New Activation Key for Module Changes: Using Server Files to Reinstall the Cornerstone* Software

Similar documents
Installation Guide. Cornerstone* 8.5 NEXT Software and IDEXX-PACS* Imaging Software. Plan for your upgrade

Installation Guide. Cornerstone* 8.5 NEXT Software and IDEXX-PACS* Imaging Software. Plan for your upgrade

GiftMaker Pro & EventMaker Pro 8.2

Abila MIP. Human Resource Management Installation Guide

Abila MIP DrillPoint Reports. Installation Guide

Agilent MassHunter Workstation Software Offline Qualitative and Quantitative Analysis

Updating CAESY Enterprise 7.0 to Suite 9

FAS Asset Accounting FAS Asset Inventory FAS CIP Accounting Network Installation & Administration Guide Version

Eaglesoft 19 Installation Instructions

Install New Java Client, Release GL 3.1 For Workstations Currently without Java

Abila MIP. Installation Guide

Dentrix Learning Edition. Installation Instructions

Eaglesoft 18.1 Installation Instructions

About this guide. This guide provides a list. used under. Suite 310. Canada

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory Installation & Administration Guide Version

This installation guide is intended for customers who are installing NMIS for the first time. Included are the recommended hardware specifications

CS SoftDent Practice Management Software Installation Guide for Client/Server Configurations

Easy Dental Installation Guide

PCLaw Installation and Upgrade Guide

Multi User License Installation

Media Writer. Installation Guide LX-DOC-MW5.1.9-IN-EN-REVB. Version 5.1.9

Activant Compass Installation Guide For Upgrades to Version 4.1 or Higher

Parallels Desktop 4.0 Switch to Mac Edition. Migrate your PC Tutorial.

Tax Library - Single Computer Install

Wireless-N USB Network Adapter. with Dual-Band QUICK INSTALLATION GUIDE. Package Contents

easy to use. easy to own. INSTALLATION GUIDE

Junxure Code Upgrade Instructions

Read Naturally SE Update Windows Network Installation Instructions

Jonas Activity Management Technical Deployment Guide

Employee Web Services. Installation Guide

Registering Your D1 with the System (Windows 2000)

MF9300. Software setup guide

JPRO Fleet Service Portal User s Guide

Desktop Deployment Guide

VetConnect* PLUS. Online Services. User s Guide

Agilent MassHunter Workstation Software for Triple Quad LC/MS

Bluetooth Software Installation Readme

Mac OS X 10.6 Snow Leopard Installation and Setup Guide

A & A Library - Network Install

easy to use. easy to own. Installation Guide Version 11

3. IMPORTANT: When prompted, accept the default Installation directory.

AVImark Lab Frequently Asked About Errors. AVImark Software Support 5 Sugar Creek Road Piedmont, MO Phone Fax

LiveNX Upgrade Guide from v5.1.2 to v Windows

FASTT Math Next Generation Installation Guide

Acronis Backup & Recovery 11 Beta Advanced Editions

IDEXX VetLab Station Integration Instructions

Halcyon Spooled File Manager GUI. v8.0 User Guide

FAS Asset Accounting FAS CIP Accounting FAS Asset Inventory SQL Server Installation & Administration Guide Version

Version 6.3 Upgrade Guide

Scholastic Reading Inventory Installation Guide

HR-Lite Database & Web Service Setup Guide

Version 17. Nuclear Medicine Information. New Network User Installation

SkyPoint Installation & Licensing Guide

Welcome to Helper 9 Installation Instructions

Fusion. Installation Guide

Configuring the WebDAV Folder for Adding Multiple Files to the Content Collection and Editing Them

SoftPro Installation Guide

Galileo Desktop SM 2.1. Installation Guide

Tips for Loading Galileo Print Manager Over a Previous Version of Focalpoint Print Manager

INSTALLATION GUIDE. Trimble AllTrak Software

Sage Abra Suite. Installation Guide

Storage Security Software (Version )

Boot Camp Installation & Setup Guide

Remote Deposit Service

Pharos Uniprint 8.3. Upgrade Guide. Document Version: UP83-Upgrade-1.0. Distribution Date: December 2011

How to make a Work Profile for Windows 10

NOTE: We recommend using a static IP address on your Eaglesoft database server machine.

Business Insights Dashboard

Image Backup and Recovery Procedures For Windows 7

Sabre Customer Virtual Private Network Launcher (SCVPNLauncher)

System 44 Next Generation Installation Guide

Abaxis Data Manager Installation Instructions

Access Gateway Client User's Guide

How to install the software of ZNS8022

C 5/28/2009 Setup and Operation for Bluetooth Last Edited: Jimmy Nejmeh

PaperStream Capture Pro Installation Guide

LexisNexis PCLaw Installation & Upgrade Guide

How to set up an Amazon Work Profile for Windows 8

Chapter A1: Setting up BankLink Practice, BankLink Notes and BankLink Notes Online

Installation Assistance Windows/Microsoft Updates Updating from Spectra 7.x Upgrading from Spectra 6.x... 7

EntraPass WebStation. Reference Manual DN

Lab - Configure Data Backup and Recovery in Windows 7 and Vista

FREEDOM-Pad Installation and Operation

CCH ProSystem fx Practice Management

Installing AppleWorks 6 FOR WINDOWS

COINS Ti Call Management System Standard Installation Instructions for Citrix Users

Backstage. Sof tware Suite. Quick-start guide

Chapter 1: Introduction About the User Manual Intended Audience Conventions Used Revision History 4

Note: Act Today provide this KB article as a courtesy however accept no responsibility for content or the recipient performing these steps

Boot Camp Installation & Setup Guide

Quick Install Guide. Wireless-G Network PCI Adapter. WLP54G 3a

Boot Camp Installation & Setup Guide

Silk Performance Manager Installation and Setup Help

Backup everything to cloud / local storage. CloudBacko Home. Essential steps to get started

READ 180 Next Generation Installation Guide

ABAXIS VETSCAN CHEMISTRY VERSION AND HIGHER

USB-MIDI Driver installation and settings...1 Windows XP users... 1

CONVERSION STANLEY MANUFACTURED ACCESS CONTROL. Invented for life UPGRADING FROM BOSCH READYKEY X V3.1

Microsoft Outlook Installation for Windows GroupWise Users

Software Conversion Guide

Transcription:

New Activation Key for Module Changes: Using Server Files to Reinstall the Cornerstone* Software The following instructions guide you through updating your Cornerstone* Practice Management Software with a new activation key to add or remove modules. IMPORTANT: You must reinstall Cornerstone software on the server and workstations, which requires the Cornerstone software to be down for the entire reinstallation. The update can take from 30 minutes to a few hours, depending on database size, Cornerstone version, server specifications, and other factors. If you have questions, contact Cornerstone Support at 1-800-695-2877 for assistance. These instructions apply only if all of the following are true: Your Cornerstone software version is 7.6 through 8.3 NEXT. You use files on your server to install Cornerstone software. Your activation key is for adding/removing Cornerstone modules. Note: If you install Cornerstone using CDs/DVDs (as opposed to using files on your server), use the alternate instructions found at idexx.com/cornerstoneresources, under Hardware and Computer System Information. If your new activation key is only for changing the number of seats/users, use these instructions. Before you begin IMPORTANT: If your practice has the mobile computing module, you must synchronize and undo all mobile computers before continuing. 1: Verify the installed version of Cornerstone 1. From the Cornerstone menu bar, click Help > About IDEXX Cornerstone. 2. On the first or second line of the window, locate and write down (below) the version number. It will read Cornerstone #.#.## or Cornerstone build #.#.##.##. Version number: Be sure to write down all numbers listed. 1

2: Close Cornerstone software on all computers and shut down other systems 1. Close any programs that are open, including the Cornerstone software, on all computers including the server; leave all computers on, including the computer you use for capturing radiographs. 2. If your practice uses the IDEXX SmartLink* In-house Laboratory module with the IDEXX VetLab* Station, shut down the IDEXX VetLab Station. 3. If your practice has an IDEXX LaserCyte* Dx Hematology Analyzer, IDEXX VetTest* Chemistry Analyzer, or Abaxis* VetScan* Analyzer connected directly to your Cornerstone system (not through an IDEXX VetLab* Station), do the following on the computer that is your Cornerstone laboratory workstation: a. Press CTRL+ALT+DELETE, select Manager or Start Manager, and then click the Processes tab. b. Select vsccom32.exe, and then click the End Process button. A message asks you to confirm that you want to do this. c. Click Yes or End Process. If you have any other analyzer or diagnostic device connected directly to your Cornerstone system (not through an IDEXX VetLab Station), call Cornerstone Support at 1-800-695-2877 for instructions. IMPORTANT: To avoid altering your Cornerstone default image storage location, if your images are stored in a location other than your server, that workstation must remain logged into Microsoft* Windows* until you complete 5: Update the database below. 3. Close Cornerstone database Cornerstone version 7.6: 1. On the server, right-click the Cornerstone database icon in the system tray next to the time and then click Exit. You may need to click the show hidden icons button or to see all icons. Note: If there is no Cornerstone Database icon in the system tray: a. Press CTRL+ALT+DELETE, and then click Manager or Start Manager. b. Click the Processes tab, and select dbsrv7.exe. If dbsrv7.exe is not listed, this means: The database has been closed already. You can close the Manager window. OR You are not on the Cornerstone server. Close the Manager window, and then repeat these steps on the server. c. Click End Process, and then click Yes or End Process. Cornerstone version 8.3 or later: 1. Click Start > Programs or All Programs > Cornerstone > Cornerstone Database Server. The IDEXX Database and Services window opens. 2. Click Stop All to stop the database and all services. 2

4: Reinstall Cornerstone software on the server 1. On the server, double-click Computer or My Computer, and then navigate to Local Disc (C:) > Cstone > Share > Install. 2. Right-click the Release folder and then click Copy. 3. Navigate to Local Disc (C:) > Windows > Temp; right-click within the Temp folder and then click Paste. 4. Open the Release folder from the Temp folder and double-click setup.exe. 5. On the Welcome window, click Next. 6. On the License Agreement window, select Accept and then click Next. 7. On the Activation Key window, enter the new activation key (including the dashes), and then click Next. 8. On the Setup window, do not change the server type selection (the correct server type is already selected); click Next. 9. When the message about backing up your database appears, click OK. 10. When a message appears stating that the backup was completed successfully, click OK. 11. On the Select Features window, verify that the module you are adding or removing is listed in the list of modules with a check mark, and then click Next. All modules included in the activation key are displayed with a check mark and the destination where Cornerstone will be installed. Note: If the module is not checked in the window, contact Cornerstone Support. 12. On the Start Copying Files window, click Next. 13. When you see a message that you must update the database to complete the installation, click OK. 14. On the Install Shield Wizard Complete window, select the Yes, I want to restart my computer now option, and then click Finish. The server restarts. 15. If you are reinstalling only a full release version of the Cornerstone software (no service packs), continue to step 5 below; otherwise, complete steps 16 17. 16. Stop the database if it was restarted. 17. To install service packs: a. On the server, double-click Computer or My Computer, and then navigate to Local Disc (C:) > Cstone > Share > Install. b. Right-click the Service Pack folder and click Copy. c. Navigate to Local Disc (C:) > Windows > Temp; right-click within the Temp folder and click Paste. d. Open the Service Pack folder from the Temp folder and double-click. The Welcome window appears. e. Follow steps 5 14 above to complete the installation. f. When Cornerstone is at the same version as it was before you started updating your activation key, proceed to the next section, 5. Update the Database. To avoid future confusion, when all upgrades are complete, delete the setup.exe file from the server desktop. 3

5: Update the database Perform the database update immediately after changing the activation key on the server and before reinstalling Cornerstone on any of the thick-client workstations. IMPORTANT: The database update can take from 30 minutes to a few hours, depending on database size, Cornerstone version, server specifications, and other factors. 1. Start the Cornerstone database using your normal process. 2. To update the database, on the server click Start > Run. 3. Type c:\cstone\csupdate.exe and then click OK. 4. If you see a message reminding you to shut down your IDEXX VetLab* Station, make sure the IDEXX VetLab Station computer is shut down, and then click OK. 5. On the Cornerstone Update window, click OK. Additional prompts may appear asking if you want Cornerstone to automatically print the Itemized Audit Trail during end of day processing and if you want to use Backup Verification Assistant. 6. Read through the prompt messages and make selections as needed. These options can be turned on or off at any time by Cornerstone Support, if needed. 7. Ensure the text in the white window states Database key validation successful under all the Checking database key entries, and then click OK. If Database key validation successful is not listed, contact Cornerstone Support at 1-800-695-2877. 8. On the server desktop (the main screen), double-click Computer or My Computer. 9. Navigate to Local Disc (C:) > Windows > Temp. 10. Click the Release folder to highlight it, and then hold down the keyboard CTRL key while you click the Service pack folder (if you installed a service pack). 11. Now that both folders are highlighted, right-click on one of the folders and select Delete. 12. Restart the server. You can now continue with your normal daily processes on the server and can use Cornerstone on any thin-client workstations. Note: All thick-client workstations must be reinstalled with the new activation key before you can use Cornerstone software on them. See the next section. 4

6: Install Cornerstone on thick-client workstations Remember: If you re reinstalling both a full release and a service pack, be sure to reinstall the full release first, and then install the service pack. As soon as the reinstallation is complete on a workstation, you can use Cornerstone on that workstation. 1. To install from the files located on the Server, click Start > Run. 2. Type \\server and click OK. 3. Note: If the name of the Cornerstone server is not Server, you ll need to change this to the server s actual name (e.g., \\cstone-svr). 4. Navigate to Cstone Share > Install > Release. Double-click setup.exe. 5. The Welcome window appears. 6. On the Welcome window, click Next. 7. On the License Agreement window, click Accept and click Next. 8. Enter the new activation key (including the dashes), and then click Next. 9. On the Setup window, Workstation should already be selected; click Next. 10. On the Select Features window, click Next. 11. All modules included in the activation key are displayed with a check mark and the destination where Cornerstone will be installed 12. On the Start Copying Files window, click Next. 13. On the Install Shield Wizard Complete window, click the Yes, I want to restart my computer now option, and then click Finish. The workstation now restarts. 14. If you need to reinstall a service pack, follow steps 1 10 above, except that in step 3, navigate to the Service Pack folder (instead of the Release folder). 7: Verify the activation key has been updated on all workstations For each workstation, verify that the activation key has been updated and the practice ID is correct: 1. From the menu bar, click Help > About IDEXX Cornerstone. The About IDEXX Cornerstone window appears. 2. Click More., and then ensure that the activation key under Clinic information is the new activation key and that the practice ID is correct. If the key and ID are correct, you can continue using Cornerstone on this computer. If the Activation Key was not automatically updated on a workstation, close Cornerstone software, and repeat the instructions in 6: Install Cornerstone on thick-client workstations. 3. Repeat the steps above to verify the key on each workstation. If you experience difficulties after reinstalling the Cornerstone software on the workstation, contact Cornerstone Support at 1-800-695-2877. 2016 IDEXX Laboratories, Inc. All rights reserved. 06-6000003-03 *Cornerstone, IDEXX VetLab, LaserCyte, IDEXX SmartLink, and VetTest are trademarks or registered trademarks of IDEXX Laboratories, Inc. or its affiliates in the United States and/or other countries. All other product and company names and logos are trademarks of their respective holders. 5