R-LB R-LX Series Installation, Operation & Maintenance Manual

Similar documents
DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

HUBBELL SPIKESHIELD Wired-In Branch Panels Surge Protective Device (SPD)

Installation and Operation Manual

INSTALLATION INSTRUCTIONS STZ-R SERIES (ENGLISH)

Hubbell Surge Protective DeviceS

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

GE Digital Energy. Power Quality

TPS3 09. Surge Protective Device. User Manual - USA

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

User Manual - Canada. TPS3 03 DC For DC Photovoltaic Applications. Surge Protective Device

Installation and Operation Manual

TPS3 11. Surge Protective Device. User Manual - USA

Surge Protective Devices. Installation & Operation Manual. Model 457

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Total Home Surge Protection for Point-of-Entry. FirstSurge TM. User Manual - Canada (English)

File E Project 08NK November 24,2009 REPORT TRANSIENT VOLTAGE SURGE SUPPRESSORS (VZCA/VZCA7)

TPS3 Internal Manual. Surge Protective Device. User Manual - Canada

Instruction Manual IM E Table of Contents

SECTION SURGE PROTECTION DEVICES. A. Section includes Surge Protection Devices for low-voltage power, control, and communication equipment.

Surge Protective Devices. Installation & Operation Manual. Model 425

Model 450 Model 451 Model 452 Model 453 Model 460 Model 465 Model 480 Model 485. Surge Protective Devices. Installation & Operation Manual

Surge Protective Devices. Installation & Operation Manual. NEMA 12 (Steel) NEMA 1 (Non-Metallic) Model 350

Specifications, Installation, and Operating Instructions

File E Project 08NK October 2, 2009 REPORT SURGE PROTECTIVE DEVICES (VZCA) GE Zenith Controls Bonham, TX

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Surge Protective Devices Installation, Operation and Maintenance Manual. ServiceTrack ST Series: 080, 120, 160, 200, 240, 300 and 400

Surge Protective Devices. STV25K Series. Instruction Manual

Surge Protective Devices. Installation & Operation Manual. Model 420

Instruction Bulletin Boletín de instrucciones Directives d'utilisation , Rev. 02, 03/2016

Specifications 1 Installation Procedures 2 Wiring Diagrams 3 Installation Checklist 5 Maintenance 5 Warranty Information 6 Material Return Policy 6

Application Techniques CENTERLINE 2100 Motor Control Centers

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

UL th Edition SPD. TPS3 Internal SPDs. User Manual - USA. usa.siemens.com/spd

Total Protection Solutions Surge Protective Devices SurgeTrack Series: 080, 120, 160, 240, 300 and 400

BSPD Surge Protective Devices

TWL Series Installation Guide

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Instruction Manual: IM E

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Quick Start Guide TS A

400 Series 460 Surge Protective Device Installation, Operation and Maintenance Manual

Installation Manual. APEX Series. Silicon and MOV Panel Protection. APEX Series

1. Section Lightning Protection for lightning protection system. D. The installation shall be in conformance with NEC Article 285.

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

300 Series 330/320 Surge Protective Device Installation, Operation and Maintenance Manual

M250 (M LL) Safety

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

for the SPV Installation and Operation Manual Instruction Manual IM E Contents

SURGE PROTECTION USER MANUAL. Surge Protection Device PORTABLE POWER DISTRIBUTION SURGE PROTECTION DEVICE (SPD) B

Always "On" UPS Systems Inc. USER MANUAL

M215 (M215-60) Safety

TPS3 12 & TPS3 15. Surge Protective Device. User Manual - Canada

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

Eaton s SPD Series for integration into electrical distribution equipment

Enphase S-Series Microinverter and Engage Cable Safety

Eaton Innovative TechnologyT XT50/100 surge protective device

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

INSTALLATION INSTRUCTIONS

ADDENDUM INSTALLATION INSTRUCTIONS. Powered In-Wall Storage Boxes. PAC525FxP2 / PAC526FxP2 / PAC526FxP4 / PAC526FxP6

THE SURGE PROTECTION SOLUTION

GE TR7000 Series Wall Mounted Surge Protective Device (SPD)

Installation Instructions & User Manual

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

M215 Safety (M LL-S22-IG / S23-IG / S24-IG)

HP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.

SSMx24 Series 240 ka Per Phase Peak Surge Current ANSI/UL1449 UL Fourth Edition

Liebert INSTALLATION, OPERATION AND MAINTENANCE MANUAL. Interceptor and Interceptor Hybrid Advantage Series Transient Voltage Surge Suppressors

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

Installation Notes TII Model 341 Protector

Installation manual for for Schleifenbauer DPM3

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Measure Ø-N, Ø-Ø, Ø-Gnd with voltmeter to confirm application voltage prior to installation.

Surge Protection Devices (SPD)

Eaton SPD Series. for Mounting External to Electrical Distribution Equipment. Instruction Manual IM E Effective March 2014 Rev.

Electrical Integration of PV Systems. Ridha Hamidi, Ph.D.

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

Models beginning with 2M, 2L or 2X. Product Description. Technical Specifications. Installation Instructions. Series 2000 Multiple Meter Units (MMUs)

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

M215-Z Safety Information (M LL-IG-ZC)

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Instruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C

Operating instructions. Switching amplifier DN0210 DN / / 2015

USER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A

Installation, Operation and Maintenance Manual

Surge Protective Devices. Installation & Operation Manual. Model 335

Installation and Operations Manual. Electronic copies available at (Rev_ )

Eaton SPD Series. Instruction Manual IM E Effective June 2014 Rev. 2

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

White Paper Surge Protective Devices in Automatic Transfer Switches

SAVE THESE INSTRUCTIONS

PanelView Plus/VersaView CE Terminals and Display Modules

MasterMind. MasterMind. Diagnostic Monitoring System For Select and TransGuard Suppression Filter Systems

2.1. SPD, Power Conditioning, PF Capacitors and Harmonic Filters. Contents Description. Introduction. Surge Protection and Power Conditioning

Quick Start Guide TS 870 ATS

SOUTH CAROLINA ELECTRIC COOPERATIVES SECONDARY TYPE 1 SURGE PROTECTIVE DEVICE SPECIFICATIONS Updated/Revised: October 6, 2014

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Transcription:

Installation, Operation & Maintenance Manual WARNINGS Safety First Hazardous Voltage & Shock Hazard Only qualified licensed electricians should install or service SPDs Hazardous voltages exist within SPDs SPDs should never be installed or serviced when energized Use appropriate safety precautions including Personal Protection Equipment Failure to follow these instructions can result in death, serious injury, and/or equipment damage This manual shall be read in its entirety prior to installing Bonding and Grounding Hazard Verify that the neutral conductor in the service entrance equipment is bonded to ground in accordance with the National Electric Code (NEC ) and all applicable codes. During installation into an electrical system the SPD must not be energized until the electrical system is completely installed, inspected and tested. All conductors must be connected and functional including the neutral (if required). The voltage rating of the SPD and system must be verified before energizing the SPD. Failure to follow these guidelines can lead to abnormally high voltages at the SPD. This may cause the SPD to fail. The warranty is voided if the SPD is incorrectly installed and/or if the neutral conductor in the service entrance equipment or downstream of separately derived systems is not bonded to ground in accordance with the NEC. Do Not Hi-Pot Test SPDs Any factory or on-site testing of power distribution equipment that exceeds normal operating voltage such as high-potential insulation testing, or any other tests where the suppression components will be subjected to higher voltage than their rated Maximum Continuous Operating Voltage (MCOV) must be conducted with the SPD disconnected from the power source. For 4-wire systems, the neutral connection at the SPD must also be disconnected prior to performing high-potential testing. Failure to disconnect SPD and associated components during elevated voltage testing will damage the SPD and will void the warranty. SPDs on Ungrounded Systems Caution Ungrounded systems are inherently unstable and can produce excessively high line-toground voltages during certain fault conditions. During these fault conditions, any electrical equipment including an SPD may be subjected to voltages which exceed their designed ratings. An SPD designed specifically for Ungrounded systems should be used. Unpacking & Preliminary Inspection Inspect the entire shipping container for damage or signs of mishandling. Remove the packing materials and further inspect the unit for any obvious shipping damages. If any damage was found and is a result of shipping or handling, immediately file a claim with the shipping company and forward a copy to Raycap. Storage Environment This SPD should be stored in a clean, dry environment. Storage temperature range is -35 C (-31 F) to +75 C (+167 F). Avoid exposure to high condensation. Page 1 of 9

PRE-INSTALLATION Operating Environment The standard unit uses a Type 4 enclosure. Flush-mount kits are available as options. Before installing, ensure that your enclosure type and application are appropriate with regard to moisture, dirt, excessive dust, flammable materials or atmospheres, corrosive vapors, etc. Please consult factory if enclosure needs to be changed. This SPD is designed in an ambient temperature range of -35 C (-31 F) to +75 C (+167 F) with a relative humidity of 0% to 95% (noncondensing). Excessive temperature may inadvertently operate internal thermal overtemperature protectors. Line Side versus Load Side Installation The RSE Series 2 are tested and qualified as Type 1 SPDs per UL 1449 Fourth Edition (cul type 2). This SPD can be installed on the Line Side of the service overcurrent device. Type 1 SPDs may also be installed in Type 2 applications. As a generalization, it is more practical to install as Type 2 on load side of main overcurrent device for maintenance reasons. Audible Noise SPD background noise is negligible or non-existent, and does not restrict the location of installation. Lead Lengths & Maximizing SPD Performance SPDs must be located as close to the circuit as possible to minimize parasitic losses. Use the shortest & straightest possible leads. Pre-Plan installations and ensure that nearest breaker positions are used. If new construction, adjust breaker locations as appropriate. When longer leads are unavoidable, gently twist leads together (one to two twists per foot), or tie-wrap leads together. Voltage Rating Before installing SPD, verify that it has the same voltage rating as the power distribution system. Compare the SPDs nameplate voltage or model number and ensure that SPD configuration matches the intended power source. Circuit Breaker Connected When connected on load side of main disconnect, we suggest connecting via a 60A circuit breaker. The circuit breaker is the intended disconnect switch and provides short circuit protection to the connecting conductors. These SPDs have internal overload protection elements within the product. These SPDs have demonstrated 200kA Short Circuit Current Ratings (SCCRs). Page 2 of 9

System Grounding An equipment grounding conductor must be used on all electrical circuits connected to the SPD. For the best performance, use a single point ground system where the service entrance grounding electrode system is connected to and bonded to all other available electrodes, building steel, metal water pipes, driven rods, etc. (for reference see: IEEE Std 142-2007). For sensitive electronics and computer systems, we recommend that the ground impedance measurement be as low as possible. When metallic raceway is used as an additional grounding conductor, an insulated grounding conductor should be run inside the raceway. Adequate electrical continuity must be maintained at all raceway connections. A separate isolated ground for the SPD is NOT recommended. Proper equipment connections to grounding system and ground grid continuity should be verified via inspections and testing on a regular basis as part of a comprehensive electrical maintenance program. On 4-Wire Power Systems, neutral to ground bonding (Main Bonding Jumper) must be installed per the NEC. Failure to do so WILL damage SPDs. UL 1283 required language concerning the installation of EMI Filters a) An insulated grounding conductor that is identical in size and insulation material and thickness to the grounded and ungrounded circuit supply conductors, except that it is green with or without one or more yellow stripes, is to be installed as part of the circuit that supplies the filter. Reference should be made to Table 250-122 of the National Electrical Code regarding the appropriate size of the grounding conductor. b) The grounding conductor mentioned in item a is to be grounded to earth at the service equipment or other acceptable building earth ground such as the building frame in the case of a high-rise steelframe structure. c) Any attachment-plug receptacles in the vicinity of the filter are to be of a grounding type, and the grounding conductors serving these receptacles are to be connected to earth ground at the service equipment or other acceptable building earth ground such as the building frame in the case of a high-rise steel-frame structure. d) Pressure terminal or pressure splicing connectors and soldering lugs used in the installation of the filter shall be identified as being suitable for the material of the conductors. Conductors of dissimilar metals shall not be intermixed in a terminal or splicing connector where physical contact occurs between dissimilar conductors unless the device is identified for the purpose and conditions of use. Retro-fit Into Existing Panel with No Available Breaker Positions Follow all applicable Codes: Consider consolidating loads in a manner that might free breaker positions. A ten foot tap rule in NEC 240.21(B)(1) allows you to tap the bus as long as the tap conductors are rated at least 10% of the ampacity of the panel. In the case where the ampacity of the panel is larger the wires of the SPD, consider tapping the bus per NEC 240.21(B)(1) and running appropriate size conductors to a safety switch fused to 60A. Mount the SPD immediately adjacent to the safety switch. Page 3 of 9

INSTALLATION Pre-Plan your installation Meet all National and Local codes. (NEC Article 285 addresses SPDs) Mount SPD as close to panel or equipment as possible to keep leads short Ensure leads are as short and straight as possible, including neutral and ground. Consider a breaker position that is closest to the SPD and the panel s neutral & ground Suggested breaker size is 60A-40A Make sure system is grounded per NEC and clear of faults before energizing SPD Connect to Mains Connect to Alarming black white green Line(s) Neutral Ground black brown yellow NO (Normally Open) NC (Normally Closed) Common 1. Use a voltmeter to check all voltages to ensure correct SPD. 2. If SPD has Dry Contact, pre-plan their installation. 3. Remove power for panel. Confirm panel is deenergized. 4. Identify connection/breaker location and SPD location. 5. Make sure leads are short. 6. Remove an appropriately sized knockout from panel. 7. Mount SPD. Connect to equipment using an approved wiring method, including seals appropriate for the enclosure rating. 8. Connect conductors as appropriate short and straight as possible. (Note that Hi-Legs are Phase B). 9. Label or mark conductors as appropriate Energized: black Neutral: white Ground: green Hi-Leg (Delta units only): orange 10. Make sure system is bonded per NEC and is clear of hazards or faults before energizing (N-G bonding not per NEC will fail SPDs: #1 cause of SPD failures). 11. Energize and confirm proper operation of indicators and/or options. If Red LED flashes & Audible Alarm cycles, deenergize immediately and call for help. Page 4 of 9

OPERATION LED Operation EEach SPD contains 2 dual color LEDs per phase shown in the appropriate voltage configuration. True 10-mode versions will have 3 LEDs per phase. When the LEDs are green complete protection is present. During partial MOV stack failure the LED will change state to Amber. Upon full MOV stack failure the LED will change state to red. During any failure the Red Service LED will illuminate. (For optional Advanced Diagnostics, LED will illuminate during Temporary Overvoltage (TOV) and Surge Events. Audible Alarm Similar to the LEDs the Audible Alarm will sound upon suppression element failure. LCD Panel Operation Screen Saver Immediately on power-up of the SPD the scrolling screen saver will be shown. When any of the buttons are pressed the SPD will stop showing the screen saver and advance to the Main Screen. After 5 minutes without user activity the screen saver will be displayed again. Main Screen The Main Screen is the starting point for navigating through the SPDs menus. It will also show the logged data for the most recent event and the current time and date. Pressing the right button (STATS) will move to the Statistics screen. Pressing the left button (MENU) will move to the Main Menu screen. Statistics Screen Menu, About Screen, and the System Screen. Use the UP/DOWN buttons to select the menu or screen of interest. Pressing the left button (BACK) will return you to the Main Screen. Pressing the right button will advance you to the menu or screen you have selected. Page 5 of 9

Main Menu Screen The Main Menu Screen will allow you to navigate to the Setup Menu, Event Menu, About Screen, and the System Screen. Use the UP/DOWN buttons to select the menu or screen of interest. Pressing the left button (BACK) will return you to the Main Screen. Pressing the right button will advance you to the menu or screen you have selected. Setup Menu Screen The Setup Menu Screen will allow you to set the time and date of the SPD. Accurately setting the date and time is very important for this SPD. All events are recorded with a timestamp. Use the UP/DOWN buttons to select whether to adjust the time or the date. Pressing the left button (BACK) will return you to the Main Menu Screen. Pressing the right button will advance you to the menu or screen you have selected. Adjust Date Screen The Adjust Date Screen will allow you to set the date of the SPD. Use the UP/ DOWN buttons to adjust the value in the selected field until you have the correct value. Pressing the LEFT button (NEXT) will advance the cursor to the next date field. Pressing the Right button (DONE) will finalize you changes and save them to the SPD memory. You will automatically be brought back to the Setup Menu. Adjust Time Screen The Adjust Time Screen will allow you to set the time of the SPD. Use the UP/ DOWN buttons to adjust the value in the selected field until you have the correct value. Pressing the LEFT button (NEXT) will advance the cursor to the next time field. Pressing the Right button (DONE) will finalize you changes and save them to the SPD memory. You will automatically be brought back to the Setup Menu. Event Menu Screen The Event Menu Screen will allow you to review the SPD s TOV and Surge event history or clear it. Use the UP/DOWN buttons to select which operation to perform. Pressing the left button (BACK) will return you to the Main Menu Screen. Pressing the right button will advance you to the screen you have selected. Page 6 of 9

Event History Screen The Event History Screen will allow you to review each event the SPD has on record. Use the UP/DOWN buttons to scroll through the event log. Pressing the left button (BACK) will return you to the Event Menu Screen. Pressing the right button (CLEAR) will send you to the Clear Event History Screen. Clear Event History Screen The Clear Event History Screen will allow you to clear the SPD s event log. Pressing the left button (YES) will clear the event log. Pressing the right button (NO) will keep the current event log intact. Either operation will return you to the Event History Screen. About Screen From the Main Menu screen the About Screen can be accessed to display the manufacturer s information, the model number, and the serial number for this specific SPD. Pressing the left button (back) will return you to the Main Menu Screen. System Info Screen The System Screen displays the important electrical information for this system. This includes the nominal operating voltage, System configuration (ie. Wye, Delta, Single Phase) and maximum current rating for each mode of the SPD. The processor serial number, firmware edition, build and test dates are also shown on this page. Pressing the left button (back) will return you to the Main Menu Screen. Page 7 of 9

System Event Alarms Surge Event When the SPD detects a surge event the Surge Detected animation will be shown. It will remain on screen until acknowledged by an operator. Any subsequent events that occur while the Surge event animation is on screen will be registered and queued for acknowledgment. Along with displaying the Surge animation, the Audio alarm will sound and the Form C dry contacts will change state. Pressing the left button (INFO) will display additional information about the event. Pressing the right button (CANCEL) will acknowledge the event and silence the alarms. Temporary Over Voltage Event When the SPD detects a Temporary Over Voltage Event (TOV) the TOV Detected animation will be shown. It will remain on screen until acknowledged by an operator. Any subsequent events that occur while the TOV event animation is on screen will be registered and queued for acknowledgment. Along with displaying the TOV animation, the Audio alarm will sound and the Form C dry contacts will change state. Pressing the left button (INFO) will display additional information about the event. Pressing the right button (CANCEL) will acknowledge the event and silence the alarms. Extended TOV Event In the event of an operator attempting to clear a TOV Detected event while the TOV event is still occuring, the TOV IN Progress screen will be displayed. Page 8 of 9

Mode Disconnection When the SPD detects a MOV disconnection the Mode Disoconnect animation will be shown. It will remain on screen until acknowledged by an operator. Any subsequent events that occur while the disconnection event animation is on screen will be registered and queued for acknowledgment. Along with displaying the disconnection animation, the Audio alarm will sound and the Form C dry contacts will change state. A corresponding LED will also change state during an MOV disconnection. Pressing the left button (INFO) will display additional information about the event. Pressing the right button (CANCEL) will acknowledge the event and silence the alarms. Power Outage Should the SPD be subjected to a power outage this animation will be shown. It will remain on screen until acknowledged by an operator. Any subsequent events that occur while the power outage event animation is on screen will be registered and queued for acknowledgment. Along with displaying the power outage animation, the Audio alarm will sound and the Form C dry contacts will change state. Pressing the left button (INFO) will display additional information about the event. Pressing the right button (CANCEL) will acknowledge the event and silence the alarms. This SPD s timekeeping is equipped to survive several days of a power outage. When power returns the SPD will record the date and time of the power loss and when power was restored. Should the SPD be exposed to an extended power outage the SPD s time and date should be checked for accuracy. On initial installations where power may be cycled several times. The power outage alarm is is designed to be suspended unitl the SPD has been energized for at least 1 hour. Dry Contact Three 3' 18 AWG wires are included through the nipple as the Dry Contacts. Please note: Dry Contacts are designed for low voltage or control signals only. Maximum switching current is 5A Maximum switching voltage is 240V DC or AC. Higher energy applications require additional relay implementation outside the SPD. Gray is Common, Blue is Normally Open and Red is Normally Closed. If the Dry Contacts are not utilized, insulate lead ends, coil and secure. MAINTENANCE SPDs require minimal maintenance. We recommend periodic inspection of diagnostic indicators to ensure proper operation. We also recommend keeping the SPD clean as appropriate. Troubleshooting & Service Please contact us for any service related issues. We want to take care of any problems. Page 9 of 9