KATflow 150 Ad vanced Clamp-On U ltrasonic Flowmeter

Similar documents
KATflow 230 Portable Clamp-On Ultrasonic Flowmeter

THE TECHNOLOGY BEHIND THE MEASUREMENT

KATflow 200 Hand-Held Clamp-On Ultrasonic Flowmeter

Aysix 200 Hand-Held Flow Meter

Specialists in Ultrasonic Flow Measurement

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Specialists in Ultrasonic Flow Measurement

Series DMHF Heat Meter

Technical specification FLUXUS F501IP. Non-invasive ultrasonic flow measurement on buried pipes. Features. Applications

Ultra Sonic Flowmeter DATASHEET

SITRANS F flowmeters SITRANS F US. SITRANS FUS1010 Standard clamp-on. 4/270 Siemens FI Overview

Ultrasonic Heat Flow Meters

DigitalFlow GC868 Panametrics Clamp-On Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

Data sheet deltwavec-f

Series TFXB Ultra. Transit Time Ultrasonic Flow Meter, Clamp-on, Liquid, Single-Channel

Technical specification FLUXUS F501. Ultrasonic measurement of water flow

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

Flow Measurement SITRANS F US Clamp-on

Measurement. SITRANS F US Inline. Transmitter FUS080/FUE080 4/221

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100-NG SERIES

UTM10 Series Ultrasonic Transit-time Flowmeters

Clamp-On Transit Time Ultrasonic Flow Meters

SITRANS F flowmeters SITRANS F US

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

DMTFP Portable Ultrasonic Flow Meters

Series DMTFB wall-mount Clamp-on Transit Time Ultrasonic Flow Meters provide abundant capabilities for accurate liquid flow measurement from

MID approval no. DE-08-MI004-PTB004 Date of release

Flow Measurement SITRANS F US Clamp-on

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

Sono-Trak Transit Time Clamp-on Ultrasonic Flow Meter

SITRANS F C. Transmitter MASS 6000 Ex d compact/remote 3/195

ULTRASONIC TRANSIT TIME FLOWMETERS TTFM100 SERIES

SITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview

OPTISONIC 6400 Technical Datasheet

imag 4700 Series FLANGED MAGMETER

imag 4700 Series FLANGED MAGMETER

SITRANS L Level instruments

SITRANS F flowmeters SITRANS F US. SITRANS FUH1010 Oil clamp-on. 4/294 Siemens FI

TRICOR Series TCM Coriolis Mass Flow Meters

Flow Measurement SITRANS F US Clamp-on

Flow Measurement SITRANS F C

DIN-Rail Mounted Ultrasonic Flow Meter

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Ultrasonic Flow Meter Brochure

Level gauges Series LS Level indicator, switch and transmitter for liquids

EQUITY SERVICES & SOLUTIONS CO.,LTD. cono Flow

Operating & ATEX/IECEx Safety Instructions. KATflow 170 Ultrasonic Flowmeter. Aluminium and stainless steel enclosures (Aluminium illustrated above)

DCT7088 Portable Digital Correlation Transit Time Flowmeter

CALEC energy master The benchmark in energy measurement

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

... f l o w measurement & control...

Flow Measurement. SITRANS F US Clamp-on. SITRANS FUG1010 (Gas) 4/336 Siemens FI Overview

MAG. ECO FLO imag Series NSF FEATURES

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Level and Flow Measurement. Flow Pulse

RHE21. Exd / Exd(e) Extreme Environment Multifunction Coriolis Flow Transmitter

C-Flow Coriolis Mass Flow Meter

FEATURES Easy setup Minimal straight pipe Mounted or remote rate & total Tamper-evident seal NSF-61 approved IP68 rated

Clamp-On Ultrasonic Flow- and Energy Meter For Liquids

OPERATING INSTRUCTIONS

OPTIFLEX 1100 C Technical Datasheet

Continuous level measurement Radar transmitters

ECHO Process Instrumentation, Inc. Modbus RS485 Module. Operating Instructions. Version 1.0 June 2010

imag-series Flanged Magmeter

AG3000 SERIES FLANGED MAGMETER

RHE27. Rack/Panel Mount Multifunction Coriolis Flow Transmitter

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

Flow Measurement SITRANS F C

AG3000 SERIES FLANGED MAGMETER

LiquiDens. SensoTech. Process density meter for liquids Product description

Vane wheel probe BFA25 for flow measurement of gases and liquids with integrated, configurable transducer UFA in Ex-d housing

Variable Area Flowmeter DATASHEET

FH8500. Metering Solution for Custody Transfer Applications. One Step Ahead in Ultrasonic Flowmetering. Main Applications

EE310. High-End Humidity and Temperature Transmitter for Demanding Process Control. Typical applications. Features EE310 EE310

INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

Level Measurement Continuous level measurement - Ultrasonic transmitters

Hydrostatic filling level sensor HFB C4 / R / MD

SITRANS F flowmeters. SITRANS F C Transmitter MASS 6000 for 19" insert/19" wall mounting. 4/134 Siemens FI

US300PM Ultrasonic Flowmeter

Level Measurement Continuous level measurement - Ultrasonic controllers

Level and Flow Measurement. Flow Pulse

Flow Measurement SITRANS F C

TransPort PT878. Panametrics Portable Liquid Ultrasonic Flowmeter. GE Measurement & Control. Applications. Features

PTU300 Combined Pressure, Humidity and Temperature Transmitter

FTM84/85 Feature Application. Temperature & Humidity / Flow Measuring Specialist

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

MULTICHANNEL DATA RECORDERS

SONICMAX UL3400C. 3-BEAM Compact Ultrasonic Flowmeter OUTLINE FEATURES STANDARD SPECIFICATIONS

Advantages high measuring dynamics Nv (up to 1 : 1000) measuring range from 0.2 m/s. low measuring uncertainty, even at lowest flow velocities

TransPort PT878 Panametrics Portable Ultrasonic Liquid Flowmeter. GE Sensing. Applications. Features

MMT330 Series Moisture and Temperature Transmitters for Oil

Flow VA 500/

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

Level Measurement Continuous level measurement Ultrasonic controllers

CONVERTER MC608 A/B/R/P/I. The Hybrid electronic converter for all applications DS300-1-USA

Transcription:

Ad vanced Clamp-On U ltrasonic Flowmeter FAST. FLEXIBLE. FUNCTIONAL. The KATflow 150 is the premier product for flexibility and performance, providing the user with a comprehensive specification and a list of configuration options. The practical modular design and the wide variety of different transducer types available ensure this instrument is suitable for everything from simple water flow measurements to energy flow monitoring and automated process control.

Katron ic Your Solution Starts With Our Product THE TECHNOLOGY BEHIND THE MEASUREMENT The KATflow non-invasive flowmeters work on the transit time ultrasonic principle. This involves sending and receiving ultrasonic pulses from a pair of sensors and examining the time difference in the signal. Katronic uses clamp-on transducers that are mounted externally on the surface of the pipe and which generate pulses that pass through the pipe wall. The flowing liquid within causes time differences in the ultrasonic signals, which are then evaluated by the flowmeter to produce an accurate flow measurement. The key principle of the method applied is that sound waves travelling with the flow will move faster than those travelling against it. The difference in the transit time of these signals is proportional to the flow velocity of the liquid and consequently the flow rate. Since elements such as flow profile, type of liquid and pipe material will have an effect on the measurement, the flowmeter compensates for and adapts to changes in the medium in order to provide reliable results. The instruments can be used in a variety of locations, from measurements on submarines to installations on systems destined for use in space, and on process fluids as different as purified water in the pharmaceutical sector and toxic chemical effluent. The flowmeters will operate on various pipe materials and diameters over a range of 10 mm to 6,500 mm. Sensors a and b work alternately to send and receive ultrasonic pulses. The sound waves ab travelling with the flow move faster than those travelling against it ba. www.katronic.co.u k 2/15

Fixed I nstallation - C C 30 + 250 SPECIFICATION Pipe diameter range 10 mm to 6,500 mm Temperature range for sensors -30 C to +250 C (-22 F to +482 F), higher temperatures available on request Lockable and sturdy IP 66 polycarbonate flowmeter enclosure Selectable three-line LCD display and full keypad Up to ten input or output slots available Measurement of two flows simultaneously FEATU RES Dual flow monitoring with sum, average, difference and maximum calculations Process output options including current, open-collector, relay Communication options RS 485, Modbus RTU, Profibus PA and HART* compatible output Current inputs for temperature, pressure and density compensation Large data logger and software for sampling and data transfer Optional heat quantity (thermal energy) measurement functionality ACCESSORI ES PT100 transducers or analogue temperature inputs for heat quantity measurement and temperature compensation Additional secondary enclosure for ATEX applications Optional sound velocity output function KATdata+ Software for data evaluation APPLICATIONS Heating, Ventilation and Air Conditioning (HVAC) measurements Large pipe measurement with two sensor pairs in X configuration Product recognition and interface detection systems ATEX measurements with Ex-certified transducers Effluent and wastewater measurements Automated process control www.katronic.co.uk 3/15

FLOWM ETER Performance Measurement principle Flow velocity range Resolution Repeatability Accuracy Ultrasonic transit-time difference 0.01... 25 m/s 0.25 mm/s 0.15 % of measured value, ±0.015 m/s Volume flow: ±1... 3 % of measured value depending on application ±0.5 % of measured value with process calibration Flow velocity (mean): ±0.5 % of measured value Turn down ratio Measurement rate Response time Damping of displayed value Gaseous and solid content of liquid media 1/100 (equivalent to 0.25... 25 m/s) 1 Hz (standard) 1 s (standard), 90 ms (optional) 0... 99 s (selectable by user) < 10 % of volume Images KATflow 150 (dimensions in mm) www.katronic.co.u k 4/15

General Enclosure type Wall mounted Degree of protection IP 66 according to EN 60529 Operating temperature Housing material -10... +60 C (+14... +140 F) Polycarbonate (UL94 V-0) Measurement channels 1 or 2 Calculation functions Power supply Display Dimensions Weight Power consumption Operating languages Average, difference, sum, maximum (dual-channel use only) 100... 240 V AC, 50/60 Hz 9... 36 V DC Special solutions (e.g. solar panel, battery) on request LCD graphic display, 128 x 64 dots, backlit 237 (h) x 258 (w) x 146 (d) mm Approx. 2,3 kg < 10 W English, French, German, Dutch, Spanish, Italian, Russian, Czech, Turkish, Romanian (others on request) Abbildungen Images KATflow 150 in operation KATflow 150 with transducer pair www.katronic.co.u k 5/15

Communication Type Transmitted data RS 232, USB cable (optional), RS 485 (optional), Modbus RTU (optional), HART* compatible (optional), Profibus PA (optional) Measured and totalised value, parameter set and configuration, logged data Internal data logger Storage capacity Approx. 30,000 measurements (each comprising up to 10 selectable measurement units), logger size 5 MB Approx. 100,000 measurements (each comprising up to 10 selectable measurement units), logger size 16 MB Logged data All measured and totalised values, parameter sets KATdata+ software Functionality Download of measured values/parameter sets, graphical presentation, list format, export to third party software, online transfer of measured data Operating systems Windows 8, 7, Vista, XP, NT, 2000 Linux Quantity and units of measurement Volumetric flow rate Flow velocity Mass flow rate Volume Mass Heat flow Heat quantity Temperature m 3 /h, m 3 /min, m 3 /s, l/h, l/min, l/s USgal/h (US gallons per hour), USgal/min, USgal/s bbl/d (barrels per day), bbl/h, bbl/min m/s, ft/s, inch/s g/s, t/h, kg/h, kg/min m 3, l, gal (US gallons), bbl g, kg, t W, kw, MW (with heat quantity measurement option) J, kj, kw/h (with heat quantity measurement option) C (with heat quantity measurement option) www.katronic.co.u k 6/15

Process inputs (galvanically isolated) Temperature PT100 (clamp-on sensors), three- or four-wire circuit, measurement range: -30... +250 C (-22... +482 F), resolution: 0.1 K, accuracy: ±0.2 K Current 0/4... 20 ma active or 0/4... 20 ma passive, U = 30 V, R i = 50 Ω, accuracy: 0.1 % of measured value Process outputs (galvanically isolated) Current Digital open-collector Digital relay Voltage Frequency HART* compatible 0/4... 20 ma active/passive (R Load < 500 Ω), 16 bit resolution, U = 30 V, accuracy: 0.1 % Value: 0.01... 1000/unit, width: 1... 990 ms, U = 24 V, I max = 4 ma 2 x Form A SPST (NO and NC), U = 48 V, I max = 250 ma 0... 10 V, R Load = 1000 Ω 2 Hz... 10 khz, 24 V/4 ma 0/4... 20 ma, 24 V DC, R GND = 220 Ω Abbildungen KATflow 150 as heatmeter KATflow 150 with open enclosure www.katronic.co.u k 7/15

HAZARDOUS AREA ENCLOSURE General Enclosure type Wall mounted (additional to KATflow 150 flowmeter) Degree of protection IP 66 according to EN 60529 Operating temperature Housing material Finish Dimensions Weight Ex-certification code -20... +40 C (-4... +104 F) Grade LM6 cast alloy RAL 7035 epoxy powder coated 358 (h) x 278 (w) x 218 (d) mm Approx. 20.0 kg (with KATflow 150 flowmeter) II 2G/D Ex d IIB T4 - T6 IP67 Ex-certification number CESI 01 ATEX 063 HAZARDOUS AREA TRANSDUCERS K1Ex, K4Ex Pipe diameter range Dimensions of sensor heads Material of sensor heads Material of cable conduits Temperature range Standard cable length 10... 250 mm for type K4Ex 50... 3,000 mm for type K1Ex 60 (h) x 30 (w) x 34 (d) mm Stainless steel PTFE -50... +115 C (-58... +239 F) 5.0 m Degree of protection IP 68 according to EN 60529 Ex-certification code Ex-certification number Ex-protection method Note II 2G Ex mb IIC T4 - T6 X II 2D Ex mbd 21 IP68 T80 C - T120 C X TRAC 09 ATEX 21226 X Encapsulation (m), ignition source control (b) The transducers are approved for use in hazardous areas classified as Ex-Zone 1 and 2. They are connected to the flowmeter via extension cables and Ex-approved junction boxes. The flowmeter can be installed in a safe area or, if equipped with the additional Ex-enclosure, together with the transducers in a hazardous environment. www.katronic.co.u k 8/15

TRAN SDU CERS K1L, K1N, K1E Pipe diameter range Dimensions of sensor heads Material of sensor heads 50... 3,000 mm for type K1N/E 50... 6,500 mm for type K1L 60 (h) x 30 (w) x 34 (d) mm Stainless steel Material of cable conduits Type K1L: PVC Type K1N/E: Stainless steel Temperature range Type K1L: -30... +80 C (-22... +176 F) Type K1N: -30... +130 C (-22... +266 F) Type K1E: -30... +250 C (-22... +482 F) (for short periods up to +300 C (+572 F)) Degree of protection IP 66 according to EN 60529 (IP 67 and IP 68 on request) Standard cable lengths Type K1L: 5.0 m Type K1N/E: 4.0 m Images K1L transducers K1L transducers K1N /E transducers www.katronic.co.u k 9/15

K4L, K4N, K4E Pipe diameter range 10... 250 mm for type K4N/E 10... 250 mm for type K4L Dimensions of sensor heads Material of sensor heads 43 (h) x 18 (w) x 22 (d) mm Stainless steel Material of cable conduits Type K4L: PVC Type K4N/E: Stainless steel Temperature range Type K4L: -30... +80 C (-22... +176 F) Type K4N: -30... +130 C (-22... +266 F) Type K4E: -30... +250 C (-22... +482 F) (for short periods up to +300 C (+572 F)) Degree of protection IP 66 according to EN 60529 (IP 67 and IP 68 on request) Standard cable lengths Type K4L: 5.0 m Type K4N/E: 2.5 m Images K4N /E transducers K4L transducers K4N /E transducers www.katronic.co.u k 10/15

Extension cable Available lengths Cable type Material cable jacket Operating temperature Minimum bend radius 5.0... 100 m Coaxial TPE -40... +80 C (-40... +176 F) 67 mm Cable connection Connection types Junction box, Amphenol connectors (for transducer type N) Termination into transmitter SMB connector (SubMiniature version B) Direct cable connection (terminal block) www.katronic.co.u k 11/15

TRANSDUCER MOUNTING ACCESSORIES General Diameter range and mounting types Clamping set (metal strap with screw), stainless steel: DN 10... 40 Metallic straps and clamps: DN 15... 310 Metallic straps and clamps: DN 25... 3,000 Metallic mounting rail and straps (available on request): DN 50... 250 or DN 50... 3,000 Mounting fixture for flexible hoses Custom made mounting bracket, stainless steel (available on request) Images Metallic mounting rail with transducers Example of mounting fixture for flexible hoses www.katronic.co.u k 12/15

PT100 CLAMP-ON SENSORS General Type PT100 (clamp-on sensors) Measurement range -30... +250 C (-22... +482 F) Circuits 4-wire Accuracy T ±(0.15 C + 2 x 10-3 x T [ C]), class A Accuracy ΔT 0.1 K (3 K < ΔT < 6 K), corresponding to EN 1434-1 Response time 50 s Dimensions of sensor heads 20 (h) x 15 (w) x 15 (d) mm Material of sensor heads Aluminium Material of cable jacket PTFE Cable length 3.0 m Images PT100 transducer PT100 transducer fixed to pipe PT100 with wired cable connection www.katronic.co.u k 13/15

Configu ration Cod e FLOWMETER AND ACCESSORIES KF 150 Ultrasonic flowmeter KATflow 150, serial interface RS 232, operating instructions Number of measurement channels 1 1 measurement channel 2 2 measurement channels 1) Internal code 03 Internal code Power supply 1 100 240 V AC, 50/60 Hz 2 9 36 V DC Enclosure type 1 Polycarbonate (UL94 V-0), wall mounted, IP 66 2 Hazardous area enclosure, powder-coated LM6 cast alloy, IP 66 (II 2G/D Ex d IIB T4 - T6 IP67) Communication 0 Without 1 RS 485 serial interface 2 Modbus RTU protocol 2) Process inputs/outputs (select a maximum of 8 slots) N Without C Current output, 0/4... 20 ma, active (source) P Current output, 0/4... 20 ma, passive (sink) D Digital output, open-collector R Digital output, relay H HART* compatible output, 0/4... 20 ma 2) V Voltage output, 0... 10 V F Frequency output, 2 Hz... 10 khz A 1 x PT100 input for temperature compensation (select TC function) 3) AA 2 x PT100 input for 1-channel heat quantity measurement (select HQM option no. 2) 4) AAAA 4 x PT100 input for 2-channel heat quantity measurement (select HQM option no. 3) 4) B Current input, 0/4... 20 ma, active or passive Internal data logger 0 Without 1 30,000 measurements 2 100,000 measurements Temperature compensation (TC)/Heat quantity measurement (HQM) 0 Without 1 With TC incl. 1 x PT100 sensor, 3 m cable 3) 2 With 1-channel HQM incl. 2 x PT100 sensor, 3 m cable 4) 3 With 2-channel HQM incl. 4 x PT100 sensor, 3 m cable 4) Z Special (please consult factory) Sound velocity output (SVO) 5) 0 Without 1 With SVO PT100 cable extension 0 Without PTJ With 1 x junction box for PT100 sensor 2PTJ With 2 x junction box for PT100 sensors 3PTJ With 3 x junction box for PT100 sensors 4PTJ With 4 x junction box for PT100 sensors PT100 extension cable (length in m) 000 Without With extension cable (specify length in m) Optional items Without (leave space blank) Ex Suitable for connection with Ex-transducers SW KATdata+ download software and RS 232 cable SU KATdata+ download software and USB cable KF 100-2 - 03-1 - 1-0 - CDR - 0-0 - 0-0 - 000 / (example configuration) The configuration is customised by choosing from the above-listed options and is expressed by the resulting code at the bottom of the table. 1) For simultaneous measurement on two separate pipes or for measurement on one single pipe in a two-path sensor mounting configuration. 2) Modbus and HART* compatible outputs can not be used in conjunction with other output options. Please consult factory for more information. 3) For temperature compensation in cases of significant changes in medium temperature during measurement. 4) For contactless measurement of thermal energy consumption (for one circuit or two circuits). 5) For contactless product recognition and interface detection. www.katronic.co.u k 14/15

Configu ration Cod e TRANSDUCERS AND ACCESSORIES K1 K4 Z Transducer pair, pipe diameter range 50... 3,000 mm Transducer pair, pipe diameter range 10... 250 mm Special (please consult factory) Temperature range L Process temperature -30... +80 C, including acoustic coupling paste N Process temperature -30... +130 C, including acoustic coupling paste E Process temperature -30... +250 C, including acoustic coupling paste Ex Process temperature -50... +115 C, including acoustic coupling paste (II 2G Ex mb IIC T4 - T6 X) Z Special (please consult factory) Internal code 1 Internal code Degree of protection 1 IP 66 (standard) 2 IP 67 (please consult factory) 3 IP 68 (please consult factory) Transducer mounting accessories 0 Without 3 Clamping set DN 10... 40 4 Metallic straps and clamps DN 15... 310 5 Metallic straps and clamps DN 25... 3,000 7 Metallic mounting rail and straps DN 50... 250 (transducer type K4) 8 Metallic mounting rail and straps DN 50... 3,000 (transducer type K1) Stainless steel tag 0 Without 1 With stainless steel tag (please specify text to be engraved) Transducer connection type and extension cable length O Without connector or junction box (transducer type L or Ex) C000 Wired transducer connection to flowmeter D Without connector or junction box (transducer type N) C000 Direct transducer connection to flowmeter A Extension via Amphenol type connector (transducer type N) C 010 With extension cable, 10 m length C With extension cable (specify length in m) J Extension via junction box (transducer type L or N) C005 With extension cable, 5 m length C010 With extension cable, 10 m length C With extension cable (specify length in m) JX Extension via ATEX-junction box (transducer type Ex) C005 With extension cable, 5 m length C010 With extension cable, 10 m length C With extension cable (specify length in m) Optional items CA Without (leave space blank) 5-point calibration with certificate K1 L - 1-1 - 5-0 - J - C010 / (example configuration) The configuration is customised by choosing from the above-listed options and is expressed by the resulting code at the bottom of the table. Katronic Technologies Ltd. Earls Court Warwick Street Coventry CV 5 6ET United Kingdom Tel. +44 (0)2476 714 111 Fax +44 (0)2476 715 446 E-mail info@katronic.co.uk Web www.katronic.co.uk * HART is a registered trademark of the HART Communication Foundation Copyright Katronic Technologies Ltd. 2015 Subject to changes without prior notice. All rights reserved. Issue: DS_KF150_V41EN_1504 www.katronic.co.u k 15/15