Bulletin 1790D, 1791D, 1732 Product Line Overview 6 / 2011 Bulletin 1790D 1732 Type CompactBlock LDX ArmorBlock I/O Features I/O Analog Inputs/ Outputs Software Wide breadth of I/O types that can handle diverse applications Expandable up to 3 digital expansion blocks (80 I/O's) Universal sink/source inputs reduces the number of components to stock and allows flexibility of input types Selectable termination types (D-shell or screw) Easy to connect and configure using modular EDS files ODVA conformance ensures high level of interoperability with other DeviceNet products Analog DeviceNet bases for current, voltage, PT100 and thermocouple execution CompactBlock LDX I/O are also available for other network 24V DC, 120V AC and relay discrete blocks with built-in DeviceNet adapter Cyclic and change-of-state messaging increases network throughput, increases productivity Auto baud rate detection Up to 80 I/O with discrete bases and up to 36 I/O with analog bases 4 & 2 (Voltage/Current/RTD/ Thermocouple) RSNetworx for DeviceNet Sealed housing rated for IP67K and NEMA 4X eliminate enclosure costs I/O connectors are sealed M8 pico or M12 DC micro styles 8-point and 16-point self-configuring I/O provides flexibility for any input/output combination Removal and Insertion Under Power allows module replacement without impacting the network operation Isolated auxiliary power maintains power to the outputs if main power fails Outputs electronically protected from failing with option to auto-restart or latch off Complies with Open DeviceNet Vendor Association, Inc. (ODVA) conformance test software 8 or 16 digital points Mounting Horizontal / Vertical Panel or DIN rail mounted On-Machine Panel Operating Power 120V AC / 24V DC 24V DC Standards/ Approvals UL/cUL Listed, CE certified IP65, IP66, IP67K, NEMA 4X, culus, CE, C-Tick See page 4-31 See page 4-33 4-30 Visit our website: www.ab.com/catalogs Rockwell Automation
6 / 2011 CompactBlock LDX I/O Blocks Bulletin 1790D Small, easy expandable block I/O products with universal sink/source inputs Digital bases support up to 3 discrete expansion blocks (80 I/O's) and analog bases support up to 2 discrete expansion blocks Cost-effective I/O product line for light industrial and commercial automation Selectable terminations (D-shell or screw terminations) Wide breadth of I/O's including discrete, analog, thermopcouple and RTD bases for different networks and discrete expansion blocks Discrete I/O DeviceNet Bases DNet LDX, 16 sourcing output base, D-shell connector DNet LDX, 24V DC, 16 sinking output base, D-shell connector DNet LDX, 6 relay output base, D-shell connector DNet LDX, 24V DC, 16 universal input base, D-shell DNet LDX, 24V DC, 32 universal input base, D-shell DNet LDX, 24V DC, 8 univ In/8 source output base, D-shell DNet LDX, 24V DC, 8 univ In/8 sink output base, D-shell DNet LDX,120V AC, 6 output base, terminal block DNet LDX, 24V DC, 16 source output base, terminal block DNet LDX, 24V DC, 32 source output base, terminal block DNet LDX, 24V DC, 16 sinking output base, terminal block DNet LDX, 24V DC, 32 sinking output base, terminal block DNet LDX, 6 relay output base, terminal block DNet LDX, 24V DC, 16 universal input base, terminal block DNet LDX, 120V AC, 8 input base, terminal block DNet LDX, 24V DC, 8 univ in/8 source output base, terminal block DNet LDX, 24V DC, 16 univ in/16 source output base, terminal block DNet LDX, 24V DC, 8 univ in/8 sink output base, terminal block DNet LDX, 24V DC, 16 univ in/16 sink output base, terminal block 1790D-0B16 1790D-0V16 1790D-0W6 1790D-16BV0 1790D-T32BV0 1790D-8BV8B 1790D-8BV8V 1790D-T0A6 1790D-T0B16 1790D-T0B32 1790D-T0V16 1790D-T0V32 1790D-T0W6 1790D-T16BV0 1790D-T8A0 1790D-T8BV8B 1790D-T16BV16B 1790D-T8BV8V 1790D-T16BV16V Rockwell Automation Visit our website: www.ab.com/catalogs 4-31
Bulletin 1790D CompactBlock LDX I/O Blocks, continued Expansion Block I/O LDX I/O, 24V DC, 16 source out expansion, D-shell LDX I/O, 24V DC, 16 sink out expansion, D-shell LDX I/O, 8 relay out, expansion, D-shell LDX I/O, 24V DC, 16 universal in expansion, D-shell LDX I/O, 24V DC, 8 univ in/8 source out expansion, D-shell LDX I/O, 24V DC, 8 univ in/8 sink out expansion, D-shell LDX I/O,120V AC, 8 output expansion module, terminal block LDX I/O, 24V DC, 16 source out expansion, terminal block LDX I/O, 24V DC, 16 sink out expansion, terminal block LDX I/O, 8 relay out, expansion, terminal block LDX I/O, 24V DC, 16 universal in expansion, terminal block LDX I/O,120V AC, 8 input expansion module, terminal block LDX I/O, 24V DC, 8 univ in/8 source out expansion, terminal block LDX I/O, 24V DC, 8 univ in/8 sink out expansion, terminal block 6 / 2011 1790-0B16X 1790-0V16X 1790-0W8X 1790-16BV0X 1790-8BV8BX 1790-8BV8VX 1790-T0A8X 1790-T0B16X 1790-T0V16X 1790-T0W8X 1790-T16BV0X 1790-T8A0X 1790-T8BV8BX 1790-T8BV8VX Analog I/O DeviceNet Bases DeviceNet LDX, 4 input RTD base, D-shell connector DeviceNet LDX, 4 input thermocouple base, D-shell connector DeviceNet LDX, 2 output analog current base, D-shell connector DeviceNet LDX, 2 output voltage analog base, D-shell connector DeviceNet LDX, 4 input analog current base, D-shell connector DeviceNet LDX, 4 input voltage analog base, D-shell connector DeviceNet LDX, 4 input RTD base, terminal block DeviceNet LDX, 4 input thermocouple base, terminal block DeviceNet LDX, 2 output analog current base, terminal block DeviceNet LDX, 2 output voltage analog base, terminal block DeviceNet LDX, 4 input analog current base, terminal block DeviceNet LDX, 4 input voltage analog base, terminal block 1790D-4R0 1790D-4T0 1790D-N0C2 1790D-N0V2 1790D-N4C0 1790D-N4V0 1790D-T4R0 1790D-T4T0 1790D-TN0C2 1790D-TN0V2 1790D-TN4C0 1790D-TN4V0 See publication 1790-PP002 or 1790D-TD001 for complete product information. 4-32 Visit our website: www.ab.com/catalogs Rockwell Automation
6 / 2011 ArmorBlock Digital I/O Blocks Sealed housing rated for IP-69K and NEMA 4X eliminate enclosure costs. Low installation cost and easy to replace without rewiring because industry-standard M12 DC micro connectors are used for connection to the DeviceNet network and auxiliary power supply. I/O connectors are sealed M8 pico or M12 DC micro styles. 8-point and 16-point self-configuring I/O provides flexibility for any input/output combination. Removal and Insertion Under Power makes it possible to replace a module without impacting the network operation. Isolated auxiliary power maintains power to the outputs if main power fails so that you can have the option of holding outputs in their last state. Outputs electronically protected from failing with option to autorestart or latch off. Complies with Open DeviceNet Vendor Association, Inc. (ODVA) conformance test software. Bulletin 1732 ArmorBlock I/O ArmorBlock I/O DeviceNet DeviceNet, Input Module, 8 Sink Inputs, Pico (M8) connector DeviceNet, Input Module, 8 Sink Inputs, DC Micro (M12) connector DeviceNet, Input Module, 16 Sink Inputs, DC Micro (M12) connector DeviceNet, Input Module, 16 Sink Inputs, DC Micro (Mini) connector DeviceNet, Output Module, 8 Source Outputs, Pico (M8) connector DeviceNet, Output Module, 8 Source Outputs, DC Micro (M12) connector DeviceNet, Output Module, 16 Source Outputs, DC Micro (M12) connector DeviceNet, Output Module, 16 Source Outputs, DC Micro (Mini) connector DeviceNet, Self-configuring Module, 8 point I/O, Pico (M8) connector DeviceNet, Self-configuring Module, 8 point I/O, DC Micro (M12) connector DeviceNet, Self-configuring Module, 16 point I/O, DC Micro (M12) connector DeviceNet, Self-configuring Module, 16 point I/O, DC Micro (Mini) connector 1732D-IB16M12M12 1732D-IB16M12MINI 1732D-OB16M12M12 1732D-OB16M12MINI 1732D-16CFGM12M12 1732D-16CFGM12MN ArmorBlock I/O EtherNet/IP EtherNet, Input module, 16 points, DC Micro (M12) connector EtherNet, Output module, 16 points, DC Micro (M12) connector EtherNet, Self-configuring, 16 points, DC Micro (M12) connector 1732E-IB16M12 1732E-OB16M12 1732E-16CFGM12 ArmorBlock I/O EtherNet/IP Dual Port EtherNet/IP Dual Port, Input Module, 16 points, DC Micro(M12) connector EtherNet/IP Dual Port, Input Module, 16 points, Diagnostics, DC Micro(M12) connector EtherNet/IP Dual Port, 8 Inputs, 8 Outputs, Diagnostics, DC Micro(M12) connector EtherNet/IP Dual Port, Output Module, 16 points, DC Micro(M12) connecto EtherNet/IP Dual Port, Output Module, 16 points, Diagnostics, DC Micro(M12) connector EtherNet/IP Dual Port, Self-configuring Module, 16 points, DC Micro(M12) connector 1732E-IB16M12R 1732E-IB16M12DR 1732E-8X8M12DR 1732E-OB16M12R 1732E-OB16M12DR 1732E-16CFGM12R Rockwell Automation Visit our website: www.ab.com/catalogs 4-33
Bulletin 1732 ArmorBlock I/O Cables and Cordsets The Cable and Cordset tables list the most common cable, patchcords, and cordsets for the I/O module. You can also find additional information on selecting cables and cordsets for ArmorBlock I/O in these publications: On-Machine Connectivity Catalog http://literature.rockwellautomation.com/idc/groups/literature/documents/ca/m116-ca001_-en-p.pdf On-Machine Solutions Selection Guide http://literature.rockwellautomation.com/idc/groups/literature/documents/sg/onmach-sg001_-enp.pdf ArmorBlock I/O Cables Recommended Male For Using: Recommended Patchcord (double-ended) Cordset (single-ended) 2 inputs per connector 879D-F4ACDM-x 879-C3AEDM4-5 1 input per connector 889D-F4ACDM-x 889D-M4AC-x 3-pin pico connectors 889P-F3ABPM-x 4-pin pico connectors 889P-F4ABPM3-x 889P-M3AB-y 2 inputs per connector 879D-F4ACDM-x 1 input per connector 889D-F4ACDM-x 879-C3AEDM4-5 3-pin pico connectors 889P-F3ABPM-x 889P-M3AB-y 4-pin pico connectors 889P-F4ABPM3-x 889P-M3AB-y 2 inputs per connector 879D-F4ACDM-x 879-C3AEDM4-5 1 input per connector 889D-F4ACDM-x 889D-M4AC-x 3-pin pico connectors 889P-F3ABPM-x 889P-M3AB-y 4-pin pico connectors 889P-F4ABPM3-x x = length in meters (1, 2, 3, 5, and 10 standard). y = length in meters (2, 5, and 10 standard). ArmorBlock DeviceNet and Auxiliary Power Cables Recommended DeviceNet Cable Recommended Auxiliary Power Cables KwikLink Flat Media system standard drop cable: Standard Cordset (single-ended): 1485K-PzF5-R5 889D-F4AC-y Thick Round system standard drop cable: Standard Patchcord (double-ended): 1485R-PzM5-R5 889D-F4ACDM-x Thin Round system standard drop or trunk: 1485R-PzR5-D5 x = length in meters (1, 2, 3, 5, and 10 standard). y = length in meters (2, 5, and 10 standard). Rockwell_Connectivity_Distributed_IO_Overview_en_0611.pdf Helsinki tel. +358 9 540 4940 automation@klinkmann.fi St. Petersburg tel. +7 812 327 3752 klinkmann@klinkmann.spb.ru Moscow tel. +7 495 641 1616 moscow@klinkmann.spb.ru Yekaterinburg tel. +7 343 376 5393 yekaterinburg@klinkmann.spb.ru Samara tel. +7 846 273 95 85 samara@klinkmann.spb.ru Кiev tel. +38 044 495 33 40 klinkmann@klinkmann.kiev.ua Riga tel. +371 6738 1617 klinkmann@klinkmann.lv Vilnius tel. +370 5 215 1646 post@klinkmann.lt Tallinn tel. +372 668 4500 klinkmann.est@klinkmann.ee Мinsk tel. +375 17 200 0876 minsk@klinkmann.com