITS Port Configuration Mode Commands

Vmware VCP550PSE. VMware Certified Professional on vsphere 5.

PDU Utility. User Manual

Troubleshooting Tools. Tools for Gathering Information

DS1810 5V EconoReset with Push-Pull Output

Dell Chassis Management Controller for Dell EMC PowerEdge FX2 Version 2.0. Release Notes

Transcription:

This chapter includes the following sections: Platform Event Filters, page 1 Enabling Platform Event Alerts, page 1 Disabling Platform Event Alerts, page 2, page 2 Configuring SNMP Trap Settings, page 4 Platform Event Filters A platform event filter (PEF) can trigger an action and generate an alert when a critical hardware-related event occurs. For each PEF, you can choose the action to be taken (or take no action) when a platform event occurs. You can also choose to generate and send an alert when a platform event occurs. Alerts are sent as an SNMP trap, so you must configure an SNMP trap destination before the alerts can be sent. You can globally enable or disable the generation of platform event alerts. When disabled, alerts are not sent even if PEFs are configured to send them. Enabling Platform Event Alerts Server /fault # set platform-event-enabled yes Server /fault # commit Enables platform event alerts. Commits the transaction to the system OL-21105-01 1

Disabling Platform Event Alerts Server /fault # show [detail] (Optional) Displays the platform event alert The following example enables platform event alerts: Server /fault # set platform-event-enabled yes Server /fault *# commit Server /fault # show SNMP Community String Platform Event Enabled --------------------- ----------------------- public yes Server /fault # Disabling Platform Event Alerts Server /fault # set platform-event-enabled no Server /fault # commit Server /fault # show [detail] Disables platform event alerts. Commits the transaction to the system (Optional) Displays the platform event alert The following example disables platform event alerts: Server /fault # set platform-event-enabled no Server /fault *# commit Server /fault # show SNMP Community String Platform Event Enabled --------------------- ----------------------- public no Server /fault # You can configure actions and alerts for the following platform event filters: ID 1 2 Platform Event Filter Temperature Critical Assert Filter Temperature Warning Assert Filter 2 OL-21105-01

ID 3 4 5 6 7 8 9 10 11 12 13 14 Platform Event Filter Voltage Critical Assert Filter Voltage Warning Assert Filter Current Assert Filter Fan Critical Assert Filter Fan Warning Assert Filter Processor Assert Filter Power Supply Critical Assert Filter Power Supply Warning Assert Filter Power Supply Redundancy Lost Filter Discrete Power Supply Assert Filter Memory Assert Filter Drive Slot Assert Filter Server /fault # scope pef id Server /fault/pef # set action {none reboot power-cycle power-off} Server /fault/pef # set send-alert {yes no} Enters the platform event filter command mode for the specified event. See the Platform Event Filter table for event ID numbers. Selects the desired system action when this event occurs. The action can be one of the following: none An alert is sent but no other action is taken. reboot An alert is sent and the server is rebooted. power-cycle An alert is sent and the server is power cycled. power-off An alert is sent and the server is powered off. Enables or disables the sending of a platform event alert for this event. OL-21105-01 3

Configuring SNMP Trap Settings Step 5 Server /fault/pef # commit Note For an alert to be sent, the filter trap settings must be configured properly and platform event alerts must be enabled. Commits the transaction to the system This example configures the platform event alert for an event: Server /fault # scope pef 13 Server /fault/pef # set action reboot Server /fault/pef *# set send-alert yes Server /fault/pef *# commit Server /fault/pef # show Platform Event Filter Event Action Send Alert --------------------- --------------------------- ----------- ------------------ 13 Memory Assert Filter reboot yes Server /fault/pef # What to Do Next If you configure any PEFs to send an alert, complete the following tasks: Enable platform event alerts Configure SNMP trap settings Configuring SNMP Trap Settings Server /fault # set community-str string Enter the name of the SNMP community to which trap information should be sent. Step 5 Server /fault # scope trap-destination number Server /fault/trap-destination # set enabled {yes no} Server /fault/trap-destination # set addr ip-address Enters the SNMP trap destination command mode for the specified destination. Four SNMP trap destinations are available. The destination number is an integer between 1 and 4. Enables or disables the SNMP trap destination. Specifies the destination IP address to which SNMP trap information is sent. Step 6 Server /fault/trap-destination # commit Commits the transaction to the system 4 OL-21105-01

Configuring SNMP Trap Settings This example configures the SNMP trap destination: Server /fault # set community-str public Server /fault *# scope trap-destination 1 Server /fault/trap-destination # set enabled yes Server /fault/trap-destination *# set addr 10.20.30.41 Server /fault/trap-destination *# commit Server /fault/trap-destination # show Trap Destination IP Address Enabled ---------------- ---------------- -------- 1 10.20.30.41 yes Server /fault/trap-destination # OL-21105-01 5

Configuring SNMP Trap Settings 6 OL-21105-01