Digital Indicating Controllers. JC Series. High performance controllers...at the lowest prices anywhere! Toll Free

Similar documents
PXR Series Advanced Self-Tuning Temperature and Process Controllers

DIGITAL INDICATING CONTROLLER

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

- SELF-TUNING PID ALGORITHM - INTUITIVE COLOR DISPLAY WITH TEXT MESSAGING - UNIVERSAL PROCESS AND TC/RTD INPUTS - MULTI- FUNCTION RAMP- DWELL/PROCESS

SX90 Process Controller

FY Series Digital PID Controller Operation Manual FY400 FY700 FY800 FY900 FY600

MODCELL 2050R Single Loop Controllers

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

UDC1200 and UDC1700 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

MLC 9000 Bus Compatible PID

12-36 VDC/12-24 VAC Power Option 4-Digit Display, 0.56 (14.2 mm) or 1.20 (30.5 mm)

MRC 7000 Proven Recording Reliability that Became the Industry Standard!

The CAL range of temperature controllers

Trident and Trident X2 Digital Process and Temperature Panel Meter

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

Digital Controller-Version II ES100X/P. Ordering Information. Intelligent Digital Controller and Programmer

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

ProVU 4 Advanced Temperature & Process Controller

Universal power supply

Process displays For current and voltage

Temperature, Process &

/8 DIN Motorized Valve Controller

EZ-ZONE. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

Temperature Controller E5C4

Measuring and Monitoring Relays

C160 Wall-/Pipe Mounted Universal Process Indicator

/8 DIN Universal Process Indicator

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

PD765 TRIDENT. Trident Series Process & Temperature Meters.

Temperature/Process Controllers Manual

LAUREL ELECTRONICS, INC.

PD765 TRIDENT. Trident Series Process & Temperature Meters.

OLS VT10 SERIES STANDARD DUAL DISPLAY PID AUTOTUNE RAMP-TO-SETPOINT ULC, UL, CE (4810) AUTO / MANUAL 15 SECURITY OPTIONS UNIVERSAL INPUT

UDC1200 & UDC1700 Universal Digital Controllers Series Micro-Pro Specifications

SINGLE-CHANNEL PROCESS INDICATOR series 8001

Level instruments. Communications and Displays SITRANS RD200. 5/306 Siemens FI Technical specifications. Overview

TRACKER 220 SERIES. Digital Panel Indicators. A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

The Tracker 220 Series A Complete Range of Universal Input Digital Panel Indicators for Temperature and Process Measurement

Wall-/Pipe Mounted Universal Process Indicator

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

P/N /02 Rev. C ECO # Model 1440 Microprocessor-based Temperature Controller Installation and Operation Manual

JUMO Quantum PID100/PID200/PID300

ATR121 Controller with Dual Setpoint

TECHNICAL DATA SHEET. ProVU 4 Advanced Temperature Controller. Features. Description

Single Loop Controller Models R35, R36

Controller module. Brief description. Features. Block structure. Data Sheet Page 1/7

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

NX-series Temperature Control Unit NX-TC

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

Universal Process Controller

Chapter. Modbus. In This Chapter...

EZ-ZONE ST. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy SPECIFICATION SHEET

E5_C TEMPERATURE CONTROLLER

BACnet Controller for General-purpose Building Applications

Indicators. Product Mounting Display Height Page

Neon pr. ph/ ORP measurement. Applications. Description

E5CC/E5EC TEMPERATURE CONTROLLER

Model Number Structure

Single Loop Controller SDC15

Description Model Specification Base Unit E5AK-AA2 AC Standard model

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

West Instruments. The 8800 series. Process Controllers and Profilers series. ...setting a new standard in advanced control

Simplified information where and how you want it.

H3 Series. Nanmac Corporation. Dual-Line 6-Digit Temperature Meter.

Digital Indicator Solutions

Basic Temperature and Limit Controllers

Integrated Multi-Function

Temperature, Process &

Basic Temperature and Limit Controllers. Provide Economical Solution for a Wide Range of Applications SPECIFICATION SHEET

UNIVERSAL TEMPERATURE TRANSMITTER

100mm Process Indicator Recorder

Control IT. /16 DIN Controller/Alarm Unit. Data Sheet SS/C50_7 C50. C50 the 1 /16 DIN controller to suit your simplest applications

SEM310 SEM310X HART UNIVERSAL TEMPERATURE TRANSMITTER

EZ-ZONE ST. EZ-ZONE ST Integrated Control Loop Makes Solving the Thermal Requirements of Your System Easy

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

HIGH-VOLTAGE DC METER

JCS, JCM, JCR, JCD-33A (C5)

J itron DR 100 Microprocessor Controller

Series Temperature Controller Instruction Sheet

Drawings. Model UT35A Digital Indicating Controller (UT35A-NNN-xx-xx/x) SD 05P01D41-05EN. External Dimensions. Panel Cutout Dimensions.

Paperless Recorder VGR-B100. Series

High Voltage DC Meter

Contact protection relay

E5_C TEMPERATURE CONTROLLER

NO: PH-185 PRODUCT: E3JK Photoelectric Sensors DATE: May 2014 TYPE: Discontinuation Notice

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

PRODUCT FAMILY: SOLO Controllers Number: AN-LC-009

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

Masibus Automation And Instrumentation Pvt. Ltd.

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Yokogawa Advanced Controllers

Tempco Instruction Manual

PD7000. PROVU Dual-Line 6-Digit Temperature Meter SERIES.

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

SSR - Supplies - Relays

MIC-2 MKII, Multi-instrument DATA SHEET

Transcription:

Digital Indicating Controllers JC Series High performance controllers...at the lowest prices anywhere! www.mod-tronic.com Toll Free 1-800 794-5883

Standard Features Structure Units available in standard DIN sizes (1/16, 1/8 and 1/4 DIN). NEMA 4X protective construction. Black enclosure. Programmable Alarms Units feature standard single alarm output with optional second alarm. True Multi-Input Units feature true multi-input capabilities: 10 thermocouple types, 1 RTD type, 2 current inputs, and 4 voltage inputs. Auto/Manual Control Manual overide allows you to take control of your process at anytime. Model JCS 1/16 DIN (48mm x 48mm) Large LED Display All units feature dual display. PV red 4 digits, SV green 4 digits. PID Autotune All units feature as standard full function third generation PID Autotune. This feature minimizes process overshoot under the most demanding applications. Modbus Protocol With RS485 (Option) Units offer communications capabilities. Safety Approvals UL, cul and CE Safety Approvals. Warranty All units manufactured to strict ISO standards and offer full 3 year manufacturers warranty. Low Cost Most advanced price/performance package available. Model JCR 1/8 DIN (48mm x 96mm) Input Range Table Thermocouple RTD Input Type K J R S B E T N PL-II C (W/Re5-26) Pt100-200 to 1370ºC -199.9 to 400.0ºC -200 to 1000ºC 0 to 1760ºC 0 to 1760ºC 0 to 1820ºC -200 to 800ºC -199.9 to 400.0ºC -200 to 1300ºC 0 to 1390ºC 0 to 2315ºC -199.9 to 850.0ºC -200 to 850ºC Scale -320 to 2500ºF -199.9 to 750.0ºF -320 to 1800ºF 0 to 3200ºF 0 to 3200ºF 0 to 3300ºF -320 to 1500ºF -199.9 to 750.0ºF -320 to 2300ºF 0 to 2500ºF 0 to 4200ºF -199.9 to 999.9ºF -300 to 1050ºF Model JCD 1/4 DIN (96mm x 96mm) DC 4 to 20mA DC 0 to 20mA DC 0 to 1V DC 0 to 10V DC 1 to 5V DC 0 to 5V DC -1999.9 to 9999, -199.9 to 999.9-19.99 to 99.99, -1.999 to 9.999 For DC current input a shunt resistor (50Ω) is provided as standard.

General Specifications Display Input Accuracy (Setting Indicating) Input Sampling Period Control Output (OUT 1) Control Action Alarm 1 (A1) Mounting Method Setting Method Material Color Supply Voltage Environment External Dimension & Weight JCS-33A: PV [Red 4 digits, Character size: 10.2 x 4.9mm], SV [Green 4 digits, Character size 8.8 x 4.9mm] JCR-33A: PV [Red 4 digits, Character size: 11.2 x 5.4mm], SV [Green 4 digits, Character size 11.2 x 5.4mm] JCD-33A: PV [Red 4 digits, Character size: 18 x 8mm], SV [Green 4 digits, Character size 12.6 x 6.6mm] Thermocouple ----- K, J, R, S, B, E, T, T, N, PL-II C (W/Re5-26) External resistance: 100Ω or less (However, for B input: 40Ω or less) RTD ------------------ Pt100, 3-wire system (Allowable input wire resistance per wire: 10Ω or less) DC current ---------- 0 to 20mA DC, 4 to 20mA DC Input impedance: 50Ω (Connect shunt resistor 50Ω between input terminals.) Allowable input current: 50mA or less (When shunt resistor 50Ω is used.) DC voltage ---------- 0 to 1V DC Input impedance: 1MΩ or greater Allowable input voltage: 5V or less Allowable signal source resistance: 2kΩ or less 0 to 5V DC, 1 to 5V DC, 0 to 10V DC Input impedance: 100kΩ or greater Allowable input voltage: 15V or less Allowable signal source resistance: 100Ω or less Thermocouple -------------------- Within ±0.2% of each input span ±1 digit or ±2ºC (4ºF) whichever is greater However, R or S input 0 to 200ºC (0 to 400ºF): Within ±6ºC (12ºF) B input 0 to 300ºC (0 to 600ºF): Accuracy is not guaranteed. K, J, E and N input less than 0ºC (32ºF): Within ±0.4% of input span ±1 digit RTD --------------------------------- Within ±0.1% of each input span ±1 digit or ±1ºC (2ºF) whichever is greater DC current and DC voltage ---- Within ±0.2% of each input span ± 1 digit 0.25 seconds Relay contact - (JCS-33A) 3A 250V AC (Resistive load), 1A 250V AC (Inductive load cos =0.4), Electric life: 100,000 times Non-contact DC voltage ----12-14V DC Max. 40 ma (short-circuit protected) DC current ----- 4 to 20mA DC Load resistance: Max. 550Ω Actions mentioned below can be selected by key operation. (Factory default set as PID) PID (with auto-tuning function), PI, PD (with manual Reset function), P (with manual reset function), ON/OFF OUT 1 proportional band (P) --- Thermocouple: 0 to 1000ºC (0 to 2000ºF) (ON/OFF action when set to 0) RTD: 0.0 to 999.9ºC (0 to 999.9ºF) (ON/OFF action when set to 0.0) DC current and DC voltage: 0.0 to 100.0% (ON/OFF action when set to 0.0) Integral time (I) -------------------- 0 to 1000 seconds (OFF when set to 0) Derivative time (D) ---------------- 0 to 300 seconds (OFF when set to 0) Proportional cycle ----------------- 1 to 120 seconds (DC current output type is not available.) OUT1 ARW ------------------------- 0 to 100% FS Hysteresis ------------------------- Thermocouple and RTD: 0.1 to 100.0ºC (F) DC current and DC voltage: 1 to 1000 (Decimal point place follows the selection) OUT1 Output limit ------------------- -5 to 100% Alarm action and Energized/De-energized can be selected by key operation. Setting accuracy Action Hysteresis Output 100 to 240V AC 50/60Hz, 24V AC/DC 50/60Hz Allowable voltage fluctuation: 85 to 264V AC, 20 to 28 AC/DC, Power consumption approximately 8VA Ambient temperature: -10 to 50ºC Ambient humidity: 35 to 85%RH (No condensation) JCS-33A: 48 x 48 x 96.5mm (W x H x D) Approx. 200g JCR-33A: 48 x 96 x 98.5mm (W x H x D) Approx. 250g JCD-33A: 96 x 96 x 98.5mm (W x H x D) Approx. 370g The same as the indicating accuracy. ON/OFF action Thermocouple and RTD: 0.1 to 100.0ºC (ºF) DC current and DC voltage: 1 to 1000 (The placement of the decimal point follows the selection) Relay contact 3A 250V AC (Resistive load), Electric life: 100,000 times JCS provided with one piece mounting bracket. JCR and JCD includes screw type mounting brackets. Sheet key input. Material: Flame resistant resin. Color: Black

Options Alarm 2 [A2] Heater Break Alarm [W] Control Output (OUT2) (Heating/Cooling Control) [DR,DS,DA,DT] Serial Communication [C5] SV1/SV2 External Selection [SM] Loop Break Alarm [LA] Transmitter Power Supply [P24] When this option is added, 1 alarm point is added. Alarm action type, Setting range and Relay contact type are the same as those of Alarm 1 (A1). See Alarm 1 (A1) section. Watches the heater current with CT (current transformer), and detects burnout. Heater rated current must be selected from 5A, 10A, 20A and 50A. Setting accuracy---within ±5% of heater rated current Output---------------Relay contact 3A 250V AC (Resistive load), Electric life: 100,000 times Self-holding---------Not available Accessories--------CT (Current Transformer) If this option is applied, control output 2 is added and enables Heating/Cooling control. There are 4 types of control output i.e. Relay contact output (DR), Non-contact voltage output (DS), DC current output (DA) and Non-contact relay output. Must be designated when ordering. (Relay contact output, Non-contact voltage output and DC current output can be applied to JCR-33A and JCD-33A series.) (Only Non-contact relay output can be applied to JCS-33A series.) Control action (Heating side): The same as control output (OUT1) Control action (Cooling side): Proportional band (P)-- Integral time (I)---------- Derivative time (D)----- Overlap cycle----------- Dead band--------------- Hysteresis---------------- Control output Relay contact (DR) Non-contact voltage (DS) DC current (DA) Non-contact relay (DT) 0.0 to 10.0 times of the control output (OUT1) proportional band (ON/OFF action when set to 0.0) The same as the integral time setting value of the control output (OUT1) The same as the derivative time setting value of the control output (OUT1) Thermocouple and RTD: -100.0 to 100.0ºC (F) DC current and DC voltage: -1000 to 1000 (Decimal point place follows this selection.) 0.1 to 100.0ºC (F) : 3A 250V AC (Resistive load), 1A 250V AC (Inductive load cos =0.4), Electric life: 100,000 times : 12-14V DC Max. 40mA (short-circuit protected) : 4 to 20mA DC Load resistance: Max. 550Ω : 3A 250V AC (Resistive load) Only available on model JCS Cooling action mode (This must be selected from below by key operation.) Air cooling (Linear characteristic) Oil cooling (1.5 th Power of characteristic) Water cooling (2 nd Power of characteristic) Various setting status changing, reading and setting of the JC -33A can be performed from external computer. By combining programmable controller (Option: SVTC added) with JC -33A (Option: C5 added), it is possible to transmit the SV (setting value) of the programmable controller digitally to the JC -33A. Communication interface------------based on EIA, RS-485 Data transfer rate--------------------(2400/4800/9600/1920bps) Selectable by key operation Communication protocol--------------based on Shinko standard protocol or Modbus (Selectable by key operation) (When Modbus is selected, RTU mode or ASCII mode can be selected.) Number of connectable units-------a maximum of 31 units per host computer Provided as standard feature on model JCR and JCD. Option only on model JCS. Main setting value 1 and 2 can be changed by external contact. Terminal between 13 and 14 is open: SV1, Terminal between 13 and 14 is closed: SV2 This option enables Heater burnout, Sensor burnout and Input burnout to be detected. Loop break alarm time----------------0 to 200 minutes Loop break alarm span---------------thermocouple and RTD: 0 to 150ºC (F), 0.0 to 150.0ºC (F) DC current and DC voltage: 0 to 1500 Output---------Relay contact 3A 250V AC (resistive load), 1A 250V AC (Inductive load cos =0.4), Electric life: 100,000 times When this option is added, 24V DC is output from the terminal 9 to 10 of JCD-33A and JCR-33A Output voltage: 24V DC ±3V (When load current is 30mA) Ripple voltage: 200mV (When load current is 30mA) Maximum load current: 30mA All units feature a full 3 year warranty and lifetime technical support!

External Dimensions Panel Cutout JCS-33A Series Lateral close mounting n: Number of units mounted JCR-33A Series Lateral close mounting n: Number of units mounted JCD-33A Series Lateral close mounting n: Number of units mounted Terminal Wiring JCR-33A, JCD-33A series JCS-33A series Shinko is an ISO 9001 facility

Model Number Configuration JC -33A- /M FRONT PANEL SIZE 1/16 DIN (48mm x 48mm) S 1/8 DIN (48mm x 96mm) R 1/4 DIIN (96mm x 96mm) D ALARM FUNCTION Standard CONTROL OUTPUT Relay Contact R SSR Driver S 4-20mA* A *Not available with heater break alarm. INPUT True Multi-Input T/C, RTD, Voltage, Current A M SUPPLY VOLTAGE 24V AC/DC 1 100-240V AC - CONTROL OUTPUT 2 Relay Contact SSR Driver 4-20mA Solid State Relay Output* *Only available on the JCS model. OPTIONS Alarm 2 RS-485*** Heater Break (5A) (10A) (20A) (50A) Remote SV** Loop Break Alarm Transmitter Power Supply 24 V DC* *Not available on the JCS. ** Standard feature on the JCR and JCD *** Not available with SM option. DR DS DA DT A2 C5 W5A W10A W20A W50A SM LA P24 High Performance Temperature & Recording Instrumentation...at the lowest prices anywhere! Shinko is an ISO 9001 facility JC -SNA.-06.2002-A