Cooling. Highly efficient cooling products for any IT application. For More Information: (866) DATA CENTER SOLUTIONS

Similar documents
Close-coupled cooling

InRow Chilled Water. Up to 70kW. Close-coupled, chilled water cooling for medium to large data centers. Row-Based Cooling.

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

APC APPLICATION NOTE #146

Reducing Data Center Cooling Costs through Airflow Containment

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Rittal Cooling Solutions A. Tropp

Rack cooling solutions for high density racks management, from 10 to 75 kw

Thermal management. Thermal management

One Stop Cooling Solution. Ben Tam Business Development Manager

Total Modular Data Centre Solutions

APC by Schneider Electric Elite Data Centre Partner

APC APPLICATION NOTE #114

INNOVATE DESIGN APPLY.

INNOVATE DESIGN APPLY.

CHILLED WATER. HIGH PRECISION AIR CONDITIONERS, FROM 7 TO 211 kw

Power and Cooling for Ultra-High Density Racks and Blade Servers

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Close Coupled Cooling for Datacentres

Combining Cold Aisle Containment with Intelligent Control to Optimize Data Center Cooling Efficiency

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Current Data Center Design. James Monahan Sept 19 th 2006 IEEE San Francisco ComSoc

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

IT Air Conditioning Units

MSYS 4480 AC Systems Winter 2015

Switch to Perfection

Mission Critical Facilities & Technology Conference November 3, 2011 Cooling 101. Nick Gangemi Regional Sales Manager Data Aire

Next Generation Cooling

Variable Density, Closed-Loop, Water-Cooled Data Center Solution

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Precision Cooling Mission Critical Air Handling Units

Using CFD Analysis to Predict Cooling System Performance in Data Centers Ben Steinberg, P.E. Staff Applications Engineer

Ten Cooling Solutions to Support High-density Server Deployment. Schneider Electric Data Center Science Center White Paper #42

Rethinking Datacenter Cooling

Liebert DCW CATALOGUE

STULZ Micro DC. with Chip-to-Atmosphere TM Liquid to Chip Cooling

Virtualization and consolidation

ENCLOSURE HEAT DISSIPATION

PEX+ High Efficiency, Low Operating Cost Precision Solution for Data Centers

Scalable, Secure. Jason Rylands

A) Differences between Precision and Comfort Cooling Here are the major differences exist between precision air conditioning and comfort systems.

Datacenter Efficiency Trends. Cary Roberts Tellme, a Microsoft Subsidiary

IT COOLING AIR CONDITIONERS FOR HIGH DENSITY RACKS AND BLADE SERVERS. RACK COOLING SOLUTIONS FOR HIGH DENSITY RACK MANAGEMENT, FROM 4 TO 75 kw

Industry leading low energy evaporative fresh air cooling.

Power & Cooling Considerations for Virtualized Environments

Recapture Capacity for Existing. and Airflow Optimization

COOLING SOLUTIONS. SmartRack Close-Coupled Cooling for IT Environments

APC InfraStruXure Solution Overview

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

Reference Design Quicktour Design Summary

84 kw, Tier 3, Direct Expansion, 937 ft 2

HIGH DENSITY RACK COOLING CHOICES

Reducing Energy Consumption with

Product Brochure DENCO Close Control Units Row-DENCO. High Density Cooling for Data Centres

PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

<Insert Picture Here> Austin Data Center 6Sigma DC CFD Model

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

Moving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet

The Energy. David L. Moss Dell Data Center Infrastructure

Impact of Air Containment Systems

Ecoflair Air Economizers

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions

DATA CENTER AIR HANDLING COOLING SOLUTIONS

Data center cooling evolution. The hottest way to save energy. Lucio Bustaffa: Product Development Manager BlueBox Group

Liebert DCW Family Chilled Water-Based High Density Cooling For The Data Center. Precision Cooling For Business-Critical Continuity

Liebert Economizer Cooling Solutions Reduce Cooling Costs by up to 50% Without Compromising Reliability

ZTE ZXCR Series DX In-Row Air Conditioning Product Description

New Techniques for Energy-Efficient Data Center Cooling

To Fill, or not to Fill Get the Most out of Data Center Cooling with Thermal Blanking Panels

APC InRow Cooler Prototype Initial Report - Test Setup Verification. H. Coles, S. Greenberg Contributing: J. Bean (APC) November 18, 2011

AisleLok Modular Containment vs. Legacy Containment: A Comparative CFD Study of IT Inlet Temperatures and Fan Energy Savings

Modular, scalable, high-efficiency power protection for data centers

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

ACFD12-T ACFD12-B. Technical Data

APC APPLICATION NOTE #126

Survey and Audit Service Schedule. Airflow and Thermal Imaging Survey Service Schedule. Data Centre Solutions Expertly Engineered

A Green Approach. Thermal

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

Deploying High-Density Zones in a Low-Density Data Center

HIGH DENSITY DATACOM INTEGRATED COOLING SYSTEM.

Google s Green Data Centers: Network POP Case Study

Where s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden

Optimizing Cooling Performance Of a Data Center

Cooling Solutions & Considerations for High Performance Computers

Liquid Cooling Package LCP Cooling Systems

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

SmoothAir Modular Precision Cooling

Liebert XD. Cooling Solutions For High Heat Density Applications. Precision Cooling For Business-Critical Continuity

Efficiency of Data Center cooling

Powering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM

BENEFITS OF ASETEK LIQUID COOLING FOR DATA CENTERS

Data Center Trends: How the Customer Drives Industry Advances and Design Development

Liebert. AFC from 500 to 1700 kw. The Adiabatic Freecooling Solution with Top-Tier Availability

Digital Realty Data Center Solutions Digital Chicago Datacampus Franklin Park, Illinois Owner: Digital Realty Trust Engineer of Record: ESD Architect

Aquaflair. Uniflair TRAC, TRAF and TRAH. Air-cooled chillers, free-cooling chillers and heat pumps with scroll compressors.

Your Solution For Energy and Cost Savings. McQuay Packaged Chiller Plant

Energy Logic: Emerson Network Power. A Roadmap for Reducing Energy Consumption in the Data Center. Ross Hammond Managing Director

DATA CENTER LIQUID COOLING

Green IT and Green DC

Transcription:

Cooling > Highly efficient cooling products for any IT application. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com

End-to-End Cooling Solutions from the Closet to the Data Center Row Cooling Room Cooling Customer Challenges Growing pains make it difficult for customers to add on to their cooling needs Future proofing. Achieving efficiencies while cooling high density heat loads to ensure 7x24 Data Center availability Key Considerations Ability to adapt to increasing and unpredictable power densities Elimination of hot spots within the room and the rack Minimize Total Cost of Ownership Ensure stable inlet temperatures to IT equipment at all levels of the rack Flexibility to easily add cooling as demand increases Why is APC the right choice? Proven Reliability. Install base in the millions Global provider of air distribution, portable cooling, row based cooling and perimeter air conditioning for all IT equipment cooling needs Scalable solutions range from 1 to 30 kw per rack Improved efficiency and reduced operating costs through the use of variable speed fans, intelligent controls, and capacity modulation Intelligent monitoring and dynamic controls system to adjust to fluctuating IT heat loads and airflow requirements Ease of use with integrated management for multiple platforms Rack Cooling Target Applications & Environments The Wiring Closet and Server Room are the fastest growing and rapidly changing environments. New applications and virtual platforms continually challenge IT managers to match their infrastructure to their growing business needs. The Data Center, which is on a constant path towards gaining efficiencies, continues to be a focus for better suited cooling.

Room Cooling Portable to perimeter cooling and air distribution for flexible room level control One of the challenges in IT infrastructure design is planning for all of the unknown variables that will happen through the life of the IT environment. Because things change so quickly, variables like power density, energy costs, and equipment footprint can impact the effectiveness and life of the IT infrastructure. Having the ability to deliver cooling at the room level provides flexibility by ensuring that cooling is available anywhere. To solve this problem, APC offers a complete line of Room Cooling which includes perimeter, portable, and air distribution products. Room Cooling products offer flexible cooling solutions perfect for lower density racked and non-racked IT loads. For the closet / server room environment, Room Air Distribution products can be used as a cost effective solution to provide ventilation and easily address lower density heat problems. When dedicated cooling is required, portable self contained units offer quick deployment to address those areas where cooling wasn't initially anticipated. For small to large data center environments, air, water, glycol, multi-cool, and economizer direct expansions units are available to address virtually any size IT environment. The InRoom Chilled Water and Direct Expansion products are assemble to order solutions that offer a choice of five cabinet sizes and capacities, utilize variable fan technology, as well as intelligent control for the best performance. This suite of products is easily serviced, offers the smallest footprint with the highest capacities, while running 10% more efficiently than traditional, beltdriven perimeter units, thereby reducing the overall total cost of ownership. APC offers all types of remote heat exchangers to meet the requirements of any data center configuration. Room Cooling Products InRoom Chilled Water Perimeter, chilled water cooling for medium to large data centers. InRoom Direct Expansion Perimeter and portable cooling for wiring closets, server rooms, and data centers Room Air Distribution Air ventilation for wiring closets InRoom CW InRoom DX NetworkAIR PA Wiring Closet Ventilation Unit Up to 150kW Up to 86kW 3kW 1.5kW Up to 3kW of heat removal Chilled water Air-cooled, watercooled, glycol, multicool, and economizer Self-contained Network Manageable On/off Scheduling Dry Contact Outputs Intelligent Controls EC Direct Drive Fans Humidity Control Automatic Restart Ease of Mobility (Casters) Ducted Intake/Exhaust On/Off Control Fault-tolerant Fans Multiple Mounting Methods

Rack Cooling Dedicated cooling and air distribution for single racks or hot spots A rack-oriented design allows cooling capacity (and redundancy) to be targeted to the actual needs of a specific rack. APC offers a complete line of air distribution products as well as a series of completely contained, rack integrated cooling products. Rack mounted air distribution products solve inadequate air distribution problems within a rack enclosure. These fan products work with existing cooling products to either provide cool air to or remove heat from the rack enclosure. These hot spot problem solvers ensure uniform inlet temperatures to the IT equipment. The InRow SC Systems combine InRow Cooling and Rack Air Containment to offer a flexible, easily deployable solution for almost any environment. Available in three configurations, these fully contained systems offer intelligence that enables network manageability, as well as self-monitoring components that enable the highest level of availability. Combining the row-based cooling architecture with containment of airflow, further increases the predictability, efficiency, and capacity of the system. With InRow SC Systems, airflow paths are completely defined and totally immune to any installation variation or room constraints. Rack Cooling Products Rack Air Distribution Air distribution for power dense enclosures and low pressure areas InRack Direct Expansion Rack integrated cooling system for environmentally controlled spaces Rack Air Distribution Unit Rack Side Air Distribution Unit Rack Air Removal Unit InRow SC System Up to 1.5kW of air distribution Up to 1.5kW of air distribution Up to 16.5 kw of heat removal Up to 7kW of cooling Fault-tolerant Fan System Active Response Controls Fan Control Switch Variable Speed Fans Raised Floor Duct Turning Vane Dual A-B Power Inputs Network Manageable Hot Swappable Fans Zero White Space Solution Zero U Design Ducted Exhaust Real-time Capacity Monitoring

Row Cooling Energy efficient cooling from low to high density racks and zones APC s InRow cooling products were designed to be closely coupled with the IT heat load in order to prevent hot air recirculation, and improve efficiency and cooling predictability. Data center operators looking to improve efficiency or deploy high density will benefit from the modular design of the row-based products enabling both new and existing facilities to pay as they grow. The intelligent controls in these units actively adjust fan speed and cooling capacity to match the IT heat load to maximize efficiency and address the dynamic demands caused by virtualization in today s IT environments. These products offer a 30% increase in efficiency over traditional cooling architectures. To further improve efficiency InRow products can be combined with our Thermal Containment solutions. Thermal Containment maximizes the effectiveness of InRow cooling solutions from low to high density racked IT loads. Available in rack or aisle configurations, these products were designed to completely separate the supply and return air paths of the IT equipment. This air separation ensures the warmest possible air is being returned to the InRow cooling units, which increases the efficiency and capacity of the cooling system. Row Cooling Products InRow Chilled Water Close-coupled, chilled water cooling for medium to large data centers. InRow Direct Expansion Close-coupled, air-, water, and glycol cooling for closets, server rooms, and data centers InRow RC InRow RP InRow SC InRow RD InRow RP 300mm 600mm 300 mm 600mm Up to 30kW Up to 60kW Up to 5kW Up to 10kW Up to 36kW Chilled water Self-contained Air-cooled/fluid-cooled Air-cooled Hot Swappable Fans Humidity Control Hot Swappable Fans Humidity Control Active Response Controls Network Manageable Real-time Capacity Monitoring Variable Speed Fans

Row Cooling Increasing efficiency, predictability, and capacity with thermal containment Improved cooling techniques are essential to extend the life of existing data center facilities. The use of containment ensures that equipment temperatures can be better managed. The addition of containment with InRow cooling units, further increases the energy saving by an additional 20%. Thermal Containment products maximize cooling effectiveness for low to high density racked IT loads. Available in rack or aisle level configurations, these products are designed to completely separate the supply and return air paths of the IT equipment. Ideal for any IT environment, the air separation ensures the warmest possible air is being returned to the InRow cooling units, which further increases the efficiency, capacity, and predictability of the cooling system. Thermal containment is available for 300mm, 600mm, 750mm wide NetShelter Racks, UPS/PDU, and InRow Cooling products. Front containment can also be added to the rack configuration for additional isolation and noise dampening. Features and Benefits Warmer intake temperatures increases cooling unit capacity Removal of heat ensures that the supply temp has little to no mixing resulting in a predictable cooling design Allows for mixed density racks to exist in the same environment without overcooling Reduction or elimination of moisture removal Redundancy achieved with less equipment Shared cooling capacity

Cooling Distribution and Piping Centralized distribution for rapid deployment of Row Cooling While chilled water cooling has remained as one of the most popular and efficient cooling mediums, high density heat loads has prompted the need to bring the cooling closer to the IT equipment. This combination has driven the need for a highly reliable distribution and piping system. Chilled Water Distribution products provide centralized chilled water balancing and distribution to InRow cooling units within the IT environment. Available in a single 750mm rack footprint, these products are designed to provide a centralized location for the balancing and isolation of InRow RC 300mm Chilled Water cooling units. Optionally, APC offers Pex-Al-Pex piping to deploy a seamless and flexible piping solution that connects the chilled water distribution product to the InRow cooling units. Pex-Al-Pex dramatically reduces the risk of leaks with a multi-layered composite tubing consisting of an aluminum tubing sandwiched between inner and outer layers of cross-linked polyethylene. Chilled Water Distribution products allow for quick deployment and enable a flexible infrastructure to grow and change with minimal labor and installation costs. Cooling Distribution and Piping Products Chilled Water Distribution Flexible chilled water and glycol distribution systems for InRow cooling units Cooling Distribution Unit PEX-AL-PEX Works with up to 12 InRow RC (300mm) units Available in 100 and 300 feet lengths Flexible Piping Seamless Piping Coolant Isolation

Heat Rejection Outdoor heat removal to support Room and Row Cooling With the exception of the self-contained product offerings, there is an essential component to the cooling system outside the IT environment. The function of this component is to transfer heat to the outside atmosphere. Cooling equipment in an IT environment can be deployed using three remote methods of heat rejection. The selection of the appropriate configuration for a particular installation is affected by the existing facility infrastructure, the total power level of the installation, the geographical location, as well as the physical constraints of the building. Heat Rejection Chillers Water chilling plants for row and room cooling products Fluid Coolers Heat removal designed to use water or glycol for row and room cooling products Condensers Specifically engineered heat rejection for row and room cooling products 50-220kW 10-86kW 10-86kW Works with Multiple Cooling Units One to One Unit Configuration Microprocessor Controller Direct Drive Motors Variable Speed Fans Scroll Compressor Fixed or Variable Speed Fans Flooded Head Pressure Controls Optional Storage Tank Dual Power Input for Pumps

A Hybrid Approach Cooling the data center using Room, Row, and Rack Cooling All data centers are designed for a common purpose of providing a secure and reliable structure for housing IT equipment. While these data centers are united in a common design goal at a very high level, they are very diverse in nearly every other way. Each data center has unique demands that are driven by individual business needs. Even into the operational phase, the uniqueness of the data center continues to change with the rate of expansion, density, and layout, to name a few. The design will take into consideration parameters for operation like density, peak vs. average load, and other criteria for day to day operation. It is, however, very difficult to predict exactly how the data center will look over time. With a design life of 10-15 years for the data center and IT managers refreshing their equipment every 2-4 years, it is likely that the data center will change significantly over the years. With all the uncertainty of the data center, choosing a single cooling solution that will meet the data center needs today and in the future is a difficult task. For this reason, most data centers will require a hybrid of multiple cooling solutions to address their unique requirements. To make this task easier, APC cooling solutions are available in multiple architectures with modular options for easy expansion. Room, Row, and Rack Cooling solutions provide a variety of options to cool large areas or target cooling where it is needed. Starting at the room level, perimeter units are available to provide cooling to low density racks, lighting, people and other non-racked loads such as storage equipment and single enclosure server systems. Room cooling also serves to provide moisture control for the entire space. Since the data center is likely to change over time with IT refreshes, a room cooling architecture that adequately cooled the data center in the beginning, may not handle the diverse heat loads in later years of operation. To increase the effectiveness of the installed system without an architecture change, rackbased solutions can be deployed with the changing topology of the IT gear to enable greater density and efficiency as needed. The best choice for rack based IT loads is a row cooling approach due to its energy efficient advantage. This close-coupled cooling method allows the heat removal to be matched to the heat generation for energy savings at any density. Removing the heat at the source and eliminating mixing of hot and cold air streams allows the system to predictably control IT inlet temperatures. DATA CENTER SOLUTIONS For More Information: (866) 787-3271 Sales@PTSdcs.com For additional information, visit www.apc.com 2008 American Power Conversion Corporation. All rights reserved. Other trademarks are property of their respective owners. Specifications are subject to change without notice. End to End Cooling Solutions Last Updated on June 16, 2008 132 Fairgrounds Rd. West Kingston, RI 02892 USA Call: 800-800-4APC Fax: 401-789-3710 e-mail: esupport@apc.com