Installation / Control / Monitoring Technique

Similar documents
Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

Installation / Control Technique

H S11I1A I2A I3A I4A I5A I6A I7A I8A S21I1C I2C I3C I4C I5C I6C I7C I8C 14A I 15A I 16A 13A I 13B 14B 15B 16B M8540

H S11I1A I2A I3A I4A I5A I6A I7A I8A S21I1C I2C I3C I4C I5C I6C I7C I8C 14A I 15A I 16A 13A I 13B 14B 15B 16B M8540

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

Safety technique. Emergency-stop monitor BH 5922, BL 5922 safemaster

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6961

Safety Technique. SAFEMASTER C Multifunctional Safety Timer UG 6960

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Power Electronics. Semiconductor relay / - contactor

Safety Technique. SAFEMASTER C Multifunction Safety Module BH 5910

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

TM251MESC controller M251 Ethernet CAN

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

AI561 Analog Input Module

Safety Technique. SAFEMASTER Light Curtain Controller With Selectable Operating Modes BH 5902/01MF2

AO561 Analog Output Module

DI572 Digital Input Module

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

TM251MESC controller M251 Ethernet CAN

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

DI561 Digital Input Module

TM241CEC24R controller M IO relay Ethernet CAN master

Contact protection relay

DC562, digital input/output module,

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

DC561, digital input/output module,

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

PHOENIX CONTACT - 07/2006

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

DX561 Digital Input/Output Module

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

Datasheet - SRB 402EM-24V

TM3TI4 module TM3-4 inputs temperature

TM3AI4 module TM3-4 analog inputs

Electronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts

Datasheet - SRB 301LC/B-24V

General information. Display. Supply voltage. Input current. Encoder supply. Output current

AO523 Analog Input Module

QUINT-BUFFER/24DC/24DC/40

RIC PROGRAMMABLE INTELLIGENT CONTROLLER

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

TM3TI8T module TM3-8 inputs temperature

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

TM258LF42DT compact base M I/O - 24 V DC - CANopen

TU531, TU532 Terminal Unit

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Datasheet - SLB 200-C04-1R

TM258LF42DT compact base M I/O - 24 V DC - CANopen

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes. Input current

TM3TM3 module TM3-2 temperature inputs and 1 analog output

TF501, TF521 Terminal Bases

General information. Display. Supply voltage. Input current. Encoder supply. Output current

ILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors

Installation Instructions Temperature transmitter TAA /00 06/2011

TM221M16R controller M IO relay

TM3TI4 module TM3-4 inputs temperature

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Datasheet SRB301ST 24V (V.2)

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

Electronic timer CT-ERS.12 ON-delayed with 1 c/o contact Data sheet

HMISBC Rear Module controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

SD328AU68S2 motion control stepper motor drive - SD328 - <= 6.8 A

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

AI531 Analog Input Module

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

Electronic timer CT-ERD.12

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

TM241C40U controller M IO transistor NPN

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Electronic timer CT-ERS.21

This data sheet is only valid in association with the IL SYS INST UM E user manual.

General information. Display. Supply voltage. Input current

TM241C24T controller M IO transistor PNP

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

HMISCU6B5 3 5 color touch controller panel - Dig 8 inputs/8 outputs +Ana 4 In/2 Out

02/11/2015

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

CM592 PROFIBUS Communication Module

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current

Insulated Enclosure KS 4400 with fixed or pluggable screw or cage clamp terminals

DC522 Digital Input/Output Module

TRIO-DIODE/12-24DC/2X10/1X20

General information. Display. Supply voltage

General information. Display. Supply voltage. Input current

MINI-PS AC/10-15DC/8

TM221ME32TK controller M IO transistor PNP Ethernet

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

Electronic timer CT-AHD.22

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

Transcription:

Installation / Control / Monitoring Technique MINIMASTER CANopen PLC IL, IN 6 Your Advantages Compact CAN-operation Graphical programming Qquick and easy installation Various input- / output module digital / analogue available Circuit Diagrams CAN H R ab C C CAN L C C IL IN C CAN CAN H Rab H Rab CAN CAN CAN CAN L GND L GND M88_a IL IN CAN H R ab C CAN L C C M87_a Features According to IEC/EN 6 -, EN 78 Operation as master - Operation as slave - Transfer rate up to Mb/s - Interface according to DS version. IN locally extendable with digital and analoge in- / output modules digital inputs for DC V relay outputs LED indicators Standard programming software CODESYS under Windows according to IEC/EN 6-: - Instruction set - Ladder diagram - Function block diagram - Sequential function chart - Structured text (similar to Pascal) 8 KB Flash memory for user program 8 KB RAM for user data 6 KB battery buffered RAM for no-voltage safe data Battery buffered real time clock Monitoring contact for RUN status of the PLC IL : mm width IN :. mm width Additional Information - Data sheet Input Module IP - Data sheet Output Module IP - Data sheet Emergency Stop Monitor BH 9 - Data sheet Power Supply IR 9 - Data sheet Analogue Output Moule IL 7 - Data sheet Analogue Input Moule IL 8 - Data sheet Input- / Output Module IN 9 Approvals and Markings Application The PLC runs a user programm edited with the programming software PN. The programm can process local I/Os on the PLC as well as remote I/Os via the CANopen bus. Indicators green LED ON : yellow LED BUS : yellow LED RUN : green LED, : red LED O, O : on, when supply connected on, when bus is active on, when PLC in RUN state flashing, when failure on, when corresponding input is active (/C-, /C-) on, when corresponding output relay is active (/, /) All technical data in this list relate to the state at the moment of edition. We reserve the right for technical improvements and changes at any time. 9.. en /

Setting and Adjustment Digital inputs, Blind cover Connection auxiliary supply Watchdog contact for operation + C C Digital inputs, Connection auxiliary supply Watchdog contact for operation + C C LED "ON" LED "BUS" LED "RUN" LED ", " LED "/, /" E D S POWER BUS RUN IL k bit s ADR ADR RS transmission rate in Kb/s Programming interface RS device address ADR and ADR LED "ON" LED "BUS" LED "RUN" LED ", " LED "/, /" E D S POWER BUS RUN 87 IN kbit s ADR ADR RS lokaler Bus transmission rate in Kb/s Local bus Programming interface RS device address ADR and ADR CANopen interface CAN.H RAB Relays, CANopen interface CAN.H RAB CAN.L CAN_GND CAN.L CAN_GND M8876_a IL M799_a IN address: Relays, Blind cover To allow communication on the CANopen-Bus the device address has to be set with the rotational switches between... 99. Set-up Procedure:.) Connect device to CANopen-bus.) Terminate bus on both ends with bridge between and R ab.) Adjust transmission speed.) Set knot address.) Transmit program form PC to PLC IL with programming software and store it. Technical Data Auxiliary voltage Auxiliary voltage U H /: Voltage range: Nominal consumption: Input Inputs: Input voltage: Signalverzögerung: Output DC V.8.... U N. W digital inputs according to IEC/EN 6- galvanic separated by optocouplers DC V approx. ms Contacts: IL.: relay outputs monitoring contact - Thermal current I th : A Switching capacity to AC : A / AC V IEC/EN 6 97-- Switching capacity: at DC V: 8 W at AC V: 6 VA Short circuit strength max. fuse rating: AgL IEC/EN 6 97-- Mechanical life: > 6 switching cycles Technical Data Programming interface RS Wire: Null Modem wire link Transmission parameter: 7.6 KBaud, 8N The auxiliary voltage U H is not galvanically separated from the programming interface. CANopen interface Wire: Transmission speed: Attention: General Data screened twisted pair adjustable Kb/s, Kb/s, Kb/s, Mb/s, Both ends of the -wire bus have to be terminated with a bridge between CAN_H and R ab. The auxiliary voltage U H is not galvanically separated from the CANopen interface. Buffer for RAM and Realtime clock: years Cycle time: approx. ms + (. ms per translated Kb user program) Immunity against phase failure: ms Operating mode: Continuous operation Temperature range: -... + 6 C Clearance and creepage distances overvoltage category / pollution degree auxiliary voltage, CANopen interface to digital inputs:. kv / IEC 6 66- digital inputs to digital inputs:. kv / IEC 6 66- auxiliary voltage, CANopen interface to relay outputs: kv / IEC 6 66- relay outputs to relay outputs: kv / IEC 6 66-9.. en /

Technical Data EMC Electrostatic discharge: 8 kv (air) IEC/EN 6 -- HF-irradition: V/m IEC/EN 6 -- Fast transients: kv IEC/EN 6 -- Surge voltages between wires for power supply: kv IEC/EN 6 -- Interference suppression: Limit value class B EN Degree of protection Housing: IP IEC/EN 6 9 Terminals: IP IEC/EN 6 9 Housing: Thermoplastic with V-behaviour according to UL subject 9 Vibration resistance: amplitude. mm frequency... Hz, IEC/EN 6 68--6 Climate resistance: / 6 / IEC/EN 6 68- Terminal designation: EN Wire connection: Wire fixing: Standard Types IL. DC V Article number: relay outputs monitoring contact digital inputs DC V CANopen interface Auxiliary supply U H : DC V Width: mm IN. DC V Article number: 87 relay outputs monitoring contact digital inputs DC V CANopen interface Auxiliary supply U H : DC V Width:. mm x. mm solid or x. mm stranded wire with sleeve DIN 6 8-/-/-/- Flat terminals with self-lifting clamping piece IEC/EN 6 999- Mounting: DIN rail IEC/EN 6 7 Weight: g Dimensions Width x height x depth: IL : IN : x 9 x 8 mm. x 9 x 8 mm Accessories PN : Programming software Article number: 86 OA 9/8: Programming cable Article number: 9 IP.8: CANopen module with 8 binary inputs DC V Article number: 9 IP.8: CANopen module with 8 relay outputs Article number: 9 IN 9.: CANopen in- / output module with binary inputs DC V und relay outputs Article number: 99 IL 7.9/: Analogue output modul;... V; DC V Article number: 67 IL 7.9/: Analogue output modul;... V; DC V Article number: 67 IL 8.9/: CANopen module with analogue inputs... V Article number: 6 IL 8.9/: CANopen module with analogue inputs... ma Article number: 687 IL 8.9/: CANopen module with analogue inputs, PT Article number: 697 IR 9: Power supply for PLC and modules Article number: 6 IL : CANopen PLC Accessories Extension modules for extension bus of IN Module type Type Article no. Confuguration Input module IP. 8E DC V Output module IP.9 8 8A relays Input module IL. E DC V Output module IL.8 7 A relays 9.. en /

Application Example IL Application Example ventilation flap S C C minimaster IL. Adr. servodirive ventilation analogue output IL7 temperature analogue input IL8 S S6 C C I6 C6 input module IP.8 Adr. humidity analogue inout IL8 I7 C7 CANopen humidity sprinkler system forplant didital output IP L6 L7 6 6 7 7 output module IP.8 Adr. control digital input IP windows doors ** Both ends of the -wire bus have to be terminated with a bridge between and Rab. M78_d IL CANopen-SPS M96 CANopen-application for greenhouses: dependend on temperature- and humidity ventilation flap applications and sprinkler systems for plants in a greenhouse. 9.. en /

Application Example IN + - L7 S C C E C7 8 inputs IP. E7 7 8 outputs relays IP.9 7...V analogue inputs...v IP.9...V C E C7 8 inputs IP. E7 C minimaster IN. Adr. local extension bus (max. modules) C S S6 C I6 C6 I7 C7 input module IP.8 Adr. L6 6 6 output module IP.8 Adr. L7 7 7 ** Both ends of the -wire bus have to be terminated withabridge between and R ab. M887_a 9.. en /

E. DOLD & SÖHNE KG D-78 Furtwangen PO Box Telephone (+9) 77 / 6- Telefax (+9) 77 / 6-6 e-mail: dold-relays@dold.com internet: http://www.dold.com 6 9.. en /