MSS-UP200-GSM Single Dwelling GSM Intercom Unit. Operation Manual. [Ver /5/2015]

Similar documents
Comsec Protection Systems

UP200-GSM Intercom and access control unit operating on mobile GSM network

UP100-GSM. GSM based intercom and access control. Installation and user manual

ecoline GSM Adapter INSTALLATION AND APPLICATION MANUAL for module version v2.0 and higher Document version:

GPRS ADAPTER INSTALLATION AND USER MANUAL. for module version v2.24 and higher

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

MobilGate - 128d. 1. Operation of MobilGate-128d. Gate and barrier control GSM module with 2 inputs and 2 outputs for 128 phone numbers

Conversion of Contact ID event codes sent by alarm control panel via GSM and PSTN channel to SMS messages

SS91A-M GSM DOOR PHONE (ACCESS CONTROL SYSTEM)

Installation Manual & User Instructions

Installation Manual & User Instructions. MultiCom 500

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Installation Manual & User Instructions. MultiCom 100 / 500

Installation Manual. GSM-3V/AB & ABK V3.5 (1200 keypad) Wiring. Important Notes: SIM card. Installation

Verify with your service provider that their Mini SIM card will work with GSM / 3G GSM type modems before purchasing their Mini SIM card.

A1000 GSM ALARM DEVICE

GPRS Pager 3 INSTALATION AND USER MANUAL

MobilTherm 2ad. 1. How the interface works: GSM temperature alarm module with auxiliay inputs and relay outputs

Aristel AN4004 GSM FIXED WIRELESS TERMINAL MANUAL V3.1. This manual contains important information. Please read before using the equipment.

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

MobilSwitch-5c. 1. Operation of the GSM device: Multi channel GSM signaling and remote control unit with analog, digital, counter inputs

MobilSwitch - Micro. 1. Operation: General purpouses GSM remote signal and remote control modules with 2 inputs and 2 relay outputs

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

USER S MANUAL FDC-250

NEOS3000A GSM Least Cost Wireless Router

INTERQUARTZ. Doorphone ID 201 Doorphone ID 202 Doorphone ID 204. User manual

STD Simple Telemetry Application. Owner s Manual

MANUAL DOOR INTERCOM 3G AUDIO KEYPAD INTERCOM (ACCESS CONTROL SYSTEM) For 200 Apartments. For your protection, read these instructions completely

The Packs Infotel. GSM Converter V2. Installation Manual V7

Access Control for Houses 2 Wires Connection Doorline DR-200-SET Surface Mount Doorline DR-200-AV-SET Flush Mount

GSM Door / Gate Intercom Entry System For 123 Units max.

Link GSM idp Manual v1.0

Mobil Switch-Nano. 1. Operation: Industrial grade GSM signalling and remote control module with common input and relay output

An intercom completes any access control system by providing a means for the user of screening visitors before granting access, thereby significantly

SMS Commander Manual

HUAWEI FT2260 Home Phone Connect Quick Start

smartentry Wireless Video Doorphone User Manual

Intercom User Manual v1.1

: DOOR ENTRY UNIT USER MANUAL EIS-LCD. Programming Software

GSM PAGER VT 21. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC,

A1400 GSM Temperature Alarm USER MANUAL A1400-REV FW-A1400v2.94. ERBAŞ TEKNOLOJİ Innovative Solutions. 1

Installation Manual & User Instructions

8848 GSM FWT (GATEWAY) USER S MANUAL

Quick Guide for SD-902 Door phone Intercom

SS-10 3G USER MANUAL FIXED CELLULAR TERMINAL. DOC. NO: SS-10 3G-14 (Rev. 01) Page 1 of 20

Decode Data Communications GSM Key - User's Manual - Belgrade, November 2010.

GSM communicator GD-06 Allegro Complete manual

GSM GATE INTERCOM WITH KEYPAD Control your gate with your mobile phone

ProLine GSM. Installation manual

GM-900 GSM/GPRS modem. Application manual

GSM GATE VT 10. version 5.4 and higher. Installation manual. VARIANT plus, spol. s.r.o., U Oburky 5, TREBIC, Issued on May 16, 2007

GC 055. GSM Remote Monitoring. Operating and installation instructions

GSM Unit PU from software version Connecting cable RJ 12/ RJ 12, enclosed

PS 430 FOUR CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

page A.0240 Full_Product_catalogue_ BM.indb 110

WiLARM-ContactID GSM Module Installation Guide Version: 2.0

Chapter 1 Overview 2. Chapter 2 Website overview 4. Chapter 3 Customers 9. Chapter 4 Complex Wizard 11. Chapter 5 Switching to a customer 20

SC-688 GSM FWT USER S MANUAL

F3102 / F3107 / F3110 / F3115 / F3210 / F3215 PN: 86085K K

PS 230 DUAL CHANNEL REMOTE SPEAKER STATION. User Manual. January 2017 V1.0

User s Guide. Nokia is a registered trademark of Nokia Corporation, Finland Nokia Mobile Phones. All rights reserved.

PLEASE READ BEFORE INSTALL. ECGO-GKP Cellular Telephone Entry

Wireless Key fob, Key pad & Receiver Range

Aristel Networks Pty Ltd. All Round Cabling Solutions NEOS3003-3G01. Operating Manual * NEOS G01

ProCon GSM INSTALLATION AND APPLICATION MANUAL. ProCon GSM manual. .gsm-komunikatorji.com. for module version 1.4

Apartment Intercom. User s Manual Ver 2.0. The K6S is a new type fashion. designed access control system, it. supports dial to open the door with

GPS Vehicle and personal location tracker

GSM HOME SECURITY SYSTEM

SOLO KP SOLO KP LCD COMPACT MULTI-APARTMENT GSM DOOR ENTRY UNIT USER MANUAL

Gate controller GC1000

: DOOR ENTRY UNIT. Programming Software USER MANUAL

BS 15 BASIC SERIES USER MANUAL FOR THE SINGLE CHANNEL BELTPACK CONTENTS

GPS Child Tracking Device User manual

N-8000 SERIES IP INTERCOM SYSTEM

M170 USER'S / INSTALLER'S MANUAL V1.1 REV. 11/2016

RUKRA GSM/PSTN INTERFACE_ENG_V1 ARTICLE NUMBER: RK Read this manual carefully before you start the installation or programming

GSM-X. Communication module. Quick installation guide. Full manual is available on Firmware version 1.02 gsm-x_sii_en 08/18

YourBell. Version 5.00 INEXPENSIVE, RELIABLE USB PRODUCTS.

GSM AD05 Slave GSM Auto Dialer- Instruction Manual

Installation and Configuration Quick Guide GoRugged M1000 MP

ZD-VT1 User Guide. ZENDA GPS Tracker ZD-VT1 User Guide

SOLO NX EXT COMPACT GSM DOOR ENTRY UNIT WITH 1, 2 or 4 CALL BUTTONS

2 WIRE video door entry system

jcmtechnologies GSM-CARD/VGSM-CARD user s manual communications card

NGP 822. Front view. 4 or 8 extensions or 2 cell phone interfaces or 2 interfaces of analogical lines. Automation and security

Installation & User Manual For. MultiCOM Cellular Intercom System

MDVR 800 QUICK START GUIDE

GPS Vehicle and personal location tracker

Wireless Digital Video Doorbell

GSM SECURITY AND CONTROL SYSTEM ESIM021

User s Guide for 3G/GPS Camera

D45 System. 7 touch screen handsfree internal unit. Front & side views

SMS Transceiver V3 User manual

Voice Fax. User Manual

2 WIRE INTERCOM SYSTEM

C e l l C O M. G S M I n t e r c o m

2.4GHz Digital Wireless Colour Video Door Phone User Manual

GSM GATE VT 10. version 7.0 and higher. Installation manual. VARIANT plus, spol. s.r.o., U Obůrky 5, TŘEBÍČ. Issued on January 10, 2012

NEOS3000A GSM Least Cost Wireless Router

Communi-Cell Communicator Nokia Version

Transcription:

[Ver. 1.0 2/5/2015]

INTRODUCTION The MSS-UP200-GSM is a GSM intercom unit which can phone the owner s mobile or landline phone. By pressing the call button on the intercom, it makes the voice connection in a few seconds, just like when talking via a conventional intercom system. This way it is possible for the owner to receive visitor s calls and talk to them at anytime and anywhere, even when not at home. The unit does not need any special installation or complicated wiring; it needs power only and an active SIM card.the unit brings communication between the owner and visitor to a higher level and so improves the traditional solution, which can only connect between the gate and the house. FUNCTIONS Wireless intercom with 2 pushbuttons (for main house and outbuilding) Even 2 phone numbers can be assigned to each pushbutton (set as primary and secondary) Gate control function by free call, 100 user phone numbers can be configured The electric strike can be controlled using the phone s keys during a conversation, or on the scene using an external pushbutton. SMS forwarding (e.g. to forward the balance information of pre-pay SIM card) Simple configuration via USB using the PC software found in the intercom Remote configured by SMS message FEATURES Compact design, all functions on 1 panel Power voltage range 9-30V 1 contact input 1 relay output, max load: 5A@30V 1 voltage output with short circuit and overcurrent protection, max power: 1A@ Programming port: mini USB B type Communication: GSM 900/1800 MHz (2G) Network independent, accepts any SIM card Operating temperature: -30 C / +60 C Protection: IP54 APPLICATION AREA Modern solution for wireless intercom system (private homes, resorts, offices, premises) Remotely controlled access control unit Keyless door opening Garage door opening/closing by phone Emergency call unit Info columns ADVANTAGES No missed clients or visitors, since the intercom unit calls the owner s mobile phone, no matter where the owner is. On call, the owner can let in the guest, client or courier remotely. In case of absence, burglary attempts can be prevented by simulating an apparent presence. Fast and easy installation, easy configuration using a PC. Possibility for communication from any fixed place.

OPERATION Visitor mode When the visitor pushes the call button, the device initiates a voice call to the configured phone number. If the called party accepts the call, communication is established for the configured duration. During the call, the connection cannot be interrupted, even by making a call to the device, or by pressing the button again. The call is ended automatically when the configured communication time expires, or the called party can hang up at any time on his/her phone. The call is ended automatically if the called party does not answer or is not available. A new call is initiated only if the button is pressed again. Listen-in mode The intercom unit can be called from the telephone numbers assigned to the telephone s push buttons. If the call is initiated from any other telephone number, the intercom rejects it. In this case the unit accepts the call without ringing and the voice connection establishes. The call can be ended on the caller s phone or by pressing the call button on the unit. If the call is initiated from a phone number which is configured in the unit as gate opener number, the device will consider the call as a gate opening call. In this case voice connection is not established, but the relay output is activated. Controlling the relay output The RELAY (normally open, NO) output can be controlled as follows, depending on the usage: controlling using a free call: on incoming call, after identifying the caller ID, the unit rejects the call and activates the output e.g. garage door or barrier opening, for which max 100 user phone numbers can be configured controlling using the pushbutton: the relay activates when the call button is pushed e.g. possibility to connect an existing door bell controlling using the INPUT contact input: the relay activates on external contact e.g. garage door opening or closing controlling using the phone s keys: while on a call by pressing 2# of the phone s numbered keys the relay activates for the configured time period ATTENTION: The RELAY and OUT+ outputs are activated in parallel and independently from each other by both menu items, the Control of outputs and the Gate control. Please take this into consideration when planning the usage! Controlling the voltage output The OUT+ voltage output can be used for the direct control of an electric strike as follows: controlling using the pushbutton: the output activates by pressing the pushbutton controlling using the INPUT contact input: after activating the input, the output activates for the configured time period controlling using the phone s keys: while on a call by pressing 1# of the phone s numbered keys the output activates for the configured time period The output voltage is almost equal with the supply voltage, which provides easy usability with 12VDC or 24VDC systems. The output is protected against short circuit and overcurrent, thereby the output turns off upon overcurrent and becomes operable again after the termination of the fault. Forwarding incoming SMS messages The unit forwards the SMS messages received on its SIM card (e.g. balance information in case of a prepaid card) to the configured phone number. After forwarding, the received message is deleted from the SIM card. If there is no phone number configured, the unit deletes the incoming messages without forwarding. Status LED indications LED GSM OK ERROR CONNECTING Color green red green Is lit after connecting to the GSM network and reaching the sufficient GSM signal. The sufficient signal is: 10 (on 0-31 scale) Is lit continuously if the device cannot connect to the GSM network. Possible reasons: - the GSM antenna is faulty or is not connected - the SIM card is not inserted, - or the PIN code request is not disabled, - or the SIM card is faulty. Communication in progress. A call or conversation is in progress. OUT+ red Voltage output activated RELAY red Relay output activated

SETTING WITH MS WINDOWS APPLICATION The intercom unit parameters (phone numbers, controls) can be configured using the Intercom configurator software found on the internal storage of the device. You can run the program directly from the unit s drive after connecting to USB (Widows XP, Windows 7 and Windows 8 compatible). Connect the USB port of the GSM Intercom to the PC using the supplied cable and run the Intercom configurator software! Important note: in most cases the power of the USB connector is only sufficient to make the settings; therefore, it is necessary to connect an external power for the tests of calls!

Administration operations These menu items serve for reading, writing, saving etc. the settings. Using the functions displayed in the picture below, it is possible to read and write the unit s memory and the settings, as well as save settings to PC or open and edit a file with the existing settings. The procedure to be followed in all cases: 1. By connecting to the PC via USB and clicking on Read button, the software reads and displays the intercom s settings. 2. After editing the settings and clicking on Write the unit uploads the date to the intercom and starts operating. In case of an unsuccessful call (e.g. if the called number is not available or the call is not accepted), calling the secondary phone number can be done by pushing the button again (within 60 seconds). If the Automatic option is enabled, then the unit calls the secondary phone number if the primary fails without having to push the button again. Control of outputs The two outputs of the unit can be controlled by multiple configured events. You can choose the activation event according to the usage. It is also possible to save data to the PC. Buttons Read Click to read and displays the settings from the unit. Write Click to write the settings to the unit s memory. Save Click to save the settings to file. Open Click to open saved settings from file. Firmware Click to update the intercom s firmware. SIM PIN Insert the PIN of the SIM card that is used in the intercom OUT: The voltage output, e.g. for direct control of an electric lock. RELAY: The relay contact output, e.g. for garage door control. Setting: 1. To enable control, it is necessary to tick the chosen output or outputs. 2. At the next step you need to select the starting event which will activate the output. 3. Lastly the default control needs to be set, where NO= OFF, NC= ON by default. In case of OUT NO= 0V, NC= power. In case of RELAY NO= break, NC= short-circuit At control the output changes state for the given time period. General settings The intercom unit calls the phone numbers entered here when the appropriate button is pressed. If both phone numbers are set to any button, the unit calls the primary phone number first, and if the call is successful, it ignores the secondary telephone number.

Ring time (10-120 sec) The maximum time allowed for ringing from pushing the call button. This function is useful to avoid switching to voicemail. Call time (10-600 sec) The maximum time allowed for a call initiated from the intercom. Gate control When calling the intercom from the phone numbers specified here, control of the output or outputs assigned to the given phone number is performed. The incoming call is not accepted, thereby this function works with free calls. Maximum 100 user phone numbers can be added. Status information Displays information about the switching state of the peripherals and the actual status of the mobile network. State messages The messages shown in this window give information about the internal operation of the unit. This helps in identifying an internal process, an incorrect configuration or other malfunction. decrease the value of the microphone sensitivity to stop echoing. The same way, if the value of microphone sensitivity is increased then decreasing the volume can be the solution to suppress echoing Backlight brightness light (0-10), default value: 5 Gate control When calling the intercom from the phone numbers specified here, control of the output or outputs assigned to the given phone number is performed. The incoming call is not accepted from the configured telephone number, so this function operates with a free call. Maximum 100 user phone numbers can be added. Status information The question marks placed next to the settings in the Intercom configurator give assistance to the parameter settings of the given section. OUT active time (1-120 sec, monostable) The voltage output activation time. RELAY active time (1-120 sec, monostable) The relay contact output activation time. SMS forward Forwards the SMS messages received on the unit s SIM card to the specified phone number, e.g. balance information received from the GSM service provider. It is recommended to configure this in case of using a pre-paid type SIM card. Microphone sensitivity (5-15), default value: 13 the change in settings become valid in next call progress Volume (10-100), default value: 35 the change in settings become valid in next call progress Attention: By increasing the default values of the microphone and speaker settings, echo effect may occur and increase! If the value of volume is increased it is necessarey to Displays information about the switching state of the peripherals and the actual status of the mobile network. Intercom information Displays the module type and the firmware version. Inputs Displays information on the state of the intercom s buttons (upper and lower) and shows the state of the external control input (INPUT). GSM network Displays the GSM provider and the value of the GSM signal (0-31) The appropriate GSM signal is minimum 12. Outputs Displays the state of the relay and voltage output control.

State messages The messages shown in this window give information about the internal operation of the unit. This helps in identifying an internal process, an incorrect configuration or other malfunction. The question marks placed next to the settings in the Intercom configurator give assistance to the parameter settings of the given section. SETTING WITH SMS COMMANDS Configuration of the unit is possible by sending the appropriate commands in SMS to the module s phone number. It is possible to send more commands (settings) in the same SMS, but the length of the message must not exceed 140 characters! Each message must begin with the password using the PWD=password# command and each command must end with # character, or the module will not apply the modifications. The following table contains the configuring and query commands: Configuration commands PWD=1234# PWC=new password # RESET# UPTEL1=phone number# UPTEL2=phone number# UPAUTO=ON# vagy OFF# LOWTEL1=phone number# LOWTEL2=phone number# LOWAUTO=ON# or OFF# OUT=activation event# RELAY=activation event# RINGTIME=duration# CALLTIME=duration# RTIME=duration*NO# or NC OUTTIME=duration*NO# or NC RTEL=phone number*rel*out# RTELDEL=phone number# STATUS?# INFOSMS=phone number# Password for programming, default setting:1234 Changing the password. The password is a 4-digit number. Resetting the settings and the password to default. Primary phone number for upper pushbutton. Secondary phone number for upper pushbutton. In case the call to UPTEL1 fails, UPTEL2 phone number will be called without having to push the button again, if the parameter is ON. Primary phone number for lower pushbutton. Secondary phone number for lower pushbutton. In case the call to LOWTEL1 fails, LOWTEL2 phone number will be called without having to push the button again, if the parameter is ON. Voltage output control: OFF: disable, BUTTON: when button is pressed INPUT: when input is activated, PHONE: during call, pressing any of the phone s keys, IN+PHONE: INPUT and PHONE enabled Relay control: OFF: disable, BUTTON: when button is pressed INPUT: when input is activated Ringing time of the telephone to restrict the reach of voice mail. (10-120sec) Maximum duration of the conversation. (10-600 sec) Duration and idle mode of the relay output activation. (1-120 sec) NO=off, NC=on Duration and idle mode of the voltage output activation. (1-120 sec) NO=off, NC=on Setting the phone numbers for relay or voltage output activation. For output activation the suffix after the phone number is necessary. *REL: switch the realy, *OUT: switch the voltage out, *REL*OUT switch both. Up to 100 users. Delete the selected phone number frm the RTEL list. Query of the settings, except for the RTEL list. Forwards the balance information of the GSM provider to the given telephone number.

This scenario shows the configurations for the following requirements: phone number 2 only for upper pushbutton, auto switch to the secondary phone, VOUT control (for electric lock) by phone and input contact, duration is 10sec, both phone numbers are able to control the gate control s relay by a free call, relay activation time is 5sec. Other call parameters: Ringingtime=25sec; maximum duration of the conversation=120sec; forwarding prepaid card information to primary phone number SMS message: PWD=1234#UPTEL1=0036309999999#UPTEL2=0036201111111#UPAUTO=ON#OUT=IN+PHONE# OUTTIME=10*NO#RTEL=0036309999999*REL#RTEL=0036201111111*REL#RTIME=5*NO# RINGTIME=25#CALLTIME=120#INFOSMS=0036201111111# INSTALLATION Putting into operation Disable PIN code request on the SIM card, for which a mobile telephone is necessary. Make sure the SIM card is inserted properly into its case. Inserting the SIM card: push the metallic part of the SIM case towards the direction of the arrow to open up the SIM slot for inserting the card. Insert the SIM card into the slot so that its contact surface should point towards the contact pins of the card case when turned down, as well as the cut corner of the card should fit into the plastic case. Fasten the SIM card by pulling back the metallic part of the SIM case. Make sure the antenna is fixed properly into the SMA connector. Make sure the wires are connected as shown in the connection diagram. Make sure the power supply is sufficient for the operation of the unit! If it is, and all connections are done, the unit can be powered up. When operated with an electric lock, the minimum power requirement is 15VA! Connection diagram Mounting Do not mount the unit where it could be affected by strong electromagnetic disturbances. Antenna: the GSM antenna supplied with the unit provides good transmission under normal reception circumstances. In case of having signal strength problems and/or noisy communication, use other type of higher gain antenna or find a more suitable place for the antenna. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 GSM antenna connector Contact input Relay contact output Voltage output Power input Speaker output Microphone input Battery connector solar powered version only! Name plate lighting USB mini B port Call pushbuttons Status LEDs SIM card case Coded control output not supported function Common negative point

TECHNICAL SPECIFICATION Name Other conditions Minimum Typical Maximum Unit Power supply (DC_IN) 9 12 / 24 30 VDC Current consumption in case of 12VDC 30 40 400 ma 24 V 30 V Relay output load 5 A Voltage output DC_IN 1V V 1 A Contact input switching 0 0 100 Ohm Operating temperature -30 +60 C Outdoor protection IP54 Other data Transmission frequency GSM850 / EGSM900 DCS1800 / PCS1900 Dimensions height: 165mm width: 122mm depth: 40mm Package contents MSS-UP200-GSM GSM 900MHz / 1800MHz antenna USB A / B5 mini cable Antenna bracket + fixing screws Optional MPS1205 Power Supply Unit Microsound Systems cc. 101 Ehrenberg Technical Centre, 55 Booysens Road, Booysens, 2091 P.O.Box 38220, Booysens, 2016 Tel: +27(0)11 4932424; Fax: +27(0)11 493 0347 www.microsound.co.za email: sales@microsound.co.za VAT Nº: 4680120146 / CK 1986-006545-23