Connect array to Cisco UCS and VMware vsphere

Similar documents
UCS with VMware ESXi End to End Jumbo MTU Configuration Example

vsphere Networking Update 1 ESXi 5.1 vcenter Server 5.1 vsphere 5.1 EN

AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide

Configuring Server Boot

10GbE Network Configuration

Managing ReadyClones

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

vsphere Networking Update 2 VMware vsphere 5.5 VMware ESXi 5.5 vcenter Server 5.5 EN

UCS deployment guide for Nimble Storage

Multipathing Configuration for Software iscsi Using Port Binding

Reference Architecture. DataStream. UCS Direct Connect. For DataStream OS 2.6 or later Document # NA Version 1.08 April

Migrating Hosts to the Cisco Nexus 1000V Using Cisco Virtual Switch Update Manager, page 3

Basic Configuration Installation Guide

Basic Configuration Installation Guide

Cisco CCIE Data Center Written (Beta) Download Full Version :

Configuring and Managing Virtual Storage

Configuring Global Service Profiles

Using a Virtual Machine for Cisco IPICS on a Cisco UCS C-Series Server

How to Deploy vcenter on the HX Data Platform

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

Administering VMware vsphere and vcenter 5

Open-E DSS V6 MPIO with VMware ESX 4.0

Installing the Cisco CSR 1000v in VMware ESXi Environments

VMware vsphere 5.5: Install, Configure, Manage Lab Addendum. Lab 3: Configuring VMware ESXi

Server Pools. Server Pools. Creating or Editing a Server Pool

Configuring Cisco UCS Server Pools and Policies

VMware vsphere with ESX 6 and vcenter 6

Cisco VDS Service Broker Software Installation Guide for UCS Platforms

Configuring Server Boot

Setting Up Cisco Prime LMS for High Availability, Live Migration, and Storage VMotion Using VMware

vsan Network Setup January 09, 2018

Using SANDeploy iscsi SAN for VMware ESX / ESXi Server

Setting the Management IP Address

VersaStack for Data Center Design & Implementation (VDCDI) 1.0

vsphere Networking Update 1 Modified on 04 OCT 2017 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

VMware ESX ESXi and vsphere. Installation Guide

Configuring High Availability for VMware vcenter in RMS All-In-One Setup

vsphere Networking 17 APR 2018 VMware vsphere 6.7 VMware ESXi 6.7 vcenter Server 6.7

NS0-171.network appliance

Global Pools. Server Pools. Creating a Server Pool. This chapter includes the following sections:

Installation of Cisco Business Edition 6000H/M

Cryptzone AppGate. AX-V Virtual Appliance Getting Started Guide. Context Aware. Content Secure.

VMware vsphere with ESX 4.1 and vcenter 4.1

Orchestration Workflow Tasks for PXE Boot

Configuring Service Profiles

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation

FlexPod Datacenter with SolidFire All-Flash Array Add-On

Cisco. Exam Questions DCUCI Implementing Cisco Data Center Unified Computing (DCUCI)

Use Cisco UCS Connectivity Policies to Achieve Strict Administrative Role Delineation

Setting the Management IP Address

CISCO EXAM QUESTIONS & ANSWERS

Cisco ACI with Cisco AVS

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability with VMWare vsphere and ESX server

Managing Virtual Machines Using the Cisco SRE-V CLI

DELL POWERVAULT MD32XXI / MD36XXI DEPLOYMENT GUIDE FOR VMWARE ESX4.1 SERVER SOFTWARE

iscsi Configuration for ESXi using VSC Express Guide

Cisco HyperFlex Systems

UC Voice Application Connectivity in a VMware UCS Environment

Service Profiles. Service Profiles in UCS Manager

GV STRATUS Virtualized Systems. Alex Lakey November 2016

Cisco UCS Director Tech Module Cisco UCS Manager (UCSM)

Implementing VMware vsphere 5 Auto Deploy on the Cisco Unified Computing System

UCS Nirvana. Lee Burleson Network and Systems Engineer Iowa National Guard. Cisco ARNG Training Event March 2011

Cisco ACI and Cisco AVS

This article describes how to upgrade CS200 and CS400 series Nimble Storage arrays from 1 GigE to 10 GigE connectivity.

Dell EMC. VxBlock and Vblock Systems 540 Administration Guide

Configuring Cisco UCS Server Pools and Policies

Managing Virtual Machines

Cisco UCS Director Tech Module EMC XtremIO

Downloading and Installing Cisco UCS VIC Drivers

Preparing Virtual Machines for Cisco APIC-EM

Preparing Virtual Machines for Cisco APIC-EM

Security Gateway Virtual Edition

EMC CLARiiON iscsi Server Setup Guide for VMware ESX Server 3i and 3.x Hosts

DELL POWERVAULT MD3200I / MD3600I DEPLOYMENT GUIDE FOR VMWARE ESX4.1 SERVER SOFTWARE

Introducing Cisco UCS Central 2.0

Cisco Actualtests Questions & Answers

CISCO EXAM QUESTIONS & ANSWERS

Direct Attached Storage

Managing VMware vcenter Site Recovery Manager

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Introducing Cisco UCS Central 1.3

Mapping Cisco CSR 1000v Network Interfaces to VM Network Interfaces, page 1

Installation. Power on and initial setup. Before You Begin. Procedure

vsphere Host Profiles 17 APR 2018 VMware vsphere 6.7 VMware ESXi 6.7 vcenter Server 6.7

FlexPod Express with VMware vsphere 6.0U2, NetApp E-Series, and Cisco UCS Mini

VMware vsphere with ESX 4 and vcenter

Configuring Network-Related Policies

UCS Direct Attached Storage and FC Zoning Configuration Example

HYPER-UNIFIED STORAGE. Nexsan Unity

StarWind iscsi SAN & NAS:

FlashStack Virtual Server Infrastructure Deployment Guide: Cisco PowerTool Addendum

Configuring Microsoft SCVMM

Dell EMC. VxBlock and Vblock Systems 350 Administration Guide

RecoverPoint for Virtual Machines

Installing on a Virtual Machine

Qsan Document - White Paper. How to configure iscsi initiator in ESXi 6.x

Remote PC Guide Series - Volume 2

Introducing Cisco UCS Central 1.4

StarWind iscsi SAN & NAS: Configuring 3-node HA Shared Storage for vsphere December 2012

Transcription:

Summary This article provides a step-by-step guidance to setup a Cisco UCS with a Nimble Storage iscsi array and VMware vsphere. Note: This document does not cover any boot from SAN configuration. Setup NICs and VLANs in UCS Manager Click on the LAN tab and right-click on VLANS and select Create VLANs. Specify a VLAN Name/Prefix and select Common/Global option below. Also, please enter a VLAN ID. Page 1 of 12

Once the VLAN has been created, we need to create a new VNIC template. Navigate to the LAN tab and select VNIC templates and click on add. We need to create a VNIC template for FI-A and FI-B to allow multiple paths to our array to ensure MPIO and higher throughput. Page 2 of 12

Fabric A and B need to have separate vnic templates. When creating a vnic template, please ensure to select a MAC Pool. If you did not create a new MAC Pool, you can use the default MAC Pool. OPTIONAL STEP create a new MAC Pool: Click on the LAN tab and select Pools. Right-click on MAC Pools and select Create new MAC Pool. Page 3 of 12

Specify a name for the MAC Pool and whether you want the MAC addresses to be sequential or randomly assigned. Page 4 of 12

Next, we need to specify the first MAC address and the size of the MAC Pool. Once both have been specified, click on finish and your MAC Pool will be created. So far we have created a new VLAN and two new vnic templates. In the next step, we will create actual vnics within the assigned Service Template and use our vnic templates. Page 5 of 12

Click on the tick box Use LAN Connectivity Template which will use our pre-configured vnic templates. Add a name, select the vnic template and use the VMware Adapter Policy. After we have created our vnics, the blades need to be rebooted in order to get the vnics added. Setup VMware vsphere to connect to the array We need to create a new vswitch which will use our iscsi vnics which we have created earlier. Select your VMware ESXi host in the Inventory within vcenter and go to Configuration and then Networking. Page 6 of 12

Add a new VMkernel port and add both NICs which were create within UCS. Create a name for the first iscsi VMkernel port. (We recommend using iscsi-0x for the name) Add the IP address and subnet mask of the first iscsi VMkernel adapter, click next and then Finish. Page 7 of 12

Now, we need to configure a second iscsi VMkernel adapter. On our newly created vswitch, click on Properties. Click on Add and run through the previous steps on how to add a VMkernel port again. Page 8 of 12

After both VMkernel ports have been created, select the first VMkernel port (iscsi-0x) and click on Edit. On the NIC Teaming tab, select Override switch failover order for our VMkernel port and make sure that only one NIC is active and the other one is set to unused. The same needs to be done for the second VMkernel port. Page 9 of 12

Once the vswitch is configured correctly we can add the Software iscsi Adapter, on the Storage Adapter section in the Configuration tab by clicking Add. Click on Add Software iscsi Adapter. After the Software iscsi Adapter has successfully been added, select the adapter under Storage Adapters and click on Properties. Go to the Network Configuration Tab and add both VMkernel adapters. Page 10 of 12

Once both adapters are added the Network Configuration Tab should show both adapters. Now we need to add our iscsi Discovery IP of the array within the Dynamic Discovery Tab. Page 11 of 12

Click on ok and close. The host will prompt you to do a rescan on the Software iscsi Initiator. After the rescan completed, select the vmhba33 (iscsi Software Adapter). You should see all volumes, which are presented from the array to the host, and two paths per volume. (end of document) Page 12 of 12