LBI-38599F Maintenance Manual

Similar documents
Maintenance Manual ANALOG DELAY SHELF ASSEMBLY 19D902531G6, 7 ERICSSONZ LBI-38990A TABLE OF CONTENTS ANALOG DELAY MODULE...

ericssonz MAINTENANCE MANUAL STATION CROSS CONNECT PANEL ROA SPECIFICATIONS TABLE OF CONTENTS

TinyTrak4 v7 Hardware Manual

ericssonz LBI-38616B MAINTENANCE MANUAL FOR MTD TM SERIES AND DATA RADIO LOGIC BOARD 19D902151G3 DESCRIPTION CIRCUIT ANALYSIS TABLE OF CONTENTS

MAINTENANCE MANUAL KEYPAD/DISPLAY PANEL ASSEMBLIES 19D902913G3, G4, G10 (CONVENTIONAL) 19D902913G5, G6 (EDACS)

MAINTENANCE MANUAL RF MODULE TEST FIXTURE. ericssonz LBI-38805A GENERAL TABLE OF CONTENTS STATIC HANDLING PRECAUTIONS

INTERFACE PANEL 19D904009G1-G21

OPERATION & INSTALLATION MANUAL E-2010 CENTRAL CONTROL STATION

C-2000 Manual Addendum

DEV-1 HamStack Development Board

MODEL NC105 DIGITAL CODED SQUELCH ENCODER/DECODER INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS

LBI MAINTENANCE MANUAL DESKTOP STATION INTERCONNECT BOARD 188D5418G1 DESCRIPTION TABLE OF CONTENTS. Page

ERICSSONZ LBI-38566B MAINTENANCE MANUAL AUDIO BRIDGE MODULE 19D902458G1 TABLE OF CONTENTS

A Issue A Original. Instruction Manual. nxds Serial Comms Interface

Stalker Sports Speed Sensor User Manual

TRANSCEIVER DATA PROGRAMMER TDP-136 INSTALLATION & OPERATING INSTRUCTIONS. Document No. 00RE277 Rev. C FEB Technisonic Industries Limited

I/O232-A User s Guide

ACU-M Quick Start Guide

Analog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules

User Manual for the AN208

AUD-340 Installation Guide

I/O Interface DNA300

MPA FLASH PROGRAMMING

Dolphin 99EX. with Windows Embedded Handheld 6.5. Quick Start Guide

NTI. KEEMUX Series. KEEMUX-P2 (2-Port PS/2 KVM Switch) INSTALLATION / USER GUIDE R NETWORK TECHNOLOGIES INCORPORATED

TRBOnet Swift Agent A001

AIR PATHWAYS AP340 OWNERS MANUAL

MODEL NC400 MULTI-FUNCTION TOUCH-TONE DECODER INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS

JUMA-TRX2 serial protocol description OH2NLT

TT /12b INSTALLATION INSTRUCTIONS. Introduction

Job Aid: Connector and Cable Diagrams (Pinout Charts)

CSR Bluetooth Modules MBC05-CAR-AT

Domain 3000 Back Panel

TC1900 "QUICK TALK" RS-232 or Fiber Telephone Extender User's Manual

Installation Instructions 45MLA Controller

AUD-220 Installation Guide

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

1710/2710/4710/ /230/400/900MHz

TMR1F USER GUIDE AND EVALUATION KIT MANUAL

IT 1910i. Industrial 2D-code hand-held scanner TECHNICAL DESCRIPTION. make technical changes EN /06. We reserve the right to

SET-UP INSTRUCTIONS. How can the DB9000-TX be used as an Icecast Source Client, sending audio to DB9000-RX decoder used as an Icecast Source Server

icex-cmtm General specs and Installation guide

CF Plug-In. Evaluation Board User Guide. Bulletin Revision Date

INSTALLATION INSTRUCTIONS. Table of Contents

PROGRAMMING AND USE INSTRUCTIONS FOR THE OVATION SYSTEM

Storage/Control I/O Module

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

Wireless Transducer MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

Intech Micro 2300-A8VI analogue input station MODBUS RTU slave application supplementary manual.

2D Image Handheld Scanner

RLC-4 4 Port Communications Controller Software Version 1.30 Copyright 1995 All Rights Reserved

Professional Digital Two-Way Radio System MOTOTRBO Mobile. Radio Installation Manual

WIRELESS INTERCOM SYSTEM Service Information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

1-channel MPEG-4 Video Decoder ACD Ver Quick Installation Guide

4M06 E&M Interface Module Guide

TB8100 base station. Task Manager Programming Guide

Major BOS 2a2. Serial number 3799 or higher

Example: Enable sleep mode

LVX Control Unit. Features:

Troubleshooting Guide for Firecom Intercoms

Product type designation. General information. Supply voltage. Input current

Marshall Electronics. AR-AM4-BG Analog Audio Monitor. Operating Instructions

TRAINING GUIDE LEVEL 3 MODBUS WRITE IMPORT COMMAND

Prizm Mux Monitor (PMon) User Manual. March 13, Rev. 2.1

VM-3-SM1. Speaker Microphone with Voice Storage. Manual Revision: Covers Software Revisions: VS-1XXX:

-C5RS-LC RS232 EXTENDER

WM1030 Rev Introduction. Ultra low power DASH7 Modem. Applications. Description. 868 / 915 MHz. Features. WIZZILAB Technical datasheet 1/10

ACR8020 Hardware Manual

Axiom Manufacturing. Users Manual. for PROJECT DEVELOPMENT BOARD AXM xiom anufacturing

OPERATION MANUAL. Carbon monoxide 0 to 1000 PPM, Temp. CO METER. Model : GCO-2008

DCC-8 DIGITAL TO EIGHT CURRENT LOOP CONVERTER OPERATING MANUAL

TRBOnet Swift Agent A002

INSTRUCTION MANUAL. Card Revision: Software 2.1 Card Revision: Hardware B(2.0) DOCUMENT SES-KS-2422-E REV. 3

AUDIO D-Type Pin-outs TALKBOX INSTALLER 12 1U RACK BOX BCD 25/09/07. Broadcast Audio Custom Manufacture Design and Consultancy

NX21 USER MANUAL. Telemetry Unit. Version 1.5

1-channel MPEG-4 Video Encoder ACD-2100T. Ver User s Manual 0-0

Data sheet CPU 115 (115-6BL02)

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

LBI Mobile Communications S825 FLASH PROGRAMMING. Programming Instructions

SH1030 Rev Introduction. Ultra low power DASH7 Arduino Shield Modem. Applications. Description. 868 MHz. Features

Mate Serial Communications Guide This guide is only relevant to Mate Code Revs. of 3.30 and greater

HME# 400G520 Rev F 8/1/06 PRO850. Wireless Intercom. Operating Instructions. Base Station Version A.2.0x

Helios PD Large Display Meter Quick Start Guide

DATA CONNECT ENTERPRISE

RC1170-RC232 USER MANUAL

Leuze electronic. Dimensioned drawing. Electrical connection. Accessories

TRBOnet Swift Agent A002

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

AFO485 : FIBRE OPTIC MODEM RFO485 : FIBRE OPTIC REPEATER. USER GUIDE Doc. ref : Distribué par : Contact :

TCD channel H.264 Video Encoder Hardware User s Manual (DC 12V) Ver. 2010/10/29

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

V-9908 MESSAGE/PAGE PANEL

Dual Serial Shield User Manual

Status line The top line of the LCD display shows the basic status information of the drive.

/TLC. Additional Manual for TEX-LCD series and TEX-LIGHT series. Manufactured by

8 Channel USB to RS485/422 Converter USB-402 User s Manual Ver. 1.0 HuMANDATA LTD.

Transcription:

Maintenance Manual MASTR IIe Utility Handset

TABLE OF CONTENTS INTRODUCTION................................................... 3 DESCRIPTION.................................................... 3 Control Shelf.................................................. 3 Auxiliary Backplane (MASTR IIe)....................................... 3 Utility Handset.................................................. 4 OPERATION..................................................... 4 Power On.................................................... 4 Operating Functions............................................... 5 System Functions................................................ 5 Function Descriptions.............................................. 6 ADJUSTMENTS................................................... 8 Potentiometer Adjust Mode........................................... 8 Metering Mode................................................. 9 Channel Select Mode.............................................. 10 Remote Station Adjustments Via Modem.................................... 10 Maintenance................................................... 11 APPENDIX A..................................................... A-1 Page SPECIFICATIONS POWER SUPPLY Nominal Range CURRENT DRAIN On (rated Audio) OPERATING TEMPERATURE RANGE Nominal Operating Range Vcc VOLTAGE At 5 o C At 30 o C At 70 o C 1.5 Vdc 10 to 16 Vdc No failure or lack of function within this range. 100 ma 4 o C -30 o C to +60 o C 5.0 Vdc to 5.4 Vdc, typical 5.5 Vdc to 5.9 Vdc, typical 5.0 Vdc to 4.6 Vdc, typic This manual is published by Ericsson Inc., without any warranty. Improvements and changes to this manual necessitated by typographical errors, inaccuracies of current information, or improvements to programs and/or equipment, may be made by Ericsson Inc., at any time and without notice. Such changes will be incorportated into new editions of this manual. No part of this manual may be reproduced or transmitted in any form or by any means, electronic or mechanical, including photocopying and recording, for any purpose, without the express permission of Ericsson Inc. Copyright 1991-000 Ericsson Inc. All rights reserved.

INTRODUCTION The MASTR III/MASTR IIe Utility Handset 19A705965P1 or 19A705870P and handset cable 19D901619P are used to provide simple programming and diagnostic functions to aid the service technician when servicing the equipment. This manual may be used with all versions of software. For equipment using group 1 through 5 software, refer to Appendix 1 in the back of this manual. For MASTR III and MASTR IIe with group 6 or later software, continue on in this section. DESCRIPTION In MASTR IIe applications the auxillary backplane (B3MB1B) contains the handset interface circuitry and the handset connector. The backplane allows the service technician to do some programming and to perform various diagnostic functions using the Utility Handset. In MASTR III applications, all interface circuitry is housed in the Transmitter/Receiver shelf. The handset provides the following functions: Local Microphone and Speaker Adjustment of Digital Potentiometers Station Metering Channel Selection Function Enable/Disable CONTROL SHELF (MASTR IIe) The Control Shelf hardware includes a EEPROM containing the operating characteristics (or personality) of the Control Shelf. The contents of the EEPROM can be changed only with the use of the Utility Handset or with a personal computer. All audio input and output levels for the Control Shelf are controlled by electronic potentiometers. These potentiometers must be adjusted by the Utility Handset or by a personal computer. There are NO manual adjustments on the Control Shelf! A complete description of the Control Shelf EEPROM personality settings is contained in the programming software, TQ3353. A complete listing of all lines and signals as well as a discussion of Level Adjustments is contained in Control Shelf Maintenance Manual, LBI 38430. AUXILIARY BACKPLANE (MASTR IIe) The Auxiliary Backplane plugs into the standard MASTR IIe Backplane through a 96-pin DIN connector (see Figure 1). The backplane contains the necessary hardware to convert TTL levels of the handset to RS3 data understood by the MASTR IIe Control Module. A mounting bracket and TORX T15 screws secure the Auxiliary Backplane to the station frame. The Utility Handset cable connects to the RJ45 jack (J) on the Auxiliary Backplane board. Figure 1 - Backplane and Auxiliary Backplane Boards 3

UTILITY HANDSET In MASTR IIe applications, the Utility Handset Cable plugs into the RJ45 jack (J) on the Auxiliary Backplane board. In MASTR III applications, the Utility Handset Cable plugs into the MIC jack located in the upper right hand corner of the Transmitter/Receiver shelf. See Figure. OPERATION POWER ON While pressing either VOLUME button on the side of the handset, toggle the RESET switch on the front of the MASTR IIe Power Module. This tells the Control Module there is a handset present. NOTE The handset will not operate if there is a PC connected to the DB9 serial port of the MASTR IIe backplane or to the MASTR III T/R shelf. Successful power-up will cause the display to show: MENU On the initial handset power-up the invalid key flag may appear in the display. It should be disregarded. Pressing any key will cause it to disappear. Figure - MASTR III Control Shelf 4

OPERATING FUNCTIONS The handset operating functions are shown in Figure 3. These functions are in addition to the operating characteristics listed below: Figure 3 - Handset Operations NOTE MASTR IIe - Make sure the RF equipment has been properly aligned before making ANY adjustments to the control shelf. Local Push-to-Talk is a toggled (press On-press Off) function. When active, the handset s microphone may be used and the "IN USE" flag on the display will be illuminated. Also the Tx LED on the System Module will light if Tx is active. END Button always returns the handset to the top MENU display. CLR Button always moves the handset back one level. Volume Keys may be held continuously to change any potentiometer setting. Handset Speaker is active and may be used as an intercom speaker. Scan Active Indicator will light the ROAM light on the display when Scan is active. SYSTEM FUNCTIONS The Utility Handset may be used to toggle special functions in the station (see Figure 4). To enter the Function Select Mode from the main menu, press the FNC key. While in the various Function Modes (select/display), the handset will show FCN on the display. To clear an unwanted entry in the Function Select Mode, press CLR. Pressing CLR a second time will return the handset to "MENU" display. If an invalid function number is entered and either START or STOP is pressed, the handset will display the INVALID key flag. To make another selection from the Function Display Mode, press the CLR key. The handset will return to the Function Select Mode and display "F SEL". 5

Function Key Display Power up handset Enter function select mode Input desired function; e.g. 7 for CGD Enable To start function To stop function To return to function select mode None FNC PRS 7 The state of the control shelf after starting or stopping functions is dependent upon the function in question and external control shelf signals (e.g., keying/unkeying a local mic). Refer to the Function Description section for specific details. Select a specific function as listed in Figure 5 and enter the corresponding number. Then press the "A" key to start (activate) the function. To stop the selected function, press the "C" key. A C CLR Figure 4 - System Functions MENU F SEL F SEL 7 START 7 STOP 7 F SEL NOTE If the function was programmed to be active, starting it will have no effect. NOTE In some functions, the stop key will actually reset the station to its originally programmed state rather than stop the selected function. Consult the detailed explanations of the function to determine its actual operation. END will return the handset to the top menu, and like the CLR function, will leave the station in the condition set by the different function commands. To reset the station s programmed personality defaults, toggle the RESET switch located on the front of the Power Module. FUNCTION DESCRIPTIONS (See Figure 5) Repeat Disable Start: Disable the repeater function. NUMBER Tx Disable FUNCTION 30 Repeat Disable 3 Tx Disable 34 CG Encode Disable 36 CG Decode Disable 37 RUS Mute 38 CG Monitor 39 Remote PTT 40 Local PTT 41 External PTT 4 Morse Code 44 Battery Alarm Disable 45 Test Tone 46 System Reset 47 CCT Disable 48 RUS Disable 49 Scan Enable 50 Scan Disable 58 Main Rx Enable 59 Main Rx Disable 60 Aux Rx Enable 61 Aux Rx Disable 64 Aux Control 1 On 65 Aux Control 1 Off 71 Priority Scan Disable 75 Scan Inhibit 96 Voting Tone Enable/ Voting Tone Disable Figure 5 - Function Chart Start: Disable the transmitter. 6

CG Encode Disable Start: Disable channel guard encode. CG Decode Disable Start: Disable channel guard decode. RUS MUTE Start: Disable the main receiver. CG Monitor Start: Enable the Channel Guard monitor function. Remote PTT Start: Key remote push-to-talk. Stop: Unkey remote push-to-talk. Local PTT Start: Key local push-to-talk. Stop: Unkey local push-to-talk. External PTT Start: Key external push-to-talk. Stop: Unkey external push-to-talk. Morse Code Start: Send Morse code ID if one is programmed. Stop: Disable Morse code ID function. Comments: If no ID is present, START will have no effect. If STOP is selected while station is transmitting ID, ID will be interrupted and terminated. Battery Alarm Disable Start: Disable battery Alarm Tone. Test Tone Start: Begin sending test tone. Stop: Stop sending test tone. Comment: The test tone frequency is 1000 Hertz. Soft Boot Start: Toggles software reset. Stop: No function. Carrier Control Timer Disable Start: Disable the carrier control timer. RUS Disable Start: Enable Receiver Unsquelched Push to Talk. Scan Enable Start: Enable SCAN. Stop: Restore original EEPROM setting. Scan Disable Start: Disable SCAN. Stop: Restore original EEPROM setting. Main Rx Enable Start: Enable the main receiver. Main Rx Disable Start: Disable the main receiver. Aux Rx Enable Start: Enable the auxiliary receiver and toggle Aux Rx Mute. Stop: No function. Aux Rx Disable Start: Disable the auxiliary receiver and toggle Aux Rx Mute. Stop: No function. Aux Control 1 On Start: Activate Auxiliary 1 output. Aux Control 1 Off Start: Deactivate Auxiliary 1 output. Priority Scan Disable Start: Disable Priority SCAN. Stop: Restore EEPROM setting of Priority SCAN Enable. 7

Scan Inhibit Start: Suspend scan operation (if enabled). Table 1 - Potentiometer Adjustment Range PAGE ADJUSTMENT KEY* RANGE Voting Tone Enable Start: Enable Voting Tone Stop: Disable Voting Tone ADJUSTMENTS 1. P LO P TX P LI P CG P-DC P-DI 1 0-55 0-55 3 0-55 4 0-55 5 0-55 6 0-55 POTENTIOMETER ADJUST MODE The System Module contains up to 13 digital potentiometers (10 in MASTR IIe applications) to set various operational levels. These potentiometers must be adjusted properly to ensure optimum station performance. The potentiometers, their key, and function are listed on one of three pot pages. The pages and associated potentiometers are listed below. Page 3 applies to MASTR III only. The adjustment range for each potentiometer is given in Table 1. Page 1. 1. Line Output Level (P LO). Transmit Level (P TX) 3. Line Input Level (P LI) 4. Channel Guard Level (P CG) 5. DSP Line Cancellation Level (P DC) 6. DSP Line Input Level (P DI) 7. Compressor Level (CP) Page. 1. Voting Tone Gain (VTG). Compressor Threshold (CT) 3. Morse ID Transmit (MCTX) Page 3. 1. PA Power (PA). Repeater Gain (RG) 3. Squelch Pot (SQ). VTG CT MCTX 3. PA RG SQ 1 0-17 0-3767 4 0-55 1 0-99 0-3767 3 0-99 * On each Pot Page the unused key numbers will have no effect. To enter the Adjust Potentiometer Mode from the main menu, press the "A" key. The handset will display "POT P1"for page 1. To select additional pages, press the "A" key again while "POT P1" is still displayed. Toggle it again to select page 3. Select a specific potentiometer by selecting the appropriate page and then pressing the corresponding number key shown in Figure 6. Ramping switches for these adjustments are shown in Figure 7. Note: the "0" key is applicable only to the CP, CT and RG potentiometers (key 7 pg 1, and keys 1, pg and with MASTR III key pg 3.), and is a toggled (Press On-Press Off) function. NOTES It is not necessary to back up 1 level to the POT P1 display to select another pot on the same page. Just press the desired number corresponding to the next pot to be adjusted. To select a pot from another page, press CLR to return to Pot Px display and toggle the "A" key to the desired page. Now, press the desired number key shown in Figure 6. Subsequent pressing of the "A" key will display the last selected page. Pressing the "CLR" key while in the process of actually adjusting a pot will return to the "POT Px" display where "x" was the last page selected. 8

FUNCTION KEY DISPLAY Down 10 Up 10 Power up handset Enter adjust pots mode PAGE 1 None A MENU POT P1 STO * OPR O RCL Down 100 Up 100 10x (only applicable with pot 7) # Line output pot Tx level pot Line input pot QZ 1 ABC DEF 3 P LO XXX P TX XXX P LI XXX Figure 7 - Ramping Switches The handset adjusts potentiometers in real time. These adjustments are recorded in the personality of the System Module. Channel Guard pot DSP line cancellation pot DSP line input pot Compressor Gain pot PAGE Voting Tone Gain Compressor Threshold GHI 4 JKL 5 MNO 6 PRS 7 QZ 1 ABC P CG XXX P DC XXX P DI XXX CP XXXXX VTG CT Service Notes: 1. Potentiometers 5, 6 and 7 (page 1.), 1, and 3 (page ) and 1 and (page 3.) apply to System Modules with the Digital Signal Processing (DSP) board..the Channel Guard Level, TX, and PA pots are channel specific. To correctly set the level associated with a channel, first select a channel using the Channel Select Mode described on this page. Then return to the Adjust Potentiometer Mode and adjust the Channel Guard level pot. (Only applicable to multiple frequency stations.) 3. Also, changing the SQ Pot will have an affect only on those ststions that have been programmed to use the digital squelch pot instead of the manual pot. (The station software must be group 1 or higher, and the MASTR III interface board must have the digital squelch pot on it.) Morse ID Transmit DEF 3 MCTX METERING MODE PAGE 3 PA Power QZ 1 PA The Utility Handset can monitor station performance by providing a readout of various DC voltages in a properly configured station. Repeater Gain ABC RG To enter the Metering Mode from the main menu, press the B key. Back up one level CLR POTP1 Select a specific parameter to measure by pressing the corresponding number key shown below: Return to top level END MENU 1 3 4 Parameter MIIe function PWR Rx Tx Ext Not Used Rx Meter Tx Meter Not Used MIII base station function Analog Range Circulator Power Sensor RSSI, Receiver Sensitivity External Metering Point External Metering Point 0-5V 0-5V 0-5V 0-10V Figure 6 - Potentiometer Adjust Switches 9

The Rx Meter and Tx Meter functions in the MASTR IIe are used with the Meter Switching kit, 19B693G1. See LBI-4848. In the MASTR III, PWR returns a voltage proportional to the reflected power in the circulator. Rx is the RSSI line from the IF module. Tx and EXT are external metering points on the MASTR III and are brought to a header on the MIII backplane for use in special functions. Otherwise, they are available for the operator to use in various metering applications. The display provides the appropriate abbreviations and current level. These readings are updated every seconds (see Figure 8). REMOTE STATION ADJUSTMENTS VIA MODEM Function Key Display Power up handset Enter metering mode To select power None B QZ 1 MENU METER PWR X XX The Handset can also present these data in decimal format. By pressing the "B" key while in the metering mode, the handset will toggle from volts to decimal. The decimal measurement range is 0 to 55. Decimal data are presented with no spaces between the numbers. The default is analog voltages. To select Rx To select Tx To select external ABC DEF 3 GHI 4 RX X XX TX X XX EXT X XX CHANNEL SELECT MODE In multi-frequency stations, the Utility Handset can change the selected channel. To toggle to decimal display B Numbers read with no spaces in decimal: XXX To enter the Channel Select Mode from the main menu, press the "C" key. The display will show the current channel. To change channels press the channel number desired (1-4). Assuming a two channel station with channel 1 as the current channel, pressing the key will result in the handset displaying "C SEL ". In order to complete this channel selection, the C key must be pressed. Now the handset will display "CHAN ". If desired, adjustments to the Channel Guard Level settings for channel may now be made. It should be noted that when the handset is in the Channel Select Mode ("C SEL x"), any entry may be discarded by pressing the CLR key. Pressing the CLR key a second time will return the handset to the "MENU" display. The Channel Select Mode may also be entered from the Channel Display Mode ("CHAN x") by using the "C" key. The resulting display is "C SEL". Channel selection may proceed as described above. Also note that when in the Channel Select Mode, the previously selected channel may be redisplayed by entering an invalid channel number (which includes a blank selection). Figure 8 - Metering Switches Function Key Display Power up handset Display Current channel To select new channel None QZ 1 DEF 3 C C ABC GHI 4 MENU CHAN X C SEL X Figure 9 - Channel Select Switches 10

Remote station adjustments and diagnostics are available using the MASTR IIe/III Utility Program (LBI-38540). The Utility Handset must be used to adjust the baud rate of a remote station. The default settings are: Baud rate 9600 bps Parity NONE Word length 8 bits Stop bits Only the baud rate is programmable. The procedure below allows you to select the baud rate required by your modem. Power up the station. Successful power up will cause the display to show "MENU". From the "MENU" display, press the "#" key. The display will show: BRxxxxx where xxxxx is the current baud rate right-justified in the 8 character display. Numeric keys used to select the baud rates are given below. Keys other than those identified below are invalid and are not operable. 1. 300 baud 4. 4800 baud. 100 baud 5. 9600 baud 3. 400 baud After selecting the desired baud rate, press the STO key to actually change the baud rate in the System Module. MAINTENANCE Refer to Maintenance Manual LBI-38509 for complete maintenance information for the Utility Handset (19A705965P1) or LBI-3841 for Utility Handset (19A705870P). Circuit Analysis Test Specifications Handset Self-Test Outline and Schematic Diagrams Parts List IC Data 11

This page intentionally left blank Ericsson Inc. Private Radio Systems Mountain View Road Lynchburg, Virginia 450 1-800-58-7711 (Outside USA, 804-59-7711) Printed in U.S.A