Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Similar documents
UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

SSW06. Soft Starters.

GRASSO SYSTEM CONTROL

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

Product data sheet accessories control and regulation Accessories AIRWIN

PTC/PT100 board 2.0 Option

1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...

PTC/PT100 board 2.0 Option

PTC/PT100 board 2.0 Option

PowerView Model PV350 and PV380. Installation Manual Section 78

MCX08M2 Programmable controller

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Digital Indicator Solutions

Andover ContinuumTM Infinet II

Monitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064

SIMOCODE 3UF Motor Management and Control Devices

Comprehensive Modular Genset Controller

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Intelligent Controller. Sigma Control 2

6ES7212-1BD30-0XB0. permissible range, lower limit (DC) permissible range, upper limit (DC)

B-CONTROL MICRO BKM / Jens Brenneis

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Power Panel Integrated control, operation and visualization

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Andover Continuum Infinet II i2865/866 VAV Controllers with Built-in Actuator

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

Power Panel. Terminal block, 12 pin, 20 pcs., cage clamps. Table 5: Order data for PP41

General information. Display. Supply voltage

Gas Controller System DGC-06

General information. Display. Supply voltage. Input current. Encoder supply. Power losses

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

General information. Display. Supply voltage. Input current

Operating instructions. Switching amplifier DN0210 DN / / 2015

Andover ContinuumTM Infinet II

Supplementary operating instructions for your air curtain system Controller TMC 500

Built-in features Built-in simplicity Built for fans & pumps

Faults on the system Proximity switch connection technology:

Voltage Current Front-mounting bracket

PowerView TM Model PV350 and PV380. Operations Manual Section 78

Features and Benefits of XeteX Controls. Other Unit Control Functions. Energy Recovery Functions

MiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...

Electronic SD1, AS 8, ASR 14, ASR 20

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

Technical Manual Nova: Cabinet Security Management System (CSMS)

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

Data logger systems from ROTRONIC

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

Valve and Case Expansion Monitor Specifications

Andover ContinuumTM b3865/866 VAV Controllers with Built-in Actuator

NEUROLOGIC RESEARCH CORPORATION MODEL 2500

MID approval no. DE-08-MI004-PTB004 Date of release

Ordering Key. Type Rated Operational Rated operational Control Voltage Uc Options

Q9 ASD LOW VOLTAGE DRIVE

BACnet. b3810 Series Local Controllers

MMT330 Series Moisture and Temperature Transmitters for Oil

lnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD

IQ21x Series Controllers

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

Supply voltage. Input current. Encoder supply. Memory SIMATIC S7-200, CPU 221 COMPACT UNIT, DC POWER SUPPLY 6 DI DC/4 DO DC, 4 KB CODE/2 KB DATA,

InteliLite MRS17 Click Here to Learn More

General information. Display. Supply voltage. Input current

DM650TM SENSOR / WALL MOUNTED TEMPERATURE DISPLAY

General information. Display. Supply voltage. Input current. Encoder supply. Output current

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

MBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit

Display. Supply voltage. Input current. Encoder supply. Output current. Power losses. Memory

- NLS NAVIGATION LIGHT CONTROL

General information Engineering with Programming package. Display with display. Supply voltage 24 V DC Yes

LC-1 Level Controller & Flow Monitor

Monitoring Technique. VARIMETER PRO Multifunction Measuring Relay MK 9300N, MH 9300

Andover ContinuumTM Infinet II

Supplement to PM WSC/WDC-1 MicroTech II for Centrifugal Compressor Water Chillers

General information. Display. Supply voltage

Expansion Module HZS 541-1S

MODCELL 2050R Single Loop Controllers

JUMO TYA 201 Single-Phase SCR Power Controller For controlling resistive/inductive loads

Switching and controlling in the switch cabinet

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

RT4F-48V/50A-WAC RECTIFIER

Easy To Use OEMS Take Note

Earth-fault Relay SPAJ 110 C. Product Guide

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

Gladiator Lift Services Ltd OPTIO MRL Controller Specification

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Operator Interfaces Introduction & Selection Guide SELECTION GUIDE INTRODUCTION UCT-31P

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Note: the wiring of the dead-man buttons has been changed since October 2001.

SafeC S. Features. Typical Applications. Technical Data. Principle. Safety Relay

Universal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB

RTD-W Installation Instructions

FrigoPack FU+ New Generation of Intelligent Refrigeration Inverters

Transcription:

Data sheet MK 20 GR Customized solution or off-the-shelf: The choice is yours!

MK20-GR data sheet Looking for a quick and reliable solution? Then rely on our standard products: Our universal controls provide valuable solutions for a wide range of applications. We offer you the benefit from our broad experience of over thirty years. And even with our basic products some variation can be achieved: Each control can be combined with several different types of displays and operating sequences can be configured for individual needs. Standard Product Hardware In the standard version the MK 20 GR offers four analog inputs, eight digital inputs, six digital outputs and one serial interface (RS 485): Two pressure sensors (line pressure, end pressure) can be connected to the two 4-20mA analog inputs Analog inputs no. three and four can be used for two temperature sensors (infineon KTY 11-7 recommended) to continously monitor airend and motor temperature The first digital input is reserved for an emergency stop button. Its activation will stop the compressor immediately. The R-S-I MK 20 GR gives you full control of your air compressor at any time for enhanced protection and complete information at a glance. Two digital inputs are specialized for the use with a PTC. This allows you to monitor for excess motor and airend temperature (or any other temperature you want to keep an eye on) and to stop the compressor in time. No additional thermal overload devices necessary! Each of the remaining five digital inputs are programmable and can be used for external control signals (external on/off, load request, ready) used to communicate with a sequencer, or for external maintenance, warning or fault messages. If an input is configured as external fault, a signal leads to a shut- Customized solution or off-the-shelf: The choice is yours!

MK20 GR data sheet down. Use these inputs to monitor signals of external devices such as dryers or differential pressure switches. The relay outputs no. one, two and three are used for main, star and delta contactor Relay output no. four controls the inlet valve One relay output can be configured. Choose between: ready (compressor is ready to start), running (the motor is running), load (compressor is on load), Relay output no. six can be used to connect an operating or warning lamp. It will be energized if any fault is present. The serial interface (RS 485) can be used for software updates and/or network connection (e.g. for communication with a sequencer) For upgrading: use our plug-in I/O module to connect one or several of our MK 200 modules for additional inputs and outputs. Software The main screen of the MK 20 GR shows actual values of line pressure, end pressure, end temperature and motor temperature as well as the status of the compressor (waiting, ready to start, start up, load/no load, follow up time, soft run-out). The menu structure is secured via a four-digit code. Three code levels provide full security: After entering the user code most parameters can be set. The manufacturers code protects settings critical for a specific compressor. The service code allows to set and reset the hours until the next service. Special features and important parameters of the MK 20 GR: Start and stop pressure: define your individual range for the line pressure Operation mode: choose between continous or automatic Damage prevention: the MK 20 GR protects the compressor by automatically switching it off if the end pressure, the line pressure, the motor or airend temperature exceed the defined limits Configuration of digital inputs and outputs: adjust the MK 20 GR to you individual needs: use it together with a sequencer or create additional warnings or faults to protect your compressor or to monitor external devices Adjustment of the pressure setpoint: save energy by using the integrated timer to automatically change your pressure setpoint or to switch your compressor on and off (e.g. for the weekend) Definition of individual time spans: set your individual star-delta time, follow-up time and soft run-out. Monitoring of the compressor: check any time on actual line and end pressure, motor and airend temperature and compressor status Service reminder: watch operating hours as well as load hours to see the utilization of your compressor. The MK 20 GR provides a warning (or fault) message in time for the next service. Track messages: the failure memory stores all warnings and faults and allows to easier understand occuring problems. Do not worry: useful default values for all parameters prevent damages if parameters have been set incompletely.

16-pole - pitch 3,81 mm MK20 GR data sheet necessary opening in the switch cabinet width x height: 154 x 104 mm depth of controller: 65,5 mm 192,0 mm 169,0 mm diameter 5 mm 43 42 41 digital out (relay) 40 39 2-pole 3-pole 38 37 36 35 34 33 32 31 PE housing (flat connector 6,3 mm) 8-pole 3-pole board (size 148 x 98 mm) 1 2 3 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 power supply 24 V AC digital in Description All-purpose compact control for switch cabinet installation. Includes software for a single stage, oil lubricated, rotary screw compressor. Housing Display Keyboard Front plate: ABS plastics, 192 x 115 mm (w x h) Housing: metal, 104 x 154 x 68,5 mm (h x w x d) Opening in switch cabinet: 154 x 104 mm (recommended) Protection class: front cover IP 55 casing IP 40 Display: Keyboard: LCD graphics display, 128 x 64 pixel membrane keypad with 8 buttons, tactile feedback 1 red failure / alarm LED 1 green operating LED 3-pole pitch 3,81 mm 4 5 6 RS-485 44 45 46 47 48 optional: analog out 8-pole pitch 3,81 mm 7 8 9 10 11 12 13 14 analog in Operating Conditions Power supply: 24VAC / 50-60 Hz Operating temperature: 0... 60 C Humidity at 40 C: max. 95% 115,0 mm

MK20 GR data sheet Digital Inputs 6x 24VDC 2x 12VDC (PTC) Digital Outputs 5x relay, NO (normally open) 230VAC 1x relay, CO (change over) 230VAC Analog Inputs 2x (0)4... 20mA 2x KTY Interfaces RS 485 Connection Screw-type terminal block on the rear side CPU 16 bit, flash memory battery-buffered real-time clock EMC Interference resistence: EN 61000-6-2 Emissions: EN 61000-6-3 Add-ons Plug-in modules: 2AA or I/O MK 200 I/O modules (rail mounted): 8E/4RA 12RA 8E/4AE 4AA 2 analog outputs (0)4 20mA, electrically isolated from CPU bus-module enabling MK 200 I/O add-ons; not in conjunction with 2AA 8x digital inputs, 4x digital (relay) outputs 12x digital (relay) outputs MK 200 communication modules Software 8x digital inputs, 4x analog inputs with measuring amplifier 4x analog outputs (0)4 20mA Software for a single stage oil-lubricated rotary screw compressor. Code-protected menus in English and German. Software-update: reprogramming of flash memory possible Art.-Nr. 002930