Stand Alone SLIM-DMX Interface

Similar documents
Stand Alone 512 channels DIN-DMX Interface

STANDALONE WALL INTERFACE USB-DMX SLIM V.1.5.0

512 channels WIFI-DMX Interface

STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.0.5

STANDALONE INTERFACE USB-DMX DIN V 1.6.1

STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1

Hardware technical specifications Front Face of the 512 / 1024 channels interfaces LED 7-segments display operation:...

INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.0.5

INTERFACES USB-DMX 512 CHANNELS V.1.0.6

INTERFACES USB-DMX 1024 CHANNELS V.1.0.6

Software and Hardware Data-sheet

LP32. Package Content: Small package + 1 USB cable + 1 USB to DMX Interface (3 Pin XLR)

lumentouch SPECIFICATION SHEET Client: Project name: Order #: Type: Qty: FEATURES AND BENEFITS PACKAGE CONTENT HOW TO ORDER LTO

ArtDMX DMX control software V1.4

Сенсорный DMX контроллер STICK-DE3

Настенный DMX контроллер STICK + WiFi

SENSA DMX CONTROLLER KIT SAP code Pre-wired DMX Controller kit for DIN rail mounting

STICK-KE1. Sunlite Touch Sensitive Intelligent Control Keypad. Overview

**CHECK PIN CONFIGURATIONS. APPLYING POWER TO THE DMX INPUT WILL DAMAGE THE CONTROLLER**

Wireless DMX Control. Show Performer DMX Controller. Stage Desk 48 DMX Controller

DMX-RGBW-128C. Overview

Colour Change Driver All RGB luminaires are supplied complete with RJ45 plug for simple connection into a colour change driver.

AbstractAVR. Ledbuddy controller. Ledbuddy Panel User Manual 2009 Abstract AVR and Sabre Technology Tel:

OT EASY 60 II. LED control unit Operating instructions

LCD-1 CD-LCD1-01 PRODUCT OVERVIEW. Product. Description. Specifications SKU: LCD-1. 5-Button Scene Controller

IN LIGHTING CONTROL DMX EP-TOUCH-1 CONTROLLER THE INDUSTRY STANDARD. Flat wall mounted lighting controller. State of the art design and technology

VBAR 270. User Manual. Version 1.2

LED Controls. Lighting Controls. LED Controls

TABLE OF CONTENTS 1. Safety Instructions 2. Technical Specifications 3. Installation 4. How to Connect the Fixture 5. DMX512 Connections 6.

E600 VX01 Installation guide

PX 227. DMX Demux 8. Manual

4 Channel DMX Driver Instruction Manual

Chapter 1 Introducing the OM-USB Functional block diagram... 5

Satellite INSTALLATION GUIDE

Infrared Digital Scouting Camera User s Manual Scouting Camera SG560K-8mHD

Quick Reference Guide

V2 LED SOFTLIGHT USER GUIDE

ColourChaser Touch. Installation Guide

CW-WW LEDWash USER MANUAL

Neets Control QueBec P/N#: P/N#: User Manual

Technical data. General specifications. factory setting: 125 ms Memory Non-volatile memory Write cycles Indicators/operating means

Cobra Dimmer Master DMX Controller User Manual

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Full Color Digital Scouting Camera. User s Manual Scouting Camera SG860C-HD

SYNCHRONIZE DIGITAL CLOCK SYSTEM RS 485 DIGITAL CLOCK MODEL NO : RS485 CLK VER 1.0 DYNATEK

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

705 INSTALLATION MANUAL

ALPHACallisto Discrete Inputs

The user connects our device to his WiFi Network. Please see the instructions for connecting to the WiFi at

TM251MESC controller M251 Ethernet CAN

Installation Instructions for the RGB DMX Stick 3 Controller

Instruction Manual. G.R.A.S. 12AA 2-Channel Power Module with gain, filters and SysCheck generator. LI April 2015

Building Roads. Page 2. I = {;, a, b, c, d, e, ab, ac, ad, ae, bc, bd, be, cd, ce, de, abd, abe, acd, ace, bcd, bce, bde}

>dawn FC OUTDOOR USE

LLM. Digital Input Channels. Mount DIN. Warranty RAIL. Manage multiple lights operating in continuous, Multi-Drive, or OverDrive modes

Pro Series LED Controllers Part numbers: pro-4-in-1-receiver, dim-pro-knob-us-w dim-pro-knob-wa, dim-pro-knob-rgb, rgbw-pro-touch, rgb-pro-remote

Connecting a Cisco Output Module

MGate 5105-MB-EIP Quick Installation Guide

TPM Applications. Features. Optional Items. Packing List. Ordering Information. Industrial 10.4 LED Projected Capacitive Multi-touch Display

TM241CEC24R controller M IO relay Ethernet CAN master

User Manual. cmt-svr Startup Guide

IN LIGHTING CONTROL DMX EP-TOUCH-3 CONTROLLER THE INDUSTRY STANDARD 78% Flat wall mounted lighting controller. State of the art design and technology

LLM. Digital Input Channels. Mount DIN. Warranty RAIL. Manage multiple lights operating in continuous, Multi-Drive, or OverDrive modes

Installation Instructions for the RGB DMX Stick 3 Controller

IB080QM65VA3 Part Number

FAST_EnergyCam-Communication-Interfaces.doc 7/7/2016 Page 1 of 6

DMX-Player L MK2. User Manual

TM241CEC24T. Main. 14 (remote I/O architecture) W with max number of I/O expansion module ma fast input. 2.

STICK-KE2. Sunlite Touch Sensitive Intelligent Control Keypad. Overview

Party Par. User Manual. Order codes: EQLED015 - Black housing EQLED015B - Polished housing

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

LED PANEL. User Manual Please read the instructions carefully before use LED-7TC. Innovation, Quality, Performance 15-

Infrared Digital Scouting Camera. User s Manual Covert Deuce

ULN2065B SWITCH BOARD

CP 64 BD15 CP 64 PD15

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

LED Accu Penta 9x12W RGBWAU

User s manual. Easy Scan XT3 LED

User Manual. Logic Timer Module. SB-DN-Logic960.

User Manual Equinox 2m Flight Cased DMX LED Flame Machine Order code: FLAM12

AL-WS-010v smart 0-10v Dimmer switch with 3-Way, DC power and DALI

light-drive elite Setup Manual

Xenon Flash Digital Scouting Camera. User Manual SG565F-14mHD

WECS II 512/02 and WECS II 1024/02. Power. Electrical control systems. Innovation made by OASE NEW

MGate 5111 Quick Installation Guide

ATBRFN. Radio Frequency (RF) Based Trailer Tracking System. Datasheet (ATBRFN) 1

DATASHEET EFFI-Sharp Range : EFFI-Sharp Last update : May 16, LED Pattern projector. EFFI-Sharp. Camera

CPM1A MICRO PROGRAMMABLE CONTROLLERS

Compact UV wash featuring ultra wide coverage and high-output COB LED

Dual channel temperature logger with two voltage inputs 0-5V Instruction Manual

User Manual INTRODUCTION SAFETY INFORMATION BACK PANEL DIAGRAM. Please read the instructions carefully and before use.

Infrared Digital Scouting Camera User s Manual Scouting Camera SG560K-8M

PAR56 10MM UV LED PAR. user manual

Robocolor II System. users guide

Basics of UART Communication

TCNM-ACBB1 Installation Manual

UV Spectra Batten 12 x 5W UV LEDs

1020 / 1022 INSTALLATION MANUAL

Quick Reference Guide

Transcription:

Stand Alone SLIM-DMX Interface V.1.0.1 Summary Technical features of the interface P.02 General pinout and device's connector P.02 Bottom view of the interface P.03 Top view of the interface P.03 Interfaces Master/Slave connections P.04 Triggers configuration with the software P.04 LED buttons triggers P.05 Infra-red remote triggers P.05 External contacts triggers P.05 DMX IN and triggers via another DMX signal P.05 Time triggers with clock and calendar P.06 Selection of the Master/Slave interfaces P.07 SLIM-DMX interface datasheet 1

Technical features of the interface Input/Output Connectors: Screw terminal (4 pins + 5 pins) Number of DMX Outputs: 512 or 1024 (PC + Stand Alone) External triggers: x4 contacts (5V.) multiplexed to 15 contacts max Master/Slave connection:, 3 wires for 16 connected interfaces max Infra Red connection: via an external IR module and 3 connection wires DMX Speed: 1 to 45 Hz, MaB, Bk USB Mode: Stand Alone Mode: Internal Clock (RTC): Internal calendar: Backups of the internal clock:, 3 weeks without power Internal memory: (4 MB) Memory Capacity: 4000 steps with 512 channels, 100 000 steps with 16 channels Display of signal states: DMX LED + USB LED Data display: 7 segment LED display Power supply input: 9-36V or 5V with USB Contact Input Voltage (stand-alone): 5 V Input Current: 80 to 200 ma Power: 2 W CPU's technology: 32 bits Dimensions: H : 127 mm, W : 110 mm, D : 19 mm Weight: 250 g Color: Black Operating temperatures: -25 à +70 C Certificates: CE, RoHS General pinout and device's connector SLIM-DMX interface datasheet 2

Bottom view of the interface External connectors: 1: GND 2: 5V. DC External trigger voltage 3: External trigger A 4: External trigger B 5: External trigger C 6: External trigger D 7:Master/Slave Clock 8: Master/Slave Data 9: External input power 9-36 V (mandatory) 10: GND 11: Infra Red signal 12: DMX2 - data 13: DMX2 + data 14: DMX1 - data 15: DMX1 + data 16: DMX ground External wall mounting: 17: America standards 18: Europe + Asia standards PC connection: 19: USB connector (PC) 5V. DC Top view of the interface Scene triggering buttons: 20: Scene 1 On/Off 21: Scene 2 On/Off 22: Scene 3 On/Off 23: Scene 4 On/Off 24: Scene 5 On/Off 25: Scene 6 On/Off 26: Scene 7 On/Off 27: Scene 8 On/Off 28: Scene 9 On/Off 29: Scene 10 On/Off Command buttons: 30: Mode selection (trigger, speed, dimmer) 31: - decrease values 32: + increase values Display and LED: 33: Current mode LED 34: 7-segment LED display SLIM-DMX interface datasheet 3

+ and buttons operation: In trigger mode (2 LED off) + and buttons allows to choose a different scene. You have to hold + and buttons for 2 seconds to validate the selection and play the new scene. Mode button and LEDs operation: LED1 + LED2 off: the interface is in trigger mode via the buttons 1 to 10. + and buttons allows to choose a different scene. LED1 on: Press 1 time the mode button, the interface is in speed mode, + and buttons allows to increase or decrease the speed of the current scene. LED 2 on: Presse a 2 nd time the mode button, the interface is in general intensity mode (DIMMER), + and buttons allows to increase or decrease the general light intensity of the scenes. LED 7-segment display operation: In trigger mode, the 7 segment display gives the current scene number. The 00 value indicates that no scene is playing and the SLIM DMX interface send nulls (0x00) on all output DMX channels. In speed mode, the display indicates the speed of the current scene, values are between -9 and 9. In dimmer mode, the display indicates the general intensity, values are between -9 and 9. External triggers operation: Connect the pins to 5V following these combinations: 01 = A ; 02 = B ; 03 = AB ; 04 = C ; 05 = AC ; 06 = BC ; 07 = ABC ; 08 = D ; 09 = AD ; 10 = BD ; 11 = ABD ; 12 = CD ; 13 = ACD ; 14 = BCD ; 15 = ABCD. By default, the interface gives 4 external contacts (01, 02, 04, 08). To obtain 15 external contacts, you have to use a de-multiplexing interface in order to go from 4 to 15 possible combinations. Infra Red triggers operation: An external module with an Infra Red receiver is necessary. It can be connected to the following pins: GND (pin 1 or 10) + 5V. DC out (pin 2) + IR Signal (pin 11). Interfaces Master/Slave connection Master/Slave mode allows to synchronize scenes and trigger actions of several interfaces together. To use interfaces as Master/Slave, you have to connect the interfaces each others from the screw terminals. You need to connect together the pins M/S Data, M/S CLK and GND, as following: Interfaces configured as slave will strictly follow the clock, triggers and information providing by the master interface. Only one master interface at a time. Triggers configuration with the software The Stand Alone mode of the software enables to configure and personalize all the triggers. The information will be directly saved in the DMX interface memory with the memory writing function. SLIM-DMX interface datasheet 4

LED Buttons trigger Stand alone mode offers 10 buttons that represents the interface LED buttons. From the scene list of the stand alone mode, you need to drag and drop a scene on any button to assign a button number. It's possible to replace a scene by an other or to remove it by pulling it out of the list. Infra Red remote triggers Stand alone mode offers up to 10 triggers with the Infra Red remote. By selecting a scene in the list, it's possible to choose the remote button number (from 01 to 10) to trigger the scene. The other IR remote functions will work as well as the SLIM DMX interface. (Speed, dimmer, scene +, scene -, off). External contact triggers The Stand Alone mode offers up to 15 external possible triggers. By selecting a scene in the list, it's possible to choose the external contact number (from 01 to 15) to trigger the scene. By default, the interface gives 4 external contacts (01, 02, 04, 08). To obtain 15 external contacts, you have to use a de-multiplexing interface in order to go from 4 to 15 possible combinations. DMX IN and triggers via another DMX signal The Stand Alone mode offers up to 512 DMX IN channel triggers and up to 255 DMX trigger values per channel. By selecting a scene in the list, it's possible to choose the channel number and the DMX value to trigger the scene. The scene will play when the value of the DMX channel is reached or exceeded. SLIM-DMX interface datasheet 5

Time triggers with clock and calendar The Stand Alone mode has an internal clock and a calendar. It's possible to assign a time trigger on every scene of the list. By selecting a scene on the list, it's possible to choose the start and end dates and hours and days of the week. You can thus create a lot of scenarios. Start schedule: Date + hour when trigger is active. Date may be anterior or ulterior at the current date. The scene will be triggered in the case of an ulterior date. End schedule: Date + hour when triggers is not active anymore. The scene can't be stop at the indicated hour and date. Stop time allows to define an important interval when the trigger stays active, there may be several years between start and stop time. Stop a scene at an specific hour: In that case, you need to use 2 scenes. The first one to play illuminations on the wished start time. The second one neutral and without DMX levels to stop the current scene at its wished start time. In this simple example, the illumination scene is playing normally and the stop scene will replace it during the stop period. Day of the week: The scene will trigger at the time of the start schedule for all the selected days of the week during the defined period with start and stop schedules. Save and recover the last scene after the power cut off: Scenes with a start schedule and a stop schedule are set on a defined time space and can be memorized. The interface save the last scene played before the power cut off and recover it when the power is restored. The scene must obligatory include a start schedule and a stop schedule activate this option. SLIM-DMX interface datasheet 6

Selection of the Master/Slave interfaces The Stand Alone mode allows to choose 1 interface and to configure this interface like Master when you have several interfaces connected to your computer USB ports. From the interface list, it is possible to choose only one to be the Master, all the other one will be configured as slave by default. The interfaces are always ordered by serial number ascending order. SLIM-DMX interface datasheet 7