Connecting the EN-4000 to DC Power

Similar documents
WRT4000 Series Cellular Wireless Routers

Snap Server 4400 Power Supply

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

(Catalog Numbers 1394-FK10TS and -FK22TS)

enetworks TM C2C Hardware Description and Specifications A.1 C2C Chassis Hardware Description

Perle MCR200 Installation Guide

Using the EN-2000 s Management System

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Rack Installation Instructions

PLC Racks IC697CHS782/783

Replacing the Power Supply

Installing and Removing SDRAM and DRAM

Power Supply and Fan Module Installation

Installing the Cisco 2524 and Cisco 2525 Routers

Installing the EN-4000

Configuring General Settings for the EN-4000

Installing the Cisco AS5400XM Universal Gateway

G12/G12x USER S MANUAL

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

System Storage EXP3000 Rack Installation Instructions

Replacing the SATA PCI Controller Card

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

Docking Cradle User s Guide

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

LED. Sign Module. Assembly Manual

Power Supply Installation

Installing Keypad and Backplate

CONTENTS. 1. Motherboard installation Install 5¼ and 3½ drives Install PCI components Case fan setup...5

VL BPC 100. Valueline configurable box PC. Data sheet 3063_en_E. 1 Description. 2 Features

EMC1600 Series Media Converter and Ethernet Extender Chassis

Replacing the Battery HP t5730 and t5735 Thin Clients

Installing and Upgrading Memory and Virtual Private Network Modules

TrueNAS Z SERIES NODE SATADOM REPLACEMENT KIT. August 2017 Edition

Product names mentioned in this manual may be trademarks or registered trademarks of those products.

BANDIT II Hardware Description

MPP200 User s Manual

Megatouch FORCE Monitor Chassis Board Replacement

AlphaServer DS20 Ultra SCSI Internal StorageWorks Shelf Configuration Guide

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

VL BPC MINI. A configurable industrial computer platform Intel Atom Z510PT CMAT IPC Module Option [I28] AUTOMATION Data Sheet 2930_en_A.

PoE/FPR Kit for Auto-Sync Time Clock. The Auto-Sync Time Clock is a validated time system with a Web interface and auto discovery.

CONEC Industrial Ethernet Circular Sealed RJ45 Connector System consists of a RJ45 Plug Kit, a Receptacle Kit and a Protective Cover Assembly.

Cisco ONS CL Shelf Assembly Hardware

Mid-span 802.3af PoE Injector. Installation Guide KPOE-100

GPIB-232CT-A IBCL EPROM Installation Guide

PACSystems RX7i IC698CHS009/119

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR065-48S / OPR065-48R. Manual

7403 K321. Display Wall Mount. Kit Instructions. Issue A

Replacement Instructions. Backplane PCA for the HP Router 650

CMSA-100 Manual. Cinema Media Server Automation

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

LED Maintenance Instructions

TRC-190 User s Manual

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

CVH Slot Media Converter Chassis Quick Installation Guide

Preface. Media Converter

Upgrading and Servicing Guide

! encor e networks TM

Configuring the EN-2000 for its Network Functions

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

N3150 Installation and Setup Instructions

Monitoring the EN-4000

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Quantum DXi6802 and DXi690x: Power Supply Replacement

Fortel FRM-501 Compact System Frame User Manual

Field Service Guide Supplement for the NS 7000/030

Signamax Connectivity Systems Industrial Ethernet Extender. User s Guide

Assembly Instructions

TABLET DOCK USER S GUIDE

TDM To MiniMech conversion ProceDure

Installation Instructions

E1135C PDU and Pod Upgrade Procedure

Perle SMI Media Converter Installation Guide

VL BPC MINI. A configurable industrial computer platform. Data sheet 2930_en_F. 1 Description. 2 Features

INSTALLATION INSTRUCTIONS Product Revision Form GETAC K120 TABLET DOCKING STATION

Havis Integrated Control System Installation Instructions for Standard* Ford Police Interceptor Utility

Installation and Maintenance

Installing and Upgrading Internal Modules and FRUs

Installation Guide. Retrofit Kit for USB Ready Intraoral Systems

Rack Installation Instructions

IBM. Rack Installation Instructions

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

SYSTIMAX 360 ipatch Network Manager Module Faceplate Instructions

Nvidia Quadro FX 5600 graphics card and auxiliary power adapter cable installation

Chapter 4 Replacement Procedures

Dell SC7020 Storage Controller Getting Started Guide

Alienware Area-51 R5 Service Manual

Installing and Managing the Switch

Print Mechanism Maintenance Kit

RPC-600/610. Industrial Chassis USER' Manual

ULTRATRAK RM4000 QUICK START GUIDE. Version 1.3

INSTALLATION INSTRUCTIONS

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

Z-Truck (Vertical Moving) Z-truck Flag. Y-Truck (Horizontal Moving) FIGURE 1: VIEW OF THE Z-TRUCK. Flexshaft Assembly

ClearCube F6151 Media Converter Chassis System with 10/100BaseTX to 100BaseFX Converter

Basketball Shot Clock Set LX2180 Manual

Installing System Board Options

EN-1000 Quick Configuration Guide

Transcription:

EN-4000 Reference Manual Document 3 Connecting the EN-4000 to DC Power T his document describes assembly and use of a DC power connector for Encore Networks, Inc. s EN-4000 chassis. The detailed steps also include connection to AC power. Note: If you do not need or want a detailed description of this procedure, see EN-4000 Quick Connection to DC Power.! Caution: If you have an EN-4000 chassis that can use both DC and AC power, it is important to follow these steps to connect the chassis to its power sources in the proper order. If you received a chassis that uses DC input power, the package includes a standard DC power connection set (Figure 3-1, Figure 3-2, and Figure 3-3). Figure 3-1. Top Section of Connector Shell Figure 3-2. DC Power Connector For information on trademarks, safety, limitations of liability, and similar topics, see http://www.encorenetworks.com/disclaimer.htm. Version A, July 2014 2014 Encore Networks, Inc. All rights reserved.

Page 3-2 EN-4000 Reference Manual, Document 3 Figure 3-3. Bottom Section of Connector Shell To connect your EN-4000 to a DC power source, perform the following procedure. Use the steps to connect cables to user equipment and to prepare the chassis for configuration and use. Note: Consult the EN-4000 Hardware Description and Specifications to see diagrams of the chassis and the ports. 1 Place the EN-4000 chassis at its physical location in the network for example, on a shelf or tabletop. Note: Do not place anything below or on top of the chassis; it must have proper ventilation for cooling. 2 Connect the EN-4000 chassis s ports to their network devices. For example, connect the LAN ports, WAN port, USB port, and expansion ports (serial port, etc.) to the network devices, as follows: a Use an Ethernet 10-Base-T cable to connect the WAN port to the WAN equipment. b Use an Ethernet 10-Base-T cable to connect each LAN port to its equipment. c Connect additional network equipment to the remaining ports on the EN-4000 chassis. This includes any port in the expansion slot. 3 Use an Ethernet cable to connect your management console (for example, a PC) to a LAN port (eth 1) on the back of the EN-4000. 4 If the EN-4000 chassis will use only AC input power, go to step 10. 5 If the EN-4000 chassis will use DC input power, follow step 6 through step 9 to prepare the chassis for its DC power connection. Note: The DC power source must supply -12/-24 VDC or -24/-48 VDC. 6 Make sure the EN-4000 chassis is disconnected from all power sources. 7 Do the following: a Turn the DC power connector (the DC power plug) on its side, with the screwheads at the left and with the prongs pointing away from you (as shown in Figure 3-4). Figure 3-4. DC Power Connector, on Side

Connecting the EN-4000 to DC Power Page 3-3 b Note the following: The top post is + (for the positive wire). The bottom post is (for the negative/return wire). c Connect a minimum 14 AWG two-wire input cable to the green two-pin power connector (that is, the power plug). Make sure you connect the correct wire to each positive or negative post. Figure 3-5 shows the plug with the cables attached. Figure 3-5. DC Power Connector with Wires 8 A shell cover is provided with the DC power connector, to provide strain relief for the wires. Restrain the wires against the lower half of the shell, and place the shell around the connector, as described in the following substeps: a Seat the DC power connector (the plug) into the bottom half of the shell. The connector will seat into the shell in only one way, as shown in Figure 3-6. Figure 3-6. Cabled DC Power Connector and Bottom Section of Shell Note: The top and bottom sections of the shell differ. The top section (recall Figure 3-1) has flanges to fit against the bottom section s latches (recall Figure 3-3).

Page 3-4 EN-4000 Reference Manual, Document 3 b Insert the end of a cable-tie through one of the holes in the bottom of the connector shell (Figure 3-7). Note: The cable lock (the hollow block) can be above the lower shell (as shown) or below the lower shell. Figure 3-7. Cable-Tie through Bottom of DC Power Connector Shell! c Pull the cable-tie across the cables and through the other hole in the shell bottom. d Put the end of the cable-tie through its lock and pull the cable-tie snug around the cables. Note: The lock is designed so that the cable may move in only one direction. If you need to remove the cable, you will have to cut the cable. e If you wish, you may trim the end of the cable-tie to be flush with the lock. Caution: If you trim the cable-tie, trim it flush with the lock. Do not leave a few millimeters of the cable-tie extending past the lock. It is better to leave the cable-tie untrimmed than to cut it non-flush. f With the plug seated into the bottom section, place the top section of the shell onto the bottom section. Do not yet snap them into place. Figure 3-8 shows how the top and bottom sections fit together around the DC power plug. Figure 3-8. Top Section of Shell above Cabled DC Power Connector in Bottom Section of Shell g Make sure the DC power connector sits properly in the bottom section. Then snap the top and bottom sections together, as shown in Figure 3-9.

Connecting the EN-4000 to DC Power Page 3-5 Note: Make sure the cables do not get caught between edges of the shell. The cables should fit through the cable hole without catching on an edge. Figure 3-9. Closed Shell Assembly h If you need to take the case apart, grasp each flange of the top section and gently pull them away from the latches on the bottom section. Then pull the top section off the bottom section. Repeat step 8a through step 8g to reassemble the connector case. Note: Figure 3-10 shows the standard orientation of the EN-4000 s DC power input port. Figure 3-10. EN-4000 DC Power Input Port Flanges on the plug (Figure 3-11) allow it to fit into the DC power input port on the backplate of the EN-4000 chassis in only one way. You may need to turn the plug over to fit it into the port. Figure 3-11. DC Shell Assembly Connector Flanges 9 Do the following: a If necessary, rotate the plug s shell assembly 180 around the axis corresponding to the DC power cable (Figure 3-12 and Figure 3-13).

Page 3-6 EN-4000 Reference Manual, Document 3 Figure 3-12. Rotate DC Shell Assembly 180 Degrees around Axis of Power Cable Top of Shell Assembly Figure 3-13. DC Shell Assembly Rotated 180 Degrees Bottom of Shell Assembly! b Plug the DC power connector into the DC power input port on the rear of the EN-4000 chassis. c Then connect the other end of the DC power cable to a -12/-24 volt DC power source or a -24/-48 volt DC power source. Note: The power source must supply -12/-24 VDC or -24/-48 VDC. Caution: The DC power source must match the DC input power rating indicated on the EN-4000 chassis. The EN-4000 chassis powers up. 10 If the EN-4000 chassis will use AC input power (in addition to DC power or instead of DC power), connect the AC power supply to the chassis, and then connect the AC power supply to a power outlet supplying 100 240 VAC at 47 63 Hz. If the chassis is already connected to DC power, the chassis has already powered up. If the chassis uses only AC power, the chassis powers up now. The EN-4000 chassis s hardware installation is complete. The Next Step Follow the procedures in Configuring General Settings for the EN-4000 to prepare the EN-4000 for its role in the network.