Surge protection for gutter heating systems

Similar documents
Surge protection for frequency converters

White Paper Surge protection for gutter heating systems

Surge protection for LED mast lights

Lightning and surge protection for electromobility

Surge protection for telecommunication connections

Lightning and surge protection for yachts

Lightning and surge protection for single-family houses

BLITZDUCTOR XTU Universal lightning current / surge arrester

Lightning and surge protection for intelligent transformer substations

Technical Data. Circuit Protection - Surge Protection Devices. Ver 1.0 CUSPD1110. Brief product description:

Application-optimised DEHNshield Combined Arrester

Increased Safety for Switchgear Cabinets CI Arresters with Integrated Backup Fuse

R3&A Limited, Cobourg, ON

Surge Protection Devices Ex9UE2

INFORMATION TECHNOLOGY SYSTEMS

White Paper. Lightning and surge protection for free field PV power plants. Contents

Leutron. Lightningand. Surge Protection for Power Net Systems (SPD) with EnerPro Combi-Devices. Seite 0 von14

DEHN protects Biogas Plants.

POWER SUPPLY SYSTEMS SPDs for low-voltage installations and equipment

Overvoltage Protection Devices

MULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing

DEHN protects Photovoltaic Systems.

Overvoltage Protection Devices

Overvoltage Protection Devices

DEHN protects Smart Power Grids.

Overvoltage Protection Devices

wietap wietap Overvoltage Protection Tensions running high

TT-ST-M-2-PE-24DC. Extract from the online catalog. Order No.:

Overvoltage Protection Devices

White Paper. Lightning and surge protection for wind turbines. Contents

White Paper Lightning and surge protection for rooftop photovoltaic systems

DEHNsecure protects Direct Current Applications.

TT-2-PE- 24DC. Extract from the online catalog. Order No.:

CONTA-ELECTRONICS. CONTA-PROTECT overvoltage protection

DEHN tests and analyses DEHN Test Centre.

PT 2X2-HF-24 DC-ST. Extract from the online catalog. Order No.:

VAL-CP-1S-175. Extract from the online catalog. Order No.:

Extract from the online catalog SFP 1-5/120AC Commercial data Product description Technical data Standards

PT 2X2-24DC-ST. Extract from the online catalog. Order No.:

Surge Protection Devices and Surge Protection Kit

Catalogue valid as of January 1,

PT 3-PB-ST. Extract from the online catalog. Order No.:

SPD Catalogue. SPD Catalogue. for AC applications

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

TT-2-PE-M-24DC. Extract from the online catalog. Order No.:

Lightning and Surge Arresters

PT 5-HF- 5 DC-ST. Extract from the online catalog. Order No.:

PT 2-PE/S- 24AC-ST. Extract from the online catalog. Order No.:

Retrofitting sewage plants with lightning and surge protection measures

DEHN protects Photovoltaic Systems.

VAL-CP-3S-350. Extract from the online catalog. Order No.:

Coordinated Surge Protection

Low voltage. Acti 9. the efficiency you deserve. Catalogue 03/2016

Technical features OVR Surge Protective Devices Type 1 & Type 1+2

INFORMATION TECHNOLOGY SYSTEMS SOCKET OUTLET. DSM (RJ45) Surge Arrester. LAN fine protection for fixed installation

Single Pole SPD. Model V20/75-S V20/150-S V20/275-S V20/320-S V20/385-S V20/420-S V20/440-S V20/550-S EN/IEC / UL th

ETITEC - Lightning and Surge Arresters

NEW surge protective devices

A.3 Lightning and surge voltage protection

Deploying surge protective devices (SPDs) in photovoltaic systems. Technical Information

TT-SLKK5/ 24DC. Extract from the online catalog. Order No.:

MANUAL Surge Protectors

TT-UK5/ 24DC. Extract from the online catalog. Order No.:

Overvoltage Protective Devices

Building Surge Protection Information Pack

Lightning Current Equipotential Bonding SPDs

APPLICATION PROPOSAL. Lightning and Surge Protection SV55/E/0112

Protection of PHOTOVOLTAIC SYSTEMS against LIGHTNING and OVERVOLTAGE. Surge Protection Device

Lightning & Surge Protection for Wind Turbine Systems

Type 1 Arresters. Use in installations with short-circuit currents up to 100 ka rms DEHN + SÖHNE / protected by ISO 16016

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Lightning and Surge Arresters

INFORMATION TECHNOLOGY SYSTEMS SPDs FOR COAXIAL CONNECTION. DEHNgate Lightning current and surge arresters

Modular surge protective devices (SPDs) Cat. Nos :

US Catalog March Surge protective devices (SPDs) UL range

The Wave Breaking Factor and it s Vital Role in Surge Protection Device Coordination. Hans Slagter, DEHN + SOHNE

Surge Protection for Low Voltage Power Systems

Motor-protective circuit-breaker, 3p, Ir=16-25A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

Coordination of Surge protection devices

Lightning and surge protection for wind turbines

SPM Series Plug-in Surge Protection

Surge Protection Devices Type 1+2

SPM Series. Plug-in Surge Protection

OPTIMISED LUMINAIRE PROTECTION

INFORMATION TECHNOLOGY SYSTEMS

White Paper SV08/E/0812. Lightning and surge protection for wind turbines.

BS th Edition wiring regulations Furse overview

LIGHTNING PROTECTION FOR ROOFTOP PV PLANTS LIGHTNING & SURGE PROTECTION SYSTEM

Autoprotected Surge Arresters New OVR Plus range

ETD-BL-1T-OFF-CC- 10S

Modular surge protective devices (SPDs)

Electronic timer CT-ERD.12

PHOENIX CONTACT - 01/2007

Power Supply HARTING pcon

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

Modular surge protective devices (SPDs)

DEHN protects Wind Turbines.

RM35LM33MW liquid level control relay RM35-L V AC/DC

MINI-PS AC/10-15DC/8

OPTIMISED LUMINAIRE PROTECTION

Transcription:

Surge protection for gutter heating systems White Paper Contents Structure without external lightning protection system Structure with external lightning protection system www.dehn-international.com

Surge protection for gutter heating systems White Paper Solar radiation and waste heat from buildings may melt ice or snow even under frost conditions. Such melt water then refreezes, preventing water from draining away and causing it to back up. As a result, the roof drainage is blocked and icicles may form which involves an increased risk. An even more serious problem is a heavy snow and ice build up on the roof that may exceed the maximum load capacity of the roof. Gutter heating systems prevent damage provided that their reliable function is ensured even under lightning and surge conditions. Structure without external lightning protection system If a structure has no external lightning protection system, it can be assumed that the operator considers the probability of lightning striking the structure to be low. In this case, type 2 surge arresters according to IEC 60364-1 (HD 60364-1) must be used to protect the structure from inductive coupling. Since both the heating bands and the temperature and moisture sensor are located outside the structure, their connecting cables are exposed to inductive coupling which may cause damage to the structure. For this reason, type 2 surge arresters are installed to protect these cables directly at the entry point into the structure and the feeder cable upstream of the control unit (Figure 1). Structure with external lightning protection system The IEC 62305-1 to 4 (EN 62305-1 to 4) standard must be observed when installing lightning protection systems on structures. In such systems, the gutters and / or downpipes are typically conductively connected to the air-termination systems and are therefore at a high potential in case of a lightning strike. Both the heating band and moisture sensor cables directly contact these lightning current carrying gutters and downpipes, meaning that lightning currents are automatically injected on the cables. For this reason, type 1 lightning current arresters must be installed directly at the point where the cables enter the structure. It must be observed that the lightning current control unit controller temperature sensor power supply heating cable moisture sensor Type DG M TT 2P 275 (TT/TN-S system) DG M TT 275 (TT/TN-S system) BXT ML2 BE S 5 + BXT BAS Part No. 952 110 952 310 920 220 920 300 Figure 1 Control unit protected by surge arresters in a structure without external lightning protection system 2

Surge protection for gutter heating systems White Paper control unit controller temperature sensor power supply heating cable moisture sensor Type DG M TT 2P 275 (TT/TN-S system) DG M TT 275 (TT/TN-S system) BXT ML2 BE S 5 + BXT BAS DSH TT 2P 255 (TT/TN-S system) DSH TN 255 (TN-S system) Part No. 952 110 952 310 920 220 920 300 941 110 941 200 Figure 2 Installation of lightning current and surge arresters if the control unit is located far from the entry point into a structure with external lightning protection system splits both between the down conductors directly connected to the metallic gutter and the down conductors connected to the air-termination mesh. Even if the external lightning protection system only has four down conductors, lightning currents of less than 10 to 12 ka per core are to be expected in case of LPL III. A type 2 surge arrester must be provided in the feeder cable upstream of the control unit (Figure 2). Buildings with an interconnected reinforced concrete or steel frame construction (IEC 62305-4 (EN 62305-4)) are an exception. If the air-termination systems ensure that the cables beyond the roof are not hit by a lightning strike, surge protective devices according to Figure 1 can be used. If loss of the control unit is acceptable (the control unit and / or the incoming cables must not present a risk of fire), the structure can be protected by installing combined arresters directly at the point where the cables enter the structure (Figure 3). 3

Surge protection for gutter heating systems White Paper control unit controller temperature sensor power supply heating cable moisture sensor Type DSH TT 2P 255 (TT/TN-S system) DSH TN 255 (TN-S system) Part No. 941 110 941 200 (observe separation distance!) Figure 3 Installation of lightning current arresters if the control unit (loss is accepted) is located near the entry point into a structure with external lightning protection 4

DEHNguard DG M TT 2P 275 (952 110) Prewired complete unit consisting of a base part and plug-in protection modules High discharge capacity due to heavy-duty zinc oxide varistors / spark gaps High reliability due to "Thermo Dynamic Control" SPD monitoring device Basic circuit diagram DG M TT 2P 275 Dimension drawing DG M TT 2P 275 Modular surge arrester for use in single-phase TT and TN systems ("1+1" circuit). Type DG M TT 2P 275 Part No. 952 110 SPD according to EN 61643-11 / IEC 61643-11 type 2 / class II Nominal a.c. voltage (U N ) 230 V (50 / 60 Hz) Max. continuous operating a.c. voltage [L-N] (U C ) 275 V (50 / 60 Hz) Max. continuous operating a.c. voltage [N-PE] (U C ) 255 V (50 / 60 Hz) Nominal discharge current (8/20 µs) (I n ) 20 ka Max. discharge current (8/20 µs) (I max ) 40 ka Lightning impulse current (10/350 µs) [N-PE] (I imp ) 12 ka Voltage protection level [L-N] (U P ) 1.5 kv Voltage protection level [L-N] at 5 ka (U P ) 1 kv Voltage protection level [N-PE] (U P ) 1.5 kv Follow current extinguishing capability [N-PE] (I fi ) 100 A rms Response time [L-N] (t A ) 25 ns Response time [N-PE] (t A ) 100 ns Max. mains-side overcurrent protection 125 A gg Short-circuit withstand capability for max. mains-side overcurrent protection (I SCCR ) 50 ka rms 335 V / 5 sec. withstand 440 V / 120 min. safe failure Temporary overvoltage (TOV) [N-PE] (U T ) Characteristic 1200 V / 200 ms withstand Operating state / fault indication green / red Number of ports 1 Cross-sectional area (min.) 1.5 mm 2 solid / flexible Cross-sectional area (max.) 35 mm 2 stranded / 25 mm 2 flexible For mounting on 35 mm DIN rails acc. to EN 60715 Enclosure material thermoplastic, red, UL 94 V-0 Place of installation indoor installation Degree of protection IP 20 Capacity 2 module(s), DIN 43880 KEMA, VDE, UL, VdS Weight 242 g Customs tariff number 85363030 GTIN 4013364108417 PU 1 pc(s) 5

DEHNguard DG M TT 275 (952 310) Prewired complete unit consisting of a base part and plug-in protection modules High discharge capacity due to heavy-duty zinc oxide varistors / spark gaps High reliability due to "Thermo Dynamic Control" SPD monitoring device Basic circuit diagram DG M TT 275 Dimension drawing DG M TT 275 Modular surge arrester for use in TT and TN-S systems ("3+1" circuit). Type DG M TT 275 Part No. 952 310 SPD according to EN 61643-11 / IEC 61643-11 type 2 / class II Nominal a.c. voltage (U N ) 230 / 400 V (50 / 60 Hz) Max. continuous operating a.c. voltage [L-N] (U C ) 275 V (50 / 60 Hz) Max. continuous operating a.c. voltage [N-PE] (U C ) 255 V (50 / 60 Hz) Nominal discharge current (8/20 µs) (I n ) 20 ka Max. discharge current (8/20 µs) (I max ) 40 ka Lightning impulse current (10/350 µs) [N-PE] (I imp ) 12 ka Voltage protection level [L-N] (U P ) 1.5 kv Voltage protection level [L-N] at 5 ka (U P ) 1 kv Voltage protection level [N-PE] (U P ) 1.5 kv Follow current extinguishing capability [N-PE] (I fi ) 100 A rms Response time [L-N] (t A ) 25 ns Response time [N-PE] (t A ) 100 ns Max. mains-side overcurrent protection 125 A gg Short-circuit withstand capability for max. mains-side overcurrent protection (I SCCR ) 50 ka rms 335 V / 5 sec. withstand 440 V / 120 min. safe failure Temporary overvoltage (TOV) [N-PE] (U T ) Characteristic 1200 V / 200 ms withstand Operating state / fault indication green / red Number of ports 1 Cross-sectional area (min.) 1.5 mm 2 solid / flexible Cross-sectional area (max.) 35 mm 2 stranded / 25 mm 2 flexible For mounting on 35 mm DIN rails acc. to EN 60715 Enclosure material thermoplastic, red, UL 94 V-0 Place of installation indoor installation Degree of protection IP 20 Capacity 4 module(s), DIN 43880 KEMA, VDE, UL, VdS Weight 450 g Customs tariff number 85363030 GTIN 4013364108479 PU 1 pc(s) 6

DEHNshield DSH TT 2P 255 (941 110) Application-optimised and prewired spark-gap-based type 1 and type 2 combined lightning current and surge arrester Space-saving arrester for compact and simply equipped electrical installations with reduced technical requirements Capable of protecting terminal equipment Basic circuit diagram DSH TT 2P 255 Dimension drawing DSH TT 2P 255 Application-optimised and prewired combined lightning current and surge arrester for single-phase TT and TN-S systems ("1+1" circuit). Type DSH TT 2P 255 Part No. 941 110 SPD according to EN 61643-11 / IEC 61643-11 type 1 + type 2 / class I + class II Energy coordination with terminal equipment ( 5 m) type 1 + type 2 + type 3 Nominal a.c. voltage (U N ) Max. continuous operating a.c. voltage (U C ) 230 V (50 / 60 Hz) 255 V (50 / 60 Hz) Lightning impulse current (10/350 µs) [L+N-PE] (I total ) 25 ka Specific energy [L+N-PE] (W/R) 156.25 kj/ohms Lightning impulse current (10/350 µs) [L-N]/[N-PE] (I imp ) 12.5 / 25 ka Specific energy [L-N]/[N-PE] (W/R) 39.06 / 156.25 kj/ohms Nominal discharge current (8/20 µs) [L-N]/[N-PE] (I n ) 12.5 / 25 ka Voltage protection level [L-N]/[N-PE] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability [L-N]/[N-PE] (I fi ) Follow current limitation / Selectivity 25 ka rms / 100 A rms no tripping of a 32 A gl/gg fuse up to 25 ka rms (prosp.) Response time (t A ) 100 ns Max. mains-side overcurrent protection 160 A gl/gg Temporary overvoltage (TOV) [N-PE] (U T ) Characteristic 440 V / 120 min. withstand 1200 V / 200 ms withstand Operating state / fault indication green / red Number of ports 1 Cross-sectional area (L, N, PE, 9) (min.) Cross-sectional area (L, N, PE, 9) (max.) 1.5 mm 2 solid / flexible 35 mm 2 stranded / 25 mm 2 flexible For mounting on 35 mm DIN rails acc. to EN 60715 Enclosure material thermoplastic, red, UL 94 V-0 Place of installation indoor installation Degree of protection IP 20 Capacity 2 module(s), DIN 43880 KEMA, VDE, UL Weight 275 g Customs tariff number 85363030 GTIN 4013364137899 PU 1 pc(s) 7

DEHNshield DSH TN 255 (941 200) Application-optimised and prewired spark-gap-based type 1 and type 2 combined lightning current and surge arrester Space-saving arrester for compact and simply equipped electrical installations with reduced technical requirements Capable of protecting terminal equipment Basic circuit diagram DSH TN 255 Dimension drawing DSH TN 255 Application-optimised and prewired combined lightning current and surge arrester for single-phase TN systems. Type DSH TN 255 Part No. 941 200 SPD according to EN 61643-11 / IEC 61643-11 type 1 + type 2 / class I + class II Energy coordination with terminal equipment ( 5 m) type 1 + type 2 + type 3 Nominal a.c. voltage (U N ) Max. continuous operating a.c. voltage (U C ) 230 V (50 / 60 Hz) 255 V (50 / 60 Hz) Lightning impulse current (10/350 µs) [L+N-PE] (I total ) 25 ka Specific energy [L+N-PE] (W/R) 156.25 kj/ohms Lightning impulse current (10/350 µs) [L, N-PE] (I imp ) 12.5 ka Specific energy [L,N-PE] (W/R) 39.06 kj/ohms Nominal discharge current (8/20 µs) [L/N-PE]/[L+N-PE] (I n ) 12.5 / 25 ka Voltage protection level [L-PE]/[N-PE] (U P ) 1.5 / 1.5 kv Follow current extinguishing capability a.c. (I fi ) 25 ka rms Follow current limitation / Selectivity no tripping of a 32 A gl/gg fuse up to 25 ka rms (prosp.) Response time (t A ) 100 ns Max. mains-side overcurrent protection 160 A gl/gg 440 V / 120 min. withstand Operating state / fault indication green / red Number of ports 1 Cross-sectional area (L, N, PE, 9) (min.) Cross-sectional area (L, N, PE, 9) (max.) 1.5 mm 2 solid / flexible 35 mm 2 stranded / 25 mm 2 flexible For mounting on 35 mm DIN rails acc. to EN 60715 Enclosure material thermoplastic, red, UL 94 V-0 Place of installation indoor installation Degree of protection IP 20 Capacity 2 module(s), DIN 43880 KEMA, VDE, UL Weight 250 g Customs tariff number 85363030 GTIN 4013364138209 PU 1 pc(s) 8

BLITZDUCTOR XT BXT ML2 BE S 5 (920 220) LifeCheck SPD monitoring function Optimal protection of two single lines and the cable shield For use in conformity with the lightning protection zone concept at the boundaries from 0 A 2 and higher Basic circuit diagram BXT ML2 BE S 5 Dimension drawing BXT ML2 BE S 5 Space-saving combined lightning current and surge arrester module with LifeCheck feature for protecting two single lines sharing a common reference potential as well as unbalanced interfaces, with direct or indirect shield earthing. If LifeCheck detects thermal or electrical overload, the arrester has to be replaced. This status is indicated contactlessly by the DEHNrecord LC / SCM / MCM reader. Type BXT ML2 BE S 5 Part No. 920 220 SPD monitoring system LifeCheck SPD class Nominal voltage (U N ) Max. continuous operating d.c. voltage (U C ) Max. continuous operating a.c. voltage (U C ) Nominal current at 45 C (I L ) D1 Total lightning impulse current (10/350 µs) (I imp ) D1 Lightning impulse current (10/350 µs) per line (I imp ) C2 Total nominal discharge current (8/20 µs) (I n ) C2 Nominal discharge current (8/20 µs) per line (I n ) Voltage protection level line-line for I imp D1 (U p ) Voltage protection level line-pg for I imp D1 (U p ) Voltage protection level line-line at 1 kv/µs C3 (U p ) Voltage protection level line-pg at 1 kv/µs C3 (U p ) Series resistance per line Cut-off frequency line-pg (f G ) Capacitance line-line (C) Capacitance line-pg (C) M 5 V 6.0 V 4.2 V 1.0 A 9 ka 2.5 ka 20 ka 10 ka 29 V 27 V 18 V 9 V 1.0 ohm(s) 1.0 MHz 2.7 nf 5.4 nf Degree of protection (plugged-in) IP 20 Pluggable into Earthing via BXT BAS / BSP BAS 4 base part BXT BAS / BSP BAS 4 base part Enclosure material polyamide PA 6.6 Colour Test standards yellow IEC 61643-21 / EN 61643-21, UL 497B SIL classification up to SIL3 * ) ATEX approvals IECEx approvals CSA & USA Hazloc approvals (1) CSA & USA Hazloc approvals (2) Weight DEKRA 11ATEX0089 X: II 3 G Ex na IIC T4 Gc DEK 11.0032X: Ex na IIC T4 Gc 2516389: Class I Div. 2 GP A, B, C, D T4 2516389: Class I Zone 2, AEx na IIC T4 CSA, GOST, VdS Customs tariff number 85363010 GTIN 4013364118331 PU * ) For more detailed information, please visit www.dehn-international.com. 36 g 1 pc(s) 9

BLITZDUCTOR XT BXT BAS (920 300) Four-pole version for universal use with all types of BSP and BXT / BXTU protection modules No signal interruption if the protection module is removed Universal design without protection elements Basic circuit diagram with and without plugged-in module Dimension drawing BXT BAS The BLITZDUCTOR XT base part is a very space-saving and universal four-pole feed-through terminal for the insertion of a protection module without signal interruption if the protection module is removed. The snap-in mechanism at the supporting foot of the base part allows the protection module to be safely earthed via the DIN rail. Since no components of the protective circuit are situated in the base part, only the protection modules must be maintained. Type BXT BAS Part No. 920 300 Degree of protection IP 20 For mounting on 35 mm DIN rails acc. to EN 60715 Connection (input / output) Signal disconnection screw / screw Cross-sectional area, solid 0.08-4 mm 2 Cross-sectional area, flexible 0.08-2.5 mm 2 Tightening torque (terminals) no 0.4 Nm Earthing via 35 mm DIN rails acc. to EN 60715 Enclosure material polyamide PA 6.6 Colour ATEX approvals DEKRA 11ATEX0089 X: II 3 G Ex na IIC T4 Gc * ) IECEx approvals DEK 11.0032X: Ex na IIC T4 Gc * ) Weight yellow CSA, VdS, UL, GOST Customs tariff number 85369010 GTIN 4013364109179 PU * ) only in connection with an approved protection module 34 g 1 pc(s) 10

www.dehn-international.com/partners Surge Protection DEHN + SÖHNE Hans-Dehn-Str. 1 Tel. +49 9181 906-0 Lightning Protection GmbH + Co.KG. Postfach 1640 Fax +49 9181 906-1100 Safety Equipment 92306 Neumarkt info@dehn.de DEHN protects. Germany www.dehn-international.com www.dehn-international.com/partners Type designations of products mentioned in the white paper being at the same time registered trademarks are not especially marked. So if there is no marking of or this does not mean that the type designation is a free trade name. Neither it can be seen whether patents or utility models and other intellectual and industrial property rights are available. We reserve the right to introduce changes in performance, configuration and technology, dimensions, weights and materials in the course of technical progress. The figures are shown without obligation. Misprints, errors and modifications excepted. Reproduction in any form whatsoever is forbidden without our authorisation. activsense, BLITZDUCTOR, BLITZPLANER, DEHN, DEHN Logo, DEHN schützt, DEHNbloc, DEHNfix, DEHNgrip, DEHNguard, DEHNport, DEHNQUICK, DEHNrapid, DEHNshield, DEHNsnap, DEHNventil, HVI, LifeCheck, Red/Line are protected by German Trade Mark, by Community Trade Mark (EU) and/or in other countries. Foto Ice dam on slate roof by Dmcroof (http://commons.wikimedia.org/wiki/file:ice_dam_slate_roof.jpg); Licence: CC BY-SA 3.0 (http://creativecommons.org/licenses/by-sa/3.0/)