Fast Bus Busbar System

Similar documents
Fast Bus Fast Bus Busbar System

Busbar Systems. 10/2 Introduction. 10/3 General data. 40 mm Busbar Systems 10/6 Introduction 10/7 Base assemblies up to 400 A

Siemens AG Busbar Systems SENTRON. Configuration. Edition Manual. Answers for infrastructure and cities.

5/2 Product overview. 5/3 Distribution board components. 5/9 Built-in components. 5/17 Mounting components 5. Siemens ET B1 10/2009

SR60 Busbar System 2/1 2/2. General Data. 2/3 Busbar routing. 2/7 Mounting components. 2/13 Accessories

Load Feeders and Motor Starters for Use in the Control Cabinet

Siemens AG RA6 Fuseless Compact Starters. Catalog News LV 1 N April 2008 SIRIUS.

SENTRON SIVACON ALPHA

SENTRON SIVACON ALPHA

Load Feeders and Motor Starters for Use in the Control Cabinet

Components for Distribution Systems

sirius Switching. Protecting. Starting. SIRIUS Product Overview

Load Feeders, Motor Starters and Soft Starters

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Industrial Controls Product Catalog RA64 / 3RA65 up to 32 A for mounting rail, surface,

4 COMBINATION SIRIUS. SIRIUS 3RA6 Compact Starters 4/2. General data

IEC Contactors. Auxiliary Contact Blocks GENERAL

Protection Equipment

Siemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A

3RA13, 3RA14 Contactor Assemblies

3RV1 Circuit-Breakers

C E R T I F I C A T E O F C O M P L I A N C E

SIRIUS modular system

Contactors and Contactor Assemblies

TeSys IEC Contactors and Overload Relays

Solid-State Contactors

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

SIRIUS modular system

Solid-State Switching Devices

Switches 6/1. 6/4 Introduction. 6/5 5TE8 control switches. 6/7 5TE4 8 pushbuttons. 6/9 5TE8 On/Off switches. 6/11 5TE1 switch disconnectors

SIRIUS Modular System

8WH5 Combination Plug-In Terminals

For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

Switching, protecting, starting and monitoring with the highly flexible modular system usa.siemens.com/controls

Siemens AG KD Switch Disconnectors SENTRON. Edition December Answers for infrastructure and cities.

RiLine Compact The smart power distribution system

System-based switching, protecting, starting. SIRIUS Modular System. sirius

3RT, 3TB, 3TF Contactors for Switching Motors

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

Switch Disconnectors, Main and EMERGENCY-STOP Switches

IEC Power Control Contactors and Contactor Assemblies

Siemens AG Highly flexible system-based switching, protecting and starting. SIRIUS Modular System. Answers for industry.

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

System-based switching, protecting, starting. SIRIUS Modular System. sirius

Application Switchgear for industrial and advanced commercial applications. U e V AC 277/480 Y V DC 60

Industrial Controls Product Catalog 2017

Close Protection from Moeller. miniature branch circuit breakers miniature supplementary protectors

SIEMENS AG For Efficiency and Reliability in the Control Cabinet. The SIRIUS 3RA6 Compact Starter SIRIUS. Answers for industry.

1.1. Contactors and Starters... Contents Description Relays and Timers... Miniature Controls... Manual Motor Protectors. XT IEC Power Control

Air Circuit Breakers. 1/2 Introduction

Click 'n' Go: SIRIUS Modular System SIRIUS. Highly flexible system-based switching, protecting and starting. Answers for industry.

Contactors and Contactor Assemblies

SIMOCODE 3UF Motor Management and Control Devices

Solid-State Switching Devices

920 Remote Control (RC) Switches

US Catalog July 2016 SMISSLINE TP

Miniature Circuit Breakers for Railway Applications

C E R T I F I C A T E O F C O M P L I A N C E

IEC Power Control Overload Relays

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

SIGUARD Safety Combinations and Safe Load Feeders. safety INTEGRATED

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

ASCO 920 Remote Control (RC) Switches

IEC Power Control Overload Relays

SITOP in the SIMATIC Design

File E Project 00ME December 18, 2000 REPORT COMBINATION CONTROLLERS. Siemens AG Amberg, Germany

Approved Standards. Motor Protection Circuit Breaker (MPCB) J7MN. MPCB system (motor protection CLASS 10) Auxiliary contact modules.

Miniature Circuit Breakers and Supplementary Protectors. Contents

Go to:

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole) I cs 7,5 ka

SIRCO Load break switches for power distribution from 125 to 5000 A

Application Switchgear for industrial and advanced commercial applications. U e V AC 240/ (per pole)

SIRIUS 3RB2 Solid-State Overload Relays

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

US CATALOG SMISSLINE TP

Siemens AG I IA CE CP R&D-VI 4 WERNER-VON-SIEMENS-STRASSE AMBERG, GERMANY

Overload Relays 3RU Thermal Overload Relays 3RB Solid State Overload Relays 3UF SIMOCODE pro Intelligent Motor Protection

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Cat. No. 140M-F M-D8E-B

Micro Contactor MA Series

Max. Short Circuit Current [ka] Standard Motor Protection High Inrush Motor Protection Motor Circuit Protection 600V C-Frame

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

Controls Solid-State Switching Devices

Contactors and Contactor Assemblies

194E FA 32 E P11 P11 6

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

1.3. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZS Circuit Breaker. UL 1077 DIN Rail Supplementary Protectors

ALPHA SIMBOX Small Distribution Boards

Mini Contactors & Overloads

3RA6 Fuseless Compact Starters

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers

Overvoltage Protection Devices

Magnetic and Hydraulic-Magnetic Circuit Breaker

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

1.2. Miniature Circuit Breakers and Supplementary Protectors. Contents. WMZ Circuit Breaker. UL 489 DIN Rail Miniature Circuit Breakers

Requirements for machine approval in North America under the new NEC 2017

1/2 Introduction. SIMBOX LC 1/7 Introduction 1/8 Flush-mounting and surfacemounting. 1/9 Dimensional drawings

Application Instantaneous release response current 5-10 x In. Switching capacity Switching Capacity 15 ka (IEC/EN ) U e V AC 230/400

Transcription:

Busbar System Industrial Controls Product Catalog 2017 Section c o n t e n t s Fast Bus busbar adapter system mm system Page Selection and ordering data Busbar holders /9 Fast Bus adapter shoes /11 Incoming supply terminals /6 Copper busbar /6 Busbar covers /6 Other accessories /6 Overview /2 Introduction /3 Technical Data /3 Dimension drawings /-/1 FBCB Fast Bus circuit breakers Fast Bus combination starters FBCB Fast Bus main and feeder circuit breakers Page Selection and ordering data Fast Bus circuit breakers assemblies and kits /7 Fast Bus adapter shoes for VL breakers /8 3RA2 Fast Bus combinations starters 3RA6 Fast Bus compact starters Selection and ordering data See Section 4 (PDF was last modified on /23/18) Siemens Industry, Inc. Industrial Control Product Catalog 2017 /1

Overview Busbar adapter systems Busbar adapter systems with busbar centerline spacing of mm mm busbar system Page Page Page for sharp-edged copper busbars to DIN 46 433, width 20 mm to 30 mm, thickness mm and mm Busbar holder End and intermediate holders /6 for flat copper profiles Fast Bus main circuit breakers /7 from 0 to 00A Fast Bus circuit breakers /7 from 1 to 0A 3RA2 Combination Starters see section 4 Incoming supply terminals /6 /2 Siemens Industry, Inc. Industrial Control Product Catalog 2017

Introduction General The Fast Bus Multi-Motor Control system is a 3-phase insulated busbar system and is ideal for space saving in panel designs. The system saves considerable line side wiring and space for multi-motor panels. It is also ideal for panels where several feeder breakers are used and will save significant wiring space and wiring labor. The system is also ideal for future expansion planning. when building control panels. SIRIUS 3RV/3RT starter combinations and Siemens circuit breakers are all adaptable to Fast Bus for convenient mounting and faster replacement times. Fast Bus is ideal for industrial applications where system availability is important. Features Simple economical installation Compact design Requires fewer mounting holes Domestic and International approvals Touch safe Modular design Provision for system expansion Clip-on shoes provide mechanical and electrical connections to panel mounted busbars Main and Feeder breakers mount to busbars Benefits Saves installation time Reduces space requirements Minimizes layout time Allows flexibility for domestic and export business Protection for maintenance personnel Improves equipment mounting density Reduces time and costs associated with system expansion Reduces mounting and wiring time and provides trouble free connections Allows for quick retrofitting of breakers How to Select Fast Bus 1) Determine the required load. 2) Select method to power Fastbus. Main lug up to 800A using a single set of lugs or up to 1400A using a double set of lugs. Circuit breakers, 1A to 00A If load exceeds 00A, the CB must be separately panel mounted and fed to a main lug infeed module. 3) Select 3RV MSP & 3RT contactor components and appropriate adapter shoe or select preassembled 3RA starters. See section 4. 4) Select appropriate length busbar, busbar holders, insulation covers and any other required components. General Ratings of Fastbus System IEC Domestic Rated operating voltage 690V 0V Rated insulation voltage, IEC VDE AC 00V N/A Temperature stability Up to degrees C N/A Busbar support and adapter shoe material Glass-reinforced polyamide Same Color RAL 703, light gray Same Ampacity Busbar thickness and width x 20 mm 3/16 x 3/4 362A x 2 mm 3/16 x 1 432A x 30 mm 3/16 x 1 1/8 00A x 20 mm 3/8 x 3/4 64A x 2 mm 3/8 x 1 6A x 30 mm 3/8 x 1 1/8 76A 720mm 2 --- 1400A For technical information on E and F frame circuit breakers used as main and feeder breakers, see section 17 Thermal busbar currents, E-Cu, bare, at 3 C ambient temperature in accordance with DIN 43 6711 Busbar dimensions mm 20 x 2 x 30 x 20 x 30 x System mm Thermal current at 6 C 8 C C Busbar temperature A A A 274 362 430 327 432 13 379 00 9 427 64 670 73 76 900 Siemens Industry, Inc. Industrial Control Product Catalog 2017 /3

Introduction Fast Bus set-up The Fast Bus system is designed to be easy to use and to save set up time. 8US Busbar holders The 8US busbar holders are designed to accommodate ampacities up to 1400A. In some cases, the busbar holder will accept busbars in either mm or mm widths. Refer to page /6 for selection details. High quality material Busbar supports and fuse bases are manufactured from glassfiber reinforced, thermoplastic polyester with the color RAL 703, light gray. The material ensures excellent mechanical, chemical and electrical properties. Furthermore, the material has an extremely low flammability and meets the requirements of UL 94 V0. 8WC Busbar and busbar systems The most common size busbar for applications in the US is the 8WC03 (20 mm x mm), however there are other styles available depending on your application. Busbar systems with mm busbar center-to-center clearance have now become firmly established in the US market. The permissible busbar temperature is a decisive factor when dimensioning the busbars. The busbar temperature is dependent on the current, the current distribution, the busbar crosssection, the busbar surface, the position of the busbar, the convection and the ambient temperature. The values stated in the table on page /3 can only be considered as reference values because the conditions vary with each location. The values are based on constant current over the whole busbar length. The trend toward busbars proves most advantageous when the incoming supply is centrally located and the load is distributed symmetrically on both sides. For the assemblies of a busbar system in the feeder circuit the UL directives specify components with large clearance in air and creepage distances (see the table below). Components of the 8US1 busbar system which meet this requirement can be found in this chapter. Note: The design of an 8US1 busbar system for use in the feeder circuit always presumes the use of the UL base plate (8US19 22-2UA01) so that the clearance in air and creepage distance requirements are met. Feeder/branch circuit according to UL 08A The feeder circuit is that part of a circuit which comes in front of the last short circuit protection device (SCPD). The branch circuit is that part of the circuit which follows after the last short circuit protection device. When the 8US1 busbar system is used in a switchgear which must comply with UL directives, it is important to establish whether it is to be used in the feeder circuit or the branch circuit. Components used in the feeder circuit require larger clearance in air and creepage distances than in the branch circuit. Simple Fast Bus system The two illustrations above show the very basic items needed when setting up a Fastbus system. 8US1 Busbar holder (/6) 8US1 Ground busbar support (shown attached however can be mounted separately /6) Ground busbar available in x 20 mm to x 30 mm 8WC Busbar (8WC03 shown) FBB36 Busbar (/6) Short-circuit strength The short-circuit strength of the busbar system is dependent on the spacing of the busbar holders and on the busbar crosssection. The short-circuit strength of the whole system is dependent on the short-circuit strength of the busbar system and the components that are mounted to the system. Applications The 8US Fast Bus distribution system is ideal for control panel builders with multiple motor applications. These applications are most common in the material handling, automotive, food processing, pharmaceutical and paper processing industries. Clearance in air Creepage distance Between live parts 2.4 mm (1 inch) 0.8 mm (2 inch) Between live parts and grounded, 2.4 mm (1 inch) 2.4 mm (1 inch) non-insulated metal parts /4 Siemens Industry, Inc. Industrial Control Product Catalog 2017

Introduction Fast Bus combination starters and group installation assemblies Ratings for Group Installations per NEC 430-3 Group Installation is an approach to building multiple motor control systems in accordance with Section 430-3 of the National Electrical Code. In Group installation, multiple motor starters can be grouped under one short circuit protective device. The 3RV MSPs have been UL listed for use in Group Installations both with and without 3RT contactors when mounted on the Fast Bus system. A 3RT contactor is added when remote operation of the motor is required. Standard Installation, NEC 430-2 Group Installation, NEC 430-3 MSP Type 3RV201 3RV201 3RV202 3RV202 3RV202 3RV202 3RV203 FLA Amp Range S00 S00 S0 S0 S0 S0 S2 S3 FLA Amp Range 0.11-12. 0.11-16 3.-12. 3.-2 28-32 36-40 11-0 3RV204 28-0 The selection of components for Group Installation is a simple process of the following three steps: 1. Selection of the Branch Circuit Protective Device, fuse or circuit breaker. 2. Selection of the 3RA Motor Starter based on the motor Full Load Amps. Maximum rating of Group Branch Short Circuit Circuit Protective Device 1) 2) Current Ratings Fuse Circuit Breaker 240V 480V 0V The main fuse should be selected based on the FUSE selection procedure listed below. Circuit Breaker Selection Select a circuit breaker (CB) between: Minimum CB size (per NEC430-1): Sum of all motor FLC (per NEC table 430-) x11%. Maximum CB size (per NEC430-3c): 20% x FLC of the largest motor + FLC of all other motors. The main CB should be selected based on the CIRCUIT BREAKER selection procedure listed below. 6kA 6kA 6kA 6kA 6kA 6kA 6kA 6kA 6kA 6kA 0kA 12kA 6kA 6kA Fuse Selection Calculate the maximum fuse size per NEC430-3c. Max Fuse Size =17% x FLC of largest motor + FLC of all other motors (FLC s from NEC table 430-). 30kA 30kA 2kA 30kA Assembled Starter FLA Starter Type Frame Size Amp Range Short Circuit Current Ratings (Type E) 1) 240V 480Y/277V 0Y/347V 3RA201 3RA201 3RA202 3RA202 3RA202 S00 S00 S0 S0 S0 0.11-12. 0.11-16 0.4-12. 0.4-2 28-32 6kA 6kA 0kA 6kA 6kA 0kA 30kA 30kA 2kA 3RA203 S2 11-0 6kA 6kA 3RA204 S3 28-7 30kA 3RA204 S3 28-0 6kA 6kA 1) Branch Circuit Protective Device for 480V-Ratings: The appropriate BCPD need to be determined in accordance with the National Electrical Code, Article 430-3 and the application. The following devices are permitted: Fuses: Classes RK1, RK, J, G, T, CC or Circuit breakers: Listed Siemens type, with a marked short-circuit rating equal or larger than the available short-circuit current rating. These devices were tested for group installation use at the above levels without any upstream branch circuit device. 2) 3RA2 used as Manual Motor Controller; Branch Circuit Protective Device for 0V-Ratings: Max. Class J 0A 3) Starter sizes S00,S0 and S3 require additional type E line side terminal adaptors on the MSP for type F applications. See section 1 accessories Siemens Industry, Inc. Industrial Control Product Catalog 2017 /

mm system Revised on /23/18 Selection and ordering data Busbar holder Insulating Base Plate Busbar 3-phase End cover Busbar holder Insulating Base Plate End cover Busbar 3-phase Busbar Neuteral or PE Ground busbar holder Terminals for Round Conductors Busbar Neuteral or PE Terminals for Round Conductors Ground busbar holder 8US1922-2UA01 Description UL Current UL08A Order No. rating Compliance 1 ) Pack Base plate 3-pole system flat 230 mm x 10 mm required 8US19 22-2UA01 Units 8WC Copper Busbar with tin plating 20 mm x mm x 914 mm (36 ) for mm systems 362A yes FBB36 3 pcs 20 mm x mm x 124 mm ( ) for mm systems 362A yes FBB 3 pcs 20 mm x mm x 2000 mm (78.74 ) for mm systems 362A yes 8WC03 8US1948-2AA00 2 mm x mm x 2000 mm (78.74 ) for mm systems 4) 432A yes 8WC04 30 mm x mm x 2000 mm (78.74 ) for mm systems 00A yes 8WC0 20 mm x mm x 2000 mm (78.74") for mm systems 64A yes 8WC063 30 mm x mm x 2000 mm (78.74") for mm systems 76A yes 8WC06 720 mm 2 x 2400 mm (94.49 ) Twin T (TT) Busbar 1400A yes 8US19 48-2AA00 Busbar holder (end and intermediate) 8US1922-1AC00 3-pole with inside mounting for 20 mm and 30 mm x mm or mm yes 8US19 23-3UA01 3-pole with inside mounting for 2mm x mm or x mm 8US19 23-3AA00 8US1923-3UA01 3-pole with inside mounting for Twin T (TT) w/ end cover yes 8US19 43-3AA01 Busbar holder end cover 3-pole end cover fits 8US19 23-3UA01 and 8US1923-3AA01 required 8US19 22-1AC00 Ground Busbar holder 1-pole with inside mounting for 20 mm - 30 mm x mm or mm 2) n/a 8US19 23-1AA01 8US1923-1AA01 Cover profiles for Busbars for mm busbars up to 30 mm wide 00 mm length required 8US19 22-2AA00 for mm busbas up to 30 mm 00 mm length required 8US19 22-2BA00 8US1922-2AA00 for Twin T (TT) busbar 00 mm length required 8US19 22-2DA00 Reserve Space Cover (for covering round terminals placed on 3-phase busbar) Holder for reserve space cover 32mm height required 8US1922-2EA00 4 pcs Holder for reserve space cover 7 mm length required 8US1922-2EA01 8 pcs Reserve space cover 19mm height / 700mm length required 8US1922-2EB00 8US1922-2EB00 Feeder Lugs (mounts to all busbar sizes on this page) 3-pole terminal plate with cover 20 mm x 200 mm 16-4 AWG 80A yes SH338 3-pole terminal plate with cover 4 mm x 200 mm -2/0 AWG 17A yes 8US19 21-1BA00 3-pole terminal plate with cover 81 mm x 200 mm 2 AWG-20 MCM 440A yes 8US19 21-1AA00 3-pole terminal plate with cover 180 mm x 200 mm 20-0 MCM A yes FBT0F SH338 3-pole terminal plate 14 mm x 184 mm 300-0 MCM A yes 8US19 41-2AA03 8US1921-1BA00 3-pole terminal plate 1 mm x 184 mm for flat bars up to 800A yes 8US19 41-2AA04 32 mm x 20 mm Cover for 8US19 41-2AA03 and 04 180 mm x 200 mm x 90 mm yes 8US19 22-1GC00 1) UL 08A labeled panels require the use of components that meet the creepage and air distances of 1 air clearance and 2 creepage distance. N/A = not applicable for given item. FBT0F w/cover 2) Current rating dependent on size of busbar used. Refer to busbar selection data. /6 Siemens Industry, Inc. Industrial Control Product Catalog 2017 Product Category IEC

mm system Circuit breaker assemblies and kits Selection and ordering data Description FBCB Fast Bus circuit breakers Offer a full range of feeder circuit breakers from 1A to 20A. All kits 12A and under are pre-assembled on mm Fast Bus adaptor shoes and ready to place on the busbar. Circuit breakers A and higher are pre-packaged kits for fast user assembly and must be torqued down to the busbar prior to assembly. For VL breakers, adaptors are available for up to 00A breakers (both main and feeder orientation). See page /8. Available in 2017 2) Design UL Current Rating Breaker Frame (SCCR Rating 1) ) Feeders Circuit Breakers ED (2kA) HHED (6kA) FXD (3kA) NGG (2kA) HGG (3kA) LGG (6kA) 3 pole/0v fully assembled breakers and adaptors that quickly snap onto the Busbar. FBCB0 1A 20A 2A 30A 3A 40A 4A 0A A 70A 80A 90A 0A 1A 12A FBCB01 FBCB020 FBCB02 FBCB030 FBCB03 FBCB040 FBCB04 FBCB00 FBCB0 FBCB070 FBCB080 FBCB090 FBCB0 FBCB1 FBCB12 FBCB020H FBCB02H FBCB030H FBCB03H FBCB040H FBCB04H FBCB00H FBCB01NGG FBCB020NGG FBCB02NGG FBCB030NGG FBCB03NGG FBCB040NGG FBCB04NGG FBCB00NGG FBCB0NGG FBCB070NGG FBCB080NGG FBCB090NGG FBCB0NGG FBCB1NGG FBCB12NGG FBCB01HGG FBCB020HGG FBCB02HGG FBCB030HGG FBCB03HGG FBCB040HGG FBCB04HGG FBCB00HGG FBCB0HGG FBCB070HGG FBCB080HGG FBCB090HGG FBCB0HGG FBCB1HGG FBCB12HGG FBCB01LGG FBCB020LGG FBCB02LGG FBCB030LGG FBCB03LGG FBCB040LGG FBCB04LGG FBCB00LGG FBCB0LGG FBCB070LGG FBCB080LGG FBCB090LGG FBCB0LGG FBCB1LGG FBCB12LGG 3 pole/0v kitted components for customer assembly that require the adaptor to be torqued down to the Busbars prior to assembly. Design Main Circuit Breakers A 17A 200A 22A 20A UL Current Rating FXD (2kA) 3) HFXD (6kA) FBCB FBCB17 FBCB200 FBCB22 FBCB20 Breaker Frame (SCCR Rating) 3 pole/0v kitted components for customer assembly that require the adaptor to be torqued down to the Busbars prior to assembly. 0A 12A A 17A 200A 22A 20A FBCB0M FBCB12M FBCBM FBCB17M FBCB200M FBCB22M FBCB20M FBCB0M-HB FBCB12M-HB FBCBM-HB FBCB17M-HB FBCB200M-HB FBCB22M-HB FBCB20M-HB FBCB20M 1) UL Short Circuit Current ratings are based on 480V. Contact Siemens for 0 V ratings. 2) Check Industry Mall for availability. 3) FBCB0M -12M SCCR = 2kA @ 480V FBCBM -20M SCCR = 6kA @ 480V Product Category IEC Siemens Industry, Inc. Industrial Control Product Catalog 2017 /7

mm system Busbar adapters and device holders Selection and ordering data 8US21 1-DM07 8US21 -AM00 Busbar device adapters For SIRIUS Number Rated Connecting of mounting rails cables current (3 mm) Adapter Adapter Rated UL08A 1) length width voltage compliance UL Order No. Pack units A AWG mm mm V kg Weight per PU approx. Size S00/S0 MSPs 1 2 12 182 4 0 yes 8US12 1-DM07 0.183 Contactors 1 2 12 182 4 0 yes 8US12 1-DM07 0.183 + Overload relays Direct start load 1 2 12 182 4 0 yes 8US12 1-DM07 0.183 feeders Reversing feeders Busbar adapters 1 2 12 182 4 0 yes 8US12 1-DM07 0.183 + Device holders 1 -- -- 182 4 0 yes 8US12 0-AM00 0.18 + Connecting -- -- -- -- -- -- yes 8US19 98-1AA00 0 units 0.0 plates Size S00/S0 Cage Clamp Direct start load 1 12 14 182 4 0 yes 8US12 1-CM47 0.190 feeders Size S2 MSPs 1 0 8 182 0 vyes 8US12 61-FM08 0.263 Contactors 1 0 8 182 0 yes 8US12 61-FM08 0.263 + Overload relays Direct start load 1 0 8 24 0 yes 8US12 61-FP08 0.292 feeders Reversing feeders Busbar adapters 1 0 8 242 0 yes 8US12 61-FP08 0.292 Busbar adapters 1 -- -- 242 0 yes 8US12 -AM00 0.202 + Device holders -- -- -- 242 0 yes 8US12 -AP00 0.243 + Connecting -- -- -- -- -- -- yes 8US19 98-1AA00 0 units 0.0 plates Size S3 80 4 21 72 0 yes 8US12 11-4TR00 4) 0.69 1 0 -- 200 72 0 yes FBS0723R 0.90 -- 0 -- 200 72 0 yes FBS0722 0.6 8US12 11-4TR00 8US12 13-4AQ03 For VL UL circuit breakers 2) VL UL, DG frame VL20 UL, FG frame VL400 UL, JG frame VL400X UL, LG frame -- Tubular contacts -- 20 Tubular contacts -- 400 Tubular contacts -- 40 3) contacts Tubular 190 0 yes 8US12 13-4AQ03 1.020 190 0 yes 8US12 13-4AQ03 1.020 296 140 0 yes 8US12 13-4AH00 1.900 296 140 0 yes 8US12 13-4AH00 1.900 8US12 13-4AH00 1) UL 08A labeled panels require the use of components that meet the creepage and air distances of 1 air clearance and 2 creepage distance. N/A = not applicable for given item. 2) For use with mm x 30mm and twin T (TT) busbars only. Adaptors can be configured for main or feeder breakers applications. 3) For use with maximum 00A circuit breaker. Circuit breakers greater than 00A must be panel mounted off the busbar system and fed to the busbars via an infeed module. See page /6. 4) Rated 0A @ 480V. Rated 0A @ 0V with Class J Fuses. /8 Siemens Industry, Inc. Industrial Control Product Catalog 2017 Product Category IEC

mm system Terminals and accessories Selection and ordering data Terminals Terminals Description Max Amps Width UL08A Compliance 1 ) Order No. List Pack Price $ Units Terminals for round conductors mm busbar thickness 3) 12 mm x mm 180 16-6 AWG 8US19 21-2AA00 1 mm x mm 270 12-2 AWG 8US19 21-2AB00 20 mm x mm 400 6-2/0 AWG 8US19 21-2AD00 2 mm x mm 440 6-20 MCM 8US19 21-2AC00 30 mm x mm 180 16-6 AWG 8US19 21-2AA01 270 12-2 AWG 8US19 21-2AB01 400 6-2/0 AWG 8US19 21-2AD01 440 6-20 MCM 8US19 21-2AC01 20 mm x mm, 2 mm x mm 00 3/0-30 MCM 8US19 41-2AA01 30 mm x mm 0 300-0 MCM 8US19 41-2AA02 mm bar thickness 12 mm x mm 3) 180 16-6 AWG 8US19 21-2BA00 1 mm x mm 3), 20 mm x mm 270 12-2 AWG 8US19 21-2BB00 2 mm x mm, 30 mm x mm 400 6-2/0 AWG 8US19 21-2BD00 440 6-20 MCM 8US19 21-2BC00 180 16-6 AWG 8US19 21-2BA01 270 12-2 AWG 8US19 21-2BB01 400 6-2/0 AWG 8US19 21-2BD01 440 6-20 MCM 8US19 21-2BC01 20 mm x mm, 2 mm x mm 00 3/0-0 MCM 8US19 41-2AA01 30 mm x mm 0 300-0 MCM 8US19 41-2AA02 Terminal covers for circular conductors (mounts to busbars) For terminals up to 20 MCM 200 mm long, 84 mm wide For terminals up to 0 MCM 200 mm long, 270 mm wide 8US19 22-1GA00 For terminals up to 0 MCM 200 mm long, 13 mm wide Mounting Rail 8US19 22-1GA00 8US19 22-1GA02 FBC13 Accessories for busbar adapters and device holders Mounting rail (3 mm) - plastic 4 mm n/a 8US1998-7CA1 complete with mounting screws mm n/a 8US1998-7CA16 70 mm n/a 8US1998-4AA00 90 mm n/a 8US1998-7CA08 1 mm n/a 8US1998-7CA Connection holder - n/a 8US1998-1DA00 20 (for vertical bubar assembly) fixes the MSP to the mounting rail 3) (for SIRIUS sizes S00/S0) Screw holder - n/a 8US1998-1CA00 20 for supplementary screw fixing of the feeder 8US1998-1BA00 (for SIRIUS sizes S00/S0) 0 0 0 0 1 1 1 1 6 3 0 0 0 0 1 1 1 1 6 3 1 FBC20 Spacer - n/a 8US1998-1BA00 fixes the busbar adapter to the device holder - n/a 8US1998-1BA01 (for SIRIUS sizes S00/S0) Connection wedges - n/a FBC20 20 for mechanical linking of adapters and switching device holders (2 units required per combination) 0 1 Load Side Terminal Outgoing terminal rail for busbar adapters Plug-type terminal (complete with supporting element for attaching to busbar adapter and switching device holder. Spring loaded terminals.) 3 x 14 AWG (400 V) and 4 x 16AWG (20 V) 91 mm 4 mm n/ a 8US1998-8AM07 7 x 14 AWG (400 V) 91 mm 4 mm n/a 8US1998-8AA Accessories for busbar adapters and device holders Side module for busbar adapter expansion For adapters w/182 mm 182 mm mm n/a 8US1998-2BM00 Side module for busbar adapter expansion For adapters w/200 mm 200 mm 9 mm n/a 8US1998-2BJ 8US1998-2BM00 1) UL08A labeled panels require the use of components that meet the creepage and air distances of 1 air clearance and 2 creepage distance. N/A = not applicable for given item. 2) Terminals must be manually spaced on the busbar to comply with UL08A distances of 1 air clearance and 2 creepage distance. 3) Cannot be used on Twin T (TT) profile up to 1400 A. Product Category IEC Siemens Industry, Inc. Industrial Control Product Catalog 2017 /9

mm system Dimension drawings FBB36/FBB Copper Busbar 8US19 23-3UA01 8US19 43-3AA00 31 2 6 112 40 40 A 0.187 () L1 7 L1 0.7 (20) L 2 18 166 0 L2 120 209 Dimension A FBB36 36 (914) FBB (124) NSE0_0208 L3 2 0173 1 NSE0_02071 L3 31 40 123 Copper Busbar/TT profile, 8US19 48-2AA00 30 6 40 8US19 22-1AC00 with 8US19 23-3UA01 8US19 22-1AC00 with 8US19 23-3AA01 Support for blanking covers, 8US1922-2EA00 32 200 NSE0_02070 NSE0_02073 9 49,4 62, 8US19 22-2AA00 8US19 22-2BA00 8US19 23-1AA01,2,2 Blanking cover, 8US1922-2EB00 NSE0_02072 30, NSE0_00720 30, NSE0_00721 Length 00 mm Length 00 mm 8US19 22-2DA00 34 31 1, 71 78 200 NSE0_017 40 62, / Siemens Industry, Inc. Industrial Control Product Catalog 2017

mm system Dimension drawings Infeed, 8US19 21-1BA00 Infeed, 8US19 41-2AA03 0 2 28 200 94 4 NSE0_020 32 88 194 NSE0_02074 14 184 21 72 0 36 94 96 16 Infeed, 8US19 21-1AA00 Infeed, 8US19 41-2AA04 0 28,7 200 81 NSE0_0209 32 88 194 NSE0_0203 1 184 8,8 72 0,2 28 88 148 Infeed SH338 FBT0F (supplied with cover) FBT0F Cover 34 194 200 166 146 I2_13999a 20 28 32 180 Siemens Industry, Inc. Industrial Control Product Catalog 2017 /11

mm system Dimension drawings Busbar device adapter, 8US12 0-AM00 Busbar device adapter, 8US12 -AP00 NSE0_0201 20 3,4 47,4 3,8 182 242 6 1,7 23,7 Busbar device adapter, 8US12 61-FM08 Busbar device adapter, 8US12 11-4TR00 12 68 148 182 20 6 NSE0_02062 214 200 164 40 Ø3,4 47,4 4 2,9 23,7,2 8, Ø2, 41 72 26, 4, NSE0_02068 148 12 20 3 Ø3,4 242 182 6 Busbar device adapter, 8US12 1-DM07 Busbar device adapter, 8US12 61-FP08 170 20 182 48 NSE0_02063 6 Ø3, 29, 36 4 2, 23,7,2 8, NSE0_02061 47,4 4 23,7,2 8, /12 Siemens Industry, Inc. Industrial Control Product Catalog 2017

mm system Dimension drawings Busbar device adapter, 8US12 1-CM47 Busbar device adapter, 8US12 13-4AQ01 NSE0_02069 114, 114, 190 31, 38,8 23 3 NSE0_02066 8US19 98-2BM00 Busbar device adapter, 8US12 13-4AQ03 3, 26,8 23 64 14 3 32 42 182 14 3 131, 131, 190 NSE0_0206 Busbar device adapter, 8US12 13-4AH00 247, 270 296 6 24 4 140 NSE0_02067 Siemens Industry, Inc. Industrial Control Product Catalog 2017 /13

mm system Dimension drawings 8US1941-2AA01 Type a b c d e f Max tighening torque 1 mm 8US1921-2AA0. 8US1921-2AB0. 8US1921-2AC0. 8US1921-2AD0. mm 8US1921-2BA0. 8US1921-2BB0. 8US1921-2BC0. 8US1921-2BD0. 7.. 17 14. 7.. 17 14. 11. 1. 23. 20. 11. 1. 23. 20. 22. 29 36 32 22. 29 36 32 2 3 42 2 3 42 12 12 12 12 4 Nm 6 Nm 1 Nm Nm 4 Nm 6 Nm 1 Nm Nm 43 8, 40 max. 98 8US1921-2A / -2B 8US1941-2AA02 1 max. 84 max. 86 42 43 31 38 FBC13 8US1922-1GA00 189 194 200 84 32 3 8US19 22-1GA02 /14 Siemens Industry, Inc. Industrial Control Product Catalog 2017

mm system Dimension drawings 8US19 98-1CA00 8US19 98-1DA00 8US19 98-4AA00 8US19 98-7CA08 27 3 29 7 74 90 29 9 14 NSE0_0199 8US19 98-7CA 8US19 98-7CA1 8US19 98-7CA16 8US19 98-1BA00 8US19 98-8AM07 8US19 98-8AA 8US19 98-1CA00 8US19 98-1DA00 Siemens Industry, Inc. Industrial Control Product Catalog 2017 /1

SIRIUS 3RA Fast Bus Combination Starters and Group Installation Assemblies General data Order No. scheme Digit of the Order No. 1st - 3rd 4th th 6th 7th 8th 9th th 11th 12th 13th 14th 1th 16th @@@ @ @ @ 0 @ @ @ @ @ @ @ @ @ SIRIUS starters 3 R A SIRIUS 2nd generation 2 Type of starter (direct-on-line starter = 1, @ reversing starter = 2) Size (S00 = 1, S0 = 2) @ Setting range for overload release @ @ Design type and connection method @ Rated power at 4 V AC @ @ Integrated auxiliary switches of the contactor @ Operating range / solenoid coil circuit (contactor) @ Rated control supply voltage (contactor) @ @ Example 3 R A 2 1 1 0 0 B A 1 1 A K 6 Note: The Order No. scheme is presented here merely for information purposes and for better understanding of the logic behind the order numbers. For your orders, please use the order numbers quote in the catalog in the Selection and ordering data. Technical specifications Direct-on-line starters/ reversing starters Mounting dimensions Direct-on-line starters 3RA21. H W D Reversing starters 3RA22. Size Connection methods Mounting Control voltage Width W Height H Depth D S00 3RA21 1. S0 3RA21 2. S00 3RA22 1. S0 3RA22 2. mm mm mm Screw terminals Standard mounting rails AC/DC 4 167 97 Busbar adapters AC/DC 4 200 1 Spring-type terminals Standard mounting rails AC/DC 4 198 97 Busbar adapters AC/DC 4 2 1 Screw terminals Standard mounting rails AC 4 193 97 DC 4 193 7 Busbar adapters AC 4 2 1 DC 4 2 16 Spring-type terminals Standard mounting rails AC/DC 4 243 7 Busbar adapters AC/DC 4 2 16 Screw terminals Standard mounting rails AC/DC 90 170 97 Busbar adapters AC/DC 90 200 1 Spring-type terminals Standard mounting rails AC/DC 90 204 97 Busbar adapters AC/DC 90 2 1 Screw terminals Standard mounting rail AC 90 26 120.3 adapters DC 90 26 130 Busbar adapters AC 90 2 1 DC 90 2 16 Spring-type terminals Standard mounting rail AC/DC 90 270 131 adapters Busbar adapters AC/DC 90 2 16 Type 3RA2. 1 3RA2. 2 Size S00 S0 Number of poles 3 3 Mechanics and environment Permissible ambient temperature During operation C -20... + Storage and transport C -... +80 Weight kg 0.6... 1. 0.8... 2.3 Permissible mounting positions 22 22 9 9 3 9 Shock resistance (sine-wave pulse) Important: Acc. to DIN 432 start command "I" at the right or top Acc. to IEC 086 Part 2-27 g Up to 6 Up to 6 Degree of protection Acc. to IEC 947-1 IP20 /16 Siemens Industry, Inc. Industrial Control Product Catalog 2017

Combination Starters & Starters for Group Installation SIRIUS 3RA Motor Starters General data Direct-on-line starting For mm busbar systems Sizes S00 and S0 mm busbar adapter for screw terminals 8US12 1-DS for S00 8US12 1-NT for S0 mm busbar adapter for spring-type terminals 8US12 1-DT11 for S00 8US12 1-NT11 for S0 Motor starter protector Size S00/S0 Screw terminals Motor starter protector Size S00/S0 Spring-type terminals Link module 3RA19 21-1DA00 for S00 3RA29 21-1AA00 for S0, AC contactor 3RA29 21-1BA00 for S0, DC contactor Link module 3RA29 11-2AA00 for S00 1) 3RA29 21-2AA00 for S0 Contactor Size S00/S0 Screw terminals Left: 3RA21 motor starter for direct-on-line starting with busbar adapters with screw connection Contactor Size S00/S0 Spring-type terminals 1) Additional 3RA29 11-1CA00 spacer for height compensation on AC contactors size S0 with spring-type terminals. NSB0_02091a Right: 3RA21 motor starter for direct-on-line starting with busbar adapters with spring-type connection 3RV203 with 3RT203 3RV204 with 3RT204 MSP 3RV203 Adapter Shoe 8US1261-FP08 MSP 3RV204 Adapter Shoe 8US1211-4TR00 Link Module 3RA2931-1A AC/DC Link Module 3RA1941-1A AC/DC Contactor 3RT203 Contactor 3RT204 Bracket FBS0070B Siemens Industry, Inc. Industrial Control Product Catalog 2017 /17

SIRIUS 3RA Fast Bus Combination Starters and Group Installation Assemblies Selection Reversing duty For mm busbar systems Sizes S00 and S0 RS assembly kit for reversing duty and busbar mounting Screw connection: 3RA29 13-1DB1 for S00 3RA29 23-1DB1 for S0 For spring-type connection: 3RA29 13-1DB2 for S00 3RA29 23-1DB2 for S01) Comprising: 1 wiring kit 1 busbar adapter 1 device holder 2 connecting wedges 1) Also includes 3RA29 11-1CA00 spacer for height compensation on AC contactors size S0 with spring-type terminals. mm busbar adapter For screw terminals: 8US12 1-DS for S00 8US12 1-NT for S0 For spring-type terminals: 8US12 1-DT11 for S00 8US12 1-NT11 for S0 Motor starter protector Size S00/S0 Screw terminals/ spring-type terminals 2 connecting wedges 8US19 98-1AA00 Link module For screw terminals: 3RA19 21-1DA00 for S00 3RA29 21-1AA00 for S0, AC contactor 3RA29 21-1BA00 for S0, DC contactor For spring-type terminals: 3RA29 11-2AA00 for S00 2) 3RA29 21-2AA00 for S0 1 mm device holder 8US12 1-AS 4 3 NSB0_02094b 2 contactors Size S00/S0 Screw terminals/ spring-type terminals 2) Additional 3RA29 11-1CA00 spacer for height compensation on AC contactors size S0 with spring-type terminals. 2 Wiring kit Screw connection: 3RA29 13-2AA1 for S00 3RA29 23-2AA1 for S0 Spring-type connection: 3RA29 13-2AA2 for S00 3RA29 23-2AA2 for S0 1 Upper wiring module 2 Lower wiring module 3 2 connecting clips 4 Mechanical interlock (can be removed if necessary) 3RA22 motor starter for reversing duty and mm standard mounting rail in size S00/S0 (the version with screw connection is shown in the picture) /18 Siemens Industry, Inc. Industrial Control Product Catalog 2017

SIRIUS 3RA Fast Bus Combination Starters and Group Installation Assemblies Selection Required Components for Fast Bus Mounting 3RV203 with Reversing 3RT203 a Link Module 3RA2931-1A AC/DC b Mechanical Interlock 3RA2934-2B c Fast Clips FBC20 MSP 3RV203 Contactor Support 8US12-AP00 (without DIN rail) and with 8US1998-2BM00 Adapter Shoe 8US1261-FP08 2 Contactors 3RT203 3RV204 with Reversing 3RT204 3RA2933-2AA2 Wiring Kit au Upper Wiring Module bu Lower Wiring module a Link Module 3RA1941-1A AC/DC b Mechanical Interlock 3RA2934-2B Adapter Shoe 8US1211-4TR00 MSP 3RV204 a 3RA2943-2AA1 Wiring Kit au Upper Wiring Module bu Lower Wiring Module au b 2 Contactors 3RT204 2 Brackets FBS0070B bu Siemens Industry, Inc. Industrial Control Product Catalog 2017 /19

SIRIUS 3RA Fast Bus Combination Starters and Group Installation Assemblies Dimensions Dimensions, 3RV201 with 3RT201 3RA21 Fast Bus Non-reversing 3RA22 Fast Bus Reversing 4 14.9 4 96.9 200 169.9 49 1) Lockable in OFF position. Padlock diameter mm. 2) When a front auxiliary is installed on the contactor, add 44 mm to the depth of the contactor. Dimensions, 3RV202 with 3RT201 3RA2120 Fast Bus Non-reversing 3RA2220 Fast Bus Reversing 4 97 96.9 193.4 49 1) Lockable in OFF position. Padlock diameter mm. 2) When a front mount auxiliary is installed on the contactor, add 44 mm to the depth of the contactor. All dimensions shown in millimeters. For reference purposes only. Not to be used for design or construction purposes. /20 Siemens Industry, Inc. Industrial Control Product Catalog 2017

SIRIUS 3RA Fast Bus Combination Starters and Group Installation Assemblies Dimensions 3RV203 with 3RT203 3RA2130 Fast Bus Non-reversing 3RA2230 Fast Bus Reversing 34 1) 1) SIEMENS 2) 3 14 SIEMENS 2) 29 309 29 309 SIEMENS 3) SIEMENS SIEMENS NSK-8174 7 18 17 18 28 68 9 142 DC 17 176 NSK-817 17. 120 Lateral clearance to grounded components minimum 6 mm. 1) Arcing space 2) Lockable in OFF position with padlock diameter mm. 3) When a front mount auxiliary is installed on the contactor, add 49 mm to the depth of the contactor. All dimensions shown in millimeters. For reference purposes only. Not to be used for design or construction purposes. Siemens Industry, Inc. Industrial Control Product Catalog 2017 /21

SIRIUS 3RA Fast Bus Combination Starters and Group Installation Assemblies Dimensions 3RV204 with 3RT204 Lateral clearance to grounded components minimum 6 mm. 1) Arcing space 2) Lockable in OFF position with padlock diameter mm. 3) When a front mount auxiliary is installed on the contactor, add 49 mm to the depth of the contactor. All dimensions shown in millimeters. For reference purposes only. Not to be used for design or construction purposes. /22 Siemens Industry, Inc. Industrial Control Product Catalog 2017