Model 4148 48 SPDT Switch Module 90900210 Page 1
All technical data and specifications in this publication are subject to change without prior notice and do not represent a commitment on the part of Giga-tronics, Incorporated. 2011 Giga-tronics Incorporated. All rights reserved. Printed in the U.S.A. Warranty Giga-tronics Series 3000 Switching Modules are warranted against defective materials and workmanship for three years from date of shipment, or as detailed in the warranty section of this manual. Giga-tronics will, at its option, repair or replace products that are proven defective during the warranty period. This warranty DOES NOT cover damage resulting from improper use, nor workmanship other than Giga-tronics service. There is no implied warranty of fitness for a particular purpose, nor is Giga-tronics liable for any consequential damages. Specification and price change privileges are reserved by Giga-tronics. CONTACT INFORMATION Giga-tronics, Incorporated 4650 Norris Canyon Road San Ramon, California 94583 Telephone: 800.726.4442 (only within the United States) 925.328.4650 Fax: 925.328.4700 On the Internet: www.gigatronics.com Page 2
Regulatory compliance information This product complies with the essential requirements of the following applicable European Directives, and carries the CE mark accordingly. 89/336/EEC and 73/23/EEC EN61010-1 (1993) EN61326-1 (1997) Manufacturer s Name: Giga-tronics, Incorporated EMC Directive and Low Voltage Directive Electrical Safety EMC Emissions and Immunity Manufacturer s Address 4650 Norris Canyon Road San Ramon, California 94583 U.S.A. Type of Equipment: Model Series Number Switching Module 4148 Declaration of Conformity on file. Contact Giga-tronics at the following; Giga-tronics, Incorporated 4650 Norris Canyon Road San Ramon, California 94583 Telephone: 800.726.4442 (only within the United States) 925.328.4650 Fax: 925.328.4700 Page 3
Record of Changes to This Manual Use the table below to maintain a permanent record of changes to this document. Corrected replacement pages are issued as Technical Publication Change Instructions (TPCI). When you are issued a TPCI, do the following: 1. Insert the TPCI at the front of the manual binder. 2. Remove the pages from the manual binder that are noted in the TPCI. 3. Replace the page(s) removed in the previous step with the corrected page(s). 4. Record the changes in the table below. TPCI Number TPCI Issue Date Date Entered Comments Page 4
Revision History Revision Description of Change Chg Order # Approved By A Initial Release 11/98 JL B Updated C Reformatted 3/12 RCW Page 5
Contents Contents... 6 Chapter 1 Introduction... 7 1.1 Safety and Manual Conventions... 7 1.1.1 Product Reference... 7 1.1.2 Personal Safety Alert... 7 1.1.3 Equipment Safety Alert... 7 1.1.4 Notes... 7 1.1.5 Electrical Safety Precautions... 7 Chapter 2 Functional Description... 8 2.1 Introduction... 8 2.2 General Description... 8 Chapter 3 Block Diagram... 9 Chapter 4 Specifications... 10 Chapter 5 Register Map... 11 Page 6
1.1 Safety and Manual Conventions Chapter 1 Introduction This manual contains conventions regarding safety and equipment usage as described below. 1.1.1 Product Reference Throughout this manual, the term Common Core Switching Platform, Series 8800 refers to all models of within the series, unless otherwise specified. 1.1.2 Personal Safety Alert WARNING: Indicates a hazardous situation which, if not avoided, could result in WARNING death or serious injury.! 1.1.3 Equipment Safety Alert CAUTION CAUTION: Indicates a situation which can damage or adversely affect the product or associated equipment. 1.1.4 Notes Notes are denoted and used as follows: NOTE: Highlights or amplifies an essential operating or maintenance procedure, practice, condition or statement. 1.1.5 Electrical Safety Precautions Any servicing instructions are for use by service-trained personnel only. To avoid personal injury, do not perform any service unless you are qualified to do so. For continued protections against fire hazard, replace the AC line fuse only with a fuse of the same current rating and type. Do not use repaired fuses or short circuited fuse holders. Page 7
Chapter 2 Functional Description 2.1 Introduction This manual provides the necessary information for the Model 4148 card assembly. 2.2 General Description The Model 4148 module contains 48 SPDT general-purpose relays. This card assembly fits in an ASCOR s series 4000 VXI host modules that can be a 3 wide to 8 wide VXI module with the capacity for six to 17 card assemblies. This allows of ease in design of complex switch systems. This architecture produces a high performance switch system without the usual custom designs or external wiring and integration efforts. The interface and mechanical construction of the Series 4000 VXI module and card assemblies meets the specification of the VXIbus System Specification, rev. 1.2 and 1.3. Note: This card assembly requires an ASCOR Series 4000 host VXI module. It is not a stand-alone VXI module. Page 8
Chapter 3 Block Diagram Analog Groundplane Typical Channel (1 of 48) Page 9
Chapter 4 Specifications Electrical: Switching Voltage (DC/Peak, AC, Resistive): 220VDC, 250VACpk Switching Current (DC/Peak, AC, Resistive): 2 Amps Carry Current(DC/Peak, AC, Resistive): 2 Amps Max Switching Power: 60W, 1250VA Life expectancy @ Signal < 1.0V, 0.010A) 1,000,000 Contact resistance <100 mω Bandwidth: 235 MHz Crosstalk: -120 db at 200 MHz Characteristic impedance: 50 ohms Mechanical: Thickness: Width: Length: Weight: 0.6 inches 7.825 inches 10.75 inches 1 lbs. Connectors: Connector: Mating Connector: 3M Type N102A0-5242VC 3M Type 101A0-6000EC Environmental Specifications Temperature: Operating: 0º to 55ºC Storage: - 40º to 75ºC Relative Humidity: Operating: Storage: 0 to 90% non-condensing 0 to 95% non-condensing Page 10
Chapter 5 Register Map The module is organized into three 16 bit registers with each register controlling 16 relays. Register Map A16 Register Offset 00h 02h 04h 06h Value 7Fb5h 7= Register Based, A16/A24 Module FB5=VXI Manufacturer ID, ASCOR 7xxxh 7=A24 space requirement xxx= Model Number for this module (see host module) FFFCh (assigned by Resource Manager) Control Bit 3Eh 0 Low true output to enable coil driver IC s 1 When low enables readback of coil state 2 High true EEPROM write enable (factory only) 3-15 Don t care MSB LSB REG 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 0 8000h K16 K15 K14 K13 K12 K11 K10 K9 K8 K7 K6 K5 K4 K3 K2 K1 8002h K32 K31 K30 K29 K28 K27 K26 K25 K24 K23 K22 K21 K20 K19 K18 K17 8004h K48 K47 K46 K45 K44 K43 K42 K41 K40 K39 K38 K37 K36 K35 K34 K33 Page 11
16-Bit Mode Note: nc =normally closed, no =normally open, com =common, shld =shield REGISTER: 8000h MODE: 16 bit FUNCTION: Control K1 through K16 BIT FUNCTION CONNECTION, nc, no, com, shld. RELAY COMMENT 0 K1 J1-47, 49, 48, 46 K1 1 K2 J1-97, 99, 98, 96 K2 2 K3 J1-43, 45, 44, 42 K3 3 K4 J1-93, 95, 94, 92 K4 4 K5 J1-39, 41, 40, 38 K5 5 K6 J1-89, 91, 90, 88 K6 6 K7 J1-35, 37, 36, 34 K7 7 K8 J1-85, 87, 86, 84 K8 8 K9 J1-31, 33, 32, 30 K9 9 K10 J1-81, 83, 82, 80 K10 10 K11 J1-27, 29, 28, 26 K11 11 K12 J1-77, 79, 78, 75 K12 12 K13 J1-23, 25, 24, 22 K13 13 K14 J1-73, 75, 74, 72 K14 14 K15 J1-19, 21, 20, 18 K15 15 K16 J1-69, 71, 70, 68 K16 note: shield is also available on pin J1-1, 50, 51, 100 REGISTER: 8002h MODE: 16 bit FUNCTION: Control K17 through K32 BIT FUNCTION CONNECTION, nc, no, com, shld. RELAY COMMENT 0 K17 J1-15, 17, 16, 14 K17 1 K18 J1-65, 67, 66, 64 K18 2 K19 J1-11, 13, 12, 10 K19 3 K20 J1-61, 63, 62, 60 K20 4 K21 J1-7, 9, 8, 6 K21 5 K22 J1-57, 59, 58, 56 K22 6 K23 J1-3, 5, 4, 2 K23 7 K24 J1-53, 55, 54, 52 K24 8 K25 J2-47, 49, 48, 46 K25 9 K26 J2-97, 99, 98, 96 K26 10 K27 J2-43, 45, 44, 42 K27 11 K28 J2-93, 95, 94, 92 K28 12 K29 J2-39, 41, 40, 38 K29 13 K30 J2-89, 91, 90, 88 K30 14 K31 J2-35, 37, 36, 34 K31 15 K32 J2-85, 87, 86, 84 K32 Page 12
REGISTER: 8004h MODE: 16 bit FUNCTION: Control K33 through K48 BIT FUNCTION CONNECTION, nc, no, com, shld. RELAY COMMENT 0 K33 J2-31, 33, 32, 30 K33 Group 2 pin1 1 K34 J2-81, 83, 82, 80 K34 Group 2 pin2 2 K35 J2-27, 29, 28, 26 K35 Group 2 pin3 3 K36 J2-77, 79, 78, 75 K36 Group 2 pin4 4 K37 J2-23, 25, 24, 22 K37 Group 2 pin5 5 K38 J2-73, 75, 74, 72 K38 Group 2 pin6 6 K39 J2-19, 21, 20, 18 K39 Group 2 pin7 7 K40 J2-69, 71, 70, 68 K40 Group 2 pin8 8 K41 J2-15, 17, 16, 14 K41 Group 2 pin9 9 K42 J2-65, 67, 66, 64 K42 Group 2 pin10 10 K43 J2-11, 13, 12, 10 K43 Group 2 pin11 11 K44 J2-61, 63, 62, 60 K44 Group 2 pin12 12 K45 J2-7, 9, 8, 6 K45 Group 2 pin13 13 K46 J2-57, 59, 58, 56 K46 Group 2 pin14 14 K47 J2-3, 5, 4, 2 K47 Group 2 pin15 15 K48 J2-53, 55, 54, 52 K48 Group 2 pin16 Page 13
32-Bit Mode REGISTER: 8000h MODE: 32 bit FUNCTION: Control K1 through K32, Group 1, 1x32 pins 1-32 BIT FUNCTION CONNECTION, nc, no, com, shld. RELAY COMMENT 0 K1 J1-47, 49, 48, 46 K1 1 K2 J1-97, 99, 98, 96 K2 2 K3 J1-43, 45, 44, 42 K3 3 K4 J1-93, 95, 94, 92 K4 4 K5 J1-39, 41, 40, 38 K5 5 K6 J1-89, 91, 90, 88 K6 6 K7 J1-35, 37, 36, 34 K7 7 K8 J1-85, 87, 86, 84 K8 8 K9 J1-31, 33, 32, 30 K9 9 K10 J1-81, 83, 82, 80 K10 10 K11 J1-27, 29, 28, 26 K11 11 K12 J1-77, 79, 78, 75 K12 12 K13 J1-23, 25, 24, 22 K13 13 K14 J1-73, 75, 74, 72 K14 14 K15 J1-19, 21, 20, 18 K15 15 K16 J1-69, 71, 70, 68 K16 16 K17 J1-15, 17, 16, 14 K17 17 K18 J1-65, 67, 66, 64 K18 18 K19 J1-11, 13, 12, 10 K19 19 K20 J1-61, 63, 62, 60 K20 20 K21 J1-7, 9, 8, 6 K21 21 K22 J1-57, 59, 58, 56 K22 22 K23 J1-3, 5, 4, 2 K23 23 K24 J1-53, 55, 54, 52 K24 24 K25 J2-47, 49, 48, 46 K25 25 K26 J2-97, 99, 98, 96 K26 26 K27 J2-43, 45, 44, 42 K27 27 K28 J2-93, 95, 94, 92 K28 28 K29 J2-39, 41, 40, 38 K29 29 K30 J2-89, 91, 90, 88 K30 30 K31 J2-35, 37, 36, 34 K31 31 K32 J2-85, 87, 86, 84 K32 Page 14
REGISTER: 8004h MODE: 32 bit FUNCTION: Control K33 through K48 BIT FUNCTION CONNECTION, nc, no, com, shld. RELAY COMMENT 0 K33 J2-31, 33, 32, 30 K33 1 K34 J2-81, 83, 82, 80 K34 2 K35 J2-27, 29, 28, 26 K35 3 K36 J2-77, 79, 78, 75 K36 4 K37 J2-23, 25, 24, 22 K37 5 K38 J2-73, 75, 74, 72 K38 6 K39 J2-19, 21, 20, 18 K39 7 K40 J2-69, 71, 70, 68 K40 8 K41 J2-15, 17, 16, 14 K41 9 K42 J2-65, 67, 66, 64 K42 10 K43 J2-11, 13, 12, 10 K43 11 K44 J2-61, 63, 62, 60 K44 12 K45 J2-7, 9, 8, 6 K45 13 K46 J2-57, 59, 58, 56 K46 14 K47 J2-3, 5, 4, 2 K47 15 K48 J2-53, 55, 54, 52 K48 16 n/a n/a n/a 17 n/a n/a n/a 18 n/a n/a n/a 19 n/a n/a n/a 20 n/a n/a n/a 21 n/a n/a n/a 22 n/a n/a n/a 23 n/a n/a n/a 24 n/a n/a n/a 25 n/a n/a n/a 26 n/a n/a n/a 27 n/a n/a n/a 28 n/a n/a n/a 29 n/a n/a n/a 30 n/a n/a n/a 31 n/a n/a n/a Page 15
ASCOR 4148 VXI Card Assemby Module Programming Guide The base offset address for the Model 4148 is 8000h. The total offset of the card is dependent on the location of the card in the host VXI module, Series 4000. The offset is x8000h where x is the card location number in hexidecimal. refer to the program guide in the Series 4000 host VXI module manual for programing this card Page 16