LCD Readout Digital Pressure Switch

Similar documents
ISE5B. Series ZSE5B. Digital Pressure Switch. With Backlight. (For vacuum) (For positive pressure) For General Purpose Fluids

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

MPS-32. Pressure Sensors MPS-32 2-Color Panel Mount. Features. Green Display. MPS-32 Programming Options

The dual display means that the current value and the threshold value, it makes direct setting of threshold value

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

NEW product. Large digital pressure sensor 31series. Easily viewable LCD dual displays. High level visibility with 3-color display.

panasonic.net/id/pidsx/global

Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES. High-precision detection of fluid and air pressure

Multi Channel Pressure Sensor Controller Operation Manual PSE200 Series

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

EF-S1 SERIES. Continuously check invisible static electricity in lines. Constantly check static in lines!

The importance of the static electric control is put on confirming the actual status.

Head-separated Dual Display Digital Pressure Sensor DPC-100 SERIES DPH-100 SERIES

Type Pressure range description Part number

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

Head-separated Digital Pressure Sensor For Gas DP5 SERIES DPH SERIES. High speed response of 1/1,000 sec. High speed response 1 ms

+GF+ SIGNET ph/orp Transmitter Instructions

One step ahead in performance and mounting ease

E2Q4 Square Proximity Sensor

Cylindrical Proximity Sensor

Ordering Information. Smart Sensors (Inductive Displacement Type) ZX Series. Sensors

Plug-in unit extension block One sensor extension block allows four plug-in units to be added. Power cable for sensors. Snap-connector inputs

Series LC6D/LC6C. LJ1 LG1 LC1 LX LC6D/LC6C Switches LC6C LC6D. Series LX Dedicated Stepper Motor Driver and Positioning Driver

Vane Type Photoelectric Switches with Self-contained Amplifier

Connector Built-in U-shaped Micro Photoelectric Sensor. Approximately 60 % of previous model Detachable

EC07 EC63. Compatible actuators: ERL2 ESD2. How to order EC 07 B. Series. B Installation. method

High Pressure E/P Regulator. ITVH Series

Suitable for detecting transparent films or transparent bottles

GB MIX COMUNICAZIONE - MI. Digital Electro-pneumatic Regulator ER Series

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

Pressure Switch CE40. Digital settings available via IR data communication without actually applying pressure to the unit

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection. Hardly affected by background

Optimum sensing capability for LCD manufacturing

Flow Monitor PF2A20# PF2W20# PF2D20#

Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! 12 mm in

PM-24 SERIES. Ultra-small U-shaped Micro Photoelectric Sensor. Extremely small size enables space saving!! ( ) Equipped with two independent outputs

Adjustable Range Reflective Photoelectric Sensor Amplifier Built-in

PM2 SERIES. Convergent Reflective Micro Photoelectric Sensor. Convergent reflection sensing ensures stable detection

PC RELAY TERMINAL/ PC TERMINAL

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

PRESET HOUR METER. FEATURES 1. Preset function equipped in half size (24 48 mm inch). 2. Display has backlight for instant recognition.

Product Catalog. Represented by Norstat Inc. in North America

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

Self-Powered Counters H7EC

+GF+ SIGNET Conductivity/Resistivity Transmitter Instructions

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

2. Actuator B: Ball type P: Pin type F: Flat type

Communication & Networking

Inductive Proximity Sensor

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

High-speed sampling and high resolution. The new choice for even more variegated data collection and processing.

Convergent Reflective Micro Photoelectric Sensor

LASER. Laser Displacement Transducer. Series LAH-G1. Key-Features:

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

User safety and equipment protection guidelines

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Electrostatic Sensor Monitor IZE11

J8 SWITCHES WITH TRIP FUNCTION UPGRADED TYPE

Series Pressure Sensor Instruction Sheet

Chemical Resistant Inductive Prox

RT-1 PC RELAY TERMINAL RT-1 PC TERMINAL

DC 3-wire Cylindrical Inductive Proximity Sensor. Long sensing range

onlinecomponents.com

EE-SX91. Meeting Customer Needs with Compact Sensors that Mount with M3 Screws

PRD/PRDW Series. Long Distance Type

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability. IP67G sensor head variations

Mini Photoelectric Sensor

Thread length (overall length) material

Slot Style Photoelectric Sensors

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

DTY-EPS DTY-EPU. w e DTY-EPP- - w e. t y. q DTY-EPU PSU-BR DTY-EPP-CC- L DTY-EPS. ZD1 ZD4 Tr1 Tr4

Absolute Encoders Multiturn

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

V E2B Snap-in I/O Module

Digital Pressure Switch

U-shaped Type/Convergent Reflective Type. onlinecomponents.com

Inductive Proximity Sensor

Digital Indicator Solutions

MICREX-SX Series Renewal Tool Announcement of Release of MICREX-F Size I/O Module

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

GA-311 GH SERIES. Compact Inductive Proximity Sensor Amplifier-separated. High-speed response and excellent workability

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

-ment Ambient humidity 35 to 95%RH, Storage :35 to 95%RH

RK-2 CONTACTLESS MAGNETOSTRICTIVE LINEAR POSITION TRANSDUCER WITH FLANGED HEAD

Cylindrical Compact Inductive Proximity Sensor Amplifier Built-in. panasonic.net/id/pidsx/global

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

V E1B Snap-in I/O Module

Transcription:

LCD Readout Digital Pressure Switch Series 3 (For )/ 3 (For Positive Pressure) For General Pneumatics Easy pressure setting with the digital display Can be integrated with a vacuum unit, Series ZX Built-in failure prediction output function When system performance declines due to filter element clogging, worn vacuum pads, piping leakage, etc., the switch can detect and indicate an oncoming problem before failure occurs. Two independent outputs Allows the calibration of two different setpoints e.g. change of vacuum pad size requiring different setpoints, two different supply pressures requiring different pressure confirmation points. Calibration data The calibration data is stored in an EEPROM. The EEPROM is rated to keep its memory for 100,000 hours (approx. 11 years) without having power supplied. Suction filter comes as standard A G Self-diagnostic function Excessive current Excessive pressure Data error LCD: Error display Indication lights: LED (Red) RESET SET 763

LCD Readout Digital Pressure Switch Series 3/3 How to Order Operating pressure range Nil L 0 to 0.98 MPa 0 to 98 Piping specifications 01 Single mounting R 1 Note 1) /8 T1 Single mounting NPTF 1 Note 1) /8 Note 1) M5 x 0.8 female threaded. Positive pressure 3 3 Output specifications 21 22 NPN open collector 2 outputs without analog output NPN open collector 2 outputs with analog output (1 to 5 V) A Suffix Nil None D For replacement with ZX series Note 3) Compliant with piping specifications OX and OXY only. Wiring specifications Nil Grommet type (Lead wire: 0.6 m) L Grommet type (Lead wire: 3 m) C Connector type (Lead wire: 0.6 m) CL Connector type (Lead wire: 3 m) CN Without connector Analog output is only available in a grommet type. G 01 T1 0X 0XY Piping specifications Single mounting R 1 Note 2) /8 Single mounting NPTF 1 Note 2) /8 With suction filter M5 x 0.8 With suction filter M6 x 1 (Option) Output specifications 21 NPN open collector 2 outputs without analog output 22 NPN open collector 2 outputs with analog output (1 to 5 V) Note 2) Single mounting type: M5 x 0.8 female threaded. 23 NPN open collector 1 output Failure predict function without analog output 24 NPN open collector 1 output Failure predict function with analog output (1 to 5 V) 765

Series 3/3 Specifications Model 3 Positive pressure 100 3L Positive pressure 1 MPa 3 Operating pressure range 0 to 101 0 to 98 0 to 0.98 MPa Max. operating pressure Min. display unit Indicator light (2) MPa Frequency response (3) Hysteresis mode Hysteresis Window comparator mode Fluid Temperature characteristics Repeatability Power supply voltage Switch output Current consumption Error display Pressure indication Self-diagnostic function Operating temperature range Noise resistance Withstand voltage Insulation resistance Vibration resistance Impact resistance Connector type Lead wire Mass Port size Enclosure Standard Grommet type Note 1) Instant pressure supply of 0.5 MPa has no influence on the switch. Note 2) 3- - 23 24: Failure predictive output is Red. Note 3) Window comparator mode: The hysteresis is 3 digits, so separate P1 from P2 by 7 digits or more and set them. 1 digit is the minimum pressure display unit. (See the table above.) Description 1 200 (1) 1 MPa 1 0.01 N: When Green LED (OUT1) or Red (OUT2) turns on 200 Hz Adjustable (Variable from 0) Fixed (3 digits) Air, Non-corrosive gases ±3% F.S. or less ±1% F.S. or less 12 to 24 VDC ±10%, Ripple (p-p) 10% or less (With power supply polarity protection) NPN open collector 30 V 80 ma or less 25 ma or less Red light blinks. Display the error code on LCD. 3 1 /2 digits (5 mm-size numerals) Overcurrent, Overpressure, Data error Pressure during 0 clear 0 to 60 C (No dewing) 1000 Vp-p, Pulse width 1 μs, Rise time 1 ns 1000 VAC in 50/60 Hz for 1 minute between live parts and case 2 MΩ or more (at 500 VDC by megameter) betweeen live parts and case 10 to 500 Hz Pulse width 1.5 mm or acceleration 98 m/s 2 (at the smaller vibration) to X, Y, Z direction (2 hours) (De-energized) 980 m/s 2 to X, Y, Z direction (3 times for each direction) Heat-resistant vinyl electric wire, 4-wire, Cross section: 0.31 mm 2, Insulator O.D.: 1.55 mm Oil-resistant vinyl cabtire code -21, -23: 4 cores, ø3.5, Cross section: 0.14 mm2, Insulator O.D.: 1.0 mm -22, -24: 5 cores, ø3.5, Cross section: 0.15 mm2, Insulator O.D.: 1.0 mm 40 g (including 0.6 m-long lead wire) R 1 /8, M5 x 0.8, NPTF 1 /8, M5 x 0.8 R ZX ejector mounted type: M5 x 0.8 1 /8, M5 x 0.8 NPTF 1 /8, M5 x 0.8 IP40 Compliant with CE marking LCD Displays present pressure. Displays each mode. Displays error code. RE This clears the unit when an abnormality occurs. Displays 0. RESET SET Decreases the ON/OFF set point value. Used for switch to peak mode low. 766 Switches to the setting mode. Increases the ON/OFF set point value. Changed to peak mode high.

LCD Readout Digital Pressure Switch Series 3/3 Calibration Procedure Pressure Setting 2 output type 1. Input mode for set point value 2. Input set point value for OUT1 (1) 3. Input set point value for OUT1 (2) P1: Setting of OUT1 P2: Setting of OUT1 P3: Setting of OUT2 P4: Setting of OUT2 Table 1 ON OFF Output type Hysteresis mode (P1 P2, P3 P4) Hysteresis (Variable from 0) P2 (P4) Pressure Low Low P1 (P3) ON OFF (Refer to the Table 1.) 4. Input set point value for OUT2 (1) 5. Input set point value for OUT2 (2) P1 (P3) Pressure Low Low P2 (P4) SET button to complete the setting. Window comparator mode (P1< P2, P3< P4) Note) Window comparator mode (one for positive pressure is same) Hysteresis is 3 digit, so set P1 and P2 (also P3 and P4) at (Hysteresis = 3 digits fixed) Hysteresis least 7 digit. (Fixed) Hysteresis (Fixed) 1 digit is the minimum setting pressure unit. A G 1 output type with failure prediction function 1. Input mode for set point value 2. Input set point value for OUT1 (1) 3. Input set point value for OUT1 (2) P1: setting of OUT1 P2: setting of OUT2 P3: setting of failure prediction pressure EC: Number of failure prediction 4. Calibration of failure predictive pressure 5. Calibration of number of failure prediction occurrences SET button to complete the setting. Table 2 Failure prediction P3 Set pressure P1 Set pressure Low P2 (Refer to the Table 2.) Failure prediction counter Normal 1 time 2 times 3 times Occurrence number: 1 to 16 times (0 is not available for prediction.) Failure prediction will register when switches turn OFF without reaching the pressure of (P3) after switch turns ON (over P1). Output of failure detection occurs when failure prediction is counted continuously within certain preset levels. The count of failure prediction is reset when switch turns ON (over P1) and pressure exceeds the failure prediction set pressure (P3). (Example of hysteresis mode.) 767

Series 3/3 Other Functions Internal Circuit and Wiring Example Peak mode high RESET SET To display the high peak pressure (highest degree of vacuum), press the button during normal operation. The LCD displays H. To return back to the normal operation, press the button again. Circuit and connection Main circuit LED Green LED Red Tr1 D1 Tr2 D2 DC (+) Power supply + terminal Brown Out3 Analog output 1 to 5 V (±5% F.S) Gray Load impedance: 1 kω OUT1 Black Output 1 OUT2 Output 2 White Peak mode low RESET SET To display the low peak pressure (lowest degree of vacuum), press the button during normal operation. The LCD displays. To return back to the normal operation, press the button again. Regular connection Main circuit LED Green Tr1 D1 LED Red DC ( ) Supply voltage GND terminal Blue Brown Gray Black Load Load + 12 to 24 VDC Tr2 D2 White Blue RESET SET Take the following corrective solutions when errors occur. 768 Reset function Error Correction A RESET operation leads to the following results. 1) Reset will cause the following during normal operation: Peak high is cleared. Peak low is cleared. Failure prediction counter is cleared. Failure predictive output is reset. 2) Reset will cause the following when an error has occurred: Data set in setting mode will remain stored and will return to the same state as when the power is applied. (All calibration data has retained.) In the case of data error, reset the setup mode and then switch will assume normal operation. (All calibration data has retained.) Note) Reset Function does not work during setup mode. Display Description Solution Set data was changed by accident, reason unknown. OUT1 is short-circuited. Overcurrent is being applied to the load. OUT 2 is short-circuited. Overcurrent is being applied to the load. Pressure exceeding 0.5 MPa is being applied. (The pressure over rated pressure is being applied in case of positive pressure.) When performing zero clear, compared with the atmospheric pressure, pressure of more than ±0.07 MPa for 1 MPa and ±7 for vacuum is being Perform the RESET operation, and reset all data again. Turn off the power and replace the load connected with OUT1 (Black wire). Turn off the power and replace the load connected with OUT2 (White wire). Reset the supply pressure less than 0.5 MPa. (Reduce the supply pressure to below rated pressure in case of rated voltage.) Apply atmospheric pressure and then reset the switch. Connection example with a PLC at negative common terminal Main circuit LED Green LED Red Tr1 D1 Tr2 D2 Brown Gray Black White Blue How to Use Connector Hook 12 to 24 VDC + PLC Input terminal PLC Input terminal COM 1. Attaching and detaching connectors When assembling the connector to the switch housing, push the connector straight onto the pins until that lever locks into the housing slot. When removing the connector from the switch housing, push the leverdown to unlock it from the slot and then withdraw the connector straight off of the pin. With connector 0.2 to 0.33 mm 2 Max. coating O.D. ø 1.7 mm Socket Part no. DXT170-71-1 Connector DC polarity indicator Lever Pin Slot Housing 2. Crimping of lead wires and socket Strip 3.2 to 3.7 mm of the lead wire end, insert each stripped wire into a socket and crimp contact it using special crimping tool. Be careful that the outer insulation of the lead wires does not interfere with socket contact part. (Crimping tool: DXT170-75-1) 3. Attaching and detaching lead wires with sockets Attaching Push the socket into the square holes of the connector (with +, 1, 2, indication), and continue to push the sockets all the way in until they lock by hooking into the seats in the connector. (When they are pushed in their hooks open and they are locked automatically.) Then confirm that they are locked by pulling lightly on the lead wires. Detaching To detach a socket from connector, pull out lead wire while pressing the socket's hook with a stick having a thin tip (about. 1 mm). If the socket will be used again, first spread the hook outward.

LCD Readout Digital Pressure Switch Series 3/3 How to Replace Filter Element Replace the filter element when clogging causes deterioration of the adsorption force or slow response time. (Element part number: ZX1-FE) Confirm that the filter gasket is seated in the groove and then reassemble the parts. (Filter gasket part no.: ZX1-FG) Filter case Filter element (ZX1-FE) Filter gasket (ZX1-FG) Gasket groove Regarding the filter case Caution 1. The case is made of polycarbonate. Therefore, do not operate it in an environment that is exposed to chemicals such as thinner, carbon tetrachloride, chloroform, acetic ester, aniline, cyclohexane, trichloroethylene, sulfuric acid, lactic acid, or water-soluble cutting oil (alkalinic). 2. Operate it away from direct sunlight. A G 769

Series 3/3 Dimensions/Switch Only Grommet type I Z 01 T1 SE3- - 30 30 8.5 3.5 39 10 (3000) 20.5 8.5 3.5 40.5 (3000) 20.5 RE Lead wire length 600 2 x ø3.5 Mounting hole 13 01: R 1/8 T1: NPTF 1/8 M5 x 0.8 Connector type I Z 01 T1 SE3- - C RE Lead wire length 600 2 x ø3.5 Mounting hole 13 01: R 1/8 T1: NPTF 1/8 M5 x 0.8 770

LCD Readout Digital Pressure Switch Series 3/3 Grommet type 7 3-0X - 50.6 20.5 supply port pad connection port RE Pneumatic circuit Lead wire length 600 (3000) 51.5 58 3-0X - -D PV 8 10.25 supply port 0X: M5 x 0.8 0XY: M6 x 1.0 10 22.6 2 x ø3.3 Mounting hole 6.5 18 10.2 5.75 pad connection port 0X: M5 x 0.8 0XY: M6 x 1.0 A G Connector type 3-0X - C 7 50.6 20.5 supply port pad connection port RE Pneumatic circuit 50 10 Lead wire length 600 (3000) PV 8 18 10.2 58 3-0X - C-D 10.25 supply port 0X: M5 x 0.8 0XY: M6 x 1.0 10 22.6 2 x ø3.3 Mounting hole 6.5 5.75 pad connection port 0X: M5 x 0.8 0XY: M6 x 1.0 771