Chapter. Hardware. In this Chapter...

Similar documents
Stride SE2 Series Unmanaged Industrial Ethernet Switches and Media Converters

Stride Industrial Ethernet Switches

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Chapter. Hardware. In This Chapter...

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

4-port 10/100TX + 1 or 2-port 100FX Industrial Switch. User Manual

Features and Benefits. Certifications

LNP-0602 series. 6-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 2*100Fx. User Manual

IEC-0101FT Industrial 10/100TX to 100M-FX Slim Type Converter User Manual

Device Server for the conversion of serial interfaces (RS-232/422/485) to IP.

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

IMC-21GA Quick Installation Guide

FL MC 2000E (SM40) LC

10/100TX to 100FX w/ 1 PoE Injector Industrial Media Converter User Manual

1 10/100TX FX w/ 1 PoE Injector Industrial Switch. User Manual

TN-5308 Quick Installation Guide

EDS-G205A-4PoE Quick Installation Guide

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Perle IDS-108F(XT) Unmanaged 10/100 Ethernet Switches. Installation Guide. P/N (Rev G)

EDS-G205-1GTXSFP/G308 Series

Features and Benefits. Certifications

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

PoE Powered Gigabit Ethernet Media Converters 1000BASE-T TO 1000BASE-SX/LX. KGC-352 Series. Installation Guide

User Manual Entry Line Industrial Fast Ethernet Switch 5x 10/100Base-TX

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

EDS-G205A-4PoE Hardware Installation Guide

FSM-510G Series Ethernet Management Switch Quick Start Guide

Industrial Gigabit Managed Ethernet Switch

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

KSD-800 Series. Installation Guide. Industrial 8-Port Fast Ethernet Switches with Fiber Connectivity DOC A -1-

ICPDAS FSM-510G Series Ethernet Management Switch Quick Start

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

Quick Start Guide. Physical Description. The Port Status LEDs

8~14-Port Managed Ethernet Switch

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

Quick Start Guide Elinx ESW200 Series. 5 and 8 port Unmanaged Ethernet Switch

Manual Documentation Number EIR418-2SFP-T 0912m

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

RuggedNet. RuggedNet GPoE+/Mi KEY FEATURES. Managed Industrial 10/100/1000 Power Source Equipment (PSE) PoE/PoE+ Ethernet Fiber Switch

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

Perle PoE/PoE+ 10/100/1000 Ethernet Media Converters

Quick Start Guide Elinx ESW100 Series. 5 and 8 port Unmanaged Ethernet Switch

LNX-0702G-SFP Series

Features and Benefits. Certifications

PHOENIX CONTACT - 10/2009

Moxa Industrial Media Converter

IMC-21A Quick Installation Guide

Chapter. Specifications. In this Chapter...

IPS-3110 Managed Industrial PoE Gigabit Ethernet Switch

Industrial 3-Port Fast Ethernet Media Converter Switches

Features and Benefits. Certifications

HARTING econ 3000 Introduction and features

EDR-G902/G903 Quick Installation Guide

EDS-G205-1GTXSFP Quick Installation Guide

Ethernet. RJ45 Copper Ports

KIEN2204S Industrial Ethernet Switch Hardware Installation Manual

ADAM-6541 Series. Ethernet to FiberOptic Converters. Features. Introduction. Specifications. Ordering Information

Perle Gigabit Media Converter Module. Installation Guide P/N

Features and Benefits. Certifications

MS400870M. User's Guide. Ver.: Port GBE SFP Switch 19 1U 24x10/100/1000T Combo 10/1000X SFP

Entry Line Industrial Gigabit Ethernet Bridging Converter, PoE+ optional 1x 10/100/1000Base-T, 1x 100/1000 SFP

6 10/100/1000TX + 2G Fiber Industrial Ethernet Switch User Manual

24-Port Gigabit Ethernet Switches

5 10/100TX w/ 4 PoE Injector Industrial Switch. User Manual

INDUSTRIAL GIGABIT SWITCHES

EDS-P206A-4PoE Series Hardware Installation Guide

MTL9200 Series Industrial ethernet switches and media converters

HARTING Ha-VIS mcon 3000 Next Generation Full managed Ethernet PROFINET Switch

5/8-Port Industrial Fast Ethernet Switch ISW-500/ISW-800. User's Manual

Perle PoE/PoE+ 10/100 Ethernet Media Converters

EDS-P206A-4PoE Series Quick Installation Guide

Lantech. IPGS-0005T /100/1000T PoE at T Industrial Unmanaged Switch. User Manual

Etherbus (EB Series) Hardware Guide USER MANUAL. Industrial Ethernet PoE Switch, Injectors, Splitter and More. Contents at a Glance:

Hardened Ethernet to VDSL2 Extender. User Guide. Revision History. Industrial Ethernet to VDSL2 Extender with Wide Operating Temp. Rev.1.

INJ-24A Series Quick Installation Guide

8-Port EN Certified Railway IP67 WATERPROOF MANAGED Gigabit PoE SWITCH. EMG8508 Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

IMC-21 Quick Installation Guide

HES-3109 SERIES 9 PORTS 10/100/1000BASE-T MANAGEMENT ETHERNET SWITCH

MF BASE-T to 1000BASE-X INDUSTRIAL MEDIA CONVERTER WITH SFP SUPPORT INSTALLATION GUIDE

LNX-1002C-SFP Series

LevelOne. User Manual GSW-1656/GSW /24-Port Gigabit Switch w/ 4-Port SFP. Version

Chapter. Getting Started. In this Chapter...

D-Link Switch User Manual. Table of Contents

EDS-210A Series Hardware Installation Guide

PoE Powered 10/100BASE-TX to 100BASE-FX Media Converters. KC-351 Series. Installation Guide

EDS-210A Quick Installation Guide

Industrial Switches Industrial Switches

MOXA EtherDevice Switch

Moxa ToughNet Switch

Overview. Features CHAPTER

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

MF727xS INDUSTRIAL 10/100BASE-TX TO 100BASE-FX MEDIA CONVERTER. Installation Guide

Industrial 6-port unmanaged Gigabit PoE Ethernet switch with 4x10/100/1000Base-T(X) P.S.E. and

EDS-G308 Series Quick Installation Guide

IES User Manual. 8 FE + 1 MM SC Unmanaged Switch -40 to 75, DIN-rail. v

ROCKETLINX ES7110 ES7110/ES7110-VB

Transcription:

Hardware hapter In this hapter... Introduction... - onventions Used... - General Information... - Product Overview Stride SE Unmanaged Models... - Product Overview Stride SE PoE Unmanaged Models... - Product Overview Stride SE Managed Models... - Switch ccessories... - SFP Fiber Transceivers... - Mounting rackets... - IP Switch (Unmanaged IN rail mounted switches)... -0 Reset (Managed Switches)... - LE Indicators... - Installation, IN Rail Mounting... - Installation, Optional Panel Mounting... - Installation, IP Switches Panel Mounting... - imensional rawings... - Power Wiring... - ommunication Ports Wiring... - Technical Specifications... - Unmanaged Models... - Unmanaged PoE Models... - Unmanaged IP Rated Models... - Managed Models... -

hapter : Hardware 0 Introduction The Purpose of this User s Manual Thank you for purchasing our Stride SE series Industrial Ethernet Switches. This manual describes utomationirect.com s Stride industrial Ethernet switches, their specifications, included components, and provides you with important information for installation, connectivity and setup. The manual shows you how to install, wire and use the products. Technical Support We strive to make our manuals the best in the industry. We rely on your feedback to let us know if we are reaching our goal. If you cannot find the solution to your particular application, or, if for any reason you need technical assistance, please call us at: 0 00 Our technical support group will work with you to answer your questions. They are available Monday through Friday from :00 a.m. to :00 p.m. Eastern Time. We also encourage you to visit our web site where you can find technical and non-technical information about our products and our company. http://www.automationdirect.com If you have a comment, question or suggestion about any of our products, services, or manuals, please let us know. onventions Used When you see the notepad icon in the left-hand margin, the paragraph to its immediate right will be a special note. The word NOTE: in boldface will mark the beginning of the text. When you see the exclamation mark icon in the left-hand margin, the paragraph to its immediate right will be a warning or a caution. This information could prevent injury, loss of property, or even death (in extreme cases). The words WRNING or UTION: in boldface will mark the beginning of the text. - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware General Information Overview This user s manual will help you install and maintain the Stride industrial Ethernet switches. Installation of these devices is very easy and they will begin to operate as soon as they are powered up. Operation Unlike an Ethernet hub that broadcasts all messages out all ports, these industrial Ethernet switches will intelligently route Ethernet messages only out the appropriate port. The major benefits of this are increased bandwidth and speed, reduction or elimination of message collisions, and deterministic performance when tied with real-time systems. These industrial Ethernet switches can support 0aseT (0 Mbps) or 00aseT (00 Mbps) or 000aseT (Gigabit Ethernet) on their RJ ports. Each of these ports will independently auto-sense the speed and duplex, mdi/mdix-crossover and polarity allowing you to use patch or crossover cables. Some models include fiber optic ports, or slots that accept SFP fiber optic transceivers. 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 Installation and Hazardous rea Warnings WRNING: These products should not be used to replace proper safety interlocking. No software-based device (or any other solid-state device) should ever be designed to be responsible for the maintenance of consequential equipment or personnel safety. In particular, utomationirect.com disclaims any responsibility for damages, either direct or consequential, that result from the use of this equipment in any application. ll power, input and output (I/O) wiring must be in accordance with lass I, ivision wiring methods and in accordance with the authority having jurisdiction. WRNING (EXPLOSION HZR) WRNING (EXPLOSION HZR) WRNING (EXPLOSION HZR) WRNING (EXPLOSION HZR) SUSTITUTION OF OMPONENTS MY IMPIR SUITILITY FOR LSS, IVISION (ZONE ). WHEN IN HZROUS LOTIONS, ISONNET POWER EFORE REPLING OR WIRING UNITS. O NOT ISONNET EQUIPMENT UNLESS POWER HS EEN SWITHE OFF OR THE RE IS KNOWN TO E NONHZROUS. IN HZROUS OR POTENTILLY HZROUS LOTIONS, O NOT SEPRTE NY PRT OF THE UNIT WHEN ENERGIZE. USE THE UNIT FOR INTERNL ONNETIONS ONLY. F Statement This equipment has been tested and found to comply with the limits for a lass digital device, pursuant to part of the F Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. NOTE: Modifications to this equipment will void the user s authority to operate the equipment. - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Product Overview Stride SE Unmanaged Models Number of Ports Part Number M 0/00 0/00 RJ RJ GbE Fiber SE-MU--T S SE-MU-T-T ST SE-SWU SE-SWU-T Stride SE Unmanaged Models Input power (max.). W SE-SWUG-T. W SE-SWU--T S SE-SWU-T-T ST SE-SWU SE-SWU-T SE-SWU--T S SE-SWU-T-T ST SE-SWUG-T SE-SW0UG-P-T GbE SFP* SE-SWU-T SE-SWU-G-T SE-SWU-N-T SE-SWU-N-T. W. W 0W W. W Operating Temp -0 to + (-0 to + F) -0 to +0 (+ to +0 F) -0 to + (-0 to + F) -0 to +0 (+ to +0 F) -0 to + (-0 to + F) -0 to + (-0 to + F) NOTE: Optional SFP modules sold separately. Use only Gigabit speed SFPs with SE-SW0UG-P-T. gency pprovals UL/cUL 00- and 00--0, lass, iv., Groups,,,, (UL file #E000) E E, UL00-, UL00--0 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 Product Overview Stride SE PoE Unmanaged Models Part Number RJ 0/00 Stride SE Unmanaged PoE Models Number of Ports RJ RJ GbE 0/00 PoE RJ GbE PoE SE-SWPU-T SE-SWPUG-T Operating Temp -0 to + (-0 to + F) gency pprovals UL/cUL 00- and 00--0 lass, iv., Groups,,,, (UL file #E000) E - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Product Overview Stride SE Managed Models Stride SE Series Managed Models Part Number Ethernet Ports Fiber Ports Input Power (max) Operating Temp SE-SWM. W SE-SWM-P SE-SWM- SE-SWM-T GbE SFP* S ST SE-SWM SE-SWMG-P, GbE combo * Optional SFP modules sold separately. GbE SFP combo*. W. W W -0 to + (-0 to + F) gency pprovals UL/cUL 0, lass, iv., Groups,,,, (UL file #E000), E 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 Switch ccessories SFP Fiber Transceivers Stride SFP (small form-factor pluggable) transceivers, also called mini-gi, are compact, hot-swappable transceivers with L fiber connectors. Models SE-SWM-P, SESWMG-P, and SE-SW0UG-P-T have ports that accept these optional transceivers to add fiber connectivity at Fast Ethernet or Gigabit Ethernet speed. NOTE: SE-SW0UG-P-T will only accept Gigbit speed SFPs. SFP Fiber Transceivers Part Number Mode ata Rate Light Source Max Trans. istance SFP-K-FMF Multi-mode km Fast Ethernet (M) 0 nm, FP SFP-0K-FSF Single-mode 0 km SFP-00-GMF 0 nm, VSEL 0m Multi-mode SFP-K-GMF km Gigabit (. G) 0 nm, FP SFP-0K-GSF 0 km Single-mode SFP-0K-GSF 0 nm, F 0 km - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Mounting rackets SE-PM and SE-PM panel mounting brackets allow IN rail mount models of Stride SE series Ethernet switches to be mounted to a panel or an appropriate flat surface. SE-PM is compatible with SE-SWUx, SE-SWU-x, and SE-Mx SE-PM is compatible with SE-SWPx, SE-SWUG-T, SE-SW0UG-P-T, SE-SWU-T, SE-SWU-G-T and all SE managed switches. See the Installation, Optional Panel Mounting section later in this chapter for specific instructions. 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 IP Switch (Unmanaged IN rail mounted switches) IP switch I enables the broadcast storm protection feature on the unmanaged IN rail mounted switches. broadcast storm is usually caused by a loop in the network and results in network traffic interruption. The broadcast storm protection feature is especially useful in a more complex network of many unmanaged switches, particularly when cables are disconnected and reconnected frequently. IP switch II provides different functions based on the model. IP switch II - GbE switches - ON enables Jumbo frame support IP switch II is not used on other switches. IP switches -0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Reset (Managed Switches) The switch can be reset (power cycle) by pressing the RESET button on the face of the switch for - seconds. The switch will be RESET to FTORY EFULT by pressing the RESET button on the face of the switch for seconds. The switch may also be reset or restored to factory defaults via the switch management interface. Reset 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 LE Indicators LEs on IN rail Mounted Models ctivity/link and Speed LEs PoE LE Power LEs Power LEs ctivity/link and Speed LEs T/LNK LE Speed LE 0/00 Models Speed LE 0/00/000 Models On linking Off On Off On Off On RUN * linking (Hz) Off On larm * Off On PWR LE Off On PWR LE Off On RING * linking Off On PoE** Off * Managed switches only ** PoE switches only ommunication LEs Indicates that there is a proper Ethernet connection (Link) between the port and another Ethernet device, but no communications activity is detected. Indicates that there is a proper Ethernet connection (Link) between the port and another Ethernet device, and that there is communications activity. Indicates that there is not a proper Ethernet connection (Link) between the port and another Ethernet device. Make sure the cable has been plugged securely into the ports at both ends. 00 Mbps (00aseT) connection is detected. 0 Mbps (0aseT) connection is detected. 000 Mbps (000aseT) connection is detected 00 or 0 Mbps (00aseT or 0aseT) connection is detected Front Panel LEs PU is running abnormally or the switch is starting PU is running normally PU is not running System alarm No system alarm Power connected and operational Power no voltage Power connected and operational Power no voltage Master (-Ring mode) / Root (P mode) Slave (-Ring mode) / -Root (P mode) No ring mode Port is providing power Port is not providing power - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware LEs on IP Models Power LEs Power LE Power LE Ethernet port connection status LE On Off On Off On linking Off IP Models Front Panel LEs Power connected and operational Power no voltage Power connected and operational Power no voltage Ethernet port connected Ethernet port active Ethernet port no connection Ethernet LEs (one per M connection) 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 Installation, IN Rail Mounting Stride SE series switches can be snapped onto a standard mm x. mm height IN rail (Standard: ENELE EN00) and can be mounted either vertically or horizontally. See Installation, IP Switches Panel Mounting later in this chapter for mounting IP rated switches. llow cm (0. in) of clearance between the SE switch and other equipment on the IN rail, side to side and top to bottom. NOTE: Make sure to allow enough room to route your Ethernet copper or fiber optic cables. IN rail installation steps (ll Models): Push bottom back onto the IN rail until it snaps into place. Hook top back of unit over the IN rail. LIK IN rail removal steps (Unmanaged Models): Push the unit down to free the bottom of the IN rail. Rotate the bottom of the unit away from the IN rail. Unhook top of unit and lift switch up to remove from IN rail. - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware IN rail removal steps (Unmanaged Models): Insert screwdriver into spring locking plate and rotate upward to release IN rail clamp. Rotate body of unit. Lift unit up to remove from IN rail. 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 Installation, Optional Panel Mounting Stride SE in rail series switches can be panel mounted with the addition of the optional panel mounting brackets SE-PM or SE-PM. SE-PM is compatible with SSE-SWUx, SE-SWU-x, and SE-Mx SE-PM is compatible with SE-SWPx, SE-SWUG-T, SE-SW0UG-P-T, SE-SWU-T, SE-SWU-G-T and all SE managed switches. Mounting Instructions Remove IN Rail racket Install SE-PM() racket with supplied flathead screws Secure SE-PM() racket with surface appropriate hardware. (Surface mounting hardware is not included). - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Installation, IP Switches Panel Mounting IP rated switches are designed to be panel mounted vertically or horizontally using the steps below. Panel mounting steps: Use the dimensional drawing to locate () mounting screws on the panel. Recommended screws are #-0 pan head. Install the screws in the panel leaving a gap of mm between the head of the screw and the panel. lign the () mounting holes with the screw heads and move the switch on to the () mounting screws. llow the switch to slide into position. Tighten the four mounting screws. 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 imensional rawings NOTE: llow 0mm (0. in) clearance around each switch for proper cooling. imensions mm / [inches] SE-MU--T, SE-MU-T-T, SE-SWU, SE-SWU-T, SE-SWUG-T, SE-SWU--T, SE-SWU-T-T SE-SWU--T SE-SWU SE-SWU-T SE-SWU-T-T - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware imensional rawings (cont d) NOTE: llow 0mm (0. ) clearance around each switch for proper cooling. imensions mm / [inches] SE-SWUG-T SE-SWU-T SE-SW0UG-P-T 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 imensional rawings (cont d) NOTE: llow 0mm (0. ) clearance around each switch for proper cooling. imensions mm / [inches] SE-SWU-G-T SE-SWPU-T SE-SWPUG-T -0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware imensional rawings (cont d) imensions mm / [inches] SE-SWU-N-T SE-SWU-N-T 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 imensional rawings (cont d) imensions mm / [inches] SE-SWM SE-SWM-P - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware imensional rawings (cont d) imensions mm / [inches] SE-SWM- SE-SWM-T 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 imensional rawings (cont d) imensions mm / [inches] SE-SWM SE-SWMG-P - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware imensional rawings (cont d) imensions for SFP Transceiver Modules imensions mm / [inches] SFP-K-FMF, SFP-0K-FSF, SFP-00-GMF, SFP-K-GMF, SFP-0K-GSF and SFP-0K-GSF 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 Power Wiring WRNING: efore performing any wiring to these switches make sure... The area is currently nonhazardous (especially when working in lass, iv or Zone hazardous locations). Power is off to the switch The screw terminal block is unplugged. This is especially important on the aluminum housed units. onnecting or disconnecting wires to the screw block when it s in place and power is turned on can allow the screwdriver to short the power to the case. Unmanaged non-poe Models (IN rail mount) The switch can be powered from the same source that is used to power your other devices. To maintain the UL listing, this must be a lass power supply., or V or V needs to be applied between the P+ terminal and the P- terminal as shown below. The chassis screw terminal should be tied to panel or chassis ground. To reduce down time resulting from power loss, the switch can be powered redundantly with a second power supply as shown below. The switch is equipped with reverse power protection, but care should be taken to connect the positive and negative terminals correctly. recommended power supply is utomationirect.com part number PSL--00. Power Input Input Voltage Reverse Power Protection Wire Size and Torque Power onsumption Power etails Redundant Input Terminals lass Power Supply: - V, -0 V Yes - WG, max wire length m (. ft); Wire strip length mm; Torque:.-.0 lb in (0.-0. N m) Refer to Models tables on previous pages in this chapter. Redundant Power P- P+ P- P+ + + Optional ual Supplies hassis GN (panel) - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Unmanaged PoE Switches Power Input NOTE: In order to source power (PSE), a PoE switch must be supplied with - V. When supplied with - V, the switch will communicate properly via Ethernet but will not source power by PoE to a connected device (P). The switch can be powered from the same source that is used to power your other devices. To maintain the UL listing, this must be a lass power supply. V must be applied between the P+ terminal and the P- terminal as shown. The chassis screw terminal should be tied to panel or chassis ground. To reduce down time resulting from power loss, the switch can be powered redundantly with a second power supply as shown below. The switch is equipped with reverse power protection, but care should be taken to connect the positive and negative terminals correctly. recommended power supply is utomationirect.com part number PS-0S. Power etails Redundant Power Input Voltage Reverse Power Protection Wire Size and Torque Power onsumption Power udget Ground onnection Redundant Input Terminals lass Power Supply: or V for Ethernet communications only, - V for PoE (. W per port) - V for PoE+ (0W per port) Yes - WG, max wire length m (. ft); Wire strip length mm; Torque:. lb in (0.0 N m) switch only = W Ensure power supply to the switch is sized adequately to account for powered devices (P). switch plus Ps = W max < Ω - WG hassis GN (panel) P+ P- P+ P- Optional ual Supplies NOTE: lthough the IEEE 0.af/at standards require the P to be insensitive to the polarity of the power supply, care should be taken to confirm that the connected P is fully compliant to the standard. If the connected P is sensitive to the power polarity, select an appropriate Ethernet cable, straight through or crossover, to meet the requirements of the connected P. + + 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 M onnector Equipped Models The switch can be powered from the same source that is used to power your other devices. To maintain the UL listing, this must be a lass power supply., or V or V needs to be applied through an M ( coded, female, -pin) connector as shown in the chart below. The chassis ground screw located on the front of the switch housing should be tied to panel or chassis ground. To reduce down time resulting from power loss, the switch can be powered redundantly with a second power supply as shown in the chart below. The switch is equipped with reverse power protection, but care should be taken to connect the positive and negative terminals correctly. Power Port Pin efinitions Pin Wiring Wiring P - PWR: - PWR P + PWR: + PWR P - PWR: - PWR P + PWR: + PWR - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Managed Switches The switch can be powered from the same source that is used to power your other devices. To maintain the UL listing, this must be a lass power supply. voltage in the range of to V needs to be applied between the P+ terminal and the P- terminal as shown below. The chassis screw terminal should be tied to panel or chassis ground. To reduce down time resulting from power loss, the switch can be powered redundantly with a second power supply as shown below. recommended power supply is utomationirect.com part number PSL--00. Redundant Power PWR PWR P+ P- P- P+ + + hassis GN Power Input Input Voltage Reverse Power Protection Wire Size and Torque Power onsumption ommunication Ports Wiring Power etails Redundant Input Terminals lass Power Supply: - V Yes - WG, max wire length m (. ft); Wire strip length mm; Torque:. lb in (0. N m) Refer to Models tables on previous pages in this chapter Overview The industrial Ethernet switches provide connections to standard Ethernet devices such as PLs, Ethernet I/O, industrial computers and much more. RJ or M (for IP locations) Ethernet ports or fiber/sfp option ports are available depending on model. Ethernet Wiring Use data-quality (not voice-quality) twisted pair cable rated category e (or better) with standard RJ or M ( coded, male, -pin) connectors. Straight-through or crossover Ethernet cable can be used for all devices the switch is connected to because all the ports are capable of auto-mdi/mdix-crossover detection. The RJ Ethernet port connector bodies on these products are metallic and connected to the hassis GN terminal. Therefore, shielded cables may be used to provide further protection. To prevent ground loops, the cable shield should be tied to the metal connector body at one end of the cable only. Electrical isolation is also provided on the Ethernet ports for increased reliability. uplex Operation The RJ and M ports will auto-sense for Full or Half duplex operation. NOTE: M caps (part number: ZP-JH-P) must be used on open (disconnected) ports. 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 Ethernet able Wiring Straight-thru able Wiring Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin NOTE: For reference only. Either cable wiring will work. ross-over able Wiring Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Pin Ethernet Plug & onnector Pin Positions PoE Switch Ethernet Port Pin efinitions Pin Pin V - TR - V + V - V - TR + TR + (transmit / receive data) TR - able istance The maximum cable length for 0/00/000aseT is 00 meters ( ft.). M ommunication Wiring ommunication Port Pin efinitions Pin MI Signal Transmit ata + (T+) Receive ata + (R+) Transmit ata - (T-) Receive ata - (R-) -0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Ethernet Fiber Wiring Guidelines Some switches include fiber ports, either S or ST connector, or an SFP option. Refer to the switch specifications for details on the available connection types. For each fiber port there is a transmit (TX) and receive (RX) signal. When making your fiber optic connections, make sure that the transmit (TX) port of the switch connects to the receive (RX) port of the other device, and the receive (RX) port of the switch connects to the transmit (TX) port of the other device. Use standard fiber optic wiring techniques (not covered by this manual) to make your connections. It is important to consider the output power and the receiver sensitivity for each end of each fiber connection, especially when the distances that each fiber transceiver in each switch are specified to support differ or when the transceivers (switches) are separated at a distance different than that which the transceivers are specified to support. It is important to include in your network design an evaluation of the output power and receiver sensitivity based on: Switch Tx Rx Switch The fiber cable loss (LF) plus attenuator loss (LR) should be greater than the transmit power (TX) minus the receive power (RX). So, Rx Tx LR = TX RX LF, for the attenuator (LR) placed at RX and LR = TX RX LF, for the attenuator (LR) placed at RX. Verifying onnectivity fter all Ethernet and/or fiber connections are made, check the LEs corresponding to the ports that each of the devices are connected to. Ensure that for each port that is in use, the LE is on or blinking. If a port LE is off, go back and check for connectivity problems between that port and the network device connected to that port (see prior section on LEs). larm Wiring larm conditions may be configured in the switch, see hapter for details. When an alarm condition is true, the normally open contact closes and the normally closed contact opens up. 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 Technical Specifications Unmanaged Models The following specifications refer to these models. SE-MU--T SE-SWU SE-SWU SE-SW0UG-P-T SE-MU-T-T SE-SWU-T SE-SWU-T SE-SWU-T SE-SWUG-T SE-SWU--T SE-SWU-G-T SE-SWU--T SE-SWU-T-T SE-SWU-T-T SE-SWUG-T General Specifications Operating Mode Store and forward wire speed switching, non-blocking evices Supported ll IEEE 0. compliant devices are supported M ddresses K for SE-SWxG-T, SE-SWU-T, SE-SWU-G-T K Packet uffer Mbit 0. Mpps - SE-MU-x, SE-SWU & SE-SWU-x. Mpps - SE-SWU-x Packet Forwarding Rate. Mpps - SE-SWUG-T. Mpps - SE-SWUG-T & SE-SW0UG-P-T. Mpps - SE-SWU-T & SE-SWU-G-T roadcast Storm Protection* IP switch enabled (IP switch I) Latency < 0 µs Jumbo Frame Support IP switch enabled for SE-SWUG-T, SE-SWUG-T, SE-SW0UG-P-T and SE-SWU-G-T only (IP switch II ON)** Storage Temperature Range -0 to + (-0 to + F) Humidity (non-condensing) to % RH Environmental ir No corrosive gases permitted Vibration, Shock & Freefall IE00--, -, - EMI Emissions F FR Part, EN0/ISPR, lass IE000-- (ES): +/- kv (contact), +/- kv (air) IE000-- (RS): 0V/m (0MHz ~ GHz) EMS IE000-- (EFT): Power Port +/- kv; ata Port: +/- kv IE000-- (Surge): Power Port: +/- kv/m, +/- kv/m; ata Port +/- kv IE000-- (S): 0V (0kHz ~ 0MHz) RoHS and WEEE RoHS (Pb free) and WEEE compliant Packaging and Protection Metal case, IP0 Hazardous Locations NSI/IS..0-0 & S. No. - (lass I, iv.) (file #E000); UL/cUL 00- and 00--0, gency pprovals lass, iv., Groups,,,, (UL file #E000) E * roadcast storm threshold value is packets/00ms for 0 Mbps port or packets/0ms for 00 Mbps and 000 Mbps ports. ** IP switch II is unused on the 0/00 models. - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Unmanaged Models Technical Specifications (cont d) Power Input Input Voltage Reverse Power Protection Power onsumption Port Type Ethernet ompliance uto-rossover uto-sensing Operation uto-negotiating Speed Flow ontrol able Requirements Max. able istance Power etails Redundant Input Terminals lass Power Supply: - V, -0V 0/0 Hz Yes Refer to Models tables on previous pages in this chapter RJ Ports Shielded RJ IEEE 0.i, 0.u, 0.x for 0/00 Ethernet IEEE 0.ab, 0.z for Gigabit Ethernet Yes, allows you to use straight-through or crossover wired cables Yes, full and half duplex Yes utomatic Twisted pair (ate or better) (shielded recommended) 00 meters S/ST Fiber Port: (00aseFX Multimode) 00aseFX Ports Fiber Port onnector ST or S, by model Optimal Fiber able 0/ or./ µm enter Wavelength 00 nm Multimode Links up to km typ. > Transmitter power (dm): - min, - typ, - max > Receiver sensitivity (dm): - typ, - max Nominal Max. istance (full duplex) km Eye Safety (laser) IE 0-, lass ; F FR 00.0 and 00. SFP (Small Form Factor Pluggable) Ports Optional SFP modules sold separately. Use only Gigabit speed SFPs with SE-SW0UG-P-T. Eye Safety IE 0-, lass ; F FR 00.0 and 00. NOTE: Refer to SFP module specifications for details specific to the SFP installed. 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 Unmanaged PoE Models The following specifications refer to these models. SE-SWPU-T SE-SWPUG-T General Specifications Operating Mode Store and forward wire speed switching, non-blocking evices Supported ll IEEE 0. compliant devices are supported M ddresses K Packet uffer Mbit Packet Forwarding Rate. Mpps roadcast Storm Protection* IP switch enabled (IP switch I) Latency < µs Jumbo Frame K Storage Temperature Range -0 to + (-0 to + F) Humidity (non-condensing) to % RH Environmental ir No corrosive gases permitted Vibration, Shock & Freefall IE00--, -, - EMI Emissions F FR Part, EN0/ISPR, lass IE000-- (ES): +/- kv (contact), +/- kv (air) IE000-- (RS): 0V/m (0MHz ~ GHz) EMS IE000-- (EFT): Power Port +/- kv; ata Port: +/- kv IE000-- (Surge): Power Port: +/- kv/m, +/- kv/m; ata Port +/- kv IE000-- (S): 0V (0kHz ~ 0MHz) RoHS and WEEE RoHS (Pb free) and WEEE compliant Packaging and Protection Metal case, IP0 Hazardous Locations NSI/IS..0-0 & S. No. - (lass I, iv.) (file #E000); UL/cUL 00- and 00--0 gency pprovals lass, iv., Groups,,,, (UL file #E000) E * roadcast storm threshold value is packets/00ms for 0 Mbps port or packets/0ms for 00 Mbps and 000 Mbps ports. IP switch II is unused. - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Unmanaged PoE Models Technical Specifications (cont d) Power Input Input Voltage Reverse Power Protection Wire Size and Torque Wire Temperature Power onsumption Power udget Ground onnection Port Type Ethernet ompliance uto-rossover uto-sensing Operation uto-negotiating Speed Flow ontrol able Requirements Max. able istance Max Power per Port Power etails Redundant Input Terminals lass Power Supply or V for Ethernet communications only, - V for PoE (. W per port) - V for PoE+ (0W per port) Yes - WG, max wire length m (. ft); Wire strip length mm; Torque:. lb in (0. N m) ( F) Max. switch only = W Ensure power supply to the switch is sized adequately to account for powered devices (P). switch plus Ps = W max < Ω - WG RJ Ports Shielded RJ IEEE 0.i, 0.u, 0.x for 0/00 Ethernet IEEE 0.ab, 0.z for Gigabit Ethernet IEEE 0.af or 0.at for PoE Yes, allows you to use straight-through or crossover wired cables Yes, full and half duplex Yes utomatic Twisted pair (ate or better) (shielded recommended) 00 meters PoE etails 0W at - V 0m V+ pins, V- pins, Power Input - V for PoE+ - V for PoE Yes - the switch port will detect the presence of a PoE enabled device before P (Powered evice) etection sending power. If a non-poe device is detected, power will not be sourced on that port but Ethernet connections will be permitted. PoE Overload Protection Yes Reverse Protection Yes Redundancy Protection Yes 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 Unmanaged IP Rated Models The following specifications refer to these models. SE-SWU-N-T SE-SWU-N-T General Specifications Operating Mode Store and forward wire speed switching, non-blocking evices Supported ll IEEE 0. compliant devices are supported M ddresses K Packet uffer Mbit Packet Forwarding Rate. Mpps Latency < 0 µs Operating Temperature Range -0 to + (-0 to + F) Storage Temperature Range -0 to + (-0 to + F) Humidity (non-condensing) to % RH Pollution egree Vibration and Shock IE00--, -, - Freefall IE00-- Safety EN00- EMI Emissions F FR Part, EN0/ISPR, lass IE000-- (ES): ± kv (contact), ± kv (air) IE000-- (RS): 0V/m (0MHz ~ GHz) IE000-- (EFT): Power Port ± kv; ata Port: ± kv IE000-- (Surge): Power Port: ± kv/m, ± kv/m EMS IE000-- (S): 0V (0 khz ~ 0 MHz) IE000-- (Power frequency magnetic field) :0 Hz 00/m IE000-- (Pulsed magnetic field) :00/m IE000-- (Voltage short interruptions) :0ms 00% RoHS and WEEE RoHS (Pb free) and WEEE compliant Packaging and Protection Metal ase, IP gency pprovals UL/cUL 00- and UL/cUL 00--0 (UL file #E), E, EN0, EN0 Power Input Input Voltage Power Input Ports Reverse Power Protection Power etails Redundant Input M connector lass Power Supply: - V, -0V 0/0 Hz M, male, -coding, -pin Yes - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Unmanaged IP Rated Models (cont d) M Ethernet Ports 0/00aseT ports M, female, -coding, -pin Ethernet ompliance IEEE 0.i, 0.u, 0.x uto-rossover Yes, allows you to use straight-through or crossover wired cables uto-sensing Operation Yes, full and half duplex uto-negotiating Speed Yes Flow ontrol utomatic able Requirements Twisted pair (at or better) (shielded recommended) Max. able istance 00 meters M caps (ZP-JH-P) need to be used on open (disconnect) ports. 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -

hapter : Hardware 0 Managed Models The following specifications refer to these models. Operating Mode evices Supported M ddresses Ethernet Protocols Supported Industrial Protocols Supported Packet Forwarding Rate SE-SWM SE-SWM- SE-SWM-T SE-SWM-P General Specifications SE-SWM SE-SWMG-P Store and forward wire speed switching, non-blocking ll IEEE 0. compliant devices are supported K K for SE-SWM-P SNMP v / v / v, RMON, HP, SNTP, TFTP, STP, RSTP, QoS / S, IGMPv / v, VLN (tag and port based), HTTP, HTTPS (SSL and TSL), Telnet, SSH and more Modbus TP, EtherNet/IP, PROFInet, Foundation Fieldbus HSE and others. Mpps SE-SWM. Mpps SE-SWM-. Mpps SE-SWM-T. Mpps SE-SWM-P. Mpps SE-SWM. Mpps SE-SWMG-P Latency < 0 µs Operating Temperature Range Storage Temperature Range Humidity (non-condensing) Environmental ir -0 to + (-0 to + F) -0 to + (-0 to + F) to % RH No corrosive gases permitted Vibration, Shock & Freefall IE00--, -, - EMI Emissions EMS Hazardous Locations RoHS and WEEE Packaging and Protection gency pprovals F FR Part, EN0/ISPR, lass IE000-- (ES): ± kv (contact), ± kv (air) IE000-- (RS): 0V/m (0MHz ~ GHz) IE000-- (EFT): Power Port ± kv; ata Port: ± kv IE000-- (Surge): Power Port: ± kv/m, ± kv/m; ata Port ± kv IE000-- (S): 0V (0kHz ~ 0MHz) NSI/IS..0-0 & S. No. - (lass I, iv.) (file #E000); RoHS (Pb free) and WEEE compliant Metal case, IP0 UL/cUL 0, E - Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev.

hapter : Hardware Managed Models (cont d) Power Input Input Voltage Reverse Power Protection Wire Size and Torque Power onsumption Port Type Ethernet ompliance uto-rossover uto-sensing Operation uto-negotiating Speed Flow ontrol able Requirements Max. able istance Power etails Redundant Input Terminals lass Power Supply: - V Yes - WG, max wire length m (. ft); Wire strip length mm; Torque:. lb in (0. N m) Refer to Models table on previous pages in this chapter RJ Ports Shielded RJ IEEE 0.i, 0.u, 0.x for 0/00 Ethernet IEEE 0.ab, 0.z for Gigabit Ethernet Yes, allows you to use straight-through or crossover wired cables Yes, full and half duplex Yes utomatic Twisted pair (ate or better) (shielded recommended) SFP Ports 00 meters SFP (pluggable) ports accept Mini-GI (SFP) transceivers with a speed of 000Mbps or 00Mbps See SFP datasheet for optional fiber transceiver specification S or ST Fiber Port: (00aseFX multimode) 00aseFX Ports Fiber Port onnector ST or S, by model Optimal Fiber able 0/ or./ µm enter Wavelength 00 nm Links up to km typ. Multimode > Transmitter power (dm): - min, - typ, - max > Receiver sensitivity (dm): - typ, - max Nominal Max.istance km (full duplex) Eye Safety (laser) IE 0-, lass ; F FR 00.0 and 00. 0 Stride SE Series Industrial Ethernet Switches User Manual nd Ed. Rev. -