CEM-C30 INSTRUCTION MANUAL (M017B A)

Similar documents
CEM M-RS485 INSTRUCTION MANUAL (M014B A)

CEM M-ETH INSTRUCTION MANUAL (M060B A)

CEM-C6 INSTRUCTION MANUAL (M187B B)

Connection and configuration of a CDP with KACO NEW ENERGY inverters

SGE-3G/GPRS INSTRUCTION MANUAL (M179B A)

Connection and configuration of a CDP with Fronius MB inverters

CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B B)

Power analyzer CVM-B100 CVM-B150 INSTRUCTION MANUAL (M010B A) MEASURING EQUIPMENT

REACTIVE ENERGY REGULATORS

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

COUNTIS E05. Single-phase energy meter Direct - 40 A M-BUS. Instruction manual. en/countis-e0x

PRO-1250D CT MID DIN rail three phase four wire energy meter.

INSTRUCTION MANUAL (M064B A)

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

USER MANUAL 2012 V1.1

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5

PRO2DM DIN rail single phase two wire energy meter

PRO1 V21.xxx series MID DIN rail single phase two wire energy meter

Electronic earth leakage protection relay

DRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria

PRO1250D CT MODBUS MID Three phase four wire energy meter.

PRO1250D CT M-bus MID DIN rail three phase four wire energy meter. User manual Version 1.11

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

User Manual V2.6. SDM120-Modbus. Single-Phase Multifunction DIN rail Meter

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

POWER CONTROL CA-4. (Cod ) INSTRUCTION MANUAL (M B) (c) CIRCUTOR S.A.

Smart Energy Meter. Benefits and Main Features. User Manual Revision English OB (100)A

XTM1250SA DIN rail three phase four wire LCD display energy meter

Measurement and Control CVM-A1500. Power analyzer with power quality. Quality in every sense of the word. Technology for energy efficiency

Installation and Operating Instructions

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

SDM530CT-Modbus USER MANUAL 2015 V1.6. Three Phase Multi-function DIN rail meter. Eastron SDM530CT-Modbus User Manual

Jiaxing Eastron Electronic Instruments Co.,Ltd. Tel: Fax:

POWER FACTOR REGULATORS

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

SDM530-Modbus USER MANUAL 2015 V1.5. Three Phase Multi-function DIN rail meter. Eastron SDM530-Modbus User Manual

User Manual V1.0 SDM230-DR. Single-Phase Two Module DIN rail Meters

SDM630M CT USER MANUAL 2016 V4.7. DIN Rail Energy Meter for Single and Three Phase Electrical Systems

AP25-1DO METER (MID CERTIFIED) User Manual - Issue 1.0

DATA SHEET. Advanced Energy Meter, AEM 380 & AEM 305

SAVING IS SIMPLE WITH WI-BEEE

PRO-75 SERIES. User manual

POWER FACTOR REGULATOR

OB735 Smart Energy Meter

SUBJECT TO CHANGE WITHOUT NOTICE

MIC-2 Multi-instrument DATA SHEET

Power and accuracy. Versatile. One display can monitor up to 32 measuring modules information

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

EM270. Multi-channel power analyzer. Benefits. Description

Power Meter PowerMonitor 500

Operating instructions. Switching amplifier DN0210 DN / / 2015

DIN Rail Smart Meter for Single and Three Phase Electrical Systems

TECHNICAL DESCRIPTION WM1 6, WM1M6

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

AFQevo Active Multi-Function Filter. AFQevo. Active Multi-Function Filter. Technology for energy efficiency

EM271. Multi-channel power analyzer. Benefits. Description

SPM91 DIN Rail Single Phase Energy Meter Installation & Operation Manual V1.0

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

METERSUK. SmartLink D Y N A M i T E. 3 MOD CT Series. User Manual KEY FEATURES INDEX 3. TECHNICAL DESCRIPTION.

ANALIZZATORE DI RETE TRIFASE 90A

EngyVolt RV12 and RV15

Energy Management Energy Transducer Type ET112

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Technical Specificaions. kwh Energy Meter

User Manual V1.1. SDM120-Modbus(mV) Single-Phase Multifunction DIN rail Meter

MultiCube Single Phase Multi-Function Electricity Meter. Installation and Operation

Technical Specifications. Multi Function Meter

WM20. Power analyzer for three-phase systems. Benefits. Description

PM Series Power Meter

Product Manual for the Mini Industry Meter MIZ Installation I Device description I Operation

MIC-2 MKII, Multi-instrument DATA SHEET

IPM-S500 Series MID SINGLE PHASE AND THREE-PHASE ENERGY COUNTERS

Operating instructions Safe AS-i input module ASIM-C-M About this document. Content

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

Operating instructions. Standstill monitor A / / 2011

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Technical Specifications. Dual Source Energy Meter (EB / DG)

CVM-A1000 CVM-A1500 INSTRUCTION MANUAL (M136B B)

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Operating instructions. Speed monitor D / / 2014

1.2 Foreword. 1.7 Basic errors. 1.8 Description. 1.9 Dimensions Installation Operating

I/O SIGNAL CONDITIONER

MDM 011-Z1 Regen Resistor

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Technical Specifications. Dual Source kwh Energy Meter

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

Handbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a

Language of the manual

Transcription:

Multifunctional energy meter CEM-C30 INSTRUCTION MANUAL (M017B01-03-14A)

2

SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could result in personal injury or material damage. ATTENTION Indicates that special attention should be paid to a specifi c point. If you must handle the unit for its installation, start-up or maintenance, the following should be taken into consideration: Incorrect handling or installation of the unit may result in injury to personnel as well as damage to the unit. In particular, handling with voltages applied may result in electric shock, which may cause death or serious injury to personnel. Defective installation or maintenance may also lead to the risk of fi re. Read the manual carefully prior to connecting the unit. Follow all installation and maintenance instructions throughout the unit s working life. Pay special attention to the installation standards of the National Electrical Code. Refer to the instruction manual before using the unit In this manual, if the instructions marked with this symbol are not respected or carried out correctly, it can result in injury or damage to the unit and /or installations. CIRCUTOR, SA reserves the right to modify features or the product manual without prior notifi cation. DISCLAIMER CIRCUTOR, SA reserves the right to make modifi cations to the device or the unit specifi cations set out in this instruction manual without prior notice. CIRCUTOR, SA on its web site, supplies its customers with the latest versions of the device specifi cations and the most updated manuals. www.circutor.com 3

CONTENTS SAFETY PRECAUTIONS...3 DISCLAIMER...3 CONTENTS...4 REVISION LOG...5 1.- VERIFICATION UPON RECEPTION...6 2.- PRODUCT DESCRIPTION...6 3.- UNIT INSTALLATION...8 3.1.- PRELIMINARY RECOMMENDATIONS...8 3.2.- INSTALLATION...9 3.3.- UNIT TERMINALS...9 3.4.- CONNECTION DIAGRAM...10 3.5.- CONNECTIONS... 11 4.- OPERATION...13 4.1.- BUTTON FUNCTIONS...13 4.2.- DISPLAY...14 4.3.- LED INDICATORS...15 4.4.- DISPLAY MODES:...16 4.4.1. DISPLAY IN STANDBY MODE...16 4.4.2. DISPLAY IN READING MODE...18 4.5.- PARTIAL ENERGY DISPLAY...19 4.6.- INSTANTANEOUS VALUE DISPLAY...21 4.7.- CONFIGURATION...23 4.7.1. Impulse output weight...23 4.7.2. Impulse output type...24 4.7.3. Peripheral address...24 4.7.4. Transmission speed ( Baud rate)...25 4.7.5. Type of communications...26 4.7.6. Energy cost...26 4.7.7. CO 2 emissions...27 4.7.8. Partial energy meter deletion...28 4.7.9. Exiting the setup menu...28 4.8.- MANUFACTURER INFORMATION SCREEN...28 4.9.- PROGRAMMING...30 4.9.1. Voltage primary transformation ratio...30 4.9.2. Voltage secondary transformation ratio...31 4.9.3. Current primary transformation ratio...31 4.9.4. Current secondary transformation ratio...32 4.9.5. Exiting the setup menu...32 4.10.- IMPULSE OUTPUT...33 4.11.- INFRARED COMMUNICATIONS PORT...33 5.- TECHNICAL FEATURES...34 6.- MAINTENANCE AND TECHNICAL SERVICE...37 7.- GUARANTEE...37 8.- CE CERTIFICATE...38 Note: The images of the units are solely for the purpose of illustration and may differ from the original unit. 4

REVISION LOG Table 1: Revision log. Date Revision Description 07/14 M017B01-03-14A Initial Version 5

1.- VERIFICATION UPON RECEPTION Check the following points upon receiving the unit: a) The unit meets the specifications described in your order. b) The unit has not suffered any damage during transport. c) Perform an external visual inspection of the unit prior to switching it on. d) Check that it has been delivered with the following: - An installation guide. If any problem is noticed upon reception, immediately contact the transport company and/or CIRCUTOR's after-sales service. 2.- PRODUCT DESCRIPTION The CEM-C30 static three-phase energy meter measures class B active energy (EN50470) and (optional) class 2 reactive energy (IEC 62053-23), with optional optical communications for expansion with other modules installed on a DIN rail with a service port. The current is measured with the transformer. The unit features: - 2 buttons that allow you to browse the different screens and program the unit. - 2 Verification LEDs. - LCD display, displays all parameters, - 2 connection seals, - 2 terminal covers, to cover the top of the terminal box and the fixing screws. 6

The CEM-C30 is offered in different versions; Table 2 shows all of the possible options of the unit. Table 2: Options of the CEM-C30. Options CEM-C30 Code Connection mode 4 wires 4 Accuracy Class B Active / Does not measure reactive energy 10 Class B Active/ Class 2.0 Reactive energy 12 Measurement voltage 3x57/100... 3x230/400 V V 3x57/100 V L 3x63.5/110 V M 3x127/220 V N 3x230/400 V Q Current measurement Transformer 5(10) A T5 Transformer 5(6) A Frequency 50 Hz A 60 Hz B Automatic (50/60Hz) Communications Without communications 0 Side optical service port 1 Expansion Without inputs/outputs 0 Input/Output (Optocoupler) 1 Model Box for assembly on DIN rail E Number of quadrants 2 Quadrants 0 4 Quadrants 1 Storage in both directions 2 Additional features No special features 0 Example: The code 412VT6A10E10 is an energy meter for assembly on a DIN rail, class B (active) and class 2 (reactive); with 4-wire connection and 4-quadrant measurement; with 3x127/220... 3x230/400 measurement voltages and 5(65) A current measurements at 50Hz; with service optical communications; with optoisolated impulse output and no additional features. T6 C 7

3.- UNIT INSTALLATION 3.1.- PRELIMINARY RECOMMENDATIONS In order to use the unit safely, it is critical that individuals who handle it follow the safety measures set out in the standards of the country where it is being used, use the necessary personal protective equipment, and pay attention to the various warnings indicated in this instruction manual. The CEM-C30 unit must be installed by authorised and qualified staff. The power supply plug must be disconnected and measuring systems switched off before handling, altering the connections or replacing the unit. It is dangerous to handle the unit while it is powered. Also, it is critical to keep the cables in perfect condition in order to avoid accidents, personal injury and damage to installations. The manufacturer of the unit is not responsible for any damage resulting from failure by the user or installer to observe the warnings and/or recommendations set out in this manual, nor for damage resulting from the use of non-original products or accessories or those made by other manufacturers. If an anomaly or malfunction is detected in the unit, do not use the unit to take any measurements. Inspect the work area before taking any measurements. Do not take measurements in dangerous areas or where there is a risk of explosion. Disconnect the unit from the power supply (unit and measuring system power supply) before maintaining, repairing or handling the unit's connections. Please contact the after-sales service if you suspect that there is an operational fault in the unit. 8

3.2.- INSTALLATION On the side of the unit are all of the indications adjusted to the CEI 62052-11 standard. The unit is installed on a DIN rail. All connections are located inside the electric panel. Terminals, opening covers or removing elements can expose parts that are hazardous to the touch while the unit is powered. Do not use the unit until it is fully installed. 3.3.- UNIT TERMINALS Table 3:List of CEM-C30 terminals. Unit terminals 1 : S1, Current input L1 8 : L3, Voltage input L3 2 : L1, Voltage input L1 9 : S2, Current output L3 3 : S2, Current output L1 11 : N, Neutral connection 4 : S1, Current input L2 13 : Auxiliary Power Supply 5 : L2, Voltage input L2 14 : Auxiliary Power Supply 6 : S2, Current output L2 21 : Impulse output (Collector) 7 : S1, Current input L3 22 : Impulse output (Emitter) Figure 1:Terminals of the CEM-C30. 9

3.4.- CONNECTION DIAGRAM Power Supply S2 S1 L1 LOAD P2 S2 S1 P1 P2 S2 S1 P1 P2 P1 L2 L3 N Figure 2: Connection diagram, CEM-C30. 10

3.5.- CONNECTIONS The CEM-C30 has terminal covers to cover the top of the terminal box and the fixing screws (Figure 3). Figure 3: Terminal covers of the CEM-C30. The fixing screws are of the mixed type, allowing the use of PZ2 and flat head screwdrivers. The measurement circuit can be connected with cables with a cross-section of up to 20 mm 2. The power supply and impulse output connection may be made with cables with a cross-section of up to 1.5 mm 2. Once connected, the unit can be protected with two connection seals ( Figure 4). Figure 4: Seal of the CEM-C30. 11

When the unit is connected to the mains, attach the safety label (Figure 6) to terminals 13 and 14, in order to prevent the risk of electric shock caused by an involuntary direct contact. 13 14 13 14 Figure 5: Attaching the safety label. 12

4.- OPERATION The CEM-C30 is an energy meter capable of measuring: Imported and exported active energy and reactive energy in the four quadrants. (according to version). Active, reactive and apparent power (according to version). RMS voltage and current Power factor, PF 4.1.- BUTTON FUNCTIONS The CEM-C30 has 2 buttons that allow you to browse the different screens and program the unit. The button can be sealed to prevent access to the programming of the most relevant parameters. To seal the button, insert the seal through the slot found under the button, Figure 6. Figure 6: Sealing the button. Button functions on the measuring screens (Table 4): Table 4: Button functions on measuring screens. Button Short press Long press (> 2 s) For the cyclic movement. Next screen. Enters reading mode. Enter the programming menu - 13

4.2.- DISPLAY The unit has an LCD where all parameters are displayed. The display is divided into three areas (Figure 7): Figure 7: CEM-C30 Display areas Data line, displaying the values measured by the unit. Units, where the unit of the magnitude being viewed is shown. Indicators, which shows other parameters: Indicates that the energy being viewed is consumed. Indicates that the energy being viewed is generated. Indicates that the energy is inductive. Indicates that the energy is capacitive. COM, indicates that there is a communications module connected. It flashes when the communications are established. 14

4.3.- LED INDICATORS The unit has two verification LEDs: To verify the active energy. To verify the reactive energy (according to version). The weight of the LEDs is 20,000 imp/kwh (kvarh). The LEDs will remain lit when the current is lower than the energy meter start-up current. Once the start-up current is exceeded (due to active or reactive power consumption) the LEDs are turned off and emit impulses that are proportional to the measured energy. Active LED Reactive LED Figure 8:LED Indicators of the CEM-C30. 15

4.4.- DISPLAY MODES: The CEM-C30 has 2 display modes: Display in standby mode Display in reading mode 4.4.1. DISPLAY IN STANDBY MODE With the display in standby mode, all of the information is presented in cyclic form without any need to perform any action on the CEM-C30 buttons. 7 different parameters are viewed in this mode, see Table 5, in which they alternate every 6 seconds. The unit is in this mode by default when none of the buttons are pressed. Short press the time. button to stop the cyclic movement of the parameter being shown at the From then on, short press the button to browse all the parameters defined in Table 5. Table 5: Standby mode displays Screen Parameters Total imported active energy Total exported active energy Reactive energy quadrant L+ total Reactive energy quadrant L- total Reactive energy quadrant C- total 16

Screen Parameters Reactive energy quadrant C+ total Hours of operation from manufacture The standby mode is activated again when no button is pressed for 60 seconds. 17

4.4.2. DISPLAY IN READING MODE The reading mode is activated by a long press on the In reading mode you can: button. View the energies of the partial energy meters. View the voltage, current, active power, apparent power and power factor of the installation. Enter the setup menu. View the manufacturer information. The navigation diagram is shown in Figure 9: Figure 9: Navigation diagram in reading mode of the CEM-C10. Note: PC is a short press on the button (< 2 seconds). PL is a long press (> 2 seconds). 18

4.5.- PARTIAL ENERGY DISPLAY To open the screens where the partial energy meter energies are viewed, long press the button on the display in standby mode. The home screen is displayed Figure 10: Figure 10: Partial energy main screen. Long press the button to access the different partial energy screens. Short press the button to browse the different screens (see Table 6). The PAR icon on the screen indicates that you are viewing the partial energies. Long press the button to exit the partial energy screens. The standby mode is activated again when no button is pressed for 60 seconds. Table 6:Partial energy screens. Screen Parameters Partial imported active energy Partial exported active energy Partial reactive energy, quadrant 1 Partial reactive energy, quadrant 2 Partial reactive energy, quadrant 3 19

Screen Parameters Partial reactive energy, quadrant 4 Hours in partial operation (since the last partial reset ) Cost of the partial active energy consumed (since the last partial reset ) (1) CO 2 emissions into the atmosphere. (since the last partial reset ) (2) (1) If a Cost value has been programmed in the setup menu (see 4.7.6. Coste de la energía ). (2) If a CO 2 emissions value has been programmed in the setup menu (see 4.7.7. Emisiones de CO2 ). 20

4.6.- INSTANTANEOUS VALUE DISPLAY Long press the button in the standby mode screen to open these display screens. Short press the button to display the instantaneous value home screen, Figure 11: Figure 11: Instantaneous Value main screen. Long press the button to open the different screens. Short press the button to browse the different screens (see Table 7). Long press the button to exit the instantaneous values screens. The standby mode is activated again when no button is pressed for 60 seconds. Table 7: Instantaneous value screens Screen Parameters L1 Voltage L2 Voltage L3 Voltage L1 Current L2 Current 21

Screen Parameters L3 Current Active three-phase power Reactive three-phase power Apparent three-phase power L1 Power Factor L2 Power Factor L3 Power Factor 22

4.7.- CONFIGURATION In the setup menu you can: Program the weight and type of impulse output Program the communications. Program the cost of the energy and the CO 2. emissions Partial energy meter deletion. The standby mode is activated again when no button is pressed for 60 seconds. Long press the button in the standby mode screen to open these setup screens. Short press the button to display the home screen, Figure 12: Figure 12: Home setup screen. Long press the button to access the first programming step. 4.7.1. Impulse output weight This is the home screen for entering the weight of the impulse output. Long press the button to view the value to be programmed. To write or modify the value, short press the repeatedly, increasing the value of the flashing digit. button When the desired value is shown on the screen, move onto the next digit with a long press on the button, allowing the remaining values to be modified. To validate the data, move to the last digit and long press the button; the validation screen will appear (Figure 13) indicating that the programming value has been saved. 23

Figure 13: Validation screen. After a few seconds viewing the screen shown on Figure 13, the system returns to the Impulse output weight programming main screen. Minimum value: 99999. Maximum value: 0. Short press the button to access the next programming step. 4.7.2. Impulse output type The impulse output type is selected on this screen, between: kwh or KVArh. Short press the button to browse the different options. To validate the data, long press the button and the validation screen will appear (Figure 13) indicating that the programming value has been saved. After a few seconds viewing the screen shown on Figure 13, the system returns to the Impulse output type programming main screen. Short press the button to access the next programming step. 4.7.3. Peripheral address Note: This is only displayed if there is a CEM M-RS485 (communications interface for the CEM family of units) connected to the unit. This is the home screen for entering the peripheral address. Long press the button to view the value to be programmed. 24

To write or modify the value, short press the repeatedly, increasing the value of the flashing digit. button When the desired value is shown on the screen, move onto the next digit with a long press on the button, allowing the remaining values to be modified. To validate the data, move to the last digit and long press the button; the validation screen will appear (Figure 13) indicating that the programming value has been saved. After a few seconds viewing the screen shown on Figure 13, the system returns to the Peripheral address programming main screen. Minimum value: 1. Maximum value: 254 Short press the button to access the next programming step. 4.7.4. Transmission speed ( Baud rate) Note: This is only displayed if there is a CEM M-RS485 (communications interface for the CEM family of units) connected to the unit. This is the home screen for entering the transmission speed. Long press the button to view the value to be programmed. The transmission speed (Baud rate) is selected on this screen, and may be: 9600, 19200 or 38400. Short press the button to browse the different options. To validate the data, long press the button and the validation screen will appear (Figure 13) indicating that the programming value has been saved. After a few seconds viewing the screen shown on Figure 13, the system returns to the Transmission speed programming main screen. Short press the button to access the next programming step. 25

4.7.5. Type of communications Note: This is only displayed if there is a CEM M-RS485 (communications interface for the CEM family of units) connected to the unit. This is the home screen for selecting the number of bits, the parity and the number of stop bits of the communications frame. Long press the button to view the value to be programmed. This screen shows the different options: 8n1 : 8 bits, no parity, 1 stop bit. 8E1 : 8 bits, even parity, 1 stop bit. 8o1 : 8 bits, odd parity, 1 stop bit. 8n2 : 8 bits, no parity, 2 stop bits. 8E2 : 8 bits, even parity, 2 stop bits. 8o2 : 8 bits, odd parity, 2 stop bits. Short press the button to browse the different options. To validate the data, long press the button and the validation screen will appear (Figure 13) indicating that the programming value has been saved. After a few seconds viewing the screen shown on Figure 13, the system returns to the Communications type programming main screen. Short press the button to access the next programming step. 4.7.6. Energy cost This is the home screen for entering the energy cost per kwh. Long press the button to view the value to be programmed. To write or modify the value, short press the repeatedly, increasing the value of the flashing digit. button When the desired value is shown on the screen, move onto the next digit with a long press on the button, allowing the remaining values to be modified. 26

To validate the data, move to the last digit and long press the button; the validation screen will appear (Figure 13) indicating that the programming value has been saved. After a few seconds viewing the screen shown on Figure 13, the system returns to the Energy cost programming main screen. Minimum value: 0.000 Maximum value: 9999.999 Short press the button to access the next programming step. 4.7.7. CO 2 emissions This is the home screen for entering the ratio of the carbon emissions. The carbon emissions ratio is the amount of emissions released into the atmosphere to produce a unit of electricity (1 kwh). The European mix ratio is approximately 0.65 kgco 2 per kwh. Long press the button to view the value to be programmed. To write or modify the value, short press the repeatedly, increasing the value of the flashing digit. button When the desired value is shown on the screen, move onto the next digit with a long press on the button, allowing the remaining values to be modified. To validate the data, move to the last digit and long press the button; the validation screen will appear (Figure 13) indicating that the programming value has been saved. After a few seconds viewing the screen shown on Figure 13, the system returns to the CO 2 emissions programming main screen. Minimum value: 0.000 Maximum value: 9.000 Short press the button to access the next programming step. 27

4.7.8. Partial energy meter deletion On this screen you select whether or not to delete the partial energy meters. Long press the button to delete the energy meters. The validation screen (Figure 13) will be displayed next, indicating that the energy meters were deleted correctly. After a few seconds viewing the screen shown on Figure 13, the system returns to the Partial energy meter deletion programming main screen. Short press the button to access the next programming step. 4.7.9. Exiting the setup menu When this screen is displayed: Long press the button to exit the setup menu. Short press the button to return to the first setup point ( 4.7.1. Impulse output weight ) 4.8.- MANUFACTURER INFORMATION SCREEN Long press the button in the standby mode screen to open these display screens. Short press the button to display the manufacturer information home screen, Figure 14: Figure 14: Manufacturer information home screen. Long press the button to open the different screens. Short press the button to browse the different screens (see Table 8). Long press the button to exit the instantaneous values screens. The standby mode is activated again when no button is pressed for 60 seconds. Table 8: Manufacturer information screens. 28

Screen Parameters Unit model Version Communications protocol (1) Communications protocol version (1) Active energy with resolution in Wh Reactive energy with resolution varh 32-bit CRC (1) The screen is displayed if there is a CEM M-RS485 (communications interface for units of the CEM family) connected to the unit. 29

4.9.- PROGRAMMING The most relevant parameters in metrological terms are configured in the programming menu. Short press the button to access this menu. This button is sealable, see 4.1.- BUTTON FUNCTIONS, to restrict access to the programming procedures. The standby mode is activated again when no button is pressed for 60 seconds or by short pressing the button. 4.9.1. Voltage primary transformation ratio This is the home screen for entering the voltage primary ratio. Long press the button to view the value to be programmed. To write or modify the value, short press the repeatedly, increasing the value of the flashing digit. button When the desired value is shown on the screen, move onto the next digit with a long press on the button, allowing the remaining values to be modified. To validate the data, move to the last digit and long press the button; the validation screen will appear (Figure 15) indicating that the setup value has been saved. Figure 15: Validation screen. After a few seconds viewing the screen shown on Figure 15, the system returns to the main screen of the Primary voltage transformation ratio. Short press the button to access the next programming step 30

4.9.2. Voltage secondary transformation ratio This is the home screen for entering the voltage secondary ratio. Long press the button to view the value to be programmed. To write or modify the value, short press the repeatedly, increasing the value of the flashing digit. button When the desired value is shown on the screen, move onto the next digit with a long press on the button, allowing the remaining values to be modified. To validate the data, move to the last digit and long press the button; the validation screen will appear (Figure 15) indicating that the setup value has been saved. After a few seconds viewing the screen shown on Figure 15, the system returns to the main screen of the Secondary voltage transformation ratio. Short press the button to access the next programming step 4.9.3. Current primary transformation ratio This is the home screen for entering the current primary ratio. Long press the button to view the value to be programmed. To write or modify the value, short press the repeatedly, increasing the value of the flashing digit. button When the desired value is shown on the screen, move onto the next digit with a long press on the button, allowing the remaining values to be modified. 31

To validate the data, move to the last digit and long press the button; the validation screen will appear (Figure 15) indicating that the setup value has been saved. After a few seconds viewing the screen shown on Figure 15, the system returns to the main screen of the Primary current transformation ratio. Short press the button to access the next programming step 4.9.4. Current secondary transformation ratio This is the home screen for entering the current secondary ratio. Long press the button to view the value to be programmed. To write or modify the value, short press the repeatedly, increasing the value of the flashing digit. button When the desired value is shown on the screen, move onto the next digit with a long press on the button, allowing the remaining values to be modified. To validate the data, move to the last digit and long press the button; the validation screen will appear (Figure 15) indicating that the setup value has been saved. After a few seconds viewing the screen shown on Figure 15, the system returns to the main screen of the Secondary current transformation ratio. 4.9.5. Exiting the setup menu When this screen is displayed: Long press the button to exit the programming menu. Short press the button to return to the first programming point ( 4.9.1. Voltage primary transformation ratio ) 32

4.10.- IMPULSE OUTPUT The energy meter has optocoupler type outputs capable of generating impulses at a previously programmed rate. (See 4.7.1. Impulse output weight and 4.7.2. Impulse output type ) 4.11.- INFRARED COMMUNICATIONS PORT In all versions, the unit has a serial optical communications port, in compliance with the UNE EN 62056-21:2003 Standard. 33

5.- TECHNICAL FEATURES Mode Power supply Auxiliary Rated voltage 230 V ~ Tolerance ± 20 % Frequency Consumption 50...60Hz < 2 W < 10VA (In, Vref (without auxiliary services)) Connection Reference voltages (according to version) Frequency (according to version) Self-consumption of the voltage circuit Voltage Measurement V Three-phase 3x57/100... 3x230/400V ~ 3x57/100 V ~ M N Q 3x63.5/110 V ~ 3x127/220 V ~ 3x230/400 V ~ A B C 50 Hz 60 Hz 50/60 Hz < 2 W < 10VA (In, Vref (without auxiliary services)) L Current measurement (according to version) T6 T5 Current (Ib / Iref) 5 A 5 A Maximum current (Imax) 6 A 10 A Start-up current 0.04% of Itr 0.04% of Itr Self-consumption of the current circuit 0.3 VA @ 10 A 0.3 VA @ 10 A Itr 0.250 A 0.250 A Ist 0.010 A 0.010 A Imin 0.050 A 0.050 A Accuracy Active Energy CEM-C30 MID CEM-C30 Class B (EN 50470) Class 1 (IEC 62053-21) Reactive Energy Class 2.0 (IEC 62053-23) AC voltage 1.2/50ms 0R source impedance Insulation 4kV RMS 50Hz during 1 minute Overimpulse 6 kv at 60º and 240º, with positive and negative polarization Microprocessor AD converter Calculation and processing ARM 16-bit Impulse output Type Optocoupler Operation Emission of impulses proportional to the energy Electrical features Max. 24V 50mA 34

Hardware Communications protocol IR port (service port) EN62056-21 Modbus Baud rate 9600 Data bits 8 Stop bits 1 Parity Display User interface no parity LCD Buttons 2 buttons LED Operating temperature Storage temperature Environmental features 2 LEDs: kwh, 20000 imp/kwh kvarh, 20000 imp/kvarh -25ºC... +70ºC -35ºC... +80ºC Relative humidity (non-condensing) 5... 95% Maximum altitude Dimensions ( Figure 16) Mechanical features 2,000 m IEC60715 Weight 230 g. Enclosure Protection degree EN50022 IP 51 installed IP40 in terminal area 64 70 5 44 90 35.5 45 65 Figure 16: Dimensions of the CEM-C30. 35

Standards Electrical energy metering equipment (AC). Part 1: General requirements, tests and test conditions. Metering equipment (indexes of classes A, B and C) Electrical energy metering equipment (AC). Part 3: Particular requirements. Static active energy meters (classification indexes A, B and C). Electrical energy metering equipment (AC). Particular requirements. Part 21: Static active energy meters (classes 1 and 2) Electrical energy metering equipment (AC). Particular requirements. Part 23: Static reactive energy meters (classes 2 and 3). UNE EN 50470-1:2007 UNE EN 50470-3:2007 IEC 62053-21:2003 IEC 62053-23:2003 36

6.- MAINTENANCE AND TECHNICAL SERVICE In the case of any query in relation to unit operation or malfunction, please contact the CIRCUTOR, SA Technical Support Service. Technical Assistance Service Vial Sant Jordi, s/n, 08232 - Viladecavalls (Barcelona) Tel: 902 449 459 ( España) / +34 937 452 919 (outside of Spain) email: sat@circutor.es 7.- GUARANTEE CIRCUTOR guarantees its products against any manufacturing defect for two years after the delivery of the units. CIRCUTOR will repair or replace any defective factory product returned during the guarantee period. No returns will be accepted and no unit will be repaired or replaced if it is not accompanied by a report indicating the defect detected or the reason for the return. The guarantee will be void if the units has been improperly used or the storage, installation and maintenance instructions listed in this manual have not been followed. Improper usage is defi ned as any operating or storage condition contrary to the national electrical code or that surpasses the limits indicated in the technical and environmental features of this manual. CIRCUTOR accepts no liability due to the possible damage to the unit or other parts of the installation, nor will it cover any possible sanctions derived from a possible failure, improper installation or improper usage of the unit. Consequently, this guarantee does not apply to failures occurring in the following cases: - Overvoltages and/or electrical disturbances in the supply; - Water, if the product does not have the appropriate IP classifi cation; - Poor ventilation and/or excessive temperatures; - Improper installation and/or lack of maintenance; - Buyer repairs or modifi cations without the manufacturer s authorisation. 37

8.- CE CERTIFICATE 38

39

CIRCUTOR, SA Vial Sant Jordi, s/n 08232 -Viladecavalls (Barcelona) Tel.: (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 www.circutor.es central@circutor.es