SPC BENCHMARK 1 EXECUTIVE SUMMARY MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS2500G2-25E SPC-1 IOPS 300,028

Similar documents
MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS3000G2

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 5600 V5

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 5500 V5

SPC BENCHMARK 1 INSPUR ELECTRONIC INFORMATION INDUSTRY CO. LTD. INSPUR AS5500G2 EXECUTIVE SUMMARY SPC-1 IOPS 1,500,346

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 6800 V3

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 5300 V5

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR DORADO5000 V3

LENOVO THINKSYSTEM DE6000H

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 18800F V5

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR V3

SPC BENCHMARK 1 FULL DISCLOSURE REPORT MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS3000G2 SPC-1 V3.4.0 SUBMISSION IDENTIFIER: A31005

FUJITSU LIMITED ETERNUS AF250 S2

TELECOMMUNICATIONS TECHNOLOGY ASSOCIATION JET-SPEED HHS3124F / HHS2112F (10 NODES)

HUAWEI TECHNOLOGIES CO., LTD. HUAWEI FUSIONSTORAGE

FUSIONSTACK CO., LTD FUSIONSTOR SF6000

SPC BENCHMARK 1 EXECUTIVE SUMMARY HUAWEI TECHNOLOGIES CO., LTD. HUAWEI OCEANSTOR 5500 V3 SPC-1 V1.14

SPC BENCHMARK 1 FULL DISCLOSURE REPORT LENOVO THINKSYSTEM DE6000H SPC-1 V3.8 SUBMISSION IDENTIFIER: A32008

SPC BENCHMARK 1 EXECUTIVE SUMMARY

SPC BENCHMARK 1 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX200 S3 SPC-1 V1.14

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM SYSTEM STORAGE DS3524 EXPRESS SPC-1 V1.12

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM STORWIZE V7000 (SSDS) SPC-1 V1.12

SPC BENCHMARK 2 EXECUTIVE SUMMARY FUJITSU LIMITED FUJITSU STORAGE SYSTEMS ETERNUS DX8700 S2 SPC-2 V1.4

SPC BENCHMARK 1 FULL DISCLOSURE REPORT FUJITSU LIMITED ETERNUS AF650 S2 SPC-1 V3.5.0 SUBMISSION IDENTIFIER: A32004

Dell DL4300 Appliance Interoperability Guide

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM SYSTEM STORAGE DS8700 RELEASE 5.1 (EASYTIER AND SSDS) SPC-1 V1.12

SPC BENCHMARK 2 FULL DISCLOSURE REPORT VEXATA INC. VX100-F SCALABLE NVME FLASH ARRAY SPC-2 V1.7.0 SUBMITTED FOR REVIEW: AUGUST 29, 2018

SPC BENCHMARK 1 EXECUTIVE SUMMARY PILLAR DATA SYSTEMS,INC. PILLAR AXIOM 600 SPC-1 V1.10.1

Database Size Database Manager Operating System Other Software Availability Date Throughput Power Arithmetic Mean Geometric Mean

SPC BENCHMARK 1 FULL DISCLOSURE REPORT HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR 5500 V5 SPC-1 V3.7 SUBMISSION IDENTIFIER: A31014

SPC BENCHMARK 1 FULL DISCLOSURE REPORT IBM CORPORATION IBM STORWIZE V3700 (TURBO) SPC-1 V1.14

SPC BENCHMARK 1 FULL DISCLOSURE REPORT LENOVO THINKSYSTEM DS4200 SPC-1 V3.4.0 SUBMISSION IDENTIFIER: A32002

SPC BENCHMARK 1 EXECUTIVE SUMMARY IBM CORPORATION IBM POWER 780 SERVER (WITH SSDS) SPC-1 V1.13

SPARC T5-4 Server. Total System Cost Composite Query per Hour Metric Price / Performance

HP ProLiant DL980 G7

SPARC T4-4 Server with. Oracle Database 11g Release 2

Sun SPARC Enterprise M9000 Server with Oracle Database 11g Release 2

Hewlett-Packard Enterprise Company

All-Flash High-Performance SAN/NAS Solutions for Virtualization & OLTP

SPC BENCHMARK 2 EXECUTIVE SUMMARY EMC CORPORATION EMC VMAX 400K SPC-2 V1.5. Submitted for Review: July 30, 2015 Submission Identifier: B00073

SPC BENCHMARK 1 FULL DISCLOSURE REPORT NETAPP AFF A800 SPC-1 V3.6.0 SUBMISSION IDENTIFIER: A32007

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR DORADO5000 V3 SPC-1 V3.5.0

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

IBM TotalStorage FAStT900 Storage Server New Offering Expands IBM SAN Storage Solutions

IBM System p Database Size Database Manager Operating System Other Software Availability Date. Seconds

Hitachi BladeSymphony BS2000 using Hitachi Advanced Data Binder 01-02

IBM System Storage DS3000 series Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

SPC BENCHMARK 2/ENERGY EXECUTIVE SUMMARY IBM CORPORATION IBM XIV STORAGE SYSTEM GEN3 SPC-2/E V1.4

SPC BENCHMARK 2 FULL DISCLOSURE REPORT SILICON GRAPHICS INTERNATIONAL CORP. SGI INFINITESTORAGE 5600 SPC-2 V1.4

HP ProLiant DL580 G7

TPC Benchmark H Full Disclosure Report. SPARC T4-4 Server Using Oracle Database 11g Release 2 Enterprise Edition with Partitioning

Dell DL1300 Appliance Interoperability Guide

IBM Storwize V7000 Unified

Tiered IOPS Storage for Service Providers Dell Platform and Fibre Channel protocol. CloudByte Reference Architecture

IBM System Storage DS3000 Interoperability Matrix IBM System Storage DS3000 series Interoperability Matrix

TPC Benchmark H Full Disclosure Report. SPARC T5-4 Server Using Oracle Database 11g Release 2 Enterprise Edition with Partitioning

Building resiliency with IBM System x and IBM System Storage solutions

Storage Area Network (SAN) Training Presentation. July 2007 IBM PC CLUB Jose Medeiros Storage Systems Engineer MCP+I, MCSE, NT4 MCT

TPC Benchmark TM C Full Disclosure Report

Infortrend Solution. Media & Entertainment. Feb Version: 1.5

TECHNICAL SPECIFICATIONS + TECHNICAL OFFER

ETERNUS DX60 and DX80

XenData Product Brief: SX-250 Server for Optical Disc Archive Libraries

SPC BENCHMARK 2 FULL DISCLOSURE REPORT HITACHI DATA SYSTEMS CORPORATION HITACHI UNIFIED STORAGE VM SPC-2 V1.5

IBM RS/6000 SP ,866.8 Operating System IBM AIX Power Test. Query Time in Seconds

SPC BENCHMARK 1C FULL DISCLOSURE REPORT ORACLE CORPORATION SUN STORAGE F5100 FLASH ARRAY SPC-1C V1.3

HUAWEI TECHNOLOGIES CO., LTD HUAWEI OCEANSTOR DORADO6000 V3 SPC-1 V3.4.0

Lot # 10 - Servers. 1. Rack Server. Rack Server Server

Vendor must indicate at what level its proposed solution will meet the College s requirements as delineated in the referenced sections of the RFP:

IBM Power 520 and Power 550 support the AIX, IBM i, and Linux operating systems

IBM System Storage DCS3700

IBM System Storage DS8870 Release R7.3 Performance Update

IBM RS/6000 Enterprise Server J50 c/s

SPECIFICATION FOR NETWORK ATTACHED STORAGE (NAS) TO BE FILLED BY BIDDER. NAS Controller Should be rack mounted with a form factor of not more than 2U

FLASHARRAY//M Business and IT Transformation in 3U

EMC VMAX 400K SPC-2 Proven Performance. Silverton Consulting, Inc. StorInt Briefing

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018

All-Flash High-Performance SAN/NAS Solutions for Virtualization & OLTP

Lenovo Database Configuration

Exchange Server 2007 Performance Comparison of the Dell PowerEdge 2950 and HP Proliant DL385 G2 Servers

Veritas NetBackup Appliance Fibre Channel Guide

CORRIGENDUM- 2 TO REQUEST FOR PROPOSAL

IBM System Storage DS5020 Express

The Oracle Database Appliance I/O and Performance Architecture

NEC Express5800/R120h-2E System Configuration Guide

GB of cache memory per controller to DS4800 controllers with 8 GB of cache memory per controller.

Hardware withdrawal: Lenovo System x select options/features

SPC BENCHMARK 2 EXECUTIVE SUMMARY VEXATA INC. VX100-F SCALABLE NVME FLASH ARRAY SPC-2 V1.7.0 SUBMITTED FOR REVIEW: AUGUST 29, 2018

Storage Update and Storage Best Practices for Microsoft Server Applications. Dennis Martin President, Demartek January 2009 Copyright 2009 Demartek

IBM TotalStorage SAN Switch M12

IBM System Storage DS8000 series (Machine types 2421, 2422, 2423, and 2424) delivers new security, scalability, and business continuity capabilities

IBM System Storage SAN Made Simple

IBM Storwize V5000 disk system

LENOVO THINKSERVER OPTIONS AND UPGRADES

Company Profile. Infortrend Technology, Inc.

vstart 50 VMware vsphere Solution Specification

IBM Power 550 Express Edition: Exceptional reliability, availability, and serviceability for entry and medium-size enterprises

HighPoint Chameleon. SATA JBOD Device Solutions. SAS JBOD Device Solutions. Direct Connectivity Solutions

Dell EMC SCv3020 7,000 Mailbox Exchange 2016 Resiliency Storage Solution using 7.2K drives

Dell EMC SC Series SC5020 9,000 Mailbox Exchange 2016 Resiliency Storage Solution using 7.2K Drives

TPC-E testing of Microsoft SQL Server 2016 on Dell EMC PowerEdge R830 Server and Dell EMC SC9000 Storage

Transcription:

EXECUTIVE SUMMARY SPC BENCHMARK 1 EXECUTIVE SUMMARY MACROSAN TECHNOLOGIES CO., LTD MACROSAN MS2500G2-25E SPC-1 IOPS 300,028 SPC-1 Price-Performance $379.50/SPC-1 KIOPS SPC-1 IOPS Response Time 0.480 ms SPC-1 Overall Response Time 0.388 ms SPC-1 ASU Capacity 10,640.0 GB SPC-1 ASU Price $10.71/GB SPC-1 Total System Price $113,858.31 Data Protection Level Physical Storage Capacity Pricing Currency / Target Country Protected 2 (RAID 10 and full redundancy) 21,408 GB U.S. Dollars / People s Republic of China SPC-1 V3.6.0 SUBMISSION IDENTIFIER: A31011 SUBMITTED FOR REVIEW: FEBRUARY 12, 2018

EXECUTIVE SUMMARY Page 2 of 5 Benchmark Configuration Diagram

EXECUTIVE SUMMARY Page 3 of 5 Tested Storage Product Description The is a new product in the MacroSAN MS2500G2 series, which is the new generation of MacroSAN entry-level data center storage products, oriented toward small size data centers and branches. Based on its leading hardware architecture and rich software function, the MS2500G2-25E can provide more storage solutions for the small business to guarantee data safety and service continuity, including database storage solution, centralized online storage, backup storage solution, data disaster recovery solution and more. The MS2500G2-25E provides an optimal balance between performance and cost, with better reliability and expansion capability, to support customer s rapid business growth. For more details, visit: http://www.macrosan.com/en/product_detail.aspx?k1=2&k2=10&id=73 Priced Storage Configuration Components 8 x QLogic QLE2564 4-port FC HBAs 2 x MacroSAN MS2500G2 Engines, each with: 2 x Controllers/Storage Processors, each with: 32GB cache 1 x 4-port 8Gb FC I/O Modules 1 x 2-port 10Gb SFP Modules 1 x 2-port 6Gb SAS 2.0 I/O Modules 12 x 480GB MLC SSDs 2 x External storage enclosures, each with: 12 x 480GB MLC SSDs

EXECUTIVE SUMMARY Page 4 of 5 Storage Configuration Pricing MS2500G2-25E-64GB DSU2625 MS2M1SD480G0M2AEA Description Qty Unit Price Ext. Price Disc. Disc. Price Hardware & Software MS2500G2-25E Storage Controllers Unit (Dual Controllers,2U,25*2.5 disks,64gb cache,4*ge ports+4*10ge port-no SFPs,3Y 7x9xND Basic Svc&Warranty) 2 18,595.59 37,191.18 50% 18,595.59 DSU2625 SAS/SATA Disk Shelf Unit (support 25 2.5inch disks, SAS 3.0) 2 6,223.53 12,447.06 50% 6,223.53 480GB MLC SSD Drive(2.5") for MS2500G2/DSU2625 48 2,367.65 113,647.20 50% 56,823.60 IOA1014A 4*8Gb FC IO Module 8 2,029.41 16,235.29 50% 8,117.65 MS1MMF010G 10Gb MultiMode Datacom SFP+ Optical Transceiver 8 321.32 2,570.56 50% 1,285.28 LIS_MS2000_BASE_STD MacroSAN ODSP for Multi control - MS2500G2 Storage Management Softw are(basic Storage Management, CRAID, sopport FC&iSCSI, System monitoring and Warning) -English version 1 4,102.94 4,102.94 50% 2,051.47 LIS_MS2000_2C_EXPAND MacroSAN ODSP-MS2500G2 storage system management softw are -2 Controllers- EXPAND 1 1,992.49 1,992.49 50% 996.25 LC05-LC05-MI2-L5 5M fiber( multimode, LC-LC) 20 8.00 160.00 160.00 MS4.150.0001MX RACK KIT(For 2U devices) 4 61.12 244.48 244.48 5020012 SAS cable (1M, minisashd-minisashd) 8 0.00 0.00 0.00 2090044 Qlogic QLE2564 HBA Card,PCIE,8Gbps 4- Ports,Fiber Channel Multimode LC Optic Interface 8 1,500.00 12,000.00 12,000.00 Support & Maintenance Hardw are & Softw are Subtotal 106,497.84 MS-2000-SV-BS-SPU MS2500G2 Installation Service - Per SPU 2 982.41 1,964.82 20% 1,571.86 MS-2001-SV-BS-DSU Disk Enclosure Installation Base Service per Set 2 588.24 1,176.48 20% 941.18 MS-2000-SV-GS-1Y-SPU MS2500G2 Svc&Warranty Upgrade - 7x24x4 Premium - Per Year Per SPU 2 1,711.89 3,423.78 20% 2,739.02 MS-2000-SV-GS-1Y-DSU MS2500G2 Svc&Warranty Upgrade - 7x24x4 Premium - Per Year Per DSU 2 1,317.75 2,635.50 20% 2,108.40 Support & Maintenance Subtotal 7,360.46 SPC-1 Total System Price SPC-1 IOPS SPC-1 Price-Performance ($/SPC-1 KIOPS ) SPC-1 ASU Capacity (GB) SPC-1 ASU Price ($/GB) 113,858.31 300,028 379.50 10,640 10.71 Discount Details: The discounts shown are generally available, and based on the capacity and total price of the storage configuration purchased. Warranty: Pricing includes Gold-Level Service with: 24x7 online support, unlimited software upgrades and bug fixes, and on-site presence of a qualified maintenance engineer within 4 hours of a problem acknowledgement, inside the Target Market. Availability Date: Currently available.

Average Response Time (ms) EXECUTIVE SUMMARY Page 5 of 5 Response Time and Throughput Graph 0.60 0.50 0.40 80% 100% 95% 90% 0.30 10% 50% 0.20 RAMPD Response Time SPC-1 Overall Response Time 0.10 0.00 0 50,000 100,000 150,000 200,000 250,000 300,000 350,000 I/O Requests per Second (IOPS) Contact Information Test Sponsor Primary Contact SPC Auditor MacroSAN Technologies Co., Ltd. http://www.macrosan.com.cn Yi Shen shenyi@macrosan.com InfoSizing www.sizing.com Francois Raab francois@sizing.com Revision Information SPC Benchmark 1 Revision SPC-1 Workload Generator Revision Publication Revision History V3.6.0 V3.0.2-1-g823a Initial Publication