SV Xchange. User Manual

Similar documents
P Xchange. User Manual

Version May Tu Xchange User Manual

Version February Minos X User Manual

UV Xchange User Manual

Version December Smart X User Manual

Version November Micro X User Manual

Version July Metrec X User Manual

Operation Manual MODEL 2TX. 2-wire Isolated ph/orp Transmitter

Section 1 - Mechanical Operation

Version 1.12 June 3, Base X User Manual

Bluelab ph Meter TM Instruction Manual

Version April Base X2 User Manual

Vibrating Wire Joint Meter Manual

User's Guide. ExStik EC400. Conductivity / TDS / Salinity / Temperature Meter MODE HOLD

Global Water Instrumentation, Inc.

Visit us at Back to the Extech DO600 Product Page

User Guide. ExStik II EC400. Conductivity / TDS / Salinity / Temperature Meter

TDS/SALT/TEMP TRACERTM POCKETESTER CODE 1749-KIT. Pool Professional s Meter

Removal and Installation8

Raptor Series Adapters

Butterfly Laser Diode Mount

WK7200. Water Quality Test Kit USER S MANUAL

There are two basic applications for the Ikelite DS Sensor. Add an External Strobe. Camera WITHOUT flash connection

OPERATION MANUAL MODEL TT-LP

Keysight M8000 Series BER Test Solutions

INSTRUCTION MANUAL HBPH DIFFERENTIAL 2-WIRE (4-20 ma) ph Sensor

User s Manual. March 30, 2010 P/N: Revision E TURNER DESIGNS 845 W. Maude Ave. Sunnyvale, CA Phone: (408) FAX: (408)

DO Meter Kit. Instruction Manual

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

Smart Multivariable Transmitter (SMV 3000) Electronics Module Replacement Kit Instruction

SV 277 Pro User Guide. Assembling the system. What's inside? Before you go on site

Operations Manual EcoSense ph100a

TD2100 Electric Gummed Tape Dispenser Owner s Manual

Encore XT Manual Gun Upgrade Kit

Sound Velocity & Temperature Smart Sensor. User's Manual

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

itech Training Courses iphone 5S LCD Assembly Replacement Guide

RESS. Manual. Rotary-Ball-Camera Pro. The Producer. Visual Inspection Sweep Instruments Measuring Instruments

For your safety! General information

RST INSTRUMENTS LTD.

Version 1.4 June 2018

F2A (M527) F2A (M506n/dn) F2A (M506x)

AquaController Apex Probe Module 2

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

BTU 4 & Sensors. Installation and Operation Manual

LINEAR ACTUATOR CONTROL Use with NEW LEADER 7 manual

Waterproof 3-Axis Gimbal Camera (GC3) Manual

Zebra-Tech UW-Calipers

Dell OptiPlex All-in-One. Stand Installation Guide

Frequency Output Depth and Pressure Transducers. Seismic Stuff Technology Pte. Ltd.

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

User's Guide. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500

Electronic Balance Ionizer STABLO-AP Service Manual

Thermo Scientific Orion Star A214 Benchtop ph/ise Meter. Instruction Sheet

SoilStik ph Meter PRODUCT MANUAL

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

Operating Instructions

Operating Instructions ACM-100 Aircraft Cable Tension Meter

DEPLOYMENT GUIDE OCEAN SURVEYOR/OBSERVER. P/N 95A (June 2018) 2018 Teledyne RD Instruments, Inc. All rights reserved.

WalkLAB HC Professional Conductivity-TDS-Salinity Meter. Operations Manual 15,0,11,4,1,14,5,10,13,2,9,6,3,12,7,8

SP-400 Portable Water Analyzer Operation Manual. Rev. A Firmware version 1.02

IR Varifocal IP66 Weatherproof Cameras

MODEL 245 / 345 DigiComp

E2460GS Oscilloscope Upgrade Kit

Replacing/Upgrading Mac Pro Processors (Early 2008)

Operations Manual EcoSense ph100

RS-FS-N01 Wind speed transmitter user's Guide (485type)

User Guide. ExStik FL700. Fluoride Meter

MULTIMETER: YSI-ProDSS rev. 9/23/15

6-Series Sonde Quick Start Guide

Seabird CTD Carousel Setup & Deck Unit Diagnostics

Introduction: Features:

If technical support is required, please contact Advent Technical Support at

ISP Tester. Operating Instructions

The Economy Conductivity Benchtop Meter

INSPECTION CAMERA MODEL NO: CIC2410 OPERATION & SAFETY INSTRUCTIONS PART NO: GC0116

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T.

Manual No: Revision: D. Mag Retrofit Probe. Installation Guide

Agilent ICP-OES SVS 2 Productivity Package Installation and Upgrade Instructions

HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions

IS R Fieldscopes User Instructions and 10 Year Guarantee

User Manual DOCUMENT #601119REF. EcoSense ph1000a. ph, mv (ORP), and Temperature Benchtop Meter USER MANUAL. English

Gateway Profile 4 service guide

MIC Advantech CompactPCI. Modular Industrial Computer. 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane

MTX-A, Fuel Pressure Gauge PSI

12-Bit 0-5 Volt Input Adapter (Part # S-VIA-CM14)

Operation Manual. Hand-held ph/orp/temperature Meter 6010M

HygroClip M22 Series. 2-wire loop powered humidity temperature transmitters INSTRUCTION MANUAL

FloBoss S600+ Field Upgrade Guide

4010-2/3 ph Adapter DIN / BNC

Field Handbook Supervision

Operation Manual. Hand-held ph/mv/temperature Meter. ph6810

User Manual. ExStik EC500. ph/conductivity / TDS / Salinity / Temperature Meter EC500. Additional User Manual Translations available at

UWL-400F Wide Angle Lens

User s Guide. RP7000S Series Single-Ended Active Probe. Nov RIGOL Technologies, Inc.

Model OI-6900-LEL Sensor Assembly

Operation Manual. MODEL ph/ec80. Microcomputer Based ph/condctivity/tds/ Sanility & Temperature Pocket Meter. ph/ec80

It s a Better Way to Weigh!

Owner s Manual. The Forward Compatible Video Housing for Sony Camcorders.

MM4 Travelscopes User Instructions and 30 Year Guarantee

Transcription:

SV Xchange User Manual Document Version 1.1 Dated 03 June 2009

Table of Contents Table of Contents... 1 General Description of the Sensor... 1 Which Manual do I Start With?... 1 Shipping and Receiving... 2 Receiving the Sensor... 2 Shipping the Sensor... 3 Using the SV Xchange... 3 Attaching the SV Xchange Sensor... 3 Removing the SV Xchange Sensor... 4 Pre-Deployment Procedures... 4 Post-Deployment Procedures... 4 Periodic Maintenance... 4 Inspecting & Replacing the O-ring... 5 SV Xchange Commands... 6 Talking to the SV Xchange Sensor... 6 Specific Commands of Interest... 6 Customer Support... 7 Troubleshooting... 7 AML Contact Info... 8 General Description of the Sensor The AML Oceanographic s SV Xchange sensor is the industry s only field swappable time-offlight sound velocity sensor. The SV Xchange sensors store all pertinent sensor manufacturing and calibration data within the sensor. This allows the sensor to be swapped between any SV Xchange enabled instruments without having to manually update the calibration coefficients. Calibration sheets can be printed on demand by any instrument connected to the SeaCast software. Recalibrations only require the sensor, not the instrument, to be shipped to the service centre. Which Manual do I Start With? AML Oceanographic s instruments may be shipped with several manuals: An instrument manual (ie. SV Plus v2, Micro SVT&P) which provides an overview on how to use and maintain the instrument; A software manual (ie. SeaCast) which provides instructions on how to use the software to configure the instrument and review instrument data; and Xchange sensor manuals (for those instruments that have been Xchange enabled) which provide an overview on how to install and maintain Xchange sensors. If you are configuring an instrument for field use or lab test, we recommend that you begin with the SeaCast manual. If you are focussed on instrument maintenance, we recommend that you 1

begin with the instrument manual. If you are wishing to swap an SV Xchange sensor, we recommend that you read this manual. Shipping and Receiving Receiving the Sensor When the sensor is received at a new location it is prudent to perform the following steps to ensure the sensor has not been damaged in transit: Check the shipping container for signs of damage Check for damage on the sensor itself o Check the sensor for cracks, dents or dirt. o Check the connector for corrosion or dirt Connect the sensor to an instrument. Connect the instrument to a computer using the data cable. Launch SeaCast, AML Oceanographic s application software. Verify that the instrument tab in SeaCast is displaying accurate SV Xchange sensor information. The SV Xchange sensor serial number and last calibration date should be displayed. Immerse the sensor (on the instrument) in fresh water. Ensure there are no bubbles on the sensor reflector or transducer face. Take a scan, the sound velocity output should agree with the graph below. 2

Shipping the Sensor If shipping for repair or recalibration, obtain an RMA number from the service centre. Please refer to page 8 for contact details. Pack the instrument in its original shipping box to prevent damage during shipping. Using the SV Xchange This section of the manual discusses how to attach and disconnect the SV Xchange sensor. This section also identifies pre-deployment and post-deployment procedures, as well as periodic maintenance requirements. Attaching the SV Xchange Sensor Ensure that the instrument socket is clean and dry Check the sensor s o-ring for cleanliness (see below, Inspecting & Replacing O-Rings) Align the sensor to the sensor mount Place the sensor into the mount Rotate the sensor until it drops down into the mount enough to allow the blue locking sleeve threads to engage the mount threads Screw down the blue locking sleeve until it stops. The bottom of the sleeve should be within 1 mm of the instrument end cap 3

Removing the SV Xchange Sensor Dry the sensor Unscrew the blue locking sleeve Lift the sensor out of the mount Ensure that the instrument socket is dry and clean, using compressed air if necessary Insert the blanking plug in the SV Xchange socket on the end-cap OR immediately insert a replacement SV Xchange sensor Pre-Deployment Procedures 4 to 6 weeks ahead o Use the receiving checklist on page 2 to verify the sensor is in good working order. o Verify the calibration is valid for the duration of the deployment. Have the sensor re-calibrated if required or swap with another calibrated SV Xchange sensor. Before leaving the jetty o Ensure the SV Xchange sensor is properly mounted on the instrument. The blue locking sleeve should be full threaded onto the sensor mount of the instrument. o Test the instrument in fresh water to ensure the SV Xchange sensor is functioning properly. Post-Deployment Procedures Ensure the sensor is clean and dry before storage Periodic Maintenance Periodic maintenance will prolong the life of the sensor. The following is recommended: If the sensor is dirty or oily use warm soapy water and allow the instrument to soak before cleaning with a rag or soft brush. Rinse with fresh water. Before each deployment o Check the sensor is properly seated on the instrument o Check the sensor for cleanliness or damage After each deployment o Clean and rinse the sensor using fresh water Before installing on an instrument o Check the sensor for cleanliness or damage o Check the o-ring under the blue locking sleeve of the sensor for cleanliness and silicon grease Removing from an instrument o Ensure the sensor is clean and dry before removing o Install a new sensor or blanking plug into the instrument to protect the contacts of the sensor mount o Safely store the sensor Yearly o Send the sensor to a service centre for diagnostics and re-calibration 4

Inspecting & Replacing the O-ring It is crucial to keep the SV Xchange sensor s O-ring clean and greased. Any fibres or dirt on the o-ring will allow water into the connector and damage both the sensor and the sensor mount. To gain access to the o-ring, perform the following steps: Remove the sensor from the instrument Use a small screw driver to remove the retaining ring from the top of the blue locking sleeve Slide the retaining ring over the transducer plate Pinch the blue locking sleeve and slide it over the transducer plate The o-ring should be slick with grease. If the o-ring is dry re-grease it with silicone grease Inspect the o-ring for dirt. Clean and re-grease if necessary Inspect the o-ring for nicks and cracks. If any are found the o-ring must be replaced. Use a 2-116-N70D Buna Nitrile o-ring. Grease the o-ring with silicone grease before replacing. Caution: Do not use a sharp instrument to remove the o-ring. If the o-ring groove is scratched the o-ring will not provide a waterproof seal. Slide the blue locking sleeve back over the o-ring Re-install the retaining ring Remove Retainer Pinch Hard and Lift Sleeve Check O-ring 5

SV Xchange Commands When using AML s SeaCast application software, knowledge of the instrument command set is not usually necessary. However, the operator can issue text commands to the instrument as well as to specific sensors on an instrument. This can be done from SeaCast or any terminal emulation program such as HyperTerminal. There is additional functionality on SV Xchange equipped instruments with respect to the command set. To use these commands, the user must first establish direct communication with the SV Xchange sensor. Talking to the SV Xchange Sensor There are two ways to accomplish direct communication with the SV Xchange sensor. They are: 1. On a Micro SV instrument with the SV Xchange option, the SV Xchange commands can be given directly to the instrument. Simply type the commands into the terminal emulation program. 2. On any SV Plus, Minos or Smart instrument that has the SV Xchange option, the TALK command is used to direct communications to the SV Xchange sensor. Use the following procedure to accomplish this: Entering Talk Mode o Establish communications with the instrument o Send a DETECT command to the instrument. The instrument will return a list of sensors detected on each slot of the instrument. The SV Xchange is usually in slot one but on instruments equipped with conductivity sensors the SV Xchange may be located in a different slot. o Send a TALK 1 command to the instrument. Replace the 1 with the appropriate slot number if required. This command directs subsequent communications directly to the sensor board. Exiting Talk Mode o To exit talk mode simultaneously press the CTRL and C keys Specific Commands of Interest DIS OPTIONS DIS SV CAL SET FORMAT 43 SET FORMAT 42 SET FORMAT 41 SET FORMAT 40 Displays the current settings for the SV Xchange Displays the calibration sheet for the sensor Sets the SV format to 4 digits ahead of the decimal place and 3 digits after the decimal place Sets the SV format to 4 digits ahead of the decimal place and 2 digits after the decimal place Sets the SV format to 4 digits ahead of the decimal place and 1 digits after the decimal place Sets the SV format to 4 digits with no decimal The full set of commands can be found in the Command Summary document, which is available from the AML Oceanographic s customer portal on the internet or by contacting the AML service department. 6

Customer Support Troubleshooting Instrument fails to detect the sensor Is the sensor properly mounted on the instrument? o Check the connector on both the sensor and the instrument for corrosion or damaged contacts o Cycle the instrument power Call the nearest service center for support SV sensor reads 0 m/s Is the sensor immersed in water? Are there bubbles on the reflector plate or transducer face? Is the acoustic path obstructed by dirt or biofouling? Is the sensor damaged? Is the water excessively turbid? Call the nearest service center for support Is there electrical noise on the power or communication lines? There should be no transient spikes greater than 20 mv. SV sensor is noisy Check the connector on both the sensor and the instrument for corrosion or damaged contacts Check the sensor for bubbles on the reflector and transducer surfaces Are there small scale thermal or salinity eddies or stratification of the water being tested? Is the water excessively turbid? Is there a nearby source of electromagnetic interference? Examples are arcing brushes on electric motors, radio transmitters, and faulty cathode ray tube monitors. Check for electrical noise on the power and communication lines with respect to ground. There should be no transient spikes greater than 20 mv. 7

AML Contact Info Service: To request an RMA or technical support Email: service@amloceanographic.com Phone: 1-250-656-0771 Fax: 1-250-655-3655 Sales: For all general sales inquiries Email: sales@amloceanographic.com Phone: 1-250-656-0771 Fax: 1-250-655-3655 Website: http://www.amloceanographic.com Customer Portal: The Customer Portal allows AML Oceanographic customers to download calibration certificates and other related instrument/sensor documentation, view instrument/sensor details and diagnostic reports. It also allows AML customers to gather technical documentation, troubleshooting guides etc. RMA requests or technical support queries may also be submitted through the portal. To access the Customer Portal, please navigate to the Support button, located on the top right hand side of AML Oceanographic home page, select the Customer Centre from the options on the drop down menu and follow the instructions provided. Mailing and Shipping Address: AML Oceanographic 2071 Malaview Ave. Sidney, BC, Canada V8L 5X6 8