Binary output 520BOD01 Connections and settings

Similar documents
Analog input 520AID01 Connections and settings

I/O adapter 520ADD03 Connections and settings

Binary output and supervision 520CSD01 Data sheet

Analog output 520AOD01 Data sheet

ABB 520BID01 Binary Input datasheet

DIN Rail RTU 540CMD01 Data sheet

Switch 560NMS34 Data sheet

RTU560 Connections and Settings DIN Rail RTU 560CIG10

Switch 560NMD01 Data sheet

Bus Connection Unit 560BCU04

RTU511. Binary Output 23BO62. Characteristics. Application. Data Sheet Binary Output 23BO62. The binary output is made via relay contacts.

RTU560 Remote Terminal Unit Connections and Settings

Switch 560NMD11 Data sheet

EX-RC1 Remote I/O Adapter

Application. Characteristics RTU540. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Characteristics. Application RTU560. DIN Rail RTU 560CIG10. Data Sheet DIN Rail RTU 560CIG10

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Redundancy unit CP-A RU

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

Operating instructions. Switching amplifier DN0210 DN / / 2015

Redundancy unit CP-D RU Accessory for CP range power supplies (e.g. switch mode power supplies CP-D range)

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

UniStream Uni-I/O Modules

F²MC-8L FAMILY MB89201 SERIES FLASH PROGRAMMING 8-BIT MICROCONTROLLER APPLICATION NOTE. Fujitsu Microelectronics Europe Application Note

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Application. Characteristics RTU560. Data Sheet Communication Unit 560CMD11. Communication Unit 560CMD11

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

High Speed Remote I/O Module

User Manual Gateway component for EtherNet/IP

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

UniStream Uni-I/O Modules

DCM Digital Control Modules

Operating instructions. Speed monitor D / / 2014

Install Motor Controller User Manual

Application Guide. M 2174B Moloney Replacement Adapter Panel

Vision OPLC V TR6/V350-J-TR6

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

F2MC MB90385 series Evaluation Board Documentation. Revision Date Comment V New document

End User License Agreement

RTU500 series. RTU500 series Remote Terminal Unit Function Description Release 12 Part 5: SCADA functions

P O W E R S U P P L Y M A N U A L

22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs

This guide provides basic information for Unitronics controller model V T2.

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

GV150 / GV151 Impulse amplifier and splitter for incremental encoder signals

RTU500 series Data Sheet Power Supply CP-E 24/2.5

This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Draft sensor KMB series 30

Application. Characteristics RTU560. DIN Rail RTU 560CIG10. Data Sheet DIN Rail RTU 560CIG10

CPCI-PS24 24V-Power Supply

Channel Switch CS. General Operating, Maintenance and Installation Manual

Tina 1A Blanking plug

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety

Conductive Level Controller

Vision OPLC. V T38 Installation Guide. General Description

The identified danger could cause physical and property damage.

PCS 7 Configuration Changes in RUN with Active Fieldbus Diagnosis

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

V E1B Snap-in I/O Module

Micro-OPLC Installation Guide

Sigbert Reimann, Remote Control Forum, Datum 9. October 2013 RTU - Review and News. ABB Network Management Forum December 10, 2013 Slide 1

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Product and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)

XBDM. 1015LV, 1020LV, 1030LV, 1020HV Models USER & INSTALLATION MANUAL BYPASS DISTRIBUTION MODULE

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

OPLC Installation Guide

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

F²MC-8FX FAMILY MB95100 SERIES EMULATOR HW SETUP 8-BIT MICROCONTROLLER APPLICATION NOTE. Fujitsu Microelectronics Europe Application Note

Operating Manual -ENGLISH- Page 1 KWG-ISO

Solid State Relays with Failure Detection Function

UM NVT2001GM and NVT2002DP demo boards. Document information

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

UM NVT2008PW and NVT2010PW demo boards. Document information

CPU369-Module Documentation. Fujitsu Microelectronics Europe GmbH Am Siebenstein Dreieich-Buchschlag, Germany

CU port USB 2.0 hub. Version: 1.1 Date:

Keysight E5864A Removable Hard Drive for Series Logic Analyzers. Installation Guide

Position sensor PO1 series 20

BODAS DCT Display Configuration Tool

CAN Repeater CAN-CR200, CAN-CR220, CAN-CR210/FO USER MANUAL ENGLISH

V E2B Snap-in I/O Module

PMDX-105. I/O Option Riser Board User s Manual. Document Revision: 1.1 Date: 7 September 2004 PCB Revision: PCB-443A

Technical Manual Room temperature controller

Single Cell Battery Power Solution

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

General Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34

Digital ac/dc (24V) Input Module

PTZ Control VMC Joystick

MINI MCR-SL-UI-REL(-SP)

Characteristics. Application RTU560. HMI unit 560HMR01. Data Sheet HMI unit 560HMR01

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

UniStream Uni-I/O Modules

Zener Barriers Bulletin 937Z

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Logitech Alert 700i/750i System Requirements & Support Guide

Transcription:

RTU520 product line Binary output 520BOD01 Connections and settings Application, characteristics and technical data have to be taken from the hardware data sheet: 520BOD01 Data sheet 1KGT 150 864 Operation The binary output module 520BOD01 can be used for the control of 8 binary process signals using relay contacts. The allocation of an output signal to the processing functions can be done according to the rules of configuration. Processing functions The module 520BOD01 is able to process the following types of signals: Single or double commands (SCO or DCO) with 1 or 2 pole output without (1 out of n) check Single or double commands (SCO or DCO) with 1.5 or 2 pole output with (1 out of n) check Regulation step command (RCO), 1 or 2 pole Digital setpoints commands, 8 Bit without strobe (DSO8) Bitstring output, 1 or 8 Bit (BSO1 or BSO8) The microcontroller on the module processes all time critical tasks of the parameterized processing functions. Moreover it carries out the interactive communication with the RTU I/O bus. All configuration data and processing parameters are loaded by the communication unit via the RTU I/O bus. In connection with an I/O adapter (e. g. 520ADD01) or the RTU520 communication unit the module is interfaced to the RTU520 I/O bus. The binary output unit can execute the following processing functions on the individual signal types: Control of the command output duration Command monitoring functions: monitoring of the output bit patterns by reading back the output state switching voltage monitoring ( coil voltage) before and during output only together with (1 out of n) control module command output duration monitoring During initialization and operation the module carries out a number of tests. If a fault occurs it is reported to the communication unit. All fault conditions impairing the function of the module are displayed as common fault signal by a red LED. A failure of the module is detected by the communication unit. Parameter name Default Parameter location value range: 0.1... 25.5 sec Command pulse length 1 sec SCO, DCO, RCO PDP parameters For additional information on these configuration parameters in RTUtil500 refer to RTU500 series function description part 5: SCADA functions (1KGT 150 797). Settings The device has no switches or jumpers. Signaling LED BO1... BO8 The 520BOD01 has 8 yellow LED s on the front plate indicating the state of the outputs. The LEDs are ON for the time an output is active (pulse or persistent). LED ERR The module monitors and checks the own functionality as well as the dialog via the I/O bus. Detected errors are indicated by the red LED ERR on the front plate and transmitted via the I/O bus to the communication unit (CMU). Additional diagnostic messages are available using the WebServer on the CMU. The LED ERR indicates module errors or I/O bus errors: module runs initialization procedure module is performing a cold or warm start module has detected a memory error (RAM or Flash) microcontroller is faulty no dialog via the I/O bus for at least 2 minutes. The module is not polled by the CMU.

Connections I/O bus connection The module is connected to the RTU I/O bus via the connectors X1 and X2. For a 2 pole connection two relays (e.g. for double commands and R03, R02 and R04) of the binary output board 520BOD01 are used (see Fig. 8 and Fig. 9). For the (1 out of n) check along with 560CIG10/560CID11 the connection is shown in Fig. 10. ADVICE To prevent damage on the connected modules deenergize the system before plugging or unplugging the I/O bus connectors. ADVICE To prevent unintended disconnection of the I/O bus connectors end stops (e. g. BAM3 1SNK900001R0000) shall be used at both ends of the I/O assembly. Power supply The electronic circuits on the process side are supplied by an external voltage input. The voltage input is connected at X3. ADVICE For the operation of the module addition () is required (e. g. from 560PSU40/41). This voltage has to be supplied from external and wired to the connector Process connection The process will be connected to the screw terminals X4 (see Fig. 2). The 1 pole connection is described in Fig. 7. WARNING EMC disturbances especialy mainsborne disturbances may cause temporary or permanent failures of the module. To enshure the RTU500 series EMC capabilities all process cables must be shielded and shall be grounded at a largearea when entering the cabinet. Safety instructions Dangerous process voltages Hazardous voltage. DANGER Contact with live circuits will cause electric shock or burn. Verify that all terminals feeding dangerous contact voltages (supply voltage, input or output channels) is in secure OFF state before connecting or withdrawing the terminals. Environmental conditions WARNING Environmental conditions with high humidity and condensing water may cause temporary or permanent failures of the module. For environmental conditions with condensing water a heating unit has to be installed inside the cabinet. 2 1KGT 150 865 V002 1 Binary output 520BOD01

Figure 1: 520BOD01 front plate Figure 2: 520BOD01 label 1 6 5 2 4 3 Figure 3: RTU520 DIN rail mounting step 1 1 Insert upper edge into DIN rail and push downwards 2 Push lower edge towards DIN rail and snap in the module Figure 4: RTU520 DIN rail mounting step 2 3 + 4: Shift one module connector into the other starting from right to left Figure 5: RTU520 DIN rail mounting step 3 5 + 6: Mount end stops at the left and right side Binary output 520BOD01 1KGT 150 865 V002 1 3

C01 O01 X41 X42 R02 C02 O02 X43 X44 RTU I/O bus Microcontroller RAM Flash ERR Output register Output state monitoring R03 R04 R05 C03 O03 C04 O04 C05 O05 X45 X46 X47 X48 X49 X410 IOC R06 C06 O06 X411 X412 R07 C07 O07 X413 X414 R08 C08 O08 X415 X416 Voltage monitoring + X31 X32 Figure 6: 520BOD01 connection diagram 4 1KGT 150 865 V002 1 Binary output 520BOD01

520BOD01... R08 X41 X42 X415 X416 X31 X32 + C1... C8 U P 1 pole connection Figure 7: 1 pole process connection, single command 520BOD01 R02 X41 X42 X43 X44 X31 X32 + C1 U P Single command 2 pole connection Figure 8: 2 pole process connection, single command Binary output 520BOD01 1KGT 150 865 V002 1 5

520BOD01 R02 R03 R04 X41 X42 X43 X44 X45 X46 X47 X48 X31 X32 + U P ON OFF Double command 2 pole connection Figure 9: 2 pole process connection, double command 520BOD01 560CIG10 / 560CID11... R08 (1 out of n) check circuit X41 X42 X415 X416 X31 X32 + X1 2 3 coil voltage (1 out of n) X14 X1 4 X15 5 6 7 + + C1... C8 + U P C9 C10 Figure 10: (1 out of n) check, 1.5 pole connection, single command 6 1KGT 150 865 V002 1 Binary output 520BOD01

ABB AG Power Systems Division P.O. Box 10 03 51 68128 Mannheim, Germany www.abb.com/remoteterminalunits Note: The specifications, data, design or other information contained in this document (the Brochure ) together: the Information shall only be for information purposes and shall in no respect be binding. The Brochure does not claim to be exhaustive. Technical data in the Information are only approximate figures. We reserve the right at any time to make technical changes or modify the contents of this document without prior notice. The user shall be solely responsible for the use of any application example or information described within this document. The described examples and solutions are examples only and do not represent any comprehensive or complete solution. The user shall determine at its sole discretion, or as the case may be, customize, program or add value to the ABB products including software by creating solutions for the end customer and to assess whether and to what extent the products are suitable and need to be adjusted or customized. This product is designed to be connected to and to communicate information and data via a network interface. It is the users sole responsibility to provide and continuously ensure a secure connection between the product and users or end customers network or any other network (as the case may be). The user shall establish and maintain any appropriate measures (such as but not limited to the installation of firewalls, application of authentication measures, encryption of data, installation of antivirus programs, etc) to protect the product, the network, its system and the interface against any kind of security breaches, unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB AG is not liable for any damages and/or losses related to such security breaches, any unauthorized access, interference, intrusion, leakage and/or theft of data or information. ABB AG shall be under no warranty whatsoever whether express or implied and assumes no responsibility for the information contained in this document or for any errors that may appear in this document. ABB AG's liability under or in connection with this Brochure or the files included within the Brochure, irrespective of the legal ground towards any person or entity, to which the Brochure has been made available, in view of any damages including costs or losses shall be excluded. In particular ABB AG shall in no event be liable for any indirect, consequential or special damages, such as but not limited to loss of profit, loss of production, loss of revenue, loss of data, loss of use, loss of earnings, cost of capital or cost connected with an interruption of business or operation, third party claims. The exclusion of liability shall not apply in the case of intention or gross negligence. The present declaration shall be governed by and construed in accordance with the laws of Switzerland under exclusion of its conflict of laws rules and of the Vienna Convention on the International Sale of Goods (CISG). ABB AG reserves all rights in particular copyrights and other intellectual property rights. Any reproduction, disclosure to third parties or utilization of its contents in whole or in part is not permitted without the prior written consent of ABB AG. Copyright ABB 2015 All rights reserved Binary output 520BOD01 1KGT 150 865 V002 1 7