POCKET MULTIMETER Model No: MM18

Similar documents
WARNING CAUTION 1. SAFETY

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

ETHOS Auto Ranging Digital Multimeter

Digital Multimeter User's Manual

Mini Digital Multimeter

Mini Digital Multimeter

9040/9040UK. Users Manual. Phase Rotation Indicator

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER MAS830 MAS830L

Autoranging True RMS Multimeter User Manual

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

User's Guide. Digital Multimeter. Model MN42

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Mini Digital Multimeter

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

7032 Digital-Analog Multimeter

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

OPERATING INSTRUCTION

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

2 in 1 LAN Tester and Multimeter Model:

Variable Temperature Digital Solder and Testing Station

Mini Digital Multimeter Model MN15. User's Guide

Model A Mini AC/DC Clamp Meter. User's Guide

AutoRanging Digital MultiMeter

User Guide True RMS Multimeter Extech EX205T

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

User s Guide. 600A AC Clamp Meter. Model 38387

User's Guide. Extech AM A AC Analog Clamp Meter

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

OPERATING INSTRUCTION. Pen-Type Digital Multimeter

Autoranging Mini Multimeter

Model R5010. TRMS Digital Multimeter. Instruction Manual

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

User's Guide. Phase Sequence and Motor Rotation Tester Model

Model 3526-B Digi-Probe Multimeter

POCKET MULTIMETER 5115 ENGLISH User Manual

MTP INSTRUCTION MANUAL

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

OPERATING INSTRUCTIONS

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

True RMS Digital Bench Multimeter Model:

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

CLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

Digital Clamp Meter User Manual

User's Guide. Digital Multimeter plus IR Thermometer. Extech 450 Patented

General Warranty. For more details, please refer to the user manual, it can be downloaded at

Instruction Manual. 2in1 LAN Tester & Multimeter. Model: 57314

USER MANUAL. True RMS Multimeter. Extech EX430A

USER'S MANUAL DCL-650

Operating Instructions

Operating Instructions

Earth Resistance and Resistivity Tester

Solar Installation PV100 Operating Instructions

2 in1 LAN Tester & Multimeter. Model: PCE-LT 1

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Bench Multimeter. Users Manual

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

Autoranging Mini Multimeter Model MN16A

Digital Clamp-on Meter Instruction Manual

True RMS Multimeter with IR Thermometer

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

Autoranging Multimeter plus IR Thermometer Extech 450 Patented

Mini Multimeter with Non-Contact Voltage Detector (NCV)

EARTH RESISTANCE & RESISTIVITY TESTER

Autoranging Multimeter Extech EX503

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

True RMS Multimeter with IR Thermometer

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

700 Series 200 Amp Clamp Meters

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

ENGLISH. User manual.

True RMS Industrial Multimeter Extech EX530

User's Guide. True RMS Multimeter plus IR Thermometer. Extech 470 Patented

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

LINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.

Industrial Multimeter Extech EX510

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

General Warranty. For more details, please refer to the user manual, it can be downloaded at

Wireless TRMS Multimeter and Insulation Tester

TT-SI 50 50MHz DIFFERENTIAL PROBE USER S MANUAL

200B-G Tone Probe. 200EP-G Tone Probe INSTRUCTION MANUAL. with Adjustable Volume

True RMS Industrial Multimeter Extech EX520

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

USER MANUAL. True RMS Multimeter plus IR Thermometer. Extech EX470A

HV-CS kv Edge Mount Triaxial Jack

TA330 HAND HELD AUTOMOTIVE SINGLE CHANNEL OSCILLOSCOPE AND MULTIMETER

Installation Guide. QBox-V6. Standalone/Spare V6 SDI QBox. Standalone/Spare V6 SDI QBox. Part No. A

Transcription:

INSTRUCTIONS FOR: POCKET MULTIMETER Model No: MM18 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE. 1. SAFETY INSTRUCTIONS 1.1. PERSONAL PRECAUTIONS When using this multimeter, please observe all normal safety rules concerning: Protection against the dangers of electrical current. Protection of the meter against misuse. Full compliance with safety standards can only be guaranteed if used with the test leads supplied. If necessary, they must be replaced with genuine Sealey leads with the same electrical ratings. Failure to do so will invalidate the warranty. DO NOT use leads if damaged or if the wires are bared in any way. 1.2. GENERAL SAFETY INSTRUCTIONS Familiarise yourself with the application and limitations of the multimeter as well as the potential hazards. IF IN ANY DOUBT CONSULT A QUALIFIED ELECTRICIAN. USE EXTREME CAUTION when working with high voltages. DO NOT use the meter if it is damaged. Before you use it inspect the case. Pay particular attention to the insulation surrounding the connectors. Inspect the test leads for damaged insulation or exposed metal. Check the test leads for continuity. Replace damaged test leads before you use the meter. DO NOT use the meter if it operates abnormally. Protection may be impaired. When in doubt have the meter inspected by your Sealey Authorised Dealer. DO NOT operate the meter where explosive gas, vapour or dust is present. DO NOT apply more than the rated voltage, as marked on the meter, between the probes or between any probe and earth ground. Before use verify the meter's operation by measuring a known voltage. When measuring current, turn off circuit power before connecting the meter in the circuit. Remember to place the meter in series with the circuit. WARNING Use caution when working with voltage above 30V ac rms, 42V peak, or 60V dc. Such voltages pose a shock hazard. When using the probes keep your fingers behind the finger guards. When making connections, connect the black test lead before you connect the red test lead. When you disconnect the test leads, disconnect the red one first. Remove the test leads from the circuit under test before you open the back cover. DO NOT operate the meter with the back cover removed or loosened. To avoid false readings, which could lead to possible electric shock or personal injury, replace the button cells as soon as the low battery indicator ( ) appears. DO NOT touch any naked conductor with your hand or skin, to avoid electric shock, DO NOT ground yourself whilst using the meter. When a probe is connected to a dangerous live potential, it must be noted that this potential can occur at the other probe. NOTE CAT II measurement category is for measurements performed on circuits directly connected to low voltage installations. (Examples are measurements on household appliances, portable tools and similar equipment.) DO NOT use the meter for measurements within Measurement Categories III and IV. Disconnect circuit power and discharge all capacitors before testing resistance, diode or continuity. Use the proper function for your measurements. Before measuring current, check the meter's fuse and turn off power to the circuit before connecting the meter to the circuit. Before moving the function switch or rotating the range switch, disconnect the test leads from the circuit under test. The user shall ensure that test probes are correctly selected in order to prevent danger. Probes shall be selected to ensure that adequate barriers guard against inadvertent hand contact with live conductors under test and that probes have minimal exposed probe tips. Where there is a risk of the probe tip short circuiting with other live conductors under test, it is recommended that the exposed tip length shall not exceed 4mm. NOTE:The warnings, cautions and instructions referred to in this manual cannot cover all possible conditions and situations that may occur. It must be understood that common sense and caution are factors which cannot be built into this product, but must be applied by the operator. 1.3. ELECTRICAL SYMBOLS Alternating Current. Direct Current. Both direct and alternating current. Caution risk of danger refer to operating manual before use. Caution risk of electric shock. Earth (ground) terminal. Fuse. The equipment is protected throughout by double insulation or reinforced insulation.

2. FEATURES Handy compact unit, small enough to fit in your pocket, making it ideal for basic circuit testing on the move. Features flip lid for added screen protection and storage of leads. Conforms to EN 61010-1 CAT II safety requirements. Supplied with test leads. Measures: AC and DC Voltage DC Current Resistance Audible Continuity 1. Display 3½ digit LCD, with a max. reading of 1999. 2. Function Used to select desired function. 3. Range Switch Used to select desired range. 4. Test Probes 3. SPECIFICATION Model No:... MM18 Measures: Voltage DC:... 2V, 20V, 200V, 250V (±1.0%) Voltage AC:... 250V (±1.2%) Current DC:... 200mA (±1.2%) Resistance:... 2k Ω, 20k Ω, 200k Ω, 2000k Ω (±1.2%) Continuity Audible:... Yes Digits x Height:... 5 x 11mm Batteries (Supplied):... 2 x 1.5V Size (L x W x H):... 114 x 56 x 23mm Weight:... 101g Conformity:... EN 61010-1 Operation Environment:... 0 C to 40 C Relative Humidity:... <75% Storage Temperature:... -10 C to 50 C Relative Humidity:... <85% DC VOLTAGE 2V 0.001V 20V 0.01V AC VOLTAGE 200V 0.1V 250V 1V ±(1.2% +10 digits) 200V 0.1V ±(1.0% +5 digits) 250V 1V Input Impedance: 1MΩ Max. Allowable Input Voltage: 250V dc Input Impedance: Frequency Range: Max. Allowable Input Voltage: Response: About 500kΩ 40Hz to 400Hz 250V ac rms Average, calibrated in rms of sine wave DC CURRENT RESISTANCE 200mA 0.1mA ±(1.2% + 5 digits) 2kΩ 0.001kΩ 250mA/250V Fast fuse 20kΩ 0.01kΩ 200kΩ 0.1kΩ ±(1.2% +5 digits) 2000kΩ 1kΩ Max Open Circuit Voltage: About 0.4V 250V DC/AC rms

DIODE AND CONTINUITY Range Description Remark The display shows the approx. forward Open Circuit Voltage voltage drop of the diode. about 2.5V Max. Test Current: 1mA The built in buzzer will sound if the resistance is less than about 30Ω. The buzzer may not sound if the Open Circuit Voltage resistance is between 30Ω and 100Ω. about 2.5V The buzzer will not sound if the resistance is more than 100Ω. 250V DC/AC rms

4. OPERATING INSTRUCTIONS 4.1. MEASURING DC VOLTAGE 4.1.1. Set the function switch to the V position. 4.1.2. Set the range to the desired position. If the magnitude of the voltage to be measured is not known beforehand, set the range switch to the highest range first and then reduce it range by range until satisfactory resolution is obtained. 4.1.3. Connect the test leads across the source or circuit to be tested. 4.1.4. Read the reading on the display. The polarity of the red test lead connection will be indicated as well. NOTE To avoid electric shock to you or damage to the meter, DO NOT measure a voltage higher than 250V. 4.2. MEASURING AC VOLTAGE 4.2.1. Set the function switch to the V position. 4.2.2. Set the range switch to 250V or 200V range position. 4.2.3. If the magnitude of the voltage to be measured is not known beforehand, set the range to the highest first and then reduce it until a satisfactory resolution is obtained. 4.2.4. Read the reading on the display. NOTE To avoid electric shock to you or damage to the meter, DO NOT measure a voltage higher than 250V. 4.3. MEASURING DC CURRENT 4.3.1. Set the function switch to A position. 4.3.2. Set the range switch to the 200mA range position. 4.3.3. Turn off the circuit to be tested. Then discharge all capacitors. 4.3.4. Break the circuit path to be tested, then connect the test leads in series with the circuit. 4.3.5. Turn on the power to the circuit, then read the reading on the display. The polarity of the red test lead connection will be indicated as well. 4.4. MEASURING RESISTANCE 4.4.1. Set the function switch to position. 4.4.2. Set the range switch to the desired resistance measuring range position. 4.4.3. Connect the test leads across the object to be measured. 4.4.4. Read the reading on the display. NOTE: 1. For measurements > 1MΩ, the meter may take a few seconds to stabilise a reading. This is normal for high resistance measurements. 2. When the test leads are in open circuit state, 1 will be dsplayed as an overrange indication. 3. Before measurement, disconnect all power to the circuit to be tested and discharge all capacitors thoroughly. 4.5. DIODE TEST 4.5.1. Set the function to the position. 4.5.2. Set the range switch to the position. 4.5.3. Connect the red test lead to the anode of the diode to be tested and the black lead to the cathode of the diode. 4.5.4. The display shows the approximate forward voltage drop of the diode. If the connection is reversed, 1 will be shown on the display. 4.6. CONTINUITY TEST 4.6.1. Set the function switch to the position. 4.6.2. Set the range switch to the position. 4.6.3. Connect the test leads across the circuit to be tested. 4.6.4. If the resistance is less than about 30Ω, the built in buzzer will sound. NOTE Before test, disconnect all power to the circuit to be tested and discharge all capacitors thoroughly. 5. MAINTENANCE 5.1. Periodically wipe the case with a damp cloth and mild detergent. DO NOT use abrasives or solvents. 5.2. BATTERY AND FUSE REPLACEMENT 5.2.1. When the symbol appears on the display, the batteries are low and must be replaced immediately. To replace the batteries remove the screws in the back cover and remove the back cover. Remove the batteries and replace with batteries of the same type (1.5V button cell LR44 or equivalent). Make sure the polarity connections are correct (see the indication on the bottom of each cell compartment). Reinstall the back cover and its screws. The fuse rarely needs to be replaced and is blown as a result of operator s error. To replace the fuse, remove the back cover (see above) replace the fuse with one of the same rating. Reinstall the back cover and its screws. This meter uses 250mA/250V, fast, Ø5x20mm fuse. WARNING Remove all leads from the circuit under test before opening the back cover.

Environmental Protection. Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycle centre and disposed of in a manner which is compatible with the environment. WEEE Regulations. Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment. When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid waste authority for recycling information. Battery Removal. WARNING! To avoid electric shock, disconnect the test leads from any source of voltage before removing the battery door. Disconnect the test leads from the meter. Open the battery cover by loosening the two cover screws using a cross head screwdriver (see picture below and refer to 5.2.1. above). Replace the battery cover back in place. Secure with the screws. WARNING! To avoid electric shock, do not operate the meter until the battery cover is in place and fastened securely. Dispose of batteries according to local authority guidelines. Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential purchasers of products containing batteries (as defined within these regulations), Jack Sealey Ltd s Batteries Producer Registration Number (BPRN) is BPRN00705. NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product. WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim. INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode. Sole UK Distributor, Sealey Group, Kempson Way, Suffolk Business Park, Bury St. Edmunds, Suffolk, IP32 7AR 01284 757500 01284 703534 www.sealey.co.uk sales@sealey.co.uk