MI1000ERW. Series. Miniature 1 x 1, 2:1 Input, 10W DC/DC Con vert ers. Key Features:

Similar documents
MB2000ERUI. High Isolation, 1 x 2 20W, 4:1 Input Range DC/DC Con vert ers. Key Features:

IG480RW. Series. High Isolation IGBT Driver DC/DC Con vert ers.

MPV1060RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

MPV1560RI4. Ultra Wide Input, Compact Industrial Grade, PV Power DC/DC Con vert ers. Key Features:

ML100SRI. Series. Ultra-Miniature, 1W High Isolation, SMT DC/DC Con vert ers. Key Features:

MPO-120S Series. Single Output, 180W Compact, Open Frame AC/DC Power Supplies. Key Features:

MPU-120S Series. Single Output, 180W Compact, U-Channel AC/DC Power Supplies. Key Features:

20W DC-DC Converter P20J-Series

20W DC-DC Converter P20H-Series

Series AM20EW-NZ 20 Watt DC-DC Converter

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 88% Over Current and Over Voltage Protection No Minimum Load Required

Series AME10-VZ 10 Watt AC-DC / DC-DC Converter

Efficiency (typ.) Load VDC VDC ma ma(typ.) ma(typ.) μf %

POWERBOX Industrial Line PMR20W Series 20W 4:1 Single and Dual Output High Performance DC/DC Converter

C B. Models. Ultra wide 4:1 input voltage 20 W DC/DC. edition and EN55032 class A

Series AM1M-NZ 1 Watt DC-DC Converter

Series AME25-JZ 25 Watt AC-DC / DC-DC Converter

TEP160-WIRCM SERIES 160 Watt High Density Brick DC-DC Converter Measures: 2.40 x 2.28 x 0.50

DC-DC CONVERTERS SINGLE OUTPUT, 60 WATTS EXTREMELY WIDE 12:1 INPUT VOLTAGE RANGE: 9-75VDC, VDC RAILWAY APPLICATIONS

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 87% Fixed Operating Frequency Six-Sided Continuous Shield

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 84% Fixed Operating Frequency Six-Sided Continuous Shield

FDC20-48 S 05 W - HC PART NUMBER STRUCTURE Page 1. P-DUKE Technology Co., Ltd.

TEP 100WIR Series, 100 Watt

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

TEP 75WI Series, 75 Watt

Package (4) Control Logic (3)

C B. Models. Operating up to 5000m altitude 5 year product warranty

FEATURES. Nominal Output Voltage and Current

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

AC/DC Converter SLD05-20Bxx Series

Efficiency (typ.) (Range) VDC VDC ma ma(typ.) ma (typ.) ma(typ.) VDC μf % MKW15-12S05M. Output Current Input Current Reflected Ripple

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

4:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 89% Six-Sided Continuous Shield

12-15VDC (12V±5%) 24-28VDC (24V±5%)

Series AM3G-NZ 3 Watt DC-DC Converter

Series AM1S-Z 1 Watt DC-DC Converter

Series AMEL20-AZ 20 Watt AC-DC / DC-DC Converter

Features. Regulated Converters. RP10-AW 10 Watt 1 x1 Single & Dual Output RP10- _AW/_- DC/DC Converter

APM-40 SERIES FEATURES PRODUCT OVERVIEW. Model Selection Guide. Input Specifications. AC/DC Power Module 40W, Industrial & Medical Safety

2:1 Input Voltage Range 2.25kVDC Isolation UL Certified Efficiency up to 88% Ultraminiature Open Frame SMD No Minimum Load Required

Application Package Dimension Output Input Output Output Protection Option Code Code Power Voltage Quantity Voltage Type (W) (VAC) (VDC)

2:1 Wide Input Voltage Range 1.6kVDC Isolation UL Certified Efficiency up to 90% Six-Sided Continuous Shield Available as Power Module (RPM40-G)

Series AME60-MJZ 60 Watt AC-DC / DC-DC Converter

Series AME5-CJZ 5 Watt AC-DC / DC-DC Converter

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

PXC05-Dual Output Series: DC/DC Converter Module 9 to 75 Vdc input, 3.3 to 15 Vdc Dual Outputs, 5W

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

Ripple & Noise (max) (See Note 2) 5V output: 100mVp-p; 12V - 27V outputs: 150mVp-p; 48V output: 200mVp-p

Series AMES40-MAZ 40 Watt AC-DC / DC-DC Converter

1W & 2W Wide Input Range DC/DC CONVERTERS. Features

Packaging (4) Isolation Voltage (3) nom. Output Voltage

VP ELECTRONIQUE MASSY - Tel

PART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1

12-15VDC (12V±5%) 24-28VDC (24V±5%)

DC/DC Converter E_S-1WR2 & F_S-1WR2 series

Series AM4T-Z 4 Watt DC-DC Converter

Series AMEL5-MAZ 5 Watt AC-DC / DC-DC Converter

Series AMEL20-MAZ 20 Watt AC-DC / DC-DC Converter

PT SERIES SIP Package

PXC-M06xxW Dual Output Series: DC-DC Converter Module 9 ~ 36 VDC and 18~ 75 VDC input; ±5 to ±15 VDC Dual Output 6 Watts Output Power

MPM-U653-DCF-B M/N: MPM-U653-DCF-B. 650W Medical AC / DC SPECIFICATION FOR SWITCHING POWER SUPPLY. Revision History

MMA-15 series. 15W Medical Grade Ultraminiature Switching Power Supplies. Single / Dual / Triple Outputs. Universal 90 to 264VAC Input

Model No. ( Single Output ) ATC-3.3S ATC-5S ATC-12S ATC-15S ATC-24S Max Output Wattage (W) 10W 10W 10W 10W 10W VAC or VDC

TMP & TMPM Series, 4 to 60 Watt. Order code Output power max. Output Efficiency

Output Current Input Current Max. capacitive Load

Parameter Condition Min. Typ. Max. Internal Input Filter. nom. Vin = 230VDC 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

Series AMER120-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Features. Regulated Converter. RAC35-G/OF 35 Watt 4 x 2 Open Frame RAC35- SG/OF. AC/DC Converter

Packaging (5) Protection (3) Isolation Voltage (4)

RM- S/_ Protection (3) Isolation Option (4) Single

Series Specifications Ta= 25 C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Condition Min. Typ. Max.

RS2/RD2-E10/T10. RoHS. 1.0W Unregulated Dual Separate Output

Universal Power Supplies

Output Voltage* (nom.)(adjustable)

IEC/EN/UL60950 & CE certified, EN55032 Class B

Note1: Typ. efficiency is 230VAC and full load 12VDC 24VDC 48VDC ms 8ms 16ms 80ms

Parameter Condition Min. Typ. Max. Internal Input Filter 115VAC 230VAC 115VAC 230VAC. No load Power Consumption

DDR-120 series. 120W DIN Rail Type DC-DC Converter

DPX15W Rated Input voltage range 24V nominal input VDC 48V nominal input 18-75VDC. Input Fuse 24V input, 6A Fuse 48V input, 4A fuse

RO- S/_ Protection (3) Isolation Option (4) Single

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V

Enclosed Power Supplies

Datasheet. ACF-10 Series AC/DC Power Module 10W

Protection (3) alternative Pinning Option (4) Single or Dual

PT/PS SERIES SIP/SMD Package

Snaptec Australia Pty. Ltd.

Output Voltage* (nom.)(adjustable)

Universal input VAC <150mW No load power consumption

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

DC/DC Converters. TSM Series, 1 Watt. Features. Models

DDR-120 series. 120W DIN Rail Type DC-DC Converter

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY. Revision History

FS60 Series small size isolated AC/DC converters

Notes: Note1: Other output voltages on request Note2: Efficiency is tested at nominal input (115/230VAC) and full load at +25 C ambient

Switching Power Supplies

Universal input VAC <250mW No load power consumption -25 C to +80 C Operating temperature, with derating

Industrial Power Supplies

efo Series Wide range AC/DC Single Output 1000W Rugged Power Supply Electrical Specification for: Telkoor Part Number:

SPECIFICATION M/N: MPD-F For SWITCHING POWER SUPPLY

Series AMEPR60C-AZ up to 5A AC-DC / DC-DC LED Driver / Converter

Transcription:

MI1000ERW Miniature 1 x 1, 2:1 Input, 10W DC/DC Con vert ers Key Features: 10W Output Power 2:1 Input Voltage Range Miniature 1 x 1 Case 1,500 VDC Isolation Meets CISPR 32/EN 55032 Remote On/Off Control -40 C to +85 C Operation Industry Standard Pin-Out Chassis & DIN Rail Mount MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: Series Electrical Specifications Specifi cations typical @ +25 C, nominal input voltage & rated output current, unless otherwise noted. Specifi cations subject to change without notice. Input 12 VDC Input 9.0 12.0 18.0 Input Voltage Range 24 VDC Input 18.0 24.0 36.0 VDC 48 VDC Input 36.0 48.0 75.0 12 VDC Input 9.0 Input Start Voltage 24 VDC Input 18.0 VDC 48 VDC Input 36.0 12 VDC Input 5.5 6.5 Input Under Voltage Protection 24 VDC Input 12.0 15.5 VDC 48 VDC Input 26.0 30.0 Reflected Ripple Current 20 ma Input Filter Pi ( ) Filter Output Output Voltage Accuracy IOUT = 0% to 100% ±1.0 ±3.0 % Line Regulation VIN = Min to Max ±0.2 ±0.5 % Load Regulation IOUT = 5% to 100% 12 & 48V Inputs ±0.5 ±1.0 IOUT = 0% to 100% 24V Input ±0.5 ±1.0 % Cross Regulation See Note 2 ±5.0 % Ripple & Noise (20 MHz) See Note 3 40 100 mv P - P Transient Recovery Time 300 500 µsec Transient Response Deviation See Note 4 3.3 & 5 VOUT Models ±5.0 ±8.0 All Other Models ±3.0 ±5.0 % Temperature Coefficient ±0.03 %/ C Output Over Voltage Protection 110 160 %VOUT Output Over Current Protection 110 140 190 %IOUT Output Short Circuit Continuous (Autorecovery) General Isolation Voltage 60 Seconds 1,500 VDC Isolation Resistance 500 VDC 1,000 M Isolation Capacitance Input/Output 100 KHz/0.1V 1,000 pf Switching Frequency 350 khz Environmental Operating Temperature Range Ambient -40 +25 +85 C Storage Temperature Range -55 +125 C Cooling Free Air Convection Humidity RH, Non-condensing 95 % Physical Case Size,Module, Chassis /DIN Rail Mount See Mechanical Drawings (Starting Page 4) Case Material Aluminum (UL94-V0) Weight, Module, Chassis /DIN Rail Mount See Mechanical Drawings (Starting Page 4) Remote On/Off Unit On 3.5 12.0 VDC See Note 5 Unit Off 0 1.2 VDC Off Idle Current 6.0 10.0 ma Reliability Specifications MTBF MIL HDBK 217F, 25 C, Gnd Benign 1.0 MHours Vibration 10-55 Hz, 10G, 7.5 mm, 30 Min along X, Y & Z Axis Absolute Maximum Ratings 12 VDC Input 25.0 Input Voltage Surge (1 Sec) 24 VDC Input 50.0 VDC 48 VDC Input 100.0 Lead Temperature 1.5 mm From Case for 10 Sec 300 C Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.

Model Selection Guide Model Number Voltage (VDC) Input Current (ma) Nominal Range Full-Load No-Load Voltage (VDC) Output Current (ma, Max) Current (ma, Min) Efficiency (%, Typ) Capacitive Load (µf, Max) Certification Fuse Rating Slow-Blow (ma) MI1012S-05ERW 12 9.0-18.0 1,004 5 5.0 2,000 0.0 83 2,200 --- 2,000 MI1024S-05ERW 24 18.0-36.0 502 5 5.0 2,000 0.0 83 2,200 CE 1,000 MI1024S-12ERW 24 18.0-36.0 479 5 12.0 833 0.0 87 470 CE 1,000 MI1024S-15ERW 24 18.0-36.0 473 5 15.0 667 0.0 88 330 CE 1,000 MI1024S-24ERW 24 18.0-36.0 473 5 24.0 416 0.0 88 100 CE 1,000 MI1048S-03ERW 48 36.0-75.0 263 4 3.3 2,400 0.0 79 2,200 --- 500 MI1048S-05ERW 48 36.0-75.0 251 4 5.0 2,000 0.0 83 2,200 --- 500 MI1048S-12ERW 48 36.0-75.0 239 4 12.0 833 0.0 87 470 --- 500 MI1048S-15ERW 48 36.0-75.0 239 4 15.0 667 0.0 87 330 --- 500 MI1048S-24ERW 48 36.0-75.0 237 4 24.0 416 0.0 88 100 --- 500 For the A2S adapter board option, add suffix A2S to the model no. (i.e. MI1024S-05ERW-A2S) Efficiency Curves: Efficiency vs Input Voltage MI1024S-05ERW (24 VIN - 5 VOUT) For the A4S adapter board option, add suffix A4S to the model no. (i.e. MI1048S-12ERW-A4S) 1. The specifi ed maximum capacitive load is for each output. 2. Cross regulation is measured on dual output models with one output at 50% load while the other output is varied from 10% load to 100% load. 3. When measuring output ripple & noise, it is recommended that an external capacitor (10 µf) be placed from the +VOUT to the -VOUT pins for single output units and from each output to common for dual output models. From 0% - 5% output load, ripple & noise is 5% max. 4. Transient recovery is measured to within a 1% error band for a load step change of 25%. 5. The voltage at the Remote On/Off pin (Pin 6) is referenced to the -VIN input (Pin 1). If the on/off pin is left open, the unit operates. If it is grounded, the unit will shut off. 6. Dual output units may be connected to provide a 10V, 24V, or 30 VDC output. To do this, connect the load across the positive (+Vout) and negative (-Vout) outputs and float the output common. 7. Operation at no-load will not damage these units. However, they may not meet all specifications. 8. It is recommended that a fuse be used on the input of a power supply for protection. See the Model Selection table above for the correct rating. Derating Curve Efficiency Curves: Efficiency vs Output Voltage MI1024S-05ERW (24 VIN - 5 VOUT) Page 2 We Power Your Success - For Less

EMI Characteristics Parameter Models Standard Criteria Level Class A (without external components) Radiated Emissions 12V & 24V Input CISPR 32/EN 55032 Class B (See Typical Connection below) (See Note 1) 48V Input Class B (See Typical Connection below) Class A (without external components) Conducted Emissions 12V & 24V Input CISPR 32/EN 55032 Class B (See Typical Connection below) (See Note 1) 48V Input Class B (See Typical Connection below) ESD EN 61000-4-2 B ±4 kv Contact RS EN 61000-4-3 A 10V/m EFT See Note 2 EN 61000-4-4 B ±2 kv Surge See Note 3 EN 61000-4-5 B ±2 kv CS EN 61000-4-6 A 3 Vrms Voltage Dips EN 61000-4-29 B 0% - 70% 1. If the application does not require that emmissions meet international standards, simply adding capacitors to the input and output circuits may be suffi cient to reduce ripple & noise. See note 5 below. 2. To meet the requirements of EN 61000-4-4, external components are needed. The connection diagrams below show an external input fi lter that would typically achieve this. Contact the factory for more information. 3. To meet the requirements of EN 61000-4-5, external components are needed. This can be done as shown in the connection diagrams below. Contact the factory for more information. Typical Connection: 12 VDC Input Models Typical Connection: 24/48 VDC Input Models For applications that require meeting EMC standards, the diagram above illustrates a typical connection of the MI1000xERW series. The units do not require external components to operate as specified. Some notes on this diagram (starting with the input circuit) are: 1. An external fuse should be used in all power module applications. The recommended fuse is shown in the model chart on page 2. 2. To protect against a surge, an external MOV is recommended on the input. A suggested value is given in the table at right. 3. All input/output filtering capacitors should have a low equivalent impedance. Any output capcitors used should be high frequency, low resistance electrolytic capacitors. Care must be taken in choosing this capacitor not to exceed the capacitive load specification for the unit. Voltage derating of all capacitors should be 60% or greater. 4. Recommended values for components are: Component 12 VIN 24 VIN 48 VIN MOV 20D470K S20K30 14D101K C1 330 µf/50v 680 µf/50v 680 µf/100v C2 1 µf/50v 1 µf/50v 1 µf/100v LCM --- 4.7 mh 4.7 mh LDM1 4.7 µh --- --- C3 --- 330 µf/50v 330 µf/100v C4 --- 4.7 µf/50v 4.7 µf/100v CY1 1 nf/2 kv 1 nf/2 kv 1 nf/2 kv CY2 1 nf/2 kv 1 nf/2 kv 1 nf/2 kv C5 10 µf 100 µf 100 µf 5. In many applications simply adding input/output capacitors will enhance the input surge protection and reduce output ripple suffi ciently. Suggested capacitor values are: Input Voltage 12 VIN 24 VIN 48 VIN CIN 100 µf 100 µf 100 µf COUT 10 µf 10 µf 10 µf MPD 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com

Mechanical Dimensions 1 -VIN 2 +VIN 3 +VOUT 4 No Pin 5 -VOUT 6 Remote On/Off Pin Section Tolerance x.xxx = ±0.004 (±0.100) General Tolerance x.xx = ±0.01 (±0.25) Weight: 0.49 Oz (14g) Mechanical Dimensions, A2S: With Chassis Mount & Power Good LED 1 Remote On/Off 2 -VIN 3 +VIN 4 -VOUT 5 No Connection 6 +VOUT General Dimension Tolerance x.xx = ±0.02 (±0.50) Wire Range: 12 to 24 AWG Tightening Torque: 0.4 Nm Max Weight: 1.26 Oz (36g) The LED indicates the output voltage is present (LED On ) Page 4 We Power Your Success - For Less

Mechanical Dimensions, A4S: With DIN Rail Mount Option & Power Good LED 1 Remote On/Off 2 -VIN 3 +VIN 4 -VOUT 5 No Connection 6 +VOUT General Dimension Tolerance x.xx = ±0.02 (±0.50) Wire Range: 12 to 24 AWG Tightening Torque: 0.4 Nm Max Weight: 6.66 Oz (190g) For use with a TS35 type DIN rail The LED indicates the output voltage is present (LED On ) Power Products MPD offers a wide variety of power conversion products. Over 5,000 standard AC/DC power supplies, DC/DC converters, LED Drivers, POL regulators and IGBT drivers. Our products are designed into a diverse variety of products/systems that include precision measurement equipment, renewable energy power systems; high speed/high power inverters; computer controlled lighting circuits and remote monitoring & control systems. All products are available with short lead times and full technical support is a phone call away. Call today for complete information or product samples. MicroPower Direct We Power Your Success - For Less! 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 FAX: (781) 344-8481 E-Mail: sales@micropowerdirect.com