TM 916x/926x T1 Access Mux Quick Reference Document Number 9161-A2-GL10-10 December 1998 Product Documentation on the World Wide Web We provide complete product documentation online. This lets you search the documentation for specific topics and print only what you need, reducing the waste of surplus printing. It also helps us maintain competitive prices for our products. Complete documentation for this product is available at www.paradyne.com. Select Service & Support Technical Manuals T1 Access Multiplexers. Select the following document: 9161-A2-GH30 Model 916x/926x T1 Access Mux Technical Reference To request a paper copy of a Paradyne document: Within the U.S.A., call 1-800-PARADYNE (1-800-727-2396) Outside the U.S.A., call 1-727-530-8623 Overview This quick reference summarizes the configuration options accessed when you select Configuration from the Main Menu. Not all options are available, but are filtered depending on what other options have been selected. Refer to Chapter 5, Setting Up, in the Model 916x/926x T1 Access Mux Technical Reference for more information. 1
Menu Hierarchy Network Channel Display DSX-1 Channel Display Port Assignment Display MAIN MENU Status Test Configuration Control Network Sync Data Ports Clear Statistics Status System and Test Status Voice Status Cross Connect Status Performance Statistics Identity System & NAM APM MAIN MENU Status Test Configuration Control Test Network Tests DSX-1 Tests Sync Data Port Tests Voice Port Tests OCU-DP Tests Device Tests Abort Tests MAIN MENU Status Test Configuration Control Load Configuration from: Configuration Edit/Display Network DSX-1 Sync Data Ports Voice Ports OCU-DP Copy Ports Cross Connect System Options User Interface Alarm Management and Communication MAIN MENU Status Test Configuration Control Control COM Port Call Setup COM Port Call Directories Device Name Date & Time Administer Logins System Alarm Relay Cut-Off Clear Device Fail Reset Device DSX-1 to Network Assignments Network to Network Assignments Voice Port Assignments Sync Data Port Assignments OCU-DP Port Assignments Clear Assignments Communication Port External Device (Com Port) Telnet/FTP Sessions Communication Protocol General SNMP Management SNMP NMS Security SNMP Traps 98-15081-03 2
Network Network 1, 2 Interface Status 1 Line Framing Format Line Coding Format D4, [ESF] AMI, [B8ZS] Line Build Out (LBO) [0.0], 7.5, 15, 22.5 Bit Stuffing Network Initiated LLB Network Initiated PLB Transmit Timing 3 ANSI Performance Report Messages Management Link IP Address 2 Subnet Mask Routing Information Protocol Network Time Slot Circuit Identifier Loss of Signal (LOS) Alarm Out of Frame (OOF) Alarm Alarm Indication Signal (AIS) Yellow Alarm [62411], Part68, Disable [System], Network [Disable], FDL, DDL [000.000.000.000] 223.255.255.255, Clear [000.000.000.000] 255.255.255.255, Clear None, [Proprietary] 01 24 [lowest available time slot] Text field Excessive Error Rate (EER) Alarm Excessive Error Rate Threshold [10E-4], 10E-5, 10E-6, 10E-7, 10E-8, 10E-9 1 Read-only when Network is set to 1. 2 This first byte cannot be set to 0 nor 127. However, the null address of 0.0.0.0 is valid after performing a Clear. 3 Only shown when 9261 T1 NAM is being used. 3
DSX-1 Slot ss 916x: 01 9261 NAM: 02 9265: 02, 03, 04, 05 Port p 916x: 1 926x: 1, 2 Interface Status Line Framing Format Line Coding Format D4, [ESF] AMI, [B8ZS] Line Equalization [0 133], 133 266, 266 399, 399 533, 533 655 Send All Ones on DSX-1 Failure Loss of Signal (LOS) Alarm Out of Frame (OOF) Alarm Alarm Indication Signal (AIS) Yellow Alarm 4
Sync Data Ports Slot ss 9x62: 01, 02 9x65: 01, 02, 03, 04, 05 Port p T1 NAM: 1, 2 Sync Data APM: 1, 2, 3, 4 Port Status Port Type [E530], V.35, RS449, X.21 Port Base Rate Transmit Clock Source Invert Transmit Clock Invert Transmit and Received Data Send All Ones on Data Port Not Ready Action on Network Yellow Alarm Network Initiated Data Channel Loopback (DCLB) Port (DTE) Initiated Loopbacks Embedded Data Link EDL Management Link IP Address 1 Subnet Mask Routing Information Protocol Near-End Performance Statistics Far-End Performance Statistics Out of Frame (OOF) Alarm Excessive Error Rate (EER) Alarm [Nx64], Nx56 [Internal], External Disable, DTR, RTS, [Both] None, [Halt] [Disable], V.54, FT1, Both [Disable], DTPLB, DCLB, Both [000.000.000.000] 223.255.255.255, Clear [000.000.000.000] 255.255.255.255, Clear None, [Proprietary] [Disable], Maintain, Send, Both [Disable], Maintain Excessive Error Rate Threshold [10E-4], 10E-5, 10E-6, 10E-7, 10E-8, 10E-9 1 This first byte cannot be set to 0 nor 127. However, the null address of 0.0.0.0 is valid after performing a Clear. 5
Voice Ports E&M Voice Slot ss 9x62: 02 9x65: 02, 03, 04, 05 Port p 1, 2, 3, 4, 5, 6, 7, 8 Port Status Operating Mode [E&M], Transmit Only Rx Gain (db) 17.0, 16.5, 16.0, 15.5, 15.0,..., [0.0],..., +6.5, +7.0, +7.5 Tx Attenuation (db) 17.0, 16.5, 16.0, 15.5, 15.0,..., [0.0],..., +6.5, +7.0, +7.5 Trunk Cond in CGA [Busy], Idle FXO Voice Slot ss 9x62: 02 9x65: 02, 03, 04, 05 Port p 1, 2, 3, 4, 5, 6, 7, 8 Port Status Operating Mode Signaling Type [FXO], FXODN, FXODN/WINK, DPT [Loop-Start], Loop-Start/Fwd-Disc, Ground-Start Terminating Impedance (ohms) [600], 900 Wink Delay (10 ms) 1 99 [15] Wink Duration (10 ms) 1 99 [20] Rx Gain (db) 10.00, 9.5, 9.0, 8.5,..., [0.0], +0.5, +1.0, +1.5, +2.0 Tx Attenuation (db) 10.00, 9.5, 9.0, 8.5,..., [0.0],..., +4.0, +4.5, +5.0 Trunk Cond in CGA [Busy], Idle 6
Voice Ports (continued) FXS Voice Slot ss 9x62: 02 9x65: 02, 03, 04, 05 Port p 1, 2, 3, 4, 5, 6, 7, 8 Port Status Operating Mode Signaling Type [FXS], FXSDN, FXSDN/WINK, PLAR, DPO [Loop-Start], Loop-Start/Fwd-Disc, Ground-Start, Ground-Start-Immediate, Ground-Start-Automatic, d3, d4 Terminating Impedance (ohms) [600], 900 Wink Delay (10 ms) 1 99 [15] Wink Duration (10 ms) 1 99 [20] Rx Gain (db) 10.00, 9.5, 9.0, 8.5,..., [0.0], +0.5, +1.0, +1.5, +2.0 Tx Attenuation (db) 10.00, 9.5, 9.0, 8.5,..., [0.0],..., +4.0, +4.5, +5.0 Ring-Back Tone Trunk Cond in CGA [Busy], Idle 7
OCU-DP Ports Slot ss 9x62: 02 9x65: 02, 03, 04, 05 Port p 2-port: 1, 2 6-port: 1, 2, 3, 4, 5, 6 Port Status Port Rate [56K], 64KCC, Switched_56 Loopback Detection Loss of Signal Alarm Abnormal Station Code Alarm 64KCC Loop OOF Alarm DDS Network Failure Alarm Loss of Loop Timing Alarm 8
Cross Connect See the Technical Reference for information on cross connections. Copy Ports From: Slot ss 9x62: 01, 02 9x65: 01, 02, 03, 04, 05 From: Port p T1 NAM: 1, 2 Sync Data APM: 1, 2, 3, 4 Voice APM: 1, 2, 3, 4, 5, 6, 7, 8 OCU-DP (2-port): 1, 2 OCU-DP (6-port): 1, 2, 3, 4, 5, 6 Type T1 NAM, Sync Data, FXS Voice, FXO Voice, E&M Voice, OCU-DP To: Slot ss 9x62: All, 01, 02 9x65: All, 01, 02, 03, 04, 05 [lowest numbered slot containing the same port type] To: Port p T1 NAM: 1, 2 Sync Data APM: 1, 2, 3, 4 Voice APM: 1, 2, 3, 4, 5, 6, 7, 8 OCU-DP (2-port): 1, 2 OCU-DP (6-port): 1, 2, 3, 4, 5, 6 Perform Copy Perform Copy Then Increment n/a n/a 9
System Options Generate Yellow Alarm Signals Test Timeout Test Duration (min) 1 120 [10] Primary Clock Source [Net1], Net2, DSXss-p, Internal, External, Sync Data Port (for Primary Clock Source) Sss Pp [the first available port] Secondary Clock Source Net1, Net2, DSXss-p, [Internal], External, Sync Data Port (for Secondary Clock Source) Sss Pp [the first available port] External Clock Rate (KHz) 8, [1544], 2048 Primary Clock Failure Alarm Secondary Clock Failure Alarm 10
User Interface Communication Port Physical characteristics of the Port (Port 1 or 2) Port Use Port Type RIP 1 [Terminal], Net Link, Alarm [Asynchronous], Synchronous [None], Proprietary Port Type Synchronous Clock Source [Internal], External Data Rate (Kbps) 2 9.6, 14.4, [19.2], 28.8, 38.4, 57.6, 115.2 Port Type Asynchronous Data Rate (Kbps) 9.6, 14.4, [19.2], 28.8, 38.4, 57.6, 115.2 Character Length 3 7, [8] Parity 3 [None], Even, Odd Stop Bits 3 [1], 1.5, 2 Ignore Control Leads Login Required 4 Port Access Level 4 Inactivity Timeout 4 [Disable], DTR [Level-1], Level-2, Level-3 Disconnect Time (Minutes) 4,5 1 60 [5] 1 Only shown when Port Use is set to Net Link. 2 Only shown when Clock Source is set to Internal. 3 Only shown when Port Type is set to Asynchronous. 4 Only shown when Port Use is set to Terminal. 5 Only shown when Inactivity Timeout is set to Enable. 11
User Interface (continued) External Device (COM Port) External Device Commands Dial-In Access 6 Connect Prefix 7 Connect Indication String 7 Escape Sequence 7 [Disable], AT, Other ASCII text entry, Clear ASCII text entry, Clear ASCII text entry, Clear Escape Sequence Delay (Sec) 7 [None], 0.2, 0.4, 0.6, 0.8, 1.0 Disconnect String 7 ASCII text entry, Clear Telnet/FTP Sessions Telnet Session Telnet Login Required Session Access Level Inactivity Timeout [Level-1], Level-2, Level-3 Disconnect Time (Minutes) 1 60 [5] FTP Session FTP Login Required 6 Only shown when External Device Commands is set to Other or AT. 7 Only shown when External Device Commands is set to Other. Alarm ASCII Alarm Messages Alarm & Trap Dial Out Trap Disconnect Call Retry Com Port, [Disable] Dial-Out Delay Time (Min) 1 10 [5] Alternate Dial-Out Directory [None], 1 5 System Alarm Relay 12
Management and Communications Communication Protocol Node IP Address 1 Node Subnet Mask Default Network Destination Communication Port IP Address 1 Communication Port Subnet Mask Communication Port Link Protocol Alternate Communication Port IP Address 1 Alternate Communication Port Subnet Mask [000.000.000.000] 223.255.255.255, Clear [000.000.000.000] 255.255.255.255, Clear [None], COM, FDL1, FDL2, DDL, EDLss-p [000.000.000.000] 223.255.255.255, Clear [000.000.000.000] 255.255.255.255, Clear [PPP], SLIP [000.000.000.000] 223.255.255.255, Clear [000.000.000.000] 255.255.255.255, Clear General SNMP Management SNMP Management Community Name 1 Name 1 Access Community Name 2 Name 2 Access ASCII text entry [Public], Clear [Read], Read/Write ASCII text entry, [Clear] [Read], Read/Write SNMP NMS Security NMS IP Validation Number of Managers 1 10 [1] NMS n IP Address Access Level [000.000.000.000] 223.255.255.255, Clear [Read], Read/Write 1 The first byte cannot be set to 0 nor 127. However, the null address of 0.0.0.0 is valid after performing a Clear. 13
Management and Communications (continued) SNMP Traps SNMP Traps Number of Trap Managers 1 6 [1] NMS n IP Address 1 Destination General Traps Enterprise Specific Traps Link Traps Link Traps Interfaces 2 [000.000.000.000] 223.255.255.255, Clear [Default], COM, FDL1, FDL2, DDL, EDLss-p Disable, Warm, AuthFail, [Both] Disable, Up, Down, [Both] Network, DSX-1, T1s, Ports, [All] 1 The first byte cannot be set to 0 nor 127. However, the null address of 0.0.0.0 is valid after performing a Clear. 2 DSX-1 and T1s only shown when DSX-1 interface is enabled. 14
Warranty, Sales, and Service Information Contact your local sales representative, service representative, or distributor directly for any help needed. For additional information concerning warranty, sales, service, repair, installation, documentation, training, distributor locations, or Paradyne worldwide office locations, use one of the following methods: Via the Internet: Visit the Paradyne World Wide Web site at http://www.paradyne.com Via Telephone: Call our automated call system to receive current information via fax or to speak with a company representative. Within the U.S.A., call 1-800-870-2221 Outside the U.S.A., call 1-727-530-2340 Document Feedback We welcome your comments and suggestions about this document. Please mail them to Technical Publications, Paradyne Corporation, 8545 126th Ave. N., Largo, FL 33773, or send e-mail to userdoc@eng.paradyne.com. Include the number and title of this document in your correspondence. Please include your name and phone number if you are willing to provide additional clarification. Trademarks All products and services mentioned herein are the trademarks, service marks, registered trademarks or registered service marks of their respective owners. Copyright 1998 Paradyne Corporation 15