AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide

Similar documents
Multipathing Configuration for Software iscsi Using Port Binding

Connect P300H with iscsi initiator in ESX4.0

Open-E DSS V6 MPIO with VMware ESX 4.0

StarWind Virtual SAN Hyperconverged 3-node Scenario with VMware vsphere 6.5

Qsan Document - White Paper. How to configure iscsi initiator in ESXi 6.x

DELL POWERVAULT MD32XXI / MD36XXI DEPLOYMENT GUIDE FOR VMWARE ESX4.1 SERVER SOFTWARE

#1 HyperConverged Appliance for SMB and ROBO. StarWind Virtual SAN. Hyper-Converged 2 Nodes Scenario with VMware vsphere NOVEMBER 2016 TECHNICAL PAPER

Connect array to Cisco UCS and VMware vsphere

DELL POWERVAULT MD3200I / MD3600I DEPLOYMENT GUIDE FOR VMWARE ESX4.1 SERVER SOFTWARE

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.0 APRIL 2018 TECHNICAL PAPER

Best Practices for Sharing an iscsi SAN Infrastructure with Dell PS Series and SC Series Storage using VMware vsphere Hosts

VMware vsphere with ESX 4.1 and vcenter 4.1

One Stop Virtualization Shop. StarWind Virtual SAN. Hyperconverged 2-Node Scenario with VMware vsphere 6.5 MARCH 2019 TECHNICAL PAPER

Configuring and Managing Virtual Storage

EMC Performance Optimization for VMware Enabled by EMC PowerPath/VE

Nimble Storage SmartStack Getting Started Guide Cisco UCS and VMware ESXi5

StarWind Virtual SAN 2-Node Stretched Cluster on VMware vsphere 6.5

DSI Optimized Backup & Deduplication for VTL Installation & User Guide

EMC Unity Family EMC Unity All Flash, EMC Unity Hybrid, EMC UnityVSA

Deploy the ExtraHop Discover Appliance with VMware

Best Practices for Implementing VMware vsphere in a Dell PS Series Storage Environment

Using a Virtual Machine for Cisco IPICS on a Cisco UCS C-Series Server

10GbE Network Configuration

Configure iscsi on VMware using QSAN XCubeNAS

Preparing Virtual Machines for Cisco APIC-EM

Configuration Cheat Sheet for the New vsphere Web Client

Preparing Virtual Machines for Cisco APIC-EM

Dell TM PowerVault TM Configuration Guide for VMware ESX/ESXi 3.5

Vmware VCP-511. VMware Certified Professional on vsphere 5 (Private Beta) Download Full Version :

Deploy the ExtraHop Discover Appliance with VMware

Configuring High Availability for VMware vcenter in RMS All-In-One Setup

HiveManager Virtual Appliance QuickStart

Configure RSPAN with VMware

Deploying the LANGuardian Virtual Appliance on VMware ESXi 6.5

Configure RSPAN with VMware

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise

Basic Configuration Installation Guide

HP StoreVirtual Storage Multipathing Deployment Guide

Deploy the ExtraHop Trace Appliance with VMware

VMware vsphere Administration Training. Course Content

VMware vsphere with ESX 4 and vcenter

FUJITSU Storage ETERNUS AF series and ETERNUS DX S4/S3 series

Basic Configuration Installation Guide

Cisco Nexus 1000V Installation and Upgrade Guide, Release 5.2(1)SV3(1.4)

VMware ESX ESXi and vsphere. Installation Guide

StarWind Virtual SAN for vsphere Software RAID Configuration Guide

Setup for Failover Clustering and Microsoft Cluster Service

Setting Up Cisco Prime LMS for High Availability, Live Migration, and Storage VMotion Using VMware

Installing the Cisco IOS XRv 9000 Router in VMware ESXi Environments

VMware vsphere 5.5 Advanced Administration

vsphere Host Profiles Update 1 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

Emulator Virtual Appliance Installation and Configuration Guide

Managing Virtual Machines

vsphere Networking Update 2 VMware vsphere 5.5 VMware ESXi 5.5 vcenter Server 5.5 EN

Creating a New SBC SWe VM Instance

Deploying Microsoft Exchange Server 2016 on Dell EMC XC Series using iscsi

iscsi Configuration for ESXi using VSC Express Guide

By the end of the class, attendees will have learned the skills, and best practices of virtualization. Attendees

Virtualization with VMware ESX and VirtualCenter SMB to Enterprise

BIG-IP Virtual Edition and VMware ESXi: Setup. Version 12.1

Disclaimer This presentation may contain product features that are currently under development. This overview of new technology represents no commitme

2014 VMware Inc. All rights reserved.

Installing VMware vsphere 5.1 Components

Data Migration from Dell PS Series or PowerVault MD3 to Dell EMC SC Series Storage using Thin Import

StoneFly SCVM Deployment Guide for VMware ESXi

"Charting the Course... VMware vsphere 6.7 Boot Camp. Course Summary

CounterACT VMware vsphere Plugin

PASS4TEST 専門 IT 認証試験問題集提供者

vsphere Storage Update 1 Modified 16 JAN 2018 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

Overview. Prerequisites. VMware vsphere 6.5 Optimize, Upgrade, Troubleshoot

Deploying VMware View in the Enterprise EMC Celerra NS-120. Reference Architecture.

Best Practices For Running VMware vsphere On iscsi December 15, 2017

Installation of Cisco Business Edition 6000H/M

KEMP360 Central - VMware vsphere. KEMP360 Central using VMware vsphere. Installation Guide

Administering VMware vsphere and vcenter 5

VMware vsphere with ESX 6 and vcenter 6

vsphere Host Profiles 17 APR 2018 VMware vsphere 6.7 VMware ESXi 6.7 vcenter Server 6.7

VMware vsphere 6.5 Boot Camp

If you re not using VMware vsphere Client 5.1, your screens may vary.

Exam4Tests. Latest exam questions & answers help you to pass IT exam test easily

Preparing the boot media/installer with the ISO file:

Hitachi WAN Optimizer VMware vsphere Setup Guide

ForeScout CounterACT. Plugin. Configuration Guide. Version 2.1

LiveNX 7.4 QUICK START GUIDE (QSG) LiveAction, Inc WEST BAYSHORE ROAD PALO ALTO, CA LIVEACTION, INC.

HYPER-UNIFIED STORAGE. Nexsan Unity

Virtual Appliance Installation Guide

Managing Virtual Machines Using the Cisco SRE-V CLI

If you re not using VMware vsphere Client 4.1, your screens may vary. ITEM Example s Values Your Values

Surveillance Dell EMC Storage with FLIR Latitude

vsphere Networking Update 1 Modified on 04 OCT 2017 VMware vsphere 6.5 VMware ESXi 6.5 vcenter Server 6.5

Nutanix Community Edition ON VMWARE ESXI 6.0. Name Date

E V A L U A T O R ' S G U I D E. VMware vsphere 4 Evaluator s Guide

NetApp HCI Network Setup Guide

VMware vsphere 5.5 VXLAN Networking and Emulex OneConnect OCe14000 Ethernet Adapters

Logical Operations Certified Virtualization Professional (CVP) VMware vsphere 6.0 Level 1 Exam CVP1-110

VI3 to vsphere 4.0 Upgrade and New Technology Ultimate Bootcamp

vsphere Networking 17 APR 2018 VMware vsphere 6.7 VMware ESXi 6.7 vcenter Server 6.7

Vmware Certkiller VCP-410 Exam Bundle

StarWind iscsi SAN Software: Using an existing SAN for configuring High Availability with VMWare vsphere and ESX server

VMware vsphere: What s New Lab Manual ESXi 5.5 and vcenter Server 5.5

Transcription:

AccelStor All-Flash Array VMWare ESXi 6.0 iscsi Multipath Configuration Guide 1

Table of Contents Introduction... 3 Prerequisites... 3 Hardware Configurations... 4 Storage... 4 VMWare ESXi Server... 4 Additional Equipments... 4 Software Configurations... 4 VMWare ESXi Server... 4 VMWare vsphere Client... 4 Physical and Logical Topologies... 5 Storage Configurations... 6 ESXi Configurations... 7 Optimizing Round Robin Policy... 20 Guest OS Configurations... 22 2

Introduction This document provides a quick and simple guide for the basic storage and networking configurations of a VMWare ESXi server and how to attach an AccelStor iscsi storage appliance. This guide will provide examples of iscsi configurations on a NeoSapphire 3405. Essential iscsi storage performance and basic path redundancy can be achieved by following and successfully completing the setup steps in this guide. Prerequisites This document is prepared and released by AccelStor technical support team, in order to assist customers in setting and configuring a AccelStor iscsi AFA product. Readers of this document are suggested to have: Essential network configurations knowledge Basic familiarity with iscsi storage concept Basic familiarity with VMWare vsphere client console interface. For AccelStor partners who require additional assistance in configuring and demonstrating storage virtualization with AccelStor AFA products, please contact AccelStor for more details. 3

Hardware Configurations Storage Model: NS3405 Image version: 1.1.0 (build 3485) SSD Configuration: 3MG2-P SSD (880GB) x 10 Thin Provisioning Ratio: 1X VMWare ESXi Server CPU: Intel Xeon E5-2667 v4 @ 3.2GHz Memory: 64GB DDR4 2400 VMWare version: VMWare ESXi 6.0.0 (Build 3380124) 10GbE HBA: Intel X520-2 (10G ports x 2) Additional Equipments SuperMicro 24 ports 10GbE switch Software Configurations VMWare ESXi Server ESXi version 6.0.0 (VMKernel Release build 3380124) VM guest OS: Windows 2012 R2 build 9600 VMWare vsphere Client vsphere Client version 6.0.0 (Build 3249451) 4

Physical and Logical Topologies Notice: The above diagram illustrates a full view of both the physical networking deployment and a logical view of iscsi relative entities. You can use this as a reference structure for deploying a system with dual data ports connecting to the storage (i.e. 2x 10Gb ports) connecting to dual data ports on the ESXi server. If the number of data ports increases, complexity of the topology will increase respectively and the obtained result may vary according to changes in the configurations. 5

Storage Configurations 1. Configure IP addresses of the data ports to be connected to the ESXi server. 2. Create a volume with required capacity. 3. Create multiple iscsi targets for the same LUN (volume) for multi-path connections between the ESXi server and the storage. (In this practice 4 iscsi targets are created and mounted to each volume for iscsi performance enhancement via multiple paths.) 4. In the iscsi targets options, leave the portal options empty. By default when this option is left empty for an iscsi target, all targets are discoverable on all data ports on the storage. However, you may manually configure this option to only allow the iscsi targets to be discoverable on specific data ports. 5. Repeat steps 1~4 for all volumes to be mounted onto ESXi servers as datastores. 6

ESXi Configurations Tasks: a. Add and configure the Software iscsi initiator. b. Create a new virtual switch and vmkernel ports for iscsi traffic. c. Optimize vswitch settings for iscsi traffic. d. Configure vmkernel port bindings for iscsi traffic. e. Configure iscsi targets discovery. f. Adjust multipath policy to optimize performance. Step by Step Configurations: 1. In the inventory, click on the ESXi server and switch to Configuration tab. 2. Click on Storage Adapters and click on Add. Then select Add Software iscsi Adapter and click OK. 3. In the inventory panel, switch to Networking, and click on Add Networking 7

4. Select VMKernel, and click on Next to continue. 5. Select ALL the 10G interfaces to be used for outgoing iscsi connections from the ESXi server. Click on Next to continue. 8

6. Modify the Network Label Name if required, and click Next. 7. Assign a pre-allocated static IP address to the VMkernel port for communicating to one of the 10G data port IP addresses on the storage. Click Next to continue. 9

(In this practice, two 10G ports are to be configured for iscsi connections, so configure the first VMkernel port to the same subnet as one of the 10G ports on the storage.) 8. Click Finish to complete the settings. 10

9. Click on Properties of the new created vswitch. 10. Click Add to add the 2 nd VMKernel for iscsi. (If you need to configure more ports for iscsi connections, create a corresponding amount of VMKernel ports accordingly. For example, 4 VMKernel ports for 4 physical vmnic uplinks) 11. Repeat previous steps 4~8 to complete the settings for additional VMKernel ports. The completed topology should include a matching number of VMKernel ports to the number of Physical Adapters (vmnic uplinks). 11

12. Click on the Properties of the vswitch again, select one of the VMKernel port and click on Edit to adjust settings of the VMKernel port. 13. In the General Tab, adjust the MTU to 9000. 12

14. Switch to the NIC Teaming tab, check the Override switch failover order. Move down the Physical vmnics in the list to leave only one vmnic in the Active Adapters section. (Notice: Assign a different active vmnic to each VMKernel port here) 15. Repeat the above steps (12~14) for the other VMKernel port. 13

16. In the vswitch ports view panel, select the vswitch and click on Edit. 17. Adjust the MTU of the vswitch to 9000, and click on OK. 18. In the Inventory view, switch back to Storage Adapters. 19. Right click on the iscsi Software Adapter vmhba37 and select Properties. 20. In the Properties panel, switch to Network Configuration tab, and click Add under the VMKernel Port Bindings list. (This step builds up bindings between the VMKernel and the VMKernel ports for iscsi discovery and connections.). 21. Select and add both 10G ports to use for iscsi connections in this practice. (If in your case there are more than two ports, select all of them). 14

22. Make sure all VMKernel ports in the new vswitch have kernel port bindings configured properly. Close the Properties. 15

23. In the iscsi initiator Properties panel, switch to the Dynamic Discovery tab. At this point both (or all) data ports on the storage should be visible and discoverable to the ESXi iscsi initiator. Click Add and enter the IP addresses of the data ports to be discovered. Close the iscsi initiator after all portal IP addresses have been entered. 24. Click on Yes when being prompted for a rescan. 25. A successful completion of the above steps should then bring out a list of discovered and connected iscsi disk devices (LUNs) in the Devices list. 16

26. Manual adjustment of the multipath policy is required for each device. Right click on any of the devices in the list and select Manage Paths. 27. In the dropdown menu, select Round Robin (VMware) and click on Change. 17

All path status will become Active (I/O) after the change becomes effective. 28. A list of all paths connected to all devices can be checked under the Paths view. In this practice, there are two volumes configured on the storage, for each 18

datastore there are 16 paths (2 ports x 2 paths x 4 targets = 16). 29. In the Inventory, switch to Storage, upon successful of the above steps, the new iscsi datastore appear in the list. 19

Optimizing Round Robin Policy By default VMware uses Most Recently Used pathing policy for all configured iscsi datastores. Although in this practice we adjusted the policy to round robin to achieve better performance, for an optimized result the settings need to be further fine-tuned. By adjusting an advanced parameter within the VMware round robin PSP, it is possible to further define when I/Os happen, how frequently the round robin policy switches between different logical paths to a specific device. The default setting of the VMware round robin policy switches between different I/O paths with every 1000 I/Os, which usually results in unbalanced I/O loadings between the paths and impacts the overall performance. For an optimal performance and a faster failover speed in a case of failure, it is recommended to adjust this setting to switching between paths immediately with every I/O. This I/O setting can only be adjusted with esxcli command. The ID of the target datastore needs to be identified first: 20

And then the advanced settings of the datastore can be adjusted using the following command in ESXi SSH CLI: esxcli storage nmp psp roundrobin deviceconfig set --device eui.34074f4dbc4042e9 -I 1 -t iops Modified settings can be verified using the following command: esxcli storage nmp psp roundrobin deviceconfig get --device eui.34074f4dbc4042e9 In the displayed result, make sure the IOOperation Limit value has been changed to 1 and the Limit Type is set to Iops. Rebooting the ESXi server might be required for this setting to take effect in some cases. Effective settings of a specific device can be verified with the following command, and completes the iops limitation settings adjustment in this section. esxcli storage nmp device list -d eui.34074f4dbc4042e9 21

Guest OS Configurations With the iscsi volume successfully connected and mounted on the ESXi server as a datastore, the storage space can start to be configured for accesses from guest VMs. 1. In the vsphere client panel, expand the VM list at the left, and right click on the target VM, select Edit Settings. 2. In the VM Properties window, under the Hardware tab, click Add. 3. Select Hard Disk, and click Next. 4. Select Create a new virtual disk and click Next. 22

5. Adjust the Capacity of the virtual disk to required size, and select Thick Provision Eager Zeroed for Disk Provisioning type to obtain optimal performance. In the Location option, click Browse and select to the iscsi datastore configured in the previous sections of this guide, then click OK. Click Next to continue. 23

6. Leave all Advanced Options as default and click Next to continue. 7. Click Finish to complete and virtual disk settings, and click OK to end the configuration. 8. A noticeable progress bar then appears in the recent task list in the vsphere client console; wait for all virtual disk configuration tasks to complete. 24

9. The virtual disk can now be accessed from the guest OS as a new disk device. 25