PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

Similar documents
MANUAL Surge Protectors

PROCESS AUTOMATION. Installation Technology for FOUNDATION Fieldbus

5 Fieldbus Technology

FACTORY AUTOMATION. CONFIGURATION INSTRUCTIONS WCS3B-LS*** with RS485 interface

New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs. Andreas Agostin Pepperl+Fuchs

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

PROCESS AUTOMATION INSTALLATION TECHNOLOGY FOR PROFIBUS PA

Trusted Strategic Partners in Process Automation. Alliance Member

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Distributed Intrinsically Safe Fieldbus Applications

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

QUICK START GUIDE IC-KP2-*

FACTORY AUTOMATION SAFETY LIGHT CURTAINS SLCS AND SLCT SERIES

technical datasheet technical datasheet 9370-FB Series Fieldbus Barrier Enclosures, 6 or 12 spur

FACTORY AUTOMATION MANUAL CBX500 HOST INTERFACE MODULES

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

FACTORY AUTOMATION TAILORED TO YOUR APPLICATION MODULAR SAFETY MONITORING UNIT

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Enclosures for Remote I/O System I.S. 1

PHOENIX CONTACT - 01/2008

BA414DF Fieldbus indicator Single variable

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

PHOENIX CONTACT - 12/2007

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

PI-EX-ME-2NAM/COC-120VAC

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

PI-EX-ME-2NAM/COC-24VDC

PHOENIX CONTACT - 05/2007

FACTORY AUTOMATION MANUAL PMI360DV-F130-IU2E2- V15

FACTORY AUTOMATION. Manual IVI-KHD2-4HD1. Control Unit

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

PROCESS AUTOMATION MANUAL F2-SP-IC*

Roxar CorrLog High Accuracy Corrosion Monitoring

MANUAL Temperature Multi-Input Device

THE BARRIER and the Universal Barrier Cabinets from Pepperl+Fuchs

FACTORY AUTOMATION. Manual IVI-KHD2-4HD3. Control Unit with 8 Inputs/Outputs

PROFIBUS-PA Positioner Type 3785

SYSTEMS AND COMPONENTS

MANUAL Multi-Input/Output Device

Inductive sensor BI1.5-EG08-Y1-H1341

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

Inductive sensor NI3-EG08K-Y1-H1341

Ex magnetic safety sensors, cylindrical form // Series EEx RC Si M30

PROCESS AUTOMATION SIMPLIFY PROCESSES FIELDCONNEX INFRASTRUCTURE FOR PROFIBUS PA

FACTORY AUTOMATION INSTRUCTION MANUAL. AS-Interface Safety at Work VAA-2E-G4-SN. Version 1.2

FACTORY AUTOMATION MANUAL MAH* FIRMWARE UPGRADE INSTRUCTIONS

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

Indication and Adjustment Product Information VEGADIS 61. Level Switching Pressure

FACTORY AUTOMATION TAMING THE POWER F99 SERIES INCLINATION AND ACCELERATION SENSORS

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital

QUICK START GUIDE 2-D Laser Scanner

DC Power Considerations for Intrinsically Safe Applications

Inductive sensor with analog output BI15-M30-LI-EXI

Flow Measurement SITRANS F M. Transmitter MAG 6000 I/6000 I Ex de. 3/46 Siemens FI

FACTORY AUTOMATION EASY DETECTION OF SMALL PARTS SLOT AND SLOT GRID SENSORS

PROCESS AUTOMATION. MANUAL Compact Fieldbus Power Hub, Common Interface

About the FLEX Ex I/O Systems

FOUNDATION. Product Overview. Foundation Fieldbus

PROCESS AUTOMATION MANUAL FIELDBUS POWER HUB INVENSYS

Digital electropneumatic positioner

FACTORY AUTOMATION MANUAL VISION CONFIGURATOR

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2

07. har-link INTERFACE CONNECTORS

SOLUTIONS FOR THE PHARMACEUTICAL INDUSTRY Solutions for the Pharmaceutical Industry

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3

Roxar SandLog High Accuracy Sand/Erosion Monitoring

80265 series, 3/2 Indirect solenoid actuated poppet valve

FACTORY AUTOMATION. M18 Threaded light beam switches

process automation protecting your process

SERVING THE WORLD S INFRASTRUCTURE PRODUCTS AND SOLUTIONS FOR THE POWER AND UTILITY INDUSTRIES

FACTORY AUTOMATION. QUICK START GUIDE VBP-HH1-V3.0-V1 AS-Interface Handheld

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Operating Instructions

07. har-link Interface Connectors

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

Inductive sensor BI1.5-EG08-Y1-H1341

QUICK START GUIDE ODT-HH-MAH300 Handheld

Pepperl+Fuchs Fieldbus Power Hub for Redundant Fieldbus Power

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

MANUAL SEGMENT CHECKER

BL compact fieldbus station for DeviceNet 16 Configurable Digital PNP Channels BLCDN-16M8L-8XSG-P-8XSG-P

FACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D

HERION SERIES Indirect solenoid actuated spool valves

TYPE APPROVAL CERTIFICATE

Transcription:

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

OUR COMPONENTS... CONFIGURABLE TO YOUR NEEDS No application is like the others; every application always places new requirements on the properties and configuration of a fieldbus junction box. We bear witness to this fact with the new modular Field Junction Box System for our familiar FieldConnex products. Besides the housing size, you can customize your Field Junction Box to your own personal needs, from the cable glands to the electronics to overvoltage protection. Besides a custom-fit solution for your application, the Field Junction Box allows the fastest possible installation on location, reducing engineering costs at the same time. STAINLESS STEEL HOUSING SS36L/.444 ELECTRONICS S 28 mm x 7 mm x mm Protection class IP68/Type 6-5 C + 8 C Field barrier RD-FB-EX4 Connection of highest number of intrinsically safe field devices to a modern field bus Installation in Zone /Class I, Div. 2 Galvanic isolation and overload protection at the spur Reduced wiring S2 3 mm x 2 mm x 2 mm Protection class IP68-5 C +8 C Segment Protector R-JBSC- / R-SP-N Connection of field devices to modern fieldbus Installation in Zone 2/Class I, Div. 2 Increased reliability due to protection from short-circuits and overload Fast, efficient fault finding and correction using LED display S2 377 mm x 377 mm x 6 mm Protection class IP68-5 C +8 C S3 48 mm x 4 mm x 6 mm Protection class IP68-5 C +8 C Temperature Multi-input RD-TI-EX8.FF.ST Efficient integration of eight different analogue signals into the fieldbus communications Intrinsic safety: Installation in Zone /Class I, Div. High flexibility, large selection of sensors can be connected Reliable systems operation due to continuous monitoring of sensors and connection lines Excellent data quality due to potential isolation of inputs and very short update cycles Valve coupler FD-VC-EX4.FF Efficient control of four solenoid valves with end position sensing via one fieldbus address Intrinsic safety: Installation in Zone /Class I, Div. Line break and short-circuit monitoring of inputs and outputs Power supply through the fieldbus cable

Ex-tested installation solutions for fieldbus in zones /2/2/22 and Div. /Div. 2 Customer-oriented availability Customer- and industry-specific solutions for fieldbus distribution (non-ex, too) CABLE GLANDS TERMINALS Dummy plugs M2 M2 cable gland, plastic Screw terminal EEx e II G D,2 mm 2 4 mm 2, 24 AWG AWG M2 cable gland Nickel-plated brass M2 cable gland Stainless steel Screw terminal with disconnector EEx ia,2 mm 2 2,5 mm 2, 24 AWG 2 AWG M2 cable gland for reinforced cable, brass, nickel-plated M2 cable gland for reinforced cable, Stainless steel Spring terminal EEx e II G D,2 mm 2 2,5 mm 2, 24 AWG 2 AWG Plug connector 7/8", Nickel-plated brass EEx e II GD Plastic IP66/Type 4X UL certificate -3 C +7 C Metal IP68/Type 6 UL certificate -4 C +8 C Spring terminal with blade insulation terminal EEx ia,8 mm 2 2,5 mm 2, 28 AWG 2 AWG

OVERVOLTAGE PROTECTION TERMINAL RESISTANCE DB-LB-I/DP-LBF-I According to FISCO or Entity Installation in Zone Two-part structure, base module DB-LB-I is mounted on DIN rail and serves as socket for the protection module DP-LBF-I KMD-FT-E Bus terminator for installation on DIN rails Reliable fieldbus communications by damping line reflections According to FISCO and Entity Field Junction Box the trusted F2 aluminium housing Field Junction Box also available in polyester (GRP) housing

TYPE KEY FOR TECHNICAL INFORMATION FAMILY F B S P... T I V C Field barrier RD-FB-EX4 Segment Protector R-JBSC- / R-SP-N Temperature Multi-input RD-TI-EX8.FF.ST Valve coupler FD-VC-EX4.FF HOUSING TYPES S P EX CERTIFICATE 7 Stainless steel SS36L/.444 Polyester (GRP) Certificate NUMBER OF CHANNELS 4 6 8 2 6 2 4 3 2 4 channels 6 channels 8 channels channels 2 channels 6 channels 24 channels 32 channels FIELDBUS F P TERMINALS 3 5 GLANDS & CONNECTIONS H H 2 H C G P 2 G B 2 G S 2 G N 2 G A 2 G C V 9 ACCESSORIES Foundation Fieldbus H + Profibus PA Foundation Fieldbus H Profibus PA No terminals Screw terminals Spring terminals Customer version Boring 2.5 mm Blind plugs M2 Hole for special diameter M2 cable gland, plastic M2 cable gland, nickel-plated brass M2 cable gland, stainless steel M2 cable gland for reinforced cable, nickel-plated brass M2 cable gland for reinforced cable, stainless steel Customer specified Plug connector 7/8", nickel-plated brass A B 2 3 T No plate for labelling Plastic plate for labelling, 2mm x 4mm Stainless steel plate for labelling, 2mm x 4mm Without grounding bar With grounding bar No overvoltage protection Overvoltage protection on spurs and trunk Overvoltage protection on spurs Overvoltage protection on trunk No terminating resistance Terminating resistance

TECHNICAL DATA VARIANT STAINLESS STEEL HOUSING General housing features SS36L/.444 high-gloss polish Condensate drain / ventilation M grounding screws Mounting brackets Door hinges DIN rail Variant with plastic gland Variant with metal gland Protection class IP66 per EN 6529/NEMA 4X IP68 per EN 6529/NEMA 6 Operating temperature 3 C +7 C 4 C +7 C Storage temperature 4 C +8 C 4 C +8 C Climatic conditions compliant with DIN IEC 72 DIN IEC 72 Shock resistance 7 Nm per EN 54 7 Nm per EN 54 Approvals In process In process Worldwide Headquarters Pepperl+Fuchs GmbH 6837 Mannheim Germany Tel. 62 776- E-Mail: info@de.pepperl-fuchs.com USA Headquarters Pepperl+Fuchs Inc. Twinsburg, Ohio 4487 USA Tel. + 33 4253555 E-Mail: sales@us.pepperl-fuchs.com Asia Pacific Headquarters Pepperl+Fuchs Pte Ltd. Singapore 39942 Company Registration No.9933E Tel. +65 677999 E-Mail: sales@sg.pepperl-fuchs.com www.pepperl-fuchs.com Subject to reasonable modifications due to technical advances Copyright PEPPERL+FUCHS Printed in Germany Part. No. 928 3/6