Chapter 1. Introduction

Similar documents
1.1. Characteristics of GMWIN How to Connect GMWIN to PLC Method of Connection Depth of Connection...

1.1. Characteristics of GMWIN How to Connect GMWIN to PLC Method of Connection Depth of Connection...

Chapter 10 Installation and Testing operation

Chapter 3. Getting Started

8.2 User Defined Protocol Communication

19.Configure HMI as a MODBUS Server

Chapter 2 Using XG5000 Software. 2.1 Screen Configuration. XG5000 screen is composed as shown below. [Screen of XG5000]

Control FPWIN Pro. PLC programming software: one tool for all applications. Control FPWIN Pro is the universal software for all PLCs from Panasonic

User s Manual. LG Programmable Logic Controller Cnet I/F Module G3L-CUEA G4L-CUEA G6L-CUEB G6L-CUEC G7L-CUEB G7L-CUEC GLOFA-GM LG INDUSTRIAL SYSTEMS

User s Manual. LG Programmable Logic Controller Cnet I/F Module G3L-CUEA G4L-CUEA G6L-CUEB G6L-CUEC G7L-CUEB G7L-CUEC GLOFA-GM LG INDUSTRIAL SYSTEMS

3 Connecting to a Controller

!',' *!2(6!'!'!0!! - (''!- 2(6!

Chapter 13: Remotely Download Via Modem_Link

Advantech Multiprog Deploying a project on KW

Set HMI as a MODBUS Server

Windows Me Plug-and-Play

LogicLab 4. new features & enhancements

Please take the time now to check the contents of your package: HPS12U Print Server One CD-ROM Quick Installation Guide One power adapter

Table of Contents. Table of Contents

# Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: or

Contents. IDEC Communication Driver. Driver for Serial communication with Devices using the IDEC MicroSmart Communication Protocol INTRODUCTION...

GSM GPRS Modem 900 / 1800

Mitsubishi FX Ethernet Driver for JMobile

Each special module has its own special function block (Number of program blocks in task)

Configuring Funk RADIUS to Authenticate Cisco Wireless Clients With LEAP

v5: How to restore Exchange databases

ICC. Mitsubishi MELSEC Client Driver Manual INDUSTRIAL CONTROL COMMUNICATIONS, INC Industrial Control Communications, Inc.


FAQ Communication over IE

EQ7000. User Manual. Rev 1.00

Getting Started : W-8037/8337/8737. The Web PAC

PROGRAMMABLE LOGIC CONTROLLERS. Wiley USING CODESYS A PRACTICAL APPROACH TO IEC. Dag H. Hanssen Institute of Engineering and Safety,

POWERLINK. For CODESYS. POWERLINK For CODESYS. Integration package of the standard Industrial Ethernet protocol POWERLINK into CODESYS.

BitPipe Cellular Dev-Kit

How Do You Replace a CPU 41x with the CPU 410-5H Process Automation? SIMATIC PCS 7 FAQ 01/2016

ISPSoft Create a Project

4. In the Address Book drop-down list, click the address book that contains the addresses you want in your distribution list.

Wireless PC Network Settings

Starter Kit Manual. Table of Contents

CDN Series Displays with Profibus-DP ELEN UNI-TXT (ND) protocol PARAMETRIZATION OF PROFIBUS-DP COMMUNICATION INTERFACE

Multi-hop Messaging using SLC 5/05 Processor via Ethernet

Connecting a PC Station to an S using OPC

Perfect CPU for Small to Medium Sized Industrial Automation Systems

Title: Can I use Ethernet to read and write values to my HMI?

Mitsubishi FX Driver for JMobile

Communication Setting Sample

Dip Switch settings for 2-wire and 4-wire configuration. Schneider Electric - Division - Name Date

2 Preparation. 2.1 Items to Check Connecting PC with GP Setting PC Network Setting GP Network...

CP1W-EIP01-US CP1L / CP1H EtherNet/IP Adapter To Allen-Bradley ControlLogix or CompactLogix with EtherNet/IP Setup Guide

Quick Start Guide for IGSS FREE50

DL7000-ETH/DH+ Application Note

D0 DCM Module Setup Direct

SmartAX MT883 ADSL CPE Quick Start

SharePoint 2010 Content Types

DIN Rail Mounted Dial-up Modem Users Manual

Ethernet Communication

Getting Started with IBM Cognos 10 Reports

FAQ Communication via IE

Allen-Bradley Micro800 Series

Intelligent Positioning Drive GEL 6111 CANopen, PROFIBUS DP, Ethernet etc.

While every effort was made to verify the following information, no warranty of accuracy or usability is expressed or implied.

CP30/G30/MC31 Firmware Version 3100 Known Issues

Exchange Address Book Order


FAQ Communication over PROFIBUS

Why can you not transfer the HMI configuration to the panel? - PROFIBUS Connection - FAQ 03/2014

HOW TO INSTALL E-LD TO E-xD USING CONNECTION TO USB CONSOLE

MULTIPROG QUICK START GUIDE

Communication Driver DCON

Advantech Studio Quick Start Manual

FANUC Replacements. GE Fanuc Automation. Logicmaster 90 TCP/IP Windows 95/98 Windows NT. Programmable Control Products. User's Manual Supplement

MBX Network Browser Help 2010 Kepware Technologies

Digi document reference number: _A

Modem Configuration Procedure

JUMO mtron T. Measuring, Control, and Automation System. Features. Brief description. Systembus LAN. Data Sheet Page 1/12. Com1.

RELAY COMMUNICATION CHANNELS

WINDOWS 95 SETUP GUIDE

2 Preparation. 2.1 Items to Check Connecting PC with GP Setting PC Network Setting GP Network

PMAC770 LAN Module User Manual V1.0

Configuring an Omron PLC with Omron FINS Ethernet Driver

Catalog 1 Product Overview General Important User Information About the Gateway Function Features Tec

Introduction. How to Save Documents. Word 2010 Saving. Video: Saving Documents in Word To Use the Save As Command: Page 1

Extending the Use of PLC Simulator Software in Student Laboratory Works

PASSWORD (Creating a program in the PLC and touchscreen)

Serial Communication

Metrowerks CodeWarrior IDE 5.5 Tutorial

INTRODUCTION...2 GENERAL INFORMATION...3 DEVICE CHARACTERISTICS...3 LINK CHARACTERISTICS...3 DRIVER CHARACTERISTICS...3 CONFORMANCE TESTING...

Website: Technical Support: Skype: fcwkkj or Jason.chen842 Phone: QQ Group:

Channel 4. User Manual. Version 2.0

Intech Micro 2400-A16-SD

ProfinetCommander User Manual 3.1 March 2010

The Start menu (overview)

series Guide to MICREX-SX ~ Using simulator function of D300winV3 ~ FEH253-1

Schneider Training Center. Course catalogue 8/13/2018

PLC 5/250 Programmable Controller System Overview

Digital Surveillance Recorder Intelligent Remote Player SW-80 User Menu

installation manual SALES AND ADMINISTRATION (toll free)

FAQ about S7 communication via IE

FlashAir W-02. Firmware Update Tool Ver User s Manual

KS 108 flexible Compact PLC with touch operating screen

Transcription:

Chapter 1. Introduction Chapter 1. Introduction 1.1. Characteristics of GMWIN GMWIN is a programming and debugging tool for the full range of GLOFA PLC. GMWIN software has the following features. 1) Comfortable Interface It is possible to compile and debug several programs at the same time and maximizes user's other convenience. 2) Supporting Various Languages It supports various languages like LD, SFC, IL. So you can select and use applicable language to a system. LD SFC IL 3) Using Variables by Symbol You can create a program using symbols for easy understanding and memory address is also assigned automatically. It supports various data types. So you can create high-leveled programs. 1-1

GMWIN Manual 4) PLC System using Project Unit It is very easy to create and test a program because you can include several programs in one PLC system. 1-2

Chapter 1. Introduction 5) Connecting GMWIN to PLC by Easy Network You can download and monitor programs not only in directly connected PLC but also in a local PLC connected by network. 6) Various PLC Information It is available to monitor various PLC states and to use this function in the program mode. 7) User-Defined Libraries Besides standard functions and function blocks, you can define a frequently used program as one of functions or function blocks for your convenience. 1-3

GMWIN Manual 1.2. How to Connect GMWIN to PLC In connection GMWIN to PLC, you must previously define two options Method of Connectionand Depth of Connectionin Connect Option. There are four kinds of methods of connection, using RS-232C, MODEM, Communication module ( GLOFA Fnet/Mnet for PC ) and Network ( Ethernet ), and three kinds of depth of connections such as Local, Remote 1 and remote 2. When using Windows 3.x for operating system, the connections using Communication module and Network are not supported. Select Connect optionin Project - Option menu. 1.2.1. Method of Connection 1) Connection using RS-232C To use RS-232C connection, connect the RS-232C cable with the serial port in PC and serial port in PLC From the Project Menu, choose Option. Choose Connect Option tab in the Option dialog box. Select RS-232C in Method of Connection. Select Communication Port. Select Depth of Connection and click OK button. Local Connection Select Local in Depth of Connection and click OK button. Choose Connect from the Online Menu 1-4

Chapter 1. Introduction Remote Connection (See GLOFA Fnet/Mnet user's manual for more details), Open Network Type List and select a network type. Type a station number in Station No. Box. Select slot number. Click OK button. Choose Connect from the Online Menu. Note The specification of RS-232C cable connection 1-5

GMWIN Manual 2) Connection using Modem The long distance connection using modem is only available by Remote Connection. To be connected with PLC, the computer link board( GL CUEA ) must be mounted on the computer. From the Project Menu, choose Option. Select Connect Option in Option. Select Modem in Method of Connection. Select Dial-Up Modem or Dedicate Modem. Setup Communication Port(COM1COM4), BPS and Phone No. Click OK button. 1-6

Chapter 1. Introduction 3) Connection using Communication Module To use Communication module connection (GLOFA Fnet for PC or GLOFA Mnet for PC), Fnet(Fieldbus) or Mnet(Mini- MAP) module for PLC and boards for PC. After installing communication board for PC in PC, you must setup the address to be used by communication module for PC with changing config.sys file in Windows folder of PC (See GLOFA Fnet/Mnet user's manual for detail comment). Example) device = c:\windows\emm386.exe noems x=d000-d4000 From the Project Menu, choose Option. Select Connect Option in Option. Select GLOFA Fnet for PC or GLOFA Mnet for PC in Method of Connection. Setup Port Address and Memory Address. Remote Connection (See GLOFA Fnet/Mnet user's manual for detail comment information) Select Station No. Select Online-Connection in menu and click OK button. Choose Connect from the Online Menu. Port Address and Memory Address must be identified with the ones set in the communication board mounted on PC. 1-7

GMWIN Manual 4) Connection using Network Network connection is only available for Remote connection. To use this connection, Enet(Ethernet) module and the network system must be installed. From the Project Menu, choose Option. Select Connect Option in Option. Select Ethernet in Method of Connection. Remote Connection (See GLOFA Fnet/Mnet user's manual for more detail information) Setup IP address. Click OK button. Choose Connect from the Online Menu. 1-8

Chapter 1. Introduction 1.2.2. Depth of Connection 1) Local Connection From the Project Menu, choose Option. Select Connect Option in Option. Select Local in Depth of Connection. Note Click OK button. Choose Connect from the Online Menu. Local Connection for GMWIN and PLC 1-9

GMWIN Manual 2) Remote 1 Connection From the Project Menu, choose Option. Select Connect Option in Option. Select Remote 1 in Depth of Connection. Select Network Type and Slot in Depth of Connection. Select Station No. (only available in GLOFA Fnet, Fdnet and Mnet) or IP address(glofa-enet). decimal or hexadecimal numbers are all available for Station No. Click OK button. 1-10

Chapter 1. Introduction 3) Remote 2 Connection From the Project Menu, choose Option. Select Connect Option in Option. Select Remote 2 in Depth of Connection. Setup Remote 1 Box Select Network Type in Depth of Connection. Select Slot and Station No. Decimal and hexadecimal numbers are all available for the Station No. Setup Remote 2 Box Select Network Type in Depth of Connection. Select Slot and Station No. Decimal and hexadecimal numbers are all available for the Station No. Click OK button. 1-11

GMWIN Manual Note Local Connection, remote 1connection and remote 2 connection are as below. Local Remote 1 Remote 2 RS-232C 1-12