RE866 Interface User Guide

Similar documents
ESS Utility Android App User Guide

GE865-JF2 Interface Application Note NT10067A Rev

AN S1401 Using BlueMod+S as Beacon

MultiTech Conduit AEP + RE866

Terminal I/O Profile Client Implementation Guide

BlueEva+S42M Evaluation Kit User Guide. 1VV Rev

ComAPI+ API Documentation

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

IoT AppZone Release Notes

GS2K External Flash based Host Firmware Update Application Note NT11608A Rev

Client EPO Distribution Server

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

GS2K OV SDK User Guide. 1VV Rev

BlueEva+SR Evaluation Kit User Guide. 1VV Rev

NE866B1-E1/NL865B1-E1 Quick Start Guide

BlueEva+S50/Central Evaluation Kit User Guide. 1VV Rev

IoT AppZone Release Notes

ME Demo Case User Guide. 1vv Rev

SE868-V3 EVK User Guide. 1VV r

SE878Kx-Ax Family EVK User Guide. 1VV Rev

SE880 RDK User Manual 1VV

SL869-V3 EVK User Guide. 1VV Rev

Premium FOTA Management Product Description ST10048a Rev

GS2K Hosted HomeKit User Guide. 1VV Rev

Event Monitor Application Note NT10028a Rev

Copyright Telit Communications S.p.A

SL871 & SL869 V2 Families Evaluation Kit User Guide. 1VV r

LE920A4/LE910Cx Wi-Fi Interface

SIM INTEGRATION DESIGN GUIDE

Telit GNSS Bundle Solutions Application Note NT11300A r

Assisted GPS (A-GPS) Application Note NT10066A Rev

End User License Agreement

GE310-GNSS INTERFACES USER GUIDE 1VV Rev

HE910/UE910/UL865 Families Ports Arrangements User Guide. 1vv Rev

xl865 Global Form Factor Application Note 80000NT11207A Rev

BlueMod+S42/Central Software User Guide

DATASHEET 4D SYSTEMS. 4D Raspberry Pi Serial Adaptor TURNING TECHNOLOGY INTO ART. 4D-Serial-Pi-Adaptor

DATASHEET 4D SYSTEMS. 4D Raspberry Pi Serial Adaptor TURNING TECHNOLOGY INTO ART. 4D-Serial-Pi-Adaptor

DATASHEET 4D SYSTEMS TURNING TECHNOLOGY INTO ART. USB to Serial UART Bridge Converter. Document Date: 5 th September 2012 Document Revision: 1.

Telit FOTA AT Script NT11347A Rev [ ] Mod Rev.7

DATASHEET 4D SYSTEMS. 4D Raspberry Pi Serial Adaptor TURNING TECHNOLOGY INTO ART. 4D-Serial-Pi-Adaptor

LE910Cx WE866C3-P Bundling Use Case Reference Guide. 1VV Rev

DATASHEET 4D SYSTEMS. uusb-pa5 uusb-pa5-ii. microusb Programming Adaptor TURNING TECHNOLOGY INTO ART. USB to UART Serial Bridge

TelitView Software Description (Version 2.2.0)

Workshop 4 Installation INSTALL GUIDE. Document Date: February 4 th, Document Revision: 1.1

DATASHEET 4D SYSTEMS TURNING TECHNOLOGY INTO ART. microusb Programming Adaptor. USB to UART Serial Bridge

DATASHEET 4D SYSTEMS. 4D Arduino Adaptor Shield TURNING TECHNOLOGY INTO ART. 4Display-Adaptor-Shield

LE910 V2 SERIES PORTS ARRANGEMENTS

Cambium PTP 650 LPU and Grounding Kit Installation Guide

SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE

MMI EXT CARD HW USER GUIDE xe922-3gr. 1VV Rev

DATASHEET. gen4 Programming Adaptor For all gen4 sizes (Picaso and Diablo16) gen4-pa. Document Date: 29 th January 2016 Document Revision: 1.

ME910C1 PSM Application Note

Cambium Wireless Manager

Applicability Table PRODUCT

Installing Your Microsoft Access Database (Manual Installation Instructions)

1. License Grant; Related Provisions.

Introduction. Rev.1.2

DATASHEET. 3.2 Display Bezel. 4D-Bezel-32 For the ulcd-32ptu Display Module. Document Date: 16 th September 2013 Document Revision: 1.

4D Systems. Application Note: 4D-AN-G3001. in ViSi Environment. Document Date: 15 th December Document Revision: 1.0

TERMS & CONDITIONS. Complied with GDPR rules and regulation CONDITIONS OF USE PROPRIETARY RIGHTS AND ACCEPTABLE USE OF CONTENT

Evaluation Board User Guide UG-302

Reference Guide VIB 10/11. (VIB 10 pictured) vehicle integration box

MyCreditChain Terms of Use

CEC1702 clicker. a great idea is just a click away

DATASHEET. 4.3 Embedded SPI Display. 4DLCD-FT843 Powered by the FTDI FT800 Video Engine. Document Date: 25 th September 2013 Document Revision: 0.

TO OUR VALUED CUSTOMERS

GS2K WAC Provisioning ADK Application Note NT11590A Rev

LAN9512 Evaluation Board User Manual

HX2VL Development Kit Guide. Doc. # Rev. *A

HX2VL Development Kit Guide. Doc. # Rev. **

OUR CUSTOMER TERMS CLOUD SERVICES MCAFEE ENDPOINT PROTECTION ESSENTIAL FOR SMB

StickIt! MPU-9150 Manual. How to install and use your new StickIt! MPU-9150 Module

ADN. System Installer. Instruction manual

VENUS_ Driving Board and 39.6 Prism Display

AccelDSP Synthesis Tool

Mile Terms of Use. Effective Date: February, Version 1.1 Feb 2018 [ Mile ] Mileico.com

Synthesis Options FPGA and ASIC Technology Comparison - 1

SW Versions GC Family ( Compact ) GE/GL Family ( Embedded ) xx xx xx2 GT Family ( Terminal ) xx7 Note:

Cambium Wireless Manager Performance Tuning Guide

Bar Code Discovery. Administrator's Guide

Terms of Use. Changes. General Use.

4D Systems. Application Note: 4D-AN-P2002. Playing Video on PICASO based modules using RAW option. Document Date: 15 th December 2012

DATASHEET 4D SYSTEMS. 4Display Shield with 2.2 Display TURNING TECHNOLOGY INTO ART. 4Display-Shield-22

CAUTION This device is sensitive to ElectroStatic Discharge (ESD). Therefore care should be taken during transport and handling.

Stellar Repair for Video

Broadband system applications i.e. WCDMA, CATV, etc. General purpose Voltage Controlled Attenuators for high linearity applications

GUI design made easy. Creating the First Project with. additional software

4D SYSTEMS APPLICATION NOTE. Application Note: 4D-AN-G5001 TURNING TECHNOLOGY INTO ART. Serial - Displaying Third-Party Fonts

PRODUCT GUIDE. N u c l e u s D a t a R e c o v e r y. C o m P r i v a t e L i m i t e d

4D SYSTEMS APPLICATION NOTE. Application Note: 4D-AN-P3001 TURNING TECHNOLOGY INTO ART. ViSi - Displaying Third-Party Fonts

SHIELD. mikromedia 5. for TIVA ARM

mikrobasic PRO for FT90x Creating the first project in

MERIDIANSOUNDINGBOARD.COM TERMS AND CONDITIONS

PRODUCT GUIDE. N u c l e u s D a t a R e c o v e r y. C o m P r i v a t e L i m i t e d

PRODUCT GUIDE. L e p i d e S o f t w a r e P r i v a t e L i m i t e d

EVB-USB2250 User Manual Revision B

4D SYSTEMS TURNING TECHNOLOGY INTO ART. Application Note: 4D-AN-G5002

VP-UML Installation Guide

UM NXP USB PD shield board user manual COMPANY PUBLIC. Document information

Transcription:

RE866 Interface User Guide 1VV0301387 Rev.0 6/16/2017 [04.2016] Mod. 0809 2016-08 Rev.7

SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE NOTICE While reasonable efforts have been made to assure the accuracy of this document, Telit assumes no liability resulting from any inaccuracies or omissions in this document, or from use of the information obtained herein. The information in this document has been carefully checked and is believed to be reliable. However, no responsibility is assumed for inaccuracies or omissions. Telit reserves the right to make changes to any products described herein and reserves the right to revise this document and to make changes from time to time in content hereof with no obligation to notify any person of revisions or changes. Telit does not assume any liability arising out of the application or use of any product, software, or circuit described herein; neither does it convey license under its patent rights or the rights of others. It is possible that this publication may contain references to, or information about Telit products (machines and programs), programming, or services that are not announced in your country. Such references or information must not be construed to mean that Telit intends to announce such Telit products, programming, or services in your country. COPYRIGHTS This instruction manual and the Telit products described in this instruction manual may be, include or describe copyrighted Telit material, such as computer programs stored in semiconductor memories or other media. Laws in the Italy and other countries preserve for Telit and its licensors certain exclusive rights for copyrighted material, including the exclusive right to copy, reproduce in any form, distribute and make derivative works of the copyrighted material. Accordingly, any copyrighted material of Telit and its licensors contained herein or in the Telit products described in this instruction manual may not be copied, reproduced, distributed, merged or modified in any manner without the express written permission of Telit. Furthermore, the purchase of Telit products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of Telit, as arises by operation of law in the sale of a product. COMPUTER SOFTWARE COPYRIGHTS The Telit and 3rd Party supplied Software (SW) products described in this instruction manual may include copyrighted Telit and other 3rd Party supplied computer programs stored in semiconductor memories or other media. Laws in the Italy and other countries preserve for Telit and other 3rd Party supplied SW certain exclusive rights for copyrighted computer programs, including the exclusive right to copy or reproduce in any form the copyrighted computer program. Accordingly, any copyrighted Telit or other 3rd Party supplied SW computer programs contained in the Telit products described in this instruction manual may not be copied (reverse engineered) or reproduced in any manner without the express written permission of Telit or the 3rd Party SW supplier. Furthermore, the purchase of Telit products shall not be deemed to grant either directly or by implication, estoppel, or otherwise, any license under the copyrights, patents or patent applications of Telit or other 3rd Party supplied SW, except for the normal non-exclusive, royalty free license to use that arises by operation of law in the sale of a product. Page 2 of 17 6/16/2017

USAGE AND DISCLOSURE RESTRICTIONS I. License Agreements The software described in this document is the property of Telit and its licensors. It is furnished by express license agreement only and may be used only in accordance with the terms of such an agreement. II. Copyrighted Materials Software and documentation are copyrighted materials. Making unauthorized copies is prohibited by law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language or computer language, in any form or by any means, without prior written permission of Telit III. High Risk Materials Components, units, or third-party products used in the product described herein are NOT fault-tolerant and are NOT designed, manufactured, or intended for use as on-line control equipment in the following hazardous environments requiring fail-safe controls: the operation of Nuclear Facilities, Aircraft Navigation or Aircraft Communication Systems, Air Traffic Control, Life Support, or Weapons Systems (High Risk Activities"). Telit and its supplier(s) specifically disclaim any expressed or implied warranty of fitness for such High Risk Activities. IV. Trademarks TELIT and the Stylized T Logo are registered in Trademark Office. All other product or service names are the property of their respective owners. V. Third Party Rights The software may include Third Party Right software. In this case you agree to comply with all terms and conditions imposed on you in respect of such separate software. In addition to Third Party Terms, the disclaimer of warranty and limitation of liability provisions in this License shall apply to the Third Party Right software. TELIT HEREBY DISCLAIMS ANY AND ALL WARRANTIES EXPRESS OR IMPLIED FROM ANY THIRD PARTIES REGARDING ANY SEPARATE FILES, ANY THIRD PARTY MATERIALS INCLUDED IN THE SOFTWARE, ANY THIRD PARTY MATERIALS FROM WHICH THE SOFTWARE IS DERIVED (COLLECTIVELY OTHER CODE ), AND THE USE OF ANY OR ALL THE OTHER CODE IN CONNECTION WITH THE SOFTWARE, INCLUDING (WITHOUT LIMITATION) ANY WARRANTIES OF SATISFACTORY QUALITY OR FITNESS FOR A PARTICULAR PURPOSE. NO THIRD PARTY LICENSORS OF OTHER CODE SHALL HAVE ANY LIABILITY FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING WITHOUT LIMITATION LOST PROFITS), HOWEVER CAUSED AND WHETHER MADE UNDER CONTRACT, TORT OR OTHER LEGAL THEORY, ARISING IN ANY WAY OUT OF THE USE OR DISTRIBUTION OF THE OTHER CODE OR THE EXERCISE OF ANY RIGHTS GRANTED UNDER EITHER OR BOTH THIS LICENSE AND THE LEGAL TERMS APPLICABLE TO ANY SEPARATE FILES, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Page 3 of 17 6/16/2017

APPLICABILITY TABLE PRODUCTS RE866-A1 Page 4 of 17 6/16/2017

CONTENTS NOTICE... 2 COPYRIGHTS... 2 COMPUTER SOFTWARE COPYRIGHTS... 2 USAGE AND DISCLOSURE RESTRICTIONS... 3 I. License Agreements... 3 II. Copyrighted Materials... 3 III. High Risk Materials... 3 IV. Trademarks... 3 V. Third Party Rights... 3 APPLICABILITY TABLE... 4 CONTENTS... 5 1. INTRODUCTION... 6 Scope... 6 Audience... 6 Contact Information, Support... 6 Text Conventions... 7 Related Documents... 7 2. BUNDLE OVERVIEW... 8 Setup... 8 RE866 Interface without EVK2... 10 Software... 11 3. SCHEMATICS... 14 Page 5 of 17 6/16/2017

1. INTRODUCTION Scope This document gives an overview of the RE866 interface for EVK2 Audience This document is intended only for Telit customers that wants to integrate the RE866 modules on their application. Contact Information, Support For general contact, technical support services, technical questions and report documentation errors contact Telit Technical Support at: TS-EMEA@telit.com TS-AMERICAS@telit.com TS-APAC@telit.com Alternatively, use: http://www.telit.com/support For detailed information about where you can buy the Telit modules or for recommendations on accessories and components visit: http://www.telit.com Our aim is to make this guide as helpful as possible. Keep us informed of your comments and suggestions for improvements. Telit appreciates feedback from the users of our information. Page 6 of 17 6/16/2017

Text Conventions Danger This information MUST be followed or catastrophic equipment failure or bodily injury may occur. Caution or Warning Alerts the user to important points about integrating the module, if these points are not followed, the module and end user equipment may fail or malfunction. Tip or Information Provides advice and suggestions that may be useful when integrating the module. All dates are in ISO 8601 format, i.e. YYYY-MM-DD. Related Documents 1VV0301365_RE866_AT_Command_Reference Telit EVK2 User Guide, 1VV0300704 Rev. 19 RE866 Hardware user guide Page 7 of 17 6/16/2017

2. BUNDLE OVERVIEW Setup The RE866 interface board has been designed to be mounted on top of the EVK2 Telit evaluation board. In the package of the RE866 Interface the 868 MHz Antenna for LoRa is included. This is interface should be mounted on the Telit EVK 2 interface. In order to have a full kit you need to order RE866 interface board (cod. 3990251568) and Telit EVK2 interface board (cod. 3990150474). On the picture below you find a picture of the RE866 interface with the indication of the main component interface Below you can find the Telit EVK2 interface Page 8 of 17 6/16/2017

After you plug the interface on top of the EVK and you connect the power cable and USB you will have the system below. Before connecting the power please check that the Power Selector on the interface (J100) has the jumper that close the PINs 1 and 2 of the power selector J100 as in the picture below, leave the others open. Page 9 of 17 6/16/2017

If the jumper is not present you can use one jumper present on USB jumpers on the EVK2 reserved for the the connection audio1 and audio 2 (red circle on the picture below). Finally be sure that the USB Jumpers on the EVK2 are selected on USB as in the picture below:. RE866 Interface without EVK2 The interface can be used also standalone without mount it on top of the EVK2 but in this case you need and FTDI for the serial connection that is at 3.3Volt and set the power selector register (J100) to use the external power supply as in the figure below. Page 10 of 17 6/16/2017

The jumper should close the PINs 5 and 6 of the J100 connector and the others open. After that you can power the board externally providing 3.3Volt by the pin 24 (positive) and 23 (negative) on the connector J103 (GPIOs connector) On the pin 15,16,17,18 can be find the RXD, TXD, RTS, CTS PINs at 3.3Volt level. In order to use this you need and FTDI cable in order to connect it to a USB port of the PC or and RS232 converted to connect to an UART port. Software No specific software is needed. After you power the and USB cable is connected you will have on the host the following 4 ports Normally the USB port to be used is the last one. Page 11 of 17 6/16/2017

Open a terminal software (TeraTerm in the picture) with 115000 bps, 8, N, 1 and HW flow control enable setting like below: Press Ok and after connect and after that send AT followed by carriage return, you should get OK response as below: You can ask also the SW version with ATi98 and ATi99. Page 12 of 17 6/16/2017

To proceed now you can read the SW AT command user guide where you can find all the instruction to start using LoRa Note: the numbering of the USB ports can be different, if it in not the last in the numbering try the others with the same serial configuration. Page 13 of 17 6/16/2017

3. SCHEMATICS Page 14 of 17 6/16/2017

Page 15 of 17 6/16/2017

Revision Date Changes 0 6/16/2017 First issue Page 16 of 17 6/16/2017

[04.2016] Mod. 0809 2016-08 Rev.7