ACS-8-System. Access Control. Performance features at a glance

Similar documents
ACS-8-System. Access Control. Performance features at a glance

Honeywell Security Deutschland. Access Control Systems

PW6000 Modular Access Control System PW6000 Intelligent Controllers and Modules

ACCESS CONTROL SYSTEM

VICON ACCESS CONTROL CONTROLLERS

Building Technologies. Access Control SiPass networked - simple & networkable for everyday use

PRO3200 Professional Modular Access Control Hardware

PRO2200 Professional Modular Access Control Hardware

AC5160 SiPass integrated controller kit

Intelligent Four Lift Controller TS0869

Controller Cardax FT Controller The CardaxFT Controller 5000 is the intelligent field controller in the CardaxFT security system.

SiPass Entro. Open the door to comprehensive security.

Access Easy Control System. Reference Guide

HUDGE STORAGE MEMORY TO CATER FOR FUTURE EXPANSION OPTO ISOLATION FOR BETTER NOISE PROTECTION

Key Switch. Document version: 1.5 (Updated 02 May 2017)

ISC GB-XX ISC GB-XX ISC GB-XX ISC GB-XX

AC5102. Features. Advanced Central Controller

MaCaPS International Ltd

TAC I/NETTM 1284, 1280, Security Control Unit

Technical Instructions MT15000/2 MT15000/2-M

6222 Two Door Module Technical Operations Manual

UC-2000 Installation Manual Unicorn Computers Technology Limited

Smart HUB - HUB to expand one Master Controller s RS-485 port to 8 RS-485 ports - Use 12VDC power

Compass RTU Guide. Version 3.x

IMS AMS 111 II. Automatic Weather Station. Easy and reliable weather monitoring anywhere

iloq S10 Online Configuration Guide

Data sheet VIPA CPU 214PG (214-2BE03)

CardaxFT Reader I/O Interface

IT monitoring. CMC III Monitoring system CMC III system representation CMC III system overview CMC III Processing Unit/Compact...

ACR880 GPRS Portable Smart Card Terminal

Pegasus Equipments Export Limited. Local Contact:

TDSi EXpert type door controllers offer a fully featured door controller with up to 48,000 card memory.

eh880 Secure Smart Card Terminal

Web-based Access Control System. Employee access. EMBEDDED Web Browser

The Cardax FT Controller 6000 can support up to 16 GBUS devices.

Data sheet VIPA CPU 214NET PG (214-2BT13)

General information. Display. Supply voltage. Input current. Encoder supply. Output current

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Web-based Access Control System. Lower Cost of Ownership

Power Panel Integrated control, operation and visualization

General information. Display. Supply voltage

Data sheet CPU 315SB/DPM (315-2AG12)

APP 700 Technical Specification

General information. Display. Supply voltage. Input current

AR6181-MT, AR6182-MT Card reader

Technical Data sheet

T h e re is an upgrade route to larger configurations. O v e rv i e w

Simple & Easy Installation

Access Easy Controller V 1.0

S-Vision. The Digital Video Surveillance System of Shuttle for Home and Office Applications

JUMO mtron T Measuring, Control, and Automation System

General information. Display. Supply voltage

Control Panel CP600 CP651, CP651-WEB

FC2080 Fire control panel (modular)

x x 60 mm, 700 gm. Wall mounted enclosure, 1 Kg. Weatherproof, high impact GF ABS. Remote control and monitoring with debug features

TDSi MICROgarde type door controllers offer a fully featured door controller with up to 25,000 card memory.

STANLEY MANUFACTURED ACCESS CONTROL ACCESS STARTER KIT EASY-TO-USE AND HIGHLY RELIABLE ACCESS CONTROL

Access Professional Edition Selection Guide

General information. Display. Supply voltage. Input current. Encoder supply. Output current

Datenblatt / Specifications. ACR880 GPRS Portable Smart Card Terminal. idvation GmbH

using optional EMX 190 expansion modules), and makes access decisions based on its own distributed

SI410 Sintony Intrusion Control Panel

Access Professional Edition Selection Guide

Lab 5: Access Control Training Station

Data sheet CPU 115 (115-6BL02)

Technical Datasheet. XMP-TMC28xx-xxx

to that area and whether or not the Cardax FT GBUS URI (Standard or person holds these competencies. Wiegand variant)

AC5160 Controller. Fire & Security Products. SiPass integrated

SECURITON Copyright by Securiton

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

ACX Series. Access Controller for Ethernet

Control Panel CP600 CP635, CP635-B, CP635-WEB

Professional Access Control

Data sheet VIPA CPU 115DP (115-6BL22)

_ Access control SISTEMAS DE SEGURIDAD

GAT NET.Controller 7000 Control unit for the GAT NET.Lock 7000

Data sheet CPU 315SB/DPM (315-2AG12)

Control Panel CP600-eCo CP604, CP604-B

Supply voltage. Input current. Encoder supply. Memory

General information. Display. Supply voltage. Input current. Encoder supply. Output current

DORMA. Access Control

Quick Start Installation Guide

General information. Display. Supply voltage

NEW! Smart Camera Series LSIS 400i Fast and simple quality assurance and identification through innovative and high-performance camera technology

PR602LCD v1.0 Installer Manual Rev. A

General information. Display. Supply voltage. Input current. Encoder supply. Output current

WaterCress Portfolio

Smart Camera Series LSIS 400i Fast and simple quality assurance and identification through innovative and high-performance camera technology

i wifinder ООО «ВАЙФАЙНДЕР» Ваш проводник в мир высоких технологий , г. Москва, ул. Гарибальди, д. 21 ИНН КПП

BioStar 2. Web-based Open Integrated Security Platform

Installation / control / monitoring technique. CANopen PLC IL 5504, IN 5504 minimaster

General information. Supply voltage. Input current. Encoder supply. Power loss. Memory

THE SOLUTION. MFW product family DATASHEET. MFW - Modular radio telecontrol system. A system from the. INFOwww.ees-online.de

Installation / Control / Monitoring Technique

Lux Intelligent Emergency Light Testing System. Lx Features

Controller 3000, dependent on reader technology and site configuration. All I/O functionality is provided on the Controller 3000.

ATU800. Technical specification

How to change access rights? With an intelligent cylinder!

SI220 Sintony Intrusion Control Panel

MBM - Modular I/O system IP20

Transcription:

-System Access Control The is an forward-looking access control system which is modular in construction and highly autonomous. A particularly noteworthy performance feature is the flexible and freely-selectable installation technology. This enables conventional connection of up to two separate doors or one door with an internal and external reader. An expansion option of up to max. 8 doors exists via the communication module utilising core-conserving RS-485 bus technology. Additional it is possible to connect online DLC reader modules (door cylinders) and DLF electronic fittings on the RS-485 module bus via radio communication. Standard features include two controllable RS-485 interface drivers integrated in the communication module. The firmware is completely upgradable. Time-consuming EPROM changing during function expansion is thus a thing of the past. New program components and expansions can be imported in the controllers via the access control software (e.g. IQ MultiAccess). Up to 16 units can be operated via an external interface converter. Access control rights are set up and administered via the access control software (e.g. IQ Multi- Access). The contains decision rights for door release and control. Terminals can be integrated directly in existing ethernet networks (LANs) through selective configuration with an ethernet card (026840.29). A maximum expansion of 999 doors per location can be achieved. Performance features at a glance Intelligent access control terminal up to 4 doors (4 doors strikes, 2 readers/keypads directly connectable, 2 futher readers/keypads via RS-485 module bus, expandable up to max. 8 doors via RS-485 module bus) Upgradable program memory and dynamic memory administration Battery-buffered memory (0.5 MB, expandable up to 3.5 MB) Approx. max. 65 500 identification cards* Approx. max. 512 room/time zones* National holiday and leave calendar Booking buffer for max. 65000 events* Clock with date and automatic daylight saving time/normal time changeover VdS approval Connection onboard for: - 2 readers with clock/data interface and 2 keypads with 2-wire interface possible - 4 relay outputs (e.g.: door strike, flash lamp, etc.) - 3 semiconductor outputs (e.g.: threat, watchdog, etc.) User-friendly and flexible event control via inputs and relays Macro-control (IACP control, lift control, etc.) Anti passpack, barring repeated entry, threat code, counter control Lock function with reciprocal door state influence * Values depend on the memory configuration and parameterising of dynamic memory administration.

planning example Host connection possibilities of With IQ MultiAccess, the individual connection possibilities can be combined in any way. MultiAccess Lite does not support controllers. IQ MultiAccess Direct connection via RS-232 or via interface converter COM 1 to 16 or via RDT (Modem / ISDN-card) or via RDT (Modem) or via Ethernet 2

planning example 3

planning example 4

planning example Variable connection diversity - Extension of existing systems with controllers possible without problems (in combination with or as replacement of existing controllers). - MultiAccess for Windows is supported from version 5 and IQ MultiAccess from version 1. - Combination of all connection types supported by the appropriate software (direct connection, interface converter, Ethernet, remote data transmission connection). - Location independent with IQ MultiAccess ISDN Workstation Workstation AC Software AC Software RS 232 LAN ISDN/X25 dedicated line RS 485 LAN Interface converter 1 or 2 lines all together max. 16 devices RS 232 AC Software Workstation 5

026580 Basic system, 12 V DC 12 V DC 10 V DC to 15 V DC without periphery max. 150 ma Operating temperature range -5 C to +55 C Storage temperature range -25 C to +70 C Environmental protection class acc. to VdS II Housing / Dimensions (W x H x D) Sheet steel / 250 x 210 x 100 mm 026585 Basic system, 230 V AC (As for 12 V version) 230 V AC 230 V AC -15% +10% Continuous current consumption 1,4 A Battery space 1x 018003.10 (3,5 Ah) or 2 x 018002.10 (2,0 Ah) Housing / Dimensions (W x H x D) Sheet steel / 350 x 280 x 100 mm Includes 010 690.02 power supply/charger unit Power supply unit selection depends on the connected consumers. 026575 Basic system with freely-selectable power supply unit integration As for 230 V version, but without power supply unit.one of the following power supply/charger units can be utilised, depending on current requirement: 012168 = 80 Ah/continuous current consumption: 3,5 A 012170 = 130 Ah/continuous current consumption: 5,0 A 12 DC 10 V DC to 15 V DC without periphery max. 150 ma Operating temperature range -5 C to +55 C Storage temperature range -25 C to +70 C Environmental protection class acc. to VdS II Housing / Dimensions (W x H x D) Sheet steel / 350 x 280 x 100 mm Memory expansions 026596 1 MB RAM memory card 026597 2 MB RAM memory card 026598 3 MB RAM memory card Function expansion 026587 Communication module The communicates via the communication module with the connected RS-485 users. Standard features include 2 separated RS-485 interface drivers integrated in the communication module. A maximum of 2 communication modules can be integrated per. A maximum of 32 users can be connected simultaneously per. max. 150 ma Module BUS users / RS-485 modules 026590 Input module, RS-485 with potential separation Digital inputs Dimensions (W x H x D) 4 x with potential separation max. 140 ma 9 V DC to 15 V DC 118 x 118 x 30 mm 6

026591 Output module, RS-485 with potential separation Relays Dimensions (W x H x D) 4 x 24 V DC/1 A max. 250 ma 9,5 V DC to 15 V DC 118 x 118 x 30 mm 026592 Input/Output module, RS-485 with potential separation Differential inputs Digital inputs Relays Dimensions (W x H x D) 2 x erasable 2 x with potential separation 2 x 24 V DC /2 A max. 230 ma 9,5 V DC to 15 V DC 118 x 118 x 30 mm 026595.10 Potential separation module, RS-485 A maximum of 4 modules with RS-485 bus without potential separation can be connected to the module. Recommended when using external power supply units and for long bus lines running outdoors as well as for installations over several buildings. Connectable modules are: All readers and keypads with RS-485 and control lead as well as 026593.10 and 026594.10. max. 140 ma 10V DC to 15 V DC Dimensions (W x H x D) 118 x 118 x 30 mm 026593.10 Door module, 12 V DC, RS-485 The complete door periphery is wired to the door module. The door module is a module bus user and communicates with the via an integrated RS-485 interface. The contains the access control rights and makes decisions. The number of doors to control by a door module depends on the access control software used. MultiAccess for Windows: 1 door; IQ MultiAccess: 2 doors. The following components can be connected simultaneously to the door module: - two clock/data readers Inputs: - two Wiegand readers - four detctor lines (e.g. for bold switching contact) - two Wiegand keypads Outputs: - a door release push-button - two relays - a tamper switch - one semiconductor output (If 2 doors are controlled by a door module, the number of inputs and outputs left for individual use reduces as they are required as monitoring contact, door strike relay and door strike key for the second door.) 12 V DC 9 V to 15 V DC in no-load operation without ext. user 15 ma Operating temperature range -5 C to +55 C Storage temperature range -25 C to +70 C Environmental protection class acc. to VdS II Housing / Dimensions (W x H x D) Plastic / 163 x 152 x 40 mm Power supply unit with battery charging circuit 026594.10 Door module, 230 V AC, RS-485 As 12 V version, but with 230 V power supply unit. 230 V AC 230 V AC -15% to +10% in no-load operation without ext. user 65 ma Operating temperature range -5 C to +55 C Storage temperature range -25 C to +70 C Environmental protection class acc. to VdS II Battery space 1 x 018002.10 (2,0 Ah) Housing / Dimensions (W x H x D) Plastic / 250 x 210 x 100 mm 7

Additional performance features 4 digital inputs (e.g.: door strike push-button, monitoring contact, etc.) 8 differential detector groups (e.g.: magnetic contact, glass breakage sensor, etc.) Integrated tamper contact Optional host interfaces (RS-485, RS-232, 10/100 Mbit/s fast ethernet, Current Loop) Variable door release, monitoring and alarm times Automatic function control via time zones (e.g.: door release, etc.) Special relay function for real-time release for rescue route integration RS-485 module bus (optional) Flexible power supply unit configuration, depending on power requirement 12 V DC emergency power supply, depending on power supply unit configuration and power requirement VdS-approval Z 105009, class C Support of analog modems and ISDN terminal adapters Direct modem connection without additional card The following components can be connected to the communication module RS-485 magnetic card reader RS-485 Legic reader RS-485 mifare reader RS-485 Esser reader contactless RS-485 keypad RS-485 12 V version/230 V version door module RS-485 input module RS-485 output module RS-485 input/output module Traffic point RS-485 for DLC and DLF online Biometrics: Fingerkey and/or integration of biometrical systems via RS-485 module bus Arming/disarming of an intrusion detection system via AC-readers to be realized using inputs/outputs and macro programming in IQ MultiAccess Accessories 026692 RS-485 interface (5-wire / 3-wire) without potential separation 026693 RS-485 interface (5-wire / 3-wire) with potential separation 026840.03 Asynchronous RS-232 host interface 026840.29 10/100 MBit/s ethernet host interface 018002.10 Rechargeable battery 12 V DC / 2.0 Ah 018003.10 Rechargeable battery 12 V DC / 3.5 Ah 012168 Power supply/charging unit 80 Ah/permanent current drain: 3,5 A 012170 Power supply/charging unit 130 Ah/permanent current drain: 5,0 A Order data Item no. Description Item no. Description Central control unit versions 026580 Basic system, 12 V DC approval Z 105009, class C 026585 Basic system, 230 V AC (includes 010690.02 power supply/charger unit) approval Z 105009, class C 026575 Basic system with freely-selectable power supply unit integration (power supply unit selection depends on the connected consumers, VdS only with power supply units approved by VdS) approval Z 105009, class C 026587 Communication module (required for controlling more than 2 doors) Module bus users / RS-485 modules 026590 Input module, RS-485 with potential separation 026591 Output module, RS-485 with potential separation 026592 Input/Output module, RS-485 with potential separation 026595.10 Potential seperation module, RS-485 026593.10 Door module, 12, V DC, RS-485 026594.10 Door module, 230 V AC, RS-485 022963 Traffic point RS-485 for DLC and DLF online For further data and information on DLC and DLF products see our product catalogue. Honeywell Security Group Novar GmbH Joh.-Mauthe-Str. 14 D-72458 Albstadt Phone +49 (0) 74 31/801-0 Fax 801-12 20 www.honeywell.com/security/de info.security.de@honeywell.com P32501-22-0G0-05 06. 2011 Subject to change without notice. 2011 Honeywell International Inc.