Installation & Operation Guide

Similar documents
Installation & Operation Guide

Installation & Operation Guide

BAC-9000 Series VAV Controller Installation Guide

Installation and Operation Guide

Installation and Operation Guide

Installation and Operation Guide. BAC-5841/5842 UFAD and BAC / VAV Advanced Application Controllers, 8 x 8

Installation and Operation Guide. KMD 5559 CommTalk

Custom Controller Installation Instructions

TPE 1464 Series Pressure Transducer

PROLON INSTALLATION AND START UP GUIDE

PP-8516 & PP Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

7" Touch Screen Display

N20, N34 Series Non-Spring Return Direct Coupled Actuators

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

TRC-190 User s Manual

EP/2 Installation Instructions

THE CTB08D LIGHT CONTOLLER

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

XT-9100 Technical Bulletin

K10 Intrinsically Safe Electro-Pneumatic Positioner Operating Manual

Installation Guide (3/6 Outputs)

MONITOR Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

ETM-2050/ETM-2051 Service Manual

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

VAV Modular Assembly (VMA) 1410/1420

N20010-SER. NON-SPRING RETURN DAMPER ACTUATOR 20 Nm (177 lb-in) FOR ADJUSTABLE MODULATING CONTROL SPECIFICATIONS GENERAL FEATURES PRODUCT DATA

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

SimplyVAV Application and Installation Guide

Research Concepts RC2500 Antenna Interface Unit (AIU) Board Set

TRC-190 User s Manual

TOXALERT MODEL AIR 2000

T7560A1036 Digital Wall Module

LNX Series Motor and Drives

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

6222 Two Door Module Technical Operations Manual

M1000 INTELLIGENT ZONE CONTROL SYSTEM

SCC5-RM. Coloronix, Inc West Jefferson Boulevard Los Angeles, California (323)

POWER Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Vision OPLC V TR6/V350-J-TR6

SQM5 Reversing Actuators, with Multiple Analog Control Input Signals

TEC VAV with 0-10V AO Heat. Modulation and CO2 Monitoring. Controller. Control Applications. Product Description. Accessories.

Installation and Configuration Guide

OilCop Component Wiring Installation Manual

BACnet PTEC Terminal Box (VAV) Controller. Control Applications. Product Numbers. Product Description. Warning/Caution Notation

CA-A480-A Elevator Controller. Reference & Installation Manual

The Infinity TCX 865 programmable Infinet terminal controller is a unique, low-cost VAV box

This guide provides basic information for Unitronics controller model V T2.

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

Rev Cutler-Hammer Smart Breaker Panel Control Manual

SNAP-IT-1U Installation Guide

HVG400. Installation Guide

EX-RC1 Remote I/O Adapter

DWYER INSTRUMENTS, INC. Series AVUL Air Velocity Transmitter. Specifications - Installation and Operating Instructions.

Ethernet Adapter Installation Instructions

DC425 NEMA 4X Analog Output Transducers

COMMERCIAL. VAM24-90-(A) Series

NSD/M1 Installation Instructions

SQM5 Reversing Actuator with Analog Input Signal

MAXIMA + Series ROTARY LEVEL CONTROL

Application Engineering

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

Infosystem Remote Touchscreen Installation Instructions

MAXIMA+ Series Rotary Level Indicator

Contents. Please read and remember the following warnings before using the RELAYplate:

OPLC Installation Guide

TECH/DATA SHEET. Application. Model Chart. Installation. slon-v1. slon-v2. slon VAV Controller

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

OZONE SWITCH Model OS-6. OS-6 Features

VAV compact controller GDB181.1E/3 GLB181.1E/3

Resolver to Digital Expansion Board

T7560A,B,C Digital Wall Module

MAXIMA + Series ROTARY LEVEL CONTROL

N05, N10 SERIES NON-SPRING RETURN DIRECT-COUPLED DAMPER ACTUATORS FOR MODULATING AND FLOATING CONTROL

Functional data Communicative control Cloud: (call for clientapi ) Angle of rotation 90

D1V Rotary Control Panel D4S Button Panel PS Power Distribution Module USER MANUAL

Installation Guide. Room Temperature Sensors. Mounting. Location and Cover Removal (All) STE-6011 Only. STE-6010/6013/6015 Only

ANT CNTR DC ALRM LNB RX DC ALRM +18V OFF

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

2Installation CHAPTER TWO IN THIS CHAPTER. Checking Your Shipment Express Setup. Chapter 2 Installation 11

Installation Instructions

Installation OVERVIEW

ETM-2040 Service Manual

VM 6.1. Capacitive Air Gap Measuring Chains User s Manual P/N: M7A-110

Series F75 Fail-Safe Module Installation, Operation and Maintenance Instructions

Electrical Demand Specification (Reference SOP: )

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

Rapier Series Switch Quick Install Guide

clarity 3 VAV Programmable Controller

IRB-RET O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Installation and Operation Instructions I/CO 2, I/CO 2 -VDC, I/CO 2 -T

2M IR Mini Dome Quick Installation Guide

Specification Sheet For electronically commutated motors

VFC. Operating manual TROX air terminal units Type VFC volume flow controllers. General information 2. VFC series volume flow controllers

TEC Terminal Box (VAV) Controller

RE-82 RACK MOUNT DIMMER OWNERS MANUAL. 8 X 2400Watts. Revision /29/2007

NCH-1000 (Multiple Breaker Types) Installation Instructions

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

ST400C-NT USER S GUIDE. Table of Contents

Digital Lighting Systems, Inc.

Transcription:

Installation & Operation Guide Direct Digital VAV Controllers KMD-7001/7051 - VAV Terminal Units KMD-7002/7052 - Dual Duct VAV Units KMD-7003/7053 - Fan Induction Units 907-019-01C 1

Introduction This section provides a brief overview of the KMD-7001, 7002 and 7003 Direct Digital Controllers. These units are intended for use with standard 1/2 round or 3/8 square damper shafts. Note: For installations using a 3/8 round shaft, you will need the HFO-0011 shaft adaptor. Review this material before you attempt to install the controller. Non-Rotational Bracket Gear Disengagement Button Air Sensor Inputs Conduit Plugs Lock Tab Status LEDs Removable Conduit Plate Drive Hub Access Cover Illustration 1. Controller Components The following illustrations show the different model connection details. Isolation Lamps Input/EOL Switches RST Jumper RJ-12 Conn. Network Switch Power Jumper Conduit Plate Terminal Connections Lock Tab Illustration 2. KMD-7001 Controller Connector Detail 2

RJ 12 Conn. Isolation Lamps Input/EOL Switches RST Jumper Network Switch Terminal Connections Lock Tab Conduit Plate Power Jumper Illustration 3. KMD-7002 Controller Connector Detail Isolation Lamps Input/EOL Switches RST Jumper RJ 12 Conn. Network Switch Power Jumper Terminal Connections Lock Tab Conduit Plate Illustration 4. KMD-7003 Controller Connector Detail Installation This section provides important instructions and guidelines for installing the KMD-7001, 7002 and 7003 series controllers. Carefully review this information prior to attempting installation. Preparation Prior to mounting the controller, the rotational limits must be set using stop pins. These settings limit the shaft rotation in the clockwise (CW) and counterclockwise (CCW) directions. (Refer to Illustration 5.) 3

Installation KMD-7001/7002/7003 Direct Digital Controller Installation & Operation Guide Stop Pin (1 of 2) Stop Selections Illustration 5. Controller Stop Selections To set the rotational limits: 1. Turn the controller over so you have access to the back. 2. Locate the two stop pins installed in the back of the unit. (You will find one pin in a CCW setting and one in a CW setting.) 3. Identify the limits you wish to use. The maximum amount of shaft rotation is 90. Placing a stop pin in both 90 slots allows the actuator the full 90 of travel. Placing a stop pin in any other slot restricts actuator motion in the indicated direction (CW or CCW). Refer to Illustration 6 for pin placement and travel. The first number represents the CCW pin and the second the CW pin (CCW/CW). 90/90 60/90 45/90 90/60 90/45 90/45 4 60/60 45/60 60/45 Illustration 6. Controller Travel and Stop Selections

KMD-7001/7002/7003 Direct Digital Controller Installation & Operation Guide Installation Caution Both stop pins must be installed to prevent actuator damage. Mounting 4. If the stop pins are positioned as required, you may leave them in place. If not, remove the appropriate pin(s) and place it in the correct slot. The controller will be mounted directly over the damper shaft. A minimum shaft length of 1-3/4 (45 mm) is required. The base of the controller must contact the mounting surface to allow installation of a bracket to prevent the controller from rotating. Note: The controller should be mounted close enough to the Pitot tubes to allow a maximumn 24 length of tubing to reach the controller inputs. Proceed as follows: 1. Back out the set screws in the shaft collar so the shaft can fit through the collar. 2. Place the controller on the damper shaft in the approximate final position. 3. Position the non-rotation bracket and secure it using #8 or #10 self-tapping screws. Make certain the notch in the bracket securely engages the Lock tab on the controller. (Refer to Illustration 1.) 4. Manually position the damper in the full open position. 5. Adjust the drive hub as follows: A. If the damper rotates counter clockwise to close, depress the gear disengagement button and rotate the drive hub to the full clockwise position then release the button. B. If the damper rotates clockwise to close, depress the gear disengagement button and rotate the drive hub to the full counter clockwise position then release the button. 6. Tighten the two set screws in the drive hub to approximately 50 inch pounds (5.65 N-m) to lock the hub to the shaft. Wiring The controller comes with a removable conduit plate. The plate provides two 1/2 female threaded conduit couplings. If conduit is to be used, note the following: The conduit plate may be removed by removing the two screws that secure the access cover and removing the cover. Connect the required conduit and replace the plate in the controller housing. The plugs may also be sliced to allow wiring to enter the controller with a minimum of outside contaminates. 5

Installation KMD-7001/7002/7003 Direct Digital Controller Installation & Operation Guide Input Connections Universal Inputs RS-485 Inputs All input and output connections are made using the connectors beneath the access cover. Remove the two screws that secure this cover to remove the cover and complete input and output connections as discussed below. Inputs are configured per the model. 7001/7051 and 7003/7053 Inputs are connected to the wire terminal strip using connections I1 I3. Observe the following guidelines. (Refer to Illustration 2 and 4.) Connect device inputs to the input terminal connections for inputs I1 I3. Connect all grounds to the common GND reference terminals. If input pull-ups are required, refer to Board Configuration later in this section. Note: Input #1 (I1) is typically assigned to the space temperature sensor input, otherwise it is available for use. Inputs 2 and 3 are available for optional inputs. 7002/7052 These inputs are the same as on the 7001/7003 series except for Input #3 (I3). The I3 input on these models is dedicated to the TSP Slave Flow Sensor input. (Refer to Illustration 3.) To make connections to a KMC Tier 2 (RS-485) network use the RS-485 connections on the terminal strip. If the Controller is at the End-of-Line, refer to Configuration after connections are completed. Detail The End-of-Line connection will have only one wire attached to the A and B terminals. For reliable operation, use Belden cable model #82760 or equivalent (18 gauge, twisted, shielded, 50 picofarads or less) for all network terminal block connections. Connect the nodes of the network in a daisy-chain arrangement. This means: Connect the A terminal in parallel with all other A terminals. Connect the B terminal in parallel with all other B terminals. Connect the shields of the cable together at each controller. Connect the shield drain wire to an earth ground only at one end of the segment; tape back the shield ground at the other end. 6

KMD-7001/7002/7003 Direct Digital Controller Installation & Operation Guide Installation Airflow Sensor Connecting Outputs RJ-12 An Airflow Sensor is incorporated as one of the inputs to the controller. Remove the plugs and connect the tubing from the Pitot assembly to the airflow sensor inputs above the drive hub. (Refer to Illustration 1.) The Controller provides three output connection options configured according to the model. Locate your model from the units discussed below: 7001/7051 and 7002/7052 These models provide three universal outputs O1, O2 and O3. They will provide 0/12 VDC at a maximum of 50 ma in Digital mode or 0-10 VDC at a maximum of 30 ma in Analog mode. Returns are connected to the GND connections on the left end of the strip. (Refer to Illustration 2 and 3.) 7003/7053 Board Configuration These models are unique as described below: (Refer to Illustration 4.) Out 1 This is a universal output that may be used as an output option. Output ratings are the same as on the other models. T2 This Triac output will switch a maximum voltage of 30 VAC. It is rated for a minimum current of 20 ma and a maximum of 1A. Use the RET terminal for the triac return. R3 This output is assigned as the Normally Open Relay Output. The output will switch up to 30 VAC/DC at up to 2A maximum. The return connects to the COM terminal. An RJ 12 connector is provided for connection to the KMD-1001 NetView or the KMD-11xx Series NetSensor or a PC. Simply place the appropriate cable connector in the provided RJ 12 connector and connect the other end to the device. Configuration settings may be required for the inputs or the RS-485 connection. If you must activate or deactivate pull-ups on the inputs or set the end-of-line termination for the RS-485 connection, refer to Illustration 7 to locate the switches for these settings. 7

Installation KMD-7001/7002/7003 Direct Digital Controller Installation & Operation Guide RJ 12 Conn. Input Pull-Up/EOL Switches Power Connection Illustration 7. Typical Input Pull-up and EOL Switch Placement Proceed as follows: 1. If the access cover is still on the controller, remove the two screws that secure the cover, then remove the cover. 2. Locate the switch next to the isolation lamps behind the terminal strip. (See Illustrations 4.) 3. Set the switches as follows: A. If the RS-485 connection is the End-of-Line controller, verify that both switches 4 & 5 (A & B) are in the ON position. Otherwise, the switches remain in the default OFF position. B. If one or more inputs require a pull-up, verify that the appropriate switches (I1 I3) is set to the default ON position. For devices supplying their own voltage/current for passive devices, move the switch to the OFF position. 4. After you set the switches, replace the controller cover and secure it with the screws you removed earlier. Connect the 24 VAC supply voltage to the power terminal block on the lower right side of the controller near the PWR jumper. Connect the GND side of the transformer to the GND terminal and the AC Phase side to the AC terminal. Power is applied to the controller when the power supply (or transformer) is plugged in and the PWR jumper is in place. Illustration 7 shows a typical connection diagram for the controller. 8

Room F Min 0 Max 1 FLOW V. FCTR MIN C. FCTR MAX H L V A IR V KMD-7001/7002/7003 Direct Digital Controller Installation & Operation Guide Installation RJ-12 PC/NETSENSOR PORT ROOMTEMP KMD-7003 REHEAT FAN FROM PREVIOUS DEVICE "B" FROM PREVIOUS DEVICE "A" TO NEXT DEVICE "B" TO NEXT DEVICE "A" GND GND IN1 IN2 IN3 OUT1 T2 RET R3 COM B A GND 24VAC 120VAC STE-5013 (OPTIONAL IN PLACE A B C W B 24VAC THERMAL ACTUATOR * OF NETSENSOR) HWS 24" OF 1/4" TUBING H L READY COMMUNICATIONS SERIES FAN START CIRCUIT R FLOW SSS-1000 ARIABLE OLUME CONTROLLER KMC KMDIGITAL H KMD-7003 HWR 6-CONDUCTOR CABLE APPLICATION DRAWING FOR KMD-7003 VAV WITH FAN AND WET REHEAT NETSENSOR KMD-1151 / KMD-1171 *For electric reheat applications, use a separate 24 VAC transformer to isolate the relay through the Triac. Illustration 8. Typical KMD-7003 Application Note: Network Configuration Programming Typical Application Diagrams may be obtained by contacting KMC Controls Technical Support at 574-831-5250 or e-mail us at techs@kmccontrols.com. Prior to operating the controller, it must be configured using the Hardware Configuration Manager (HCM) application supplied with WinControl. Refer to the WinControl XL User s Manual and the KMC Digital Applications Manual for additional information. Note: All controllers on the same network must be configured for the same baud rate and each controller assigned a unique address. Refer to the KMC Digital Applications Manual for information on how to program the controller. 9

Operation Controls and Indicators Network ON/OFF Status LEDs Isolation Lamps Once configured, programmed and powered up, the controller requires very little user intervention. The following sections describe the controls and indicators found on the controller. The network ON/OFF switch is located near the RJ 12 connector. Use this switch to enable or disable the RS-485 network connection. When the switch is ON the controller can communicate on the network; when it is OFF, the controller is isolated from the network. Alternately, you may remove the Isolation Lamps to isolate the controller from the network. Two Status LEDs are located on the left side of the controller above the power connector terminal. They are used to indicate the following: Ready This LED flashes rapidly whenever the controller is operating normally. You can consider this the same as a power LED. Communications This LED indicates when the controller is transmitting over the RS-485 network connection. Two Isolation Lamps are located near the RJ 11 connector. These lamps serve three functions: Removing the lamps will open the RS-485 circuit and isolate the controller from the network. If one, or both, lamps are lit, it indicates the network is improperly phased. This means that the ground potential of the controller is not the same as other controllers on the network If the voltage or current on the network exceeds safe levels, the lamps operate as fuses and may protect the controller from damage. 10

KMD-7001/7002/7003 Direct Digital Controller Installation & Operation Guide Operation Resetting the Controller If the controller appears to be operating incorrectly, or is not responding to commands, you may need to reset the controller. Note Resetting the controller will restore the factory default configuration. It may be necessary to re-configure the controller with HCM to establish normal communications and operation. Re-programming may also be required. To reset the controller, proceed as follows. 1. Remove the two screws that secure the Access Cover, then remove the cover. 2. Locate the jumper block next to the input pull-up switches (see Illustration 8). RST Jumper Illustration 8. Reset (RST) Jumper Location 3. Power off the controller. (Remove the PWR jumper.) 4. Locate the RST pins and place a jumper across them. 5. Power up the controller. Wait until the Ready LED flashes normally. 6. Power off the controller. 7. Remove the jumper from the RST pins. 8. Replace the PWR jumper. 8. Replace the controller cover. 9. Re-configure the controller if necessary. 11

Disclaimer The material in this document is provided for information purposes only. The contents and the product(s) described herein are subject to change without notice. KMC Controls, Inc. makes no representations or warranties with respect to this document. In no event shall KMC Controls, Inc. be liable for any damages, direct or incidental, arising out of or related to the use of this document. Important Notices The KMC logo is a trademark of KMC Controls, Inc. 2003, KMC Controls, Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form by any means without the written permission of KMC Controls, Inc.Printed in U.S.A. Technical Support If you have any questions about this technical document or need additional details, please call KMC Controls technical services at 574-831-5250 or e- mail us at techs@kmccontrols.com. KMC Controls P.O. Box 497 19476 Industrial Drive New Paris, IN 46553 U.S.A. TEL: 574.831.5250 FAX: 574.831.5252 E-mail: info@kmccontrols.com 12 907-019-01C