Atlas ATLAS INSTALLATION MANUAL SECTIONS INDEX EQUIPMENT / MAIN FUNCTIONS TECHNICAL FEATURES ATLAS: PIN IN/OUT / GENERAL VIEW

Similar documents
User Manual. cmt-svr Startup Guide

Matrix-710. Linux-Ready Cortex-A5 Industry IoT Gateway. Hardware Guide. Version: Nov.

S SENECA. Installation Manual Z-TWS4. Z-PC Line. Web Multifunction Controller Straton / Linux

ACTpro Single Door IP Controller. Operating & Installation Instructions

User Manual. cmt-svr Startup Guide

Matrix-700 Linux-Ready Cortex-A5 Industry IoT Gateway Hardware Guide

x1r 696 x1r 699 SA x1r 699 SA The installation of the device requires the intervention of qualified staff, adequately trained by ISEO.

Specification Manual

256 MB RAM. 256 MB 32 bits RISC Cortex-A8 600MHz SD Card Slot. N/A USB Host. N/A USB Client

Product startup: G-30 + DIGIWARE C31 - U30-3xI35

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

Industrial Serial Device Server

OnRISC. OnRISC Baltos ir 2110

Additional board ZIB2-PDx-N for Plug & Drive motors PDx-N

UC-2000 Installation Manual Unicorn Computers Technology Limited

REX F-0-9 Standalone or Access Controller

CRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09

Wiring Guide EP.NMINI. Version 1.02 Last Updated:

Installation and Configuration Quick Guide. R3000 Lite. Industrial Dual SIM Cellular VPN Router (1 Eth + 1 RS RS USB Host)

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

ACTpro 1500 Single Door IP Controller

Domino DFWEB. DFWEB: interface module between Domino bus and Ethernet network with Web-Server function. Module Connection. Domino

AT-501 Cortex-A5 System On Module Product Brief

pcduino V3B XC4350 User Manual

STANDALONE INTERFACES USB-DMX 512 & 1024 CHANNELS V.1.1

Installation and Configuration Quick Guide. R3000 Quad. Industrial Cellular VPN Router with 4 Ethernet Ports (4 Eth + 1 RS-232/1 RS USB Host)

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

Installation and Configuration Quick Guide R3000. Industrial Dual SIM Cellular VPN Router 2 Eth + 1 RS RS USB Host.

Short Instructions CG-S / IP-Router

RELAY MODULE A/B INSTALLATION/USE INSTRUCTIONS

Connecting a Cisco Reader Module

icex-cmtm General specs and Installation guide

Installation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT

Access Control System

Installation & User Manual

VPROX 250 Ver KEYS/TAGS 3 DOORS SYSTEM DESCRIPTION

0B specifications 1B

LinkSprite Technologies,.Inc. pcduino V2

JetBox 9300/9310 User Manual. Hardware

TLE9869 Eval.Kit V1.0 Users Manual

Technical Manual Nova: Cabinet Security Management System (CSMS)

EyeCheck Smart Cameras

MXPLC. Compact PLC process station. Summary. Application HVAC control systems, data acquisition, interfacing 3 rd party systems.

I-7570 Serial To HART Converter

Product description Rev. 3 11/06/14

Installation & User Manual V2.08

Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

DL-HD2100 Quick Install Guide

UR72 & UR75 Industrial Cellular Router

AR-721E-V2 (AR-721E-V2-X) AR-701B-X Fit 35mm DIN Rail or Mount directly 16,000 32,000. Connector CN18 Host TCP/IP. Code Pin Description

Click-A-Tune. User Manual

Wi125 Evaluation Kit User Manual

Control Panel CP600 CP635, CP635-B, CP635-WEB

EMBEDDED HARDWARE. Core Board. ARM7 Development board. ARM7 Evaluation Board. Page 1 of 5

7I44 MANUAL 8 CHANNEL RS-422 INTERFACE

Quick Installation Guide

SALLIS. Installation & Maintenance Guide. Issue: /07/03. Author: Jon Mendizabal

ARDUINO LEONARDO ETH Code: A000022

MICRO-1356 MULTI-PROTOCOL READER

Translink Controller Installation Manual V1.0

IntesisBox Modbus Server Fidelio IP

and/or b. an optional internal Iridium satellite modem.

Digital Keypad Introduction

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

DEV-1 HamStack Development Board

UR51 Industrial Cellular Router

Control Panel CP600 CP651, CP651-WEB

WRM 247+ QUICK GUIDE

7I74 MANUAL 8 CHANNEL RS-422 INTERFACE

QUICK START G U I D E. GWG Gateway GWG-30, GWG-40

BPI-D1 User Manual. SinoVoip Co.,Limited

Key Switch. Document version: 1.5 (Updated 02 May 2017)

IMIO100 IMIO105. DDC controllers. Summary

Installation manual Card reader Sirius i80l(p) o Product o Installation o Connection o Technical data

Aport-214PG FreeRTOS Programmable Device Server Hardware Guide

the Interactive Catalog

Fingerprint Access Control F1. User Manual

The ECL Apex 20 is operated by means of either a PC or the ECL Apex Web Panel. Temperature input signals are based on Pt 1000 or 0-10 V.

Installing Keypad and Backplate

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

PR602LCD v1.0 Installer Manual Rev. A

User Guide. Model: ELT0702

NxtG-V Install Manual

INDEX. Analog Board Boot and Voltage Test 2 Testing Input Channels 3 Testing Output Channels 4

PA5000 SERIES USER MANUAL

参考資料. LinkSprite.com. pcduino V2

VirtualSCADA VSU-485G USB to RS422/485 Isolated Converter User Manual

R O U T E R М Т 0 1 V e r s i o n v А Т O M e v e r i t h i n g n e w e m e r g e s n o w

Andover ContinuumTM. b3850 Series Terminal Controllers

Technical Manual - Part 2

W Series. Color Screen Fingerprint & Card Time Attendance and Access Control W 1 W 2

APC100. User Manual.

USER INSTRUCTION MANUAL FOR LOADCELL TRANSMITTER MODEL TDC/I/0550 (SOFTWARE: VER2A) INDEX

Product Specification

PA2000 SERIES. USER MANUAL Rev. P CELL PHONE ENTRY SYSTEM. Platinum Access Systems Inc.

Chapter1. Interface Introduction

Transcription:

Atlas INSTALLATION MANUAL SECTIONS INDEX EQUIPMENT / MAIN FUNCTIONS 1 TECHNICAL FEATURES 2 : PIN IN/OUT / GENERAL VIEW 3 : IP ADDRESS CONFIGURATION 4 WARNINGS 5 SETTING TABLES 6 : CONNECTIONS EXAMPLES 7 MAINTENANCE: CHARGING INTERNAL BATTERIES 8 1.1 EQUIPMENT SERVER FOR RFID AND F9000 OFF-LINE DEVICES Product code: 5E002010 Package: 1 server with connectors 1 power supply 1 installation manual 1.2 MAIN FUNCTIONS Embedded Linux server Ethernet TCP/IP 10/100 base T connection n. 1 Lockbus channel to connect Stylos readers and actuators (max 88) n. 2 RS485 channels to connect F9000 on-line readers (max 2) Compatible with Lockbus and RS485 readers and actuators n. 2 USB Host channels ( 1 USB channel for configuration) n. 1 MicroSD slot Desktop housing Power supply 12-24Vdc Power supply 230Vac/24Vdc 35W included Maximum Power Consumption 10 W (no connected devices) 2. TECHNICAL FEATURES Communication interfaces: - 1 Ethernet interface TCP/IP 10/100 base T - 1 Lockbus channel - 2 RS485 channels - 2 USB channels - 1 USB channel for configuration - 1 serial interface (debug) Power supply: - 12-24Vdc - Maximum power consumption 10W Power Supplier: - Input 230Vac - Output 24 Vdc 35W - 2 poles plug Backup batteries: - 1500mAh battery pack - estimated duration 30 minutes backup CPU and memory: - ARM 9 based CPU module - 200MHz CPU clock (ATMEL AT91SAM9263 ) - 64MB SDRAM - 256MB Flash - 8GB Micro-SD Operative system: - Linux (Kernel 2.6.28) Segnaling: 12 LEDs - Power line active (green) - Backup battery operating (yellow) - Ethernet (orange) - Tx/Rx channel 1 (2 orange) - Tx/Rx channel 2 (2 orange) - Tx/Rx channel 3 (2 orange) - User 1 and 2 (red and green) Push buttons: - 1 reset - 1 wake up - 1 switch off Housing: - Desktop housing - Black - LxPxA 167x110x53 mm Environmental characteristics: - Operating temperature: 0 C 50 C; - Storage temperature: -25 C 75 C.

3. : PIN IN/OUT Power connector Serial 0 Signal name Serial 1 Signal name Serial 2 Signal - 1-1 SER - 0 B - 1 SER - 1 B - 1 SER - 2 D - 2 SER - 0 A - 2 SER - 1 A - 2 SER - 2 C - 3-3 - 3 SER - 2 B - 4 Power - 4 Power - 4 SER - 2 A - 5-6 5V Power - 2 Power () - 3 Earth LED Function Colour Ethernet Signal Serial Debug Signal UART 2 RX - 1 TX - 1 UART 2 TX - 2 TX - 2 5 Vext UART 1 RX - 3 RX - 3 DEBUG-UART-RX UART 1 TX - 4 Not to be used - 4 DEBUG-UART-TX UART 0 RX - 5 Not to be used UART 0 TX - 6 RX ETH - LINK - 7 Not to be used DL11 USER 1 Green - 8 Not to be used DL10 USER 0 Red Battery ON Yellow ON line Green Push buttons Reset Wakeup Switch off 3.1 : GENERAL VIEW To turn on the Atlas connect the supplied power supply with the Atlas connector. To turn off the Atlas proceed as follow: Disconnect the main power supply of the Atlas: the LED with the battery icon turns ON (LED ) Hold the button on the back of Atlas until the red LED "R" on the front panel turns ON (LED DL10). As confirmation of the correct procedure wait for all the LEDs switching off. 6 5 Serial 2 Serial 1 Serial 0

4.1 MASTER: IP ADDRESS CONFIGURATION Connect the network cable between the PC and the connector Atlas (img 01) Set the PC's network adapter on the subnet 192.168.0.XX Use the Google Chrome internet browser at 192.168.0.184 Login with the following credentials: User: zero1 Password: zero1 Initialize the Atlas defining the name of the plant and the devices technology (CSF or RFID) img 01 PC From the "Environment Configuration" page to double click on "Main Controller" (img 02) Click Save Click Save Configuration From the page of "Environment Configuration" to double click on "Main Controller" img 02 Click Change Network Info and confirm with YES (img 03) img 03 Set the network adapter Atlas (img 04) Click "Save" and wait for the page "Environment Configuration" Click on "Save Configuration" to save the settings of the network card Atlas img 04 Ethernet cable

4.2 SLAVE: IP ADDRESS CONFIGURATION Connect the serial cable from Atlas terminal to a computer USB port (img 01) Download PuTTY free software from www.putty.org img 01 Serial cable Start up PuTTY program (img 02) In Serial line set up the COM door number assigned to the cable (COM12 in the example) In Speed set 115200 as the speed comunication In Connection type select Serial Click on Open (the Atlas dialogue window appears) Login with the following credentials: login = maint password = microhard img 02 Digit 1: change eth0 interface; (img 03) Press Enter and follow the instructions to set the device s IP address (default: 192.168.0.184) To exit and save digit 0 and press Enter img 03 PC

5. WARNINGS The calculation of the cables section must be performed by qualified staff. Max cable length of Lockbus channel is 100 mt. Recommended voltage for Lockbus channel: 24 VDC. In case of power failure the rechargeable batteries inside the Atlas ensure power for 30 minutes max. Ensure full recharge of the Atlas internal batteries by running a full recharge cycle min every 3 months (see section 8). It is advisable to provide for an appropriate sectioning and protection switch upstream of the transformer. The electrical connection must be made pursuant to the laws force. For any technical assistance or repairs, contact only Iseo Serrature or a technical assistance centre authorised by Iseo Zero1. Iseo Zero1 reserves the right to make all of modifications that the same deems recessary to the product and the instruction manual, without prior notice, in order to improve the quality or for manufacturing and marketing necessities. 6.1 SETTING TABLE WITH STYLOS READERS BUS ADDRESS Power supply 8/30 VDC - 2 W Note: for each Lockbus channel it s possible to connect max 8 Stylos readers. ADDRESS 1 = () VALIM ADDRESS 2 = Back side circuit view ADDRESS 3 = ADDRESS 4 = ADDRESS 5 = J2. J2. J2. J2. 1 2 3 4 ADDRESS 6 = ADDRESS 7 = } ADDRESS 8 = 1.2.3 JP2 J2. J2. J2. J2. 1 2 3 4 1.2.3 JP2 BUS ADDRESS 6.2 SETTING TABLE WITH STYLOS LINE SERIES ACTUATOR 3 4 5 6 7 8 () VALIM V PWR JP1 VCC Note: for each Lockbus channel it s possible to connect max 8 Lockbus actuators. I/O 1 I/O 2 IN AN LRL EARTH JP 3 LPW JP3 JP 2 JP1 P2 L2 2 L1 1 JP1 LCH JP2 BUS ADDRESS V2 Output P1 Power supply 8/30 VDC - 3 W LVO JP1 V1 Output NO/NC COM 6.3 SETTING TABLE WITH THESIS 2.0 S ACTUATOR Note: Take off the label to enter into configuration jumpers (JP1 / 2 / 3 / 4). After the operation replace the label. Power supply 8/30 VDC - 15 W () V ALIM 12345678 JP4 JP3 JP2 JP1 BUS ADDRESS JP 4 JP 3 JP 2 1 2 3 4 5 6 7 8 Note: for each Lockbus channel it s possible to connect max 8 Lockbus actuators.

7.1 : RFID PLANT - CONNECTION EXAMPLE (POWER SUPPLY SUPPLIED) 6 5 Note: in this example the lockbus channel maximum load is 24V DC - 25 W 24 VDC - 1,65 A L power supply 12/24 VDC - 10 W.1 = POSITIVE.2 = NEGATIVE () () V ALIM () V ALIM 7.2 : RFID PLANT - CONNECTION EXAMPLE ( POWER SUPPLY) 6 5 Note: size the power supply by calculating the consumption of all connected devices. () V ALIM 12/24 VDC L power supply 12/24 VDC - 10 W.1 = POSITIVE.2 = NEGATIVE () () V ALIM

7.3 : RFID PLANT - CONNECTION EXAMPLE (WITH 2 SEPARATED POWER SUPPLIES) 6 5 24 VDC - 1,65 A Note: size the power supply by calculating the consumption of all connected devices. 12/24 VDC power supply 12/24 VDC - 10 W.1 = POSITIVE.2 = NEGATIVE () L () V ALIM () V ALIM 7.4 : F9000 PLANT - CONNECTION EXAMPLE (POWER SUPPLY SUPPLIED) 6 5 24 VDC - 1,65 A power supply 12/24 VDC - 10 W.1 = POSITIVE.2 = NEGATIVE () RS 485 DI VPWR A lock -T D B A - RS 485 DI VPWR A lock -T CSF 9000 validator D B A CSF 9000 validator

7.5 : EXAMPLE OF CONNECTION OF A CSF VALIDATOR THROUGH AN ETHERNET CABLE CATEGORY 5E AND OVER Refer to section 7.4 to connect the main power supply to the Atlas Connect a resistance value of 120 ohm in parallel between pins A and B of the connector only on the CSF validator side Connect the shield of the cable to only on the Atlas side in PIN 3 of terminal side terminal = Pin 1 (B): white/blue wire (wires of the same twisted pair) Pin 2 (A): blue wire Pin 3 (- ): shield of the ethernet cable orange and orange/white wires (twisted pair) Pin 4 (): brown and brown/white wires (twisted pair) CSF validator side = - (T): orange and orange/white wires (twisted pair) : brown and brown/white wires (twisted pair) A: white/blue wire (wires of the same twisted pair) B: blue wire } terminal } Cable category 5E and over CSF 9000 validator R 120 OHM B 1 A 2 - () 3 D B A 4-8. MAINTENANCE: INTERNAL BATTERY CHARGING Important: the charging cycle of the internal batteries should be performed if you have an Atlas not powered for long periods of time. In this case it is mandatory to fully charge the internal batteries at least every 3 months max. Failure to observe this warning will destroy the internal rechargeable batteries. To perform a complete cycle of charging the Atlas internal batteries proceed as follows: Power on the Atlas and keep it powered for 24 consecutive hours. At the end of the 24 hours charging cycle power off the Atlas: the LED with the battery icon turns ON (LED ) Hold the button on the back of Atlas until the red LED "R" on the front panel turns ON (LED DL10). As confirmation of the correct procedure wait for all the LEDs switching off. Note the date of the last battery charge cycle to perform a new charging cycle within 3 months max. w w w. i s e o. c o m ELECTRONIC SUPPORT SERVICE www.iseozero1.com Non contractual document. Subject to change. Documento non contrattuale. Con riserva di modifica. Atlas installation manual GB 07/03/2016 Atlas